Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study

Authors: Nermeen Nagi, Ahmed Mahmoud Fouda, Christoph Bourauel

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

The aim of the study was to investigate the effect of material and occlusal preparation design on the internal fit and marginal gap of endocrowns made of Polyether ether ketone (PEEK) and lithium disilicate.

Methods

32 endocrowns were fabricated on prepared mandibular molars and divided into two groups (n = 16) according to the material. Group L: lithium disilicate and Group P: PEEK. Each group was further subdivided into two subgroups (n = 8) according to the occlusal preparation design: full occlusal coverage (LF and PF) and partial occlusal coverage (LP and PP). Samples were analyzed using microcomputed tomography (µCT) with a voxel size of 6 μm to evaluate internal fit, and an optical microscope was used to evaluate the marginal gap. Data were collected, tabulated, and statistically analyzed. Numerical data were described as mean and standard deviation and compared using the ANOVA test. The level of significance was set at α P ≤ 0.05.

Results

All groups’ internal fit and marginal gaps values were within the acceptable clinical range. However, the lithium disilicates group recorded statistically significantly higher mean internal gap values than the PEEK groups. Regardless of the material, the difference between the two occlusal designs was not statistically significant in both internal fit and marginal gap records.

Conclusion

Within the limitations of this study, PEEK endocrown restorations revealed better internal fit and marginal gap than lithium disilicate endocrown restorations. The marginal and internal fit of both lithium disilicate and PEEK endocrown restorations were within the clinically acceptable range. The occlusal preparation design had no influence on the internal fit and marginal gap of the endocrown restoration.
Literature
6.
go back to reference Kurtz SM. PEEK biomaterials handbook. Waltham, MA, USA: Elsevier Science; 2012. Kurtz SM. PEEK biomaterials handbook. Waltham, MA, USA: Elsevier Science; 2012.
10.
go back to reference Buso L, Hilgert E, Neisser MP, Bottino MA. Marginal fit of electroformed copings before and after the coction of the porcelain. Braz J Oral Sci. 2004;3:409–13. Buso L, Hilgert E, Neisser MP, Bottino MA. Marginal fit of electroformed copings before and after the coction of the porcelain. Braz J Oral Sci. 2004;3:409–13.
29.
go back to reference Bindl A, Mörmann WH. Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years – preliminary results. J Adhes Dent. 1999;1:255–65. PMID: 11725673.PubMed Bindl A, Mörmann WH. Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years – preliminary results. J Adhes Dent. 1999;1:255–65. PMID: 11725673.PubMed
33.
go back to reference Alajaji NK, Bardwell DR, Finkelman M, Ali A. (2017) Micro-CT evaluation of ceramic inlays: compari-son of the marginal and internal fit of five and three axis CAM systems with a heat press technique. J Esthet Restor Dent 2017; 29:49–58. https://doi.org/10.1111/jerd.12271. Alajaji NK, Bardwell DR, Finkelman M, Ali A. (2017) Micro-CT evaluation of ceramic inlays: compari-son of the marginal and internal fit of five and three axis CAM systems with a heat press technique. J Esthet Restor Dent 2017; 29:49–58. https://​doi.​org/​10.​1111/​jerd.​12271.
46.
go back to reference Makky MR, Shokry TE, Metwally MF. Comparison of marginal and internal fit of Copings fabricated from Polyetheretherketone and Zirconia: an in-vitro study. Al-Azhar J Dent Sci. 2020;23:355–62.CrossRef Makky MR, Shokry TE, Metwally MF. Comparison of marginal and internal fit of Copings fabricated from Polyetheretherketone and Zirconia: an in-vitro study. Al-Azhar J Dent Sci. 2020;23:355–62.CrossRef
49.
go back to reference Comba A, Baldi A, Carossa M, Michelotto Tempesta R, Garino E, Llubani X, Rozzi D, Mikonis J, Paolone G, Scotti N. Post-Fatigue Fracture Resistance of Lithium Disilicate and Polymer-Infiltrated Ceramic Network Indirect Restorations over endodontically treated molars with different preparation designs: an in-vitro study. Polymers. 2022;14:5084. https://doi.org/10.3390/polym14235084.CrossRefPubMedPubMedCentral Comba A, Baldi A, Carossa M, Michelotto Tempesta R, Garino E, Llubani X, Rozzi D, Mikonis J, Paolone G, Scotti N. Post-Fatigue Fracture Resistance of Lithium Disilicate and Polymer-Infiltrated Ceramic Network Indirect Restorations over endodontically treated molars with different preparation designs: an in-vitro study. Polymers. 2022;14:5084. https://​doi.​org/​10.​3390/​polym14235084.CrossRefPubMedPubMedCentral
Metadata
Title
Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study
Authors
Nermeen Nagi
Ahmed Mahmoud Fouda
Christoph Bourauel
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-02857-8

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue