Abstract

Purpose

To describe CT features of parathyroid carcinomas (PCs) by comparison with benign parathyroid lesions (BPs).

Methods

This retrospective study comprised 82 patients with 76 BPs (62 adenomas and 14 hyperplastic lesions) and 6 PCs. CT features (size, short-to-long axis ratio, shape, peritumoral infiltration, homogeneity, calcification, attenuation values on unenhanced CT, and contrast enhancement during arterial and venous phases) were compared between PCs and BPs. The diagnostic performance of CT features for diagnosing PCs was calculated for these individual parameters.

Results

Short-to-long axis ratio was significantly larger in PCs (0.7 ± 0.1) than in BPs (0.5 ± 0.1, p = 0.004). Irregular shape (33%), the presence of peritumoral infiltration (50%), and calcification (33%) were significantly more common in PCs than BPs. The contrast enhancement value was significantly lower in PCs than BPs during arterial (p = 0.004) and venous phases (p = 0.044). The 100% sensitivity criterion for the short-to-long axis ratio (≥ 0.53), enhancement during arterial phase (≤ 56.6HU), and venous phase (≤ 59.5HU) yielded accuracies (62.1%, 71.9%, and 75.4%, respectively). Irregular shape, peritumoral infiltration, and calcification showed high specificity (98.7%) and accuracy (93.9%, 95.1%, and 93.9%, respectively).

Conclusions

CT features of high short-to-long axis ratio, irregular shape, the presence of peritumoral infiltration and calcification, and low contrast enhancement may aid in distinguishing PCs from BPs.
Literature
1.
2.
go back to reference Obara T, Okamoto T, Kanbe M, Iihara M. Functioning parathyroid carcinoma: clinicopathologic features and rational treatment. Semin Surg Oncol. 1997;13:134–41.CrossRefPubMed Obara T, Okamoto T, Kanbe M, Iihara M. Functioning parathyroid carcinoma: clinicopathologic features and rational treatment. Semin Surg Oncol. 1997;13:134–41.CrossRefPubMed
3.
go back to reference Givi B, Shah JP. Parathyroid carcinoma. Clin Oncol (R Coll Radiol). 2010;22:498–507.CrossRef Givi B, Shah JP. Parathyroid carcinoma. Clin Oncol (R Coll Radiol). 2010;22:498–507.CrossRef
4.
5.
go back to reference Hara H, Igarashi A, Yano Y, Yashiro T, Ueno E, Aiyoshi Y, et al. Ultrasonographic features of parathyroid carcinoma. Endocr J. 2001;48:213–7.CrossRefPubMed Hara H, Igarashi A, Yano Y, Yashiro T, Ueno E, Aiyoshi Y, et al. Ultrasonographic features of parathyroid carcinoma. Endocr J. 2001;48:213–7.CrossRefPubMed
6.
go back to reference Sidhu PS, Talat N, Patel P, Mulholl NJ, Schulte KM. Ultrasound features of malignancy in the preoperative diagnosis of parathyroid cancer: a retrospective analysis of parathyroid tumours larger than 15 mm. Eur Radiol. 2011;21:1865–73.CrossRefPubMed Sidhu PS, Talat N, Patel P, Mulholl NJ, Schulte KM. Ultrasound features of malignancy in the preoperative diagnosis of parathyroid cancer: a retrospective analysis of parathyroid tumours larger than 15 mm. Eur Radiol. 2011;21:1865–73.CrossRefPubMed
7.
go back to reference Cheon M, Choi JY, Chung JH, Lee JY, Cho SK, Yoo J, et al. Differential findings of tc-99m sestamibi dual-phase parathyroid scintigraphy between benign and malignant parathyroid lesions in patients with primary hyperparathyroidism. Nucl Med Mol Imaging. 2011;45:276–84.CrossRefPubMedPubMedCentral Cheon M, Choi JY, Chung JH, Lee JY, Cho SK, Yoo J, et al. Differential findings of tc-99m sestamibi dual-phase parathyroid scintigraphy between benign and malignant parathyroid lesions in patients with primary hyperparathyroidism. Nucl Med Mol Imaging. 2011;45:276–84.CrossRefPubMedPubMedCentral
8.
go back to reference Evangelista L, Sorgato N, Torresan F, Boschin IM, Pennelli G, Saladini G, et al. FDG-PET/CT and parathyroid carcinoma: review of literature and illustrative case series. World J Clin Oncol. 2011;2:348–54.CrossRefPubMedPubMedCentral Evangelista L, Sorgato N, Torresan F, Boschin IM, Pennelli G, Saladini G, et al. FDG-PET/CT and parathyroid carcinoma: review of literature and illustrative case series. World J Clin Oncol. 2011;2:348–54.CrossRefPubMedPubMedCentral
9.
go back to reference Krudy AG, Doppman JL, Marx SJ, Brennan MF, Spiegel A, Aurback GD. Radiographic findings in recurrent parathyroid carcinoma. Radiology. 1982;142:625–9.CrossRefPubMed Krudy AG, Doppman JL, Marx SJ, Brennan MF, Spiegel A, Aurback GD. Radiographic findings in recurrent parathyroid carcinoma. Radiology. 1982;142:625–9.CrossRefPubMed
10.
go back to reference Mortenson MM, Evans DB, Lee JE, Hunter GJ, Shellingerhout D, Vu T, et al. Parathyroid exploration in the reoperative neck: improved preoperative localization with 4D computed tomography. J Am Coll Surg. 2008;206:888–95.CrossRefPubMed Mortenson MM, Evans DB, Lee JE, Hunter GJ, Shellingerhout D, Vu T, et al. Parathyroid exploration in the reoperative neck: improved preoperative localization with 4D computed tomography. J Am Coll Surg. 2008;206:888–95.CrossRefPubMed
11.
go back to reference Rodgers SE, Hunter GJ, Hamberg LM, Schellingerhout D, Doherty DB, Ayers GD, et al. Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography. Surgery. 2006;140:932–40.CrossRefPubMed Rodgers SE, Hunter GJ, Hamberg LM, Schellingerhout D, Doherty DB, Ayers GD, et al. Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography. Surgery. 2006;140:932–40.CrossRefPubMed
12.
go back to reference Hoang JK, Sung WK, Bahl M, Phillips CD. How to perform parathyroid 4D CT: tips and traps for technique and interpretation. Radiology. 2014;270:15–24.CrossRefPubMed Hoang JK, Sung WK, Bahl M, Phillips CD. How to perform parathyroid 4D CT: tips and traps for technique and interpretation. Radiology. 2014;270:15–24.CrossRefPubMed
13.
go back to reference Gafton AR, Glastonbury CM, Eastwood JD, Hoang JK. Parathyroid lesions: characterization with dual-phase arterial and venous enhanced CT of the neck. AJNR Am J Neuroradiol. 2012;33:949–52.CrossRefPubMed Gafton AR, Glastonbury CM, Eastwood JD, Hoang JK. Parathyroid lesions: characterization with dual-phase arterial and venous enhanced CT of the neck. AJNR Am J Neuroradiol. 2012;33:949–52.CrossRefPubMed
14.
go back to reference Christakis I, Vu T, Chuang HH, Fellman B, Figueroa AMS, Williams MD, et al. The diagnostic accuracy of neck ultrasound, 4D-Computed tomographyand sestamibi imaging in parathyroid carcinoma. Eur J Radiol. 2017;95:82–8.CrossRefPubMed Christakis I, Vu T, Chuang HH, Fellman B, Figueroa AMS, Williams MD, et al. The diagnostic accuracy of neck ultrasound, 4D-Computed tomographyand sestamibi imaging in parathyroid carcinoma. Eur J Radiol. 2017;95:82–8.CrossRefPubMed
15.
go back to reference Xue S, Chen H, Lv C, Shen X, Ding J, Liu J, et al. Preoperative diagnosis and prognosis in 40 Parathyroid Carcinoma Patients. Clin Endocrinol (Oxf). 2016;85:29–36.CrossRef Xue S, Chen H, Lv C, Shen X, Ding J, Liu J, et al. Preoperative diagnosis and prognosis in 40 Parathyroid Carcinoma Patients. Clin Endocrinol (Oxf). 2016;85:29–36.CrossRef
16.
go back to reference Iacobone M, Lumachi F, Favia G. Up-to-date on parathyroid carcinoma: analysis of an experience of 19 cases. J Surg Oncol. 2004;88:223–8.CrossRefPubMed Iacobone M, Lumachi F, Favia G. Up-to-date on parathyroid carcinoma: analysis of an experience of 19 cases. J Surg Oncol. 2004;88:223–8.CrossRefPubMed
17.
go back to reference Edmonson GR, Charboneau JW, James EM, Reading CC, Grant CS. Parathyroid carcinoma: high-frequency sonographic features. Radiology. 1986;161:65–7.CrossRefPubMed Edmonson GR, Charboneau JW, James EM, Reading CC, Grant CS. Parathyroid carcinoma: high-frequency sonographic features. Radiology. 1986;161:65–7.CrossRefPubMed
18.
go back to reference Goodman A, Politz D, Lopez J, Norman J. Intrathyroid parathyroid adenoma: incidence and location-the case against thyroid lobectomy. Otolaryngol Head Neck Surg. 2011;144:867–71.CrossRefPubMed Goodman A, Politz D, Lopez J, Norman J. Intrathyroid parathyroid adenoma: incidence and location-the case against thyroid lobectomy. Otolaryngol Head Neck Surg. 2011;144:867–71.CrossRefPubMed
19.
22.
go back to reference Beland MD, Mayo-Smith WW, Grand DJ, Machan JT, Monchik JM. Dynamic MDCT for localization of occult parathyroid adenomas in 26 patients with primary hyperparathyroidism. AJR Am J Roentgenol. 2011;196:61–5.CrossRefPubMed Beland MD, Mayo-Smith WW, Grand DJ, Machan JT, Monchik JM. Dynamic MDCT for localization of occult parathyroid adenomas in 26 patients with primary hyperparathyroidism. AJR Am J Roentgenol. 2011;196:61–5.CrossRefPubMed
23.
go back to reference Hunter GJ, Schellingerhout D, Vu TH, Perrier ND, Hamberg LM. Accuracy of four-dimensional CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism. Radiology. 2012;264:789–95.CrossRefPubMed Hunter GJ, Schellingerhout D, Vu TH, Perrier ND, Hamberg LM. Accuracy of four-dimensional CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism. Radiology. 2012;264:789–95.CrossRefPubMed
24.
go back to reference Bahl M, Sepahdari AR, Sosa JA, Hoang JK. Parathyroid adenomas and hyperplasia on four-dimensional CT scans: three patterns of enhancement relative to the thyroid gland justify a three-phase protocol. Radiology. 2015;277:454–62.CrossRefPubMed Bahl M, Sepahdari AR, Sosa JA, Hoang JK. Parathyroid adenomas and hyperplasia on four-dimensional CT scans: three patterns of enhancement relative to the thyroid gland justify a three-phase protocol. Radiology. 2015;277:454–62.CrossRefPubMed
25.
go back to reference Lee EK, Yun TJ, Kim JH, Lee KE, Kim SJ, Won JK, et al. Effect of tumor volume on the enhancement pattern of parathyroid adenoma on parathyroid four-dimensional CT. Neuroradiology. 2016;58:495–501.CrossRefPubMed Lee EK, Yun TJ, Kim JH, Lee KE, Kim SJ, Won JK, et al. Effect of tumor volume on the enhancement pattern of parathyroid adenoma on parathyroid four-dimensional CT. Neuroradiology. 2016;58:495–501.CrossRefPubMed
Metadata
Title
CT features of parathyroid carcinomas: comparison with benign parathyroid lesions
Authors
Koji Takumi
Yoshihiko Fukukura
Hiroto Hakamada
Hiroaki Nagano
Yuichi Kumagae
Hideo Arima
Akihiro Nakajo
Takashi Yoshiura
Publication date
01-05-2019
Publisher
Springer Japan
Published in
Japanese Journal of Radiology / Issue 5/2019
Print ISSN: 1867-1071
Electronic ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-019-00825-3

Other articles of this Issue 5/2019

Japanese Journal of Radiology 5/2019 Go to the issue