Abstract

Objectives

To observe if blood return, also defined as the blood infusion test (BIT) could predict fluid responsiveness in critically ill patients with acute circulatory failure and renal replacement therapy (RRT).

Methods

This was a single-center, prospective, diagnostic accuracy study. Before BIT, the passive leg raise test (PLRT) was performed to record the change of cardiac output (ΔCO) by pulse contour analysis, and ΔCO >  = 10% was defined as the fluid responder. Meanwhile, the change in velocity time integral (ΔVTI) was recorded by ultrasound. Later, the ΔCO and ΔVTI during BIT were recorded 5–10 min after PLRT. The receiver-operating characteristic curves of ΔCO and ΔVTI of BIT were performed in predicting the fluid responder defined by PLRT.

Results

A total of 43 patients with acute circulatory failure undergoing RRT were enrolled in the present study, and 25 patients (58.1%) were recognized as responders during PLRT. According to the receiver-operating characteristic curves, the cutoff value of ΔCO was 10% and ΔVTI was 9% during BIT with the area under curve of 0.96 and 0.94, respectively.

Conclusions

BIT in RRT could identify fluid responsiveness in critically ill patients with shock.

Trial registration

ChiCTR-DDD-17010534. Registered on 30/01/2017 (retrospective registration).
Appendix
Available only for authorised users
Literature
1.
go back to reference Hoste EA, Bagshaw SM, Bellomo R, Cely CM, Colman R, Cruz DN, et al. Epidemiology of acute kidney injury in critically ill patients: the multinational AKI-EPI study. Intensive Care Med. 2015;41(8):1411–23.CrossRef Hoste EA, Bagshaw SM, Bellomo R, Cely CM, Colman R, Cruz DN, et al. Epidemiology of acute kidney injury in critically ill patients: the multinational AKI-EPI study. Intensive Care Med. 2015;41(8):1411–23.CrossRef
2.
go back to reference Monnet X, Marik PE, Teboul JL. Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016;6(1):111.CrossRef Monnet X, Marik PE, Teboul JL. Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016;6(1):111.CrossRef
3.
go back to reference Vieillard-Baron A, Millington SJ, Sanfilippo F, Chew M, Diaz-Gomez J, McLean A, et al. A decade of progress in critical care echocardiography: a narrative review. Intensive Care Med. 2019;45(6):770–88.CrossRef Vieillard-Baron A, Millington SJ, Sanfilippo F, Chew M, Diaz-Gomez J, McLean A, et al. A decade of progress in critical care echocardiography: a narrative review. Intensive Care Med. 2019;45(6):770–88.CrossRef
4.
go back to reference Monnet X, Teboul JL. Transpulmonary thermodilution: advantages and limits. Critical care (London, England). 2017;21(1):147.CrossRef Monnet X, Teboul JL. Transpulmonary thermodilution: advantages and limits. Critical care (London, England). 2017;21(1):147.CrossRef
5.
go back to reference Huang D, Ma H, Ma J, Hong L, Lian X, Wu Y, et al. A novel supplemental maneuver to predict fluid responsiveness in critically ill patients: blood pump-out test performed before renal replacement therapy. Ann Transl Med. 2020;8(12):786.CrossRef Huang D, Ma H, Ma J, Hong L, Lian X, Wu Y, et al. A novel supplemental maneuver to predict fluid responsiveness in critically ill patients: blood pump-out test performed before renal replacement therapy. Ann Transl Med. 2020;8(12):786.CrossRef
6.
go back to reference Vincent JL, De Backer D. Circulatory shock. N Engl J Med. 2013;369(18):1726–34.CrossRef Vincent JL, De Backer D. Circulatory shock. N Engl J Med. 2013;369(18):1726–34.CrossRef
7.
go back to reference Hoste EA, Maitland K, Brudney CS, Mehta R, Vincent JL, Yates D, et al. Four phases of intravenous fluid therapy: a conceptual model. Br J Anaesth. 2014;113(5):740–7.CrossRef Hoste EA, Maitland K, Brudney CS, Mehta R, Vincent JL, Yates D, et al. Four phases of intravenous fluid therapy: a conceptual model. Br J Anaesth. 2014;113(5):740–7.CrossRef
8.
go back to reference Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, et al. Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016. Intensive Care Med. 2017;43(3):304–77.CrossRef Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, et al. Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016. Intensive Care Med. 2017;43(3):304–77.CrossRef
9.
go back to reference Monnet X, Teboul JL. Passive leg raising. Intensive Care Med. 2008;34(4):659–63.CrossRef Monnet X, Teboul JL. Passive leg raising. Intensive Care Med. 2008;34(4):659–63.CrossRef
10.
go back to reference He HW, Liu DW. Passive leg raising: influence of blood pressure transducer site. Intensive Care Med. 2013;39(9):1668.CrossRef He HW, Liu DW. Passive leg raising: influence of blood pressure transducer site. Intensive Care Med. 2013;39(9):1668.CrossRef
11.
go back to reference Cherpanath TG, Hirsch A, Geerts BF, Lagrand WK, Leeflang MM, Schultz MJ, et al. Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials. Crit Care Med. 2016;44(5):981–91.CrossRef Cherpanath TG, Hirsch A, Geerts BF, Lagrand WK, Leeflang MM, Schultz MJ, et al. Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials. Crit Care Med. 2016;44(5):981–91.CrossRef
12.
go back to reference Broch O, Renner J, Gruenewald M, Meybohm P, Höcker J, Schöttler J, et al. Variation of left ventricular outflow tract velocity and global end-diastolic volume index reliably predict fluid responsiveness in cardiac surgery patients. J Crit Care. 2012;27(3):325.e7-13.CrossRef Broch O, Renner J, Gruenewald M, Meybohm P, Höcker J, Schöttler J, et al. Variation of left ventricular outflow tract velocity and global end-diastolic volume index reliably predict fluid responsiveness in cardiac surgery patients. J Crit Care. 2012;27(3):325.e7-13.CrossRef
13.
go back to reference Shi R, Monnet X, Teboul JL. Parameters of fluid responsiveness. Curr Opin Crit Care. 2020;26(3):319–26.CrossRef Shi R, Monnet X, Teboul JL. Parameters of fluid responsiveness. Curr Opin Crit Care. 2020;26(3):319–26.CrossRef
14.
go back to reference Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, et al. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008. Intensive Care Med. 2008;34(1):17–60.CrossRef Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, et al. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008. Intensive Care Med. 2008;34(1):17–60.CrossRef
15.
go back to reference Dellinger RP, Carlet JM, Masur H, Gerlach H, Calandra T, Cohen J, et al. Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock. Intensive Care Med. 2004;30(4):536–55.CrossRef Dellinger RP, Carlet JM, Masur H, Gerlach H, Calandra T, Cohen J, et al. Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock. Intensive Care Med. 2004;30(4):536–55.CrossRef
16.
go back to reference Muller L, Toumi M, Bousquet PJ, Riu-Poulenc B, Louart G, Candela D, et al. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology. 2011;115(3):541–7.CrossRef Muller L, Toumi M, Bousquet PJ, Riu-Poulenc B, Louart G, Candela D, et al. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology. 2011;115(3):541–7.CrossRef
17.
go back to reference Wu Y, Zhou S, Zhou Z, Liu B. A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness. Crit Care. 2014;18(3):R108.CrossRef Wu Y, Zhou S, Zhou Z, Liu B. A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness. Crit Care. 2014;18(3):R108.CrossRef
18.
go back to reference Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, et al. Fluid challenges in intensive care: the FENICE study: A global inception cohort study. Intensive Care Med. 2015;41(9):1529–37.CrossRef Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, et al. Fluid challenges in intensive care: the FENICE study: A global inception cohort study. Intensive Care Med. 2015;41(9):1529–37.CrossRef
19.
go back to reference Jabot J, Teboul JL, Richard C, Monnet X. Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med. 2009;35(1):85–90.CrossRef Jabot J, Teboul JL, Richard C, Monnet X. Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med. 2009;35(1):85–90.CrossRef
20.
go back to reference Monnet X, Bleibtreu A, Ferré A, Dres M, Gharbi R, Richard C, et al. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med. 2012;40(1):152–7.CrossRef Monnet X, Bleibtreu A, Ferré A, Dres M, Gharbi R, Richard C, et al. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med. 2012;40(1):152–7.CrossRef
21.
go back to reference Messina A, Dell’Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, et al. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Critical care (London, England). 2019;23(1):264.CrossRef Messina A, Dell’Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, et al. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Critical care (London, England). 2019;23(1):264.CrossRef
22.
go back to reference Schmidt S, Westhoff T, Schlattmann P, Zidek W, Compton F. Analysis of Transpulmonary Thermodilution Data Confirms the Influence of Renal Replacement Therapy on Thermodilution Hemodynamic Measurements. Anesth Analg. 2016;122(5):1474–9.CrossRef Schmidt S, Westhoff T, Schlattmann P, Zidek W, Compton F. Analysis of Transpulmonary Thermodilution Data Confirms the Influence of Renal Replacement Therapy on Thermodilution Hemodynamic Measurements. Anesth Analg. 2016;122(5):1474–9.CrossRef
23.
go back to reference Dufour N, Delville M, Teboul JL, Camous L, Favier du Noyer A, Richard C, et al. Transpulmonary thermodilution measurements are not affected by continuous veno-venous hemofiltration at high blood pump flow. Intensive Care Med. 2012;38(7):1162–8.CrossRef Dufour N, Delville M, Teboul JL, Camous L, Favier du Noyer A, Richard C, et al. Transpulmonary thermodilution measurements are not affected by continuous veno-venous hemofiltration at high blood pump flow. Intensive Care Med. 2012;38(7):1162–8.CrossRef
24.
go back to reference Mercado P, Maizel J, Beyls C, Titeca-Beauport D, Joris M, Kontar L, et al. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient. Critical care (London, England). 2017;21(1):136.CrossRef Mercado P, Maizel J, Beyls C, Titeca-Beauport D, Joris M, Kontar L, et al. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient. Critical care (London, England). 2017;21(1):136.CrossRef
25.
go back to reference Villavicencio C, Leache J, Marin J, Oliva I, Rodriguez A, Bodí M, et al. Basic critical care echocardiography training of intensivists allows reproducible and reliable measurements of cardiac output. Ultrasound J. 2019;11(1):5.CrossRef Villavicencio C, Leache J, Marin J, Oliva I, Rodriguez A, Bodí M, et al. Basic critical care echocardiography training of intensivists allows reproducible and reliable measurements of cardiac output. Ultrasound J. 2019;11(1):5.CrossRef
26.
go back to reference Bou Chebl R, Wuhantu J, Kiblawi S, Carnell J. Bedside Echocardiography and Passive Leg Raise as a Measure of Volume Responsiveness in the Emergency Department. J Ultrasound Med. 2019;38(5):1319–26.CrossRef Bou Chebl R, Wuhantu J, Kiblawi S, Carnell J. Bedside Echocardiography and Passive Leg Raise as a Measure of Volume Responsiveness in the Emergency Department. J Ultrasound Med. 2019;38(5):1319–26.CrossRef
27.
go back to reference Bergenzaun L, Gudmundsson P, Öhlin H, Düring J, Ersson A, Ihrman L, et al. Assessing left ventricular systolic function in shock: evaluation of echocardiographic parameters in intensive care. Critical care (London, England). 2011;15(4):R200.CrossRef Bergenzaun L, Gudmundsson P, Öhlin H, Düring J, Ersson A, Ihrman L, et al. Assessing left ventricular systolic function in shock: evaluation of echocardiographic parameters in intensive care. Critical care (London, England). 2011;15(4):R200.CrossRef
28.
go back to reference Umgelter A, Wagner K, Reindl W, Nurtsch N, Huber W, Schmid RM. Haemodynamic effects of plasma-expansion with hyperoncotic albumin in cirrhotic patients with renal failure: a prospective interventional study. BMC Gastroenterol. 2008;8:39.CrossRef Umgelter A, Wagner K, Reindl W, Nurtsch N, Huber W, Schmid RM. Haemodynamic effects of plasma-expansion with hyperoncotic albumin in cirrhotic patients with renal failure: a prospective interventional study. BMC Gastroenterol. 2008;8:39.CrossRef
29.
go back to reference Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, et al. The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med. 2010;38(9):1824–9.CrossRef Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, et al. The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med. 2010;38(9):1824–9.CrossRef
Metadata
Title
Changes of cardiac output and velocity time integral in blood return at the end of renal replacement therapy predict fluid responsiveness in critically Ill patients with acute circulatory failure
Authors
Daozheng Huang
Jie Ma
Shouhong Wang
Tiehe Qin
Feier Song
Tieying Hou
Huan Ma
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2023
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-023-01976-7

Other articles of this Issue 1/2023

BMC Anesthesiology 1/2023 Go to the issue