Skip to main content
Top
Published in: Abdominal Radiology 5/2019

01-05-2019 | Computed Tomography | Hepatobiliary

Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study

Authors: Sun Kyoung You, Young Hun Choi, Jung-Eun Cheon, Woo Sun Kim, In-One Kim, So Mi Lee, Hyun-Hae Cho

Published in: Abdominal Radiology | Issue 5/2019

Login to get access

Abstract

Purpose

To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children.

Materials and methods

The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18): tube voltage, 70 kVp; and iodine concentration,: 250 mgI/mL versus Conventional protocol (Group B, n = 13): tube voltage, 80–100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded.

Results

The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59–0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively).

Conclusion

The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality.
Literature
1.
go back to reference Miglioretti DL, Johnson E, Williams A, Greenlee RT, Weinmann S, Solberg LI, Feigelson HS, Roblin D, Flynn MJ, Vanneman N (2013) The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. JAMA Pediatrics 167:700–707CrossRefPubMedPubMedCentral Miglioretti DL, Johnson E, Williams A, Greenlee RT, Weinmann S, Solberg LI, Feigelson HS, Roblin D, Flynn MJ, Vanneman N (2013) The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. JAMA Pediatrics 167:700–707CrossRefPubMedPubMedCentral
2.
go back to reference Zacharias C, Alessio AM, Otto RK, Iyer RS, Philips GS, Swanson JO, Thapa MM (2013) Pediatric CT: strategies to lower radiation dose. AJR American Journal of Roentgenology 200:950–956CrossRefPubMedPubMedCentral Zacharias C, Alessio AM, Otto RK, Iyer RS, Philips GS, Swanson JO, Thapa MM (2013) Pediatric CT: strategies to lower radiation dose. AJR American Journal of Roentgenology 200:950–956CrossRefPubMedPubMedCentral
3.
go back to reference Yu L, Bruesewitz MR, Thomas KB, Fletcher JG, Kofler JM, McCollough CH (2011) Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls. Radiographics 31:835–848CrossRefPubMed Yu L, Bruesewitz MR, Thomas KB, Fletcher JG, Kofler JM, McCollough CH (2011) Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls. Radiographics 31:835–848CrossRefPubMed
4.
go back to reference Nakayama Y, Awai K, Funama Y, Hatemura M, Imuta M, Nakaura T, Ryu D, Morishita S, Sultana S, Sato N (2005) Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise 1. Radiology 237:945–951CrossRefPubMed Nakayama Y, Awai K, Funama Y, Hatemura M, Imuta M, Nakaura T, Ryu D, Morishita S, Sultana S, Sato N (2005) Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise 1. Radiology 237:945–951CrossRefPubMed
5.
go back to reference Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32–61CrossRefPubMed Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32–61CrossRefPubMed
6.
go back to reference Singh J, Daftary A (2008) Iodinated contrast media and their adverse reactions. Journal of Nuclear Medicine Technology 36:69–74CrossRefPubMed Singh J, Daftary A (2008) Iodinated contrast media and their adverse reactions. Journal of Nuclear Medicine Technology 36:69–74CrossRefPubMed
7.
go back to reference Beckett KR, Moriarity AK, Langer JM (2015) Safe use of contrast media: what the radiologist needs to know. Radiographics 35:1738–1750CrossRefPubMed Beckett KR, Moriarity AK, Langer JM (2015) Safe use of contrast media: what the radiologist needs to know. Radiographics 35:1738–1750CrossRefPubMed
8.
go back to reference Barrett BJ, Parfrey PS (2006) Preventing nephropathy induced by contrast medium. New England Journal of Medicine 354:379–386CrossRefPubMed Barrett BJ, Parfrey PS (2006) Preventing nephropathy induced by contrast medium. New England Journal of Medicine 354:379–386CrossRefPubMed
9.
go back to reference Verghese PS (2014) Contrast nephropathy in children. Journal of Pediatric Intensive Care 3:045–052 Verghese PS (2014) Contrast nephropathy in children. Journal of Pediatric Intensive Care 3:045–052
10.
go back to reference Nyman U, Almén T, Aspelin P, Hellström M, Kristiansson M, Sterner G (2005) Contrast-medium-Induced nephropathy correlated to the ratio between dose in gram iodine and estimated GFR in mL/min. Acta Radiologica 46:830–842CrossRefPubMed Nyman U, Almén T, Aspelin P, Hellström M, Kristiansson M, Sterner G (2005) Contrast-medium-Induced nephropathy correlated to the ratio between dose in gram iodine and estimated GFR in mL/min. Acta Radiologica 46:830–842CrossRefPubMed
11.
go back to reference Kim JH, Kim MJ, Kim HY, Lee MJ (2014) Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique. Clinical Imaging 38:710–714CrossRefPubMed Kim JH, Kim MJ, Kim HY, Lee MJ (2014) Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique. Clinical Imaging 38:710–714CrossRefPubMed
12.
go back to reference Khawaja RDA, Singh S, Otrakji A, Padole A, Lim R, Nimkin K, Westra S, Kalra MK, Gee MS (2015) Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms. Pediatric Radiology 45:1046–1055CrossRefPubMed Khawaja RDA, Singh S, Otrakji A, Padole A, Lim R, Nimkin K, Westra S, Kalra MK, Gee MS (2015) Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms. Pediatric Radiology 45:1046–1055CrossRefPubMed
13.
go back to reference Shen Y, Hu X, Zou X, Zhu D, Li Z, Hu D (2016) Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of “double low” for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years. International journal of clinical practice 70. Shen Y, Hu X, Zou X, Zhu D, Li Z, Hu D (2016) Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of “double low” for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years. International journal of clinical practice 70.
14.
go back to reference Durand S, Paul J-F (2014) Comparison of image quality between 70ákVp and 80ákVp: application to paediatric cardiac CT. European Radiology 24:3003–3009CrossRefPubMed Durand S, Paul J-F (2014) Comparison of image quality between 70ákVp and 80ákVp: application to paediatric cardiac CT. European Radiology 24:3003–3009CrossRefPubMed
15.
go back to reference Nakagawa M, Ozawa Y, Sakurai K, Shimohira M, Ohashi K, Asano M, Yamaguchi S, Shibamoto Y (2015) Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease. Pediatric Radiology 45:1472–1479CrossRefPubMedPubMedCentral Nakagawa M, Ozawa Y, Sakurai K, Shimohira M, Ohashi K, Asano M, Yamaguchi S, Shibamoto Y (2015) Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease. Pediatric Radiology 45:1472–1479CrossRefPubMedPubMedCentral
16.
go back to reference Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex-and age-specific conversion factors used to determine effective dose from dose-length product 1. Radiology 257:158–166CrossRefPubMed Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex-and age-specific conversion factors used to determine effective dose from dose-length product 1. Radiology 257:158–166CrossRefPubMed
17.
go back to reference Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, Samei E (2009) Low-tube-voltage, high-tube-current multidetector abdominal ct: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm—initial clinical experience 1. Radiology 254:145–153CrossRef Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, Samei E (2009) Low-tube-voltage, high-tube-current multidetector abdominal ct: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm—initial clinical experience 1. Radiology 254:145–153CrossRef
18.
go back to reference Takahashi H, Okada M, Hyodo T, Hidaka S, Kagawa Y, Matsuki M, Tsurusaki M, Murakami T (2014) Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver? European Journal of Radiology 83:684–691CrossRefPubMed Takahashi H, Okada M, Hyodo T, Hidaka S, Kagawa Y, Matsuki M, Tsurusaki M, Murakami T (2014) Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver? European Journal of Radiology 83:684–691CrossRefPubMed
19.
go back to reference Nakaura T, Nakamura S, Maruyama N, Funama Y, Awai K, Harada K, Uemura S, Yamashita Y (2012) Low contrast agent and radiation dose protocol for hepatic dynamic CT of thin adults at 256–detector row CT: effect of low tube voltage and hybrid iterative reconstruction algorithm on image quality. Radiology 264:445–454CrossRefPubMed Nakaura T, Nakamura S, Maruyama N, Funama Y, Awai K, Harada K, Uemura S, Yamashita Y (2012) Low contrast agent and radiation dose protocol for hepatic dynamic CT of thin adults at 256–detector row CT: effect of low tube voltage and hybrid iterative reconstruction algorithm on image quality. Radiology 264:445–454CrossRefPubMed
20.
go back to reference Namimoto T, Oda S, Utsunomiya D, Shimonobo T, Morita S, Nakaura T, Yamashita Y (2012) Improvement of image quality at low-radiation dose and low-contrast material dose abdominal CT in patients with cirrhosis: intraindividual comparison of low tube voltage with iterative reconstruction algorithm and standard tube voltage. Journal of Computer Assisted Tomography 36:495–501CrossRefPubMed Namimoto T, Oda S, Utsunomiya D, Shimonobo T, Morita S, Nakaura T, Yamashita Y (2012) Improvement of image quality at low-radiation dose and low-contrast material dose abdominal CT in patients with cirrhosis: intraindividual comparison of low tube voltage with iterative reconstruction algorithm and standard tube voltage. Journal of Computer Assisted Tomography 36:495–501CrossRefPubMed
21.
go back to reference Zhang X, Li S, Liu W, Huang N, Li J, Cheng L, Xu K (2016) Double-low protocol for hepatic dynamic CT scan: effect of low tube voltage and low-dose iodine contrast agent on image quality. Medicine 95:e4004CrossRefPubMedPubMedCentral Zhang X, Li S, Liu W, Huang N, Li J, Cheng L, Xu K (2016) Double-low protocol for hepatic dynamic CT scan: effect of low tube voltage and low-dose iodine contrast agent on image quality. Medicine 95:e4004CrossRefPubMedPubMedCentral
22.
go back to reference Geyer LL, Schoepf UJ, Meinel FG, Nance Jr JW, Bastarrika G, Leipsic JA, Paul NS, Rengo M, Laghi A, De Cecco CN (2015) State of the art: iterative CT reconstruction techniques. Radiology 276:339–357CrossRefPubMed Geyer LL, Schoepf UJ, Meinel FG, Nance Jr JW, Bastarrika G, Leipsic JA, Paul NS, Rengo M, Laghi A, De Cecco CN (2015) State of the art: iterative CT reconstruction techniques. Radiology 276:339–357CrossRefPubMed
23.
go back to reference Padole A, Ali Khawaja RD, Kalra MK, Singh S (2015) CT radiation dose and iterative reconstruction techniques. American Journal of Roentgenology 204:W384–W392CrossRefPubMed Padole A, Ali Khawaja RD, Kalra MK, Singh S (2015) CT radiation dose and iterative reconstruction techniques. American Journal of Roentgenology 204:W384–W392CrossRefPubMed
24.
go back to reference Kalra MK, Woisetschläger M, Dahlström N, Singh S, Lindblom M, Choy G, Quick P, Schmidt B, Sedlmair M, Blake MA (2012) Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography. Journal of Computer Assisted Tomography 36:339–346CrossRefPubMed Kalra MK, Woisetschläger M, Dahlström N, Singh S, Lindblom M, Choy G, Quick P, Schmidt B, Sedlmair M, Blake MA (2012) Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography. Journal of Computer Assisted Tomography 36:339–346CrossRefPubMed
25.
go back to reference Schabel C, Fenchel M, Schmidt B, Flohr TG, Wuerslin C, Thomas C, Korn A, Tsiflikas I, Claussen CD, Heuschmid M (2013) Clinical evaluation and potential radiation dose reduction of the novel sinogram-affirmed iterative reconstruction technique (SAFIRE) in abdominal computed tomography angiography. Academic Radiology 20:165–172CrossRefPubMed Schabel C, Fenchel M, Schmidt B, Flohr TG, Wuerslin C, Thomas C, Korn A, Tsiflikas I, Claussen CD, Heuschmid M (2013) Clinical evaluation and potential radiation dose reduction of the novel sinogram-affirmed iterative reconstruction technique (SAFIRE) in abdominal computed tomography angiography. Academic Radiology 20:165–172CrossRefPubMed
26.
go back to reference NNakaura T, Awai K, Maruyama N, Takata N, Yoshinaka I, Harada K, Uemura S, Yamashita Y (2011) Abdominal dynamic CT in patients with renal dysfunction: contrast agent dose reduction with low tube voltage and high tube current–time product settings at 256–detector row CT. Radiology 261:467–476CrossRefPubMed NNakaura T, Awai K, Maruyama N, Takata N, Yoshinaka I, Harada K, Uemura S, Yamashita Y (2011) Abdominal dynamic CT in patients with renal dysfunction: contrast agent dose reduction with low tube voltage and high tube current–time product settings at 256–detector row CT. Radiology 261:467–476CrossRefPubMed
27.
go back to reference Raman SP, Johnson PT, Deshmukh S, Mahesh M, Grant KL, Fishman EK (2013) CT dose reduction applications: available tools on the latest generation of CT scanners. Journal of the American College of Radiology 10:37–41CrossRefPubMed Raman SP, Johnson PT, Deshmukh S, Mahesh M, Grant KL, Fishman EK (2013) CT dose reduction applications: available tools on the latest generation of CT scanners. Journal of the American College of Radiology 10:37–41CrossRefPubMed
28.
go back to reference Wang W, Zhao YE, Qi L, Li X, Zhou CS, Zhang LJ, Lu GM (2017) Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: an intraindividual comparison with sequential scanning at 120 kVp with 60 mL contrast agent. European Journal of Radiology 90:97–105CrossRefPubMed Wang W, Zhao YE, Qi L, Li X, Zhou CS, Zhang LJ, Lu GM (2017) Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: an intraindividual comparison with sequential scanning at 120 kVp with 60 mL contrast agent. European Journal of Radiology 90:97–105CrossRefPubMed
29.
go back to reference Li X, Ni QQ, Schoepf UJ, Wichmann JL, Felmly LM, Qi L, Kong X, Zhou CS, Luo S, Zhang LJ, Lu GM (2015) 70-kVp high-pitch computed tomography pulmonary angiography with 40 mL contrast agent: initial experience. Academic Radiology 22:1562–1570CrossRefPubMed Li X, Ni QQ, Schoepf UJ, Wichmann JL, Felmly LM, Qi L, Kong X, Zhou CS, Luo S, Zhang LJ, Lu GM (2015) 70-kVp high-pitch computed tomography pulmonary angiography with 40 mL contrast agent: initial experience. Academic Radiology 22:1562–1570CrossRefPubMed
30.
go back to reference Chen GZ, Fang XK, Zhou CS, Zhang LJ, Lu GM (2017) Cerebral CT angiography with iterative reconstruction at 70kVp and 30 mL iodinated contrast agent: initial experience. European Journal of Radiology 88:102–108CrossRefPubMed Chen GZ, Fang XK, Zhou CS, Zhang LJ, Lu GM (2017) Cerebral CT angiography with iterative reconstruction at 70kVp and 30 mL iodinated contrast agent: initial experience. European Journal of Radiology 88:102–108CrossRefPubMed
31.
go back to reference Karcaaltincaba M, Oguz B, Haliloglu M (2009) Current status of contrast-induced nephropathy and nephrogenic systemic fibrosis in children. Pediatric Radiology 39:382–384CrossRefPubMed Karcaaltincaba M, Oguz B, Haliloglu M (2009) Current status of contrast-induced nephropathy and nephrogenic systemic fibrosis in children. Pediatric Radiology 39:382–384CrossRefPubMed
32.
go back to reference Maliborski A, Żukowski P, Nowicki G, Bogusławska R (2011) Contrast-induced nephropathy–a review of current literature and guidelines. Medical science monitor: international medical journal of experimental and clinical research 17: RA199. Maliborski A, Żukowski P, Nowicki G, Bogusławska R (2011) Contrast-induced nephropathy–a review of current literature and guidelines. Medical science monitor: international medical journal of experimental and clinical research 17: RA199.
33.
go back to reference Saint-Laurent Q Consensus Guidelines for the Prevention of Contrast Induced Nephropathy. Saint-Laurent Q Consensus Guidelines for the Prevention of Contrast Induced Nephropathy.
34.
go back to reference Trout AT, Dillman JR, Ellis JH, Cohan RH, Strouse PJ (2011) Patterns of intravenous contrast material use and corticosteroid premedication in children—a survey of Society of Chairs of Radiology in Children’s Hospitals (SCORCH) member institutions. Pediatric Radiology 41:1272–1283CrossRefPubMed Trout AT, Dillman JR, Ellis JH, Cohan RH, Strouse PJ (2011) Patterns of intravenous contrast material use and corticosteroid premedication in children—a survey of Society of Chairs of Radiology in Children’s Hospitals (SCORCH) member institutions. Pediatric Radiology 41:1272–1283CrossRefPubMed
35.
go back to reference Zo’o M, Hoermann M, Balassy C, Brunelle F, Azoulay R, Pariente D, Panuel M, Le Dosseur P (2011) Renal safety in pediatric imaging: randomized, double-blind phase IV clinical trial of iobitridol 300 versus iodixanol 270 in multidetector CT. Pediatric Radiology 41:1393CrossRefPubMedPubMedCentral Zo’o M, Hoermann M, Balassy C, Brunelle F, Azoulay R, Pariente D, Panuel M, Le Dosseur P (2011) Renal safety in pediatric imaging: randomized, double-blind phase IV clinical trial of iobitridol 300 versus iodixanol 270 in multidetector CT. Pediatric Radiology 41:1393CrossRefPubMedPubMedCentral
Metadata
Title
Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study
Authors
Sun Kyoung You
Young Hun Choi
Jung-Eun Cheon
Woo Sun Kim
In-One Kim
So Mi Lee
Hyun-Hae Cho
Publication date
01-05-2019
Publisher
Springer US
Published in
Abdominal Radiology / Issue 5/2019
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-019-01896-6

Other articles of this Issue 5/2019

Abdominal Radiology 5/2019 Go to the issue

Classics in Abdominal Radiology

The “phantom” calyx

Classics in Abdominal Radiology

The “maiden waist” sign of the ureters

Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.