Background

Pulmonary vein isolation (PVI) using phased radiofrequency (RF) energy has been shown to be effective in the treatment of atrial fibrillation (AF).

Methods

We characterize and compare pulmonary vein (PV) reconnection at repeat ablation in patients with AF after initially successful PVI using phased RF technology (PVAC) or 2nd generation cryoballoon (CB). Eighty five patients undergoing redo PVI using multielectrode PVAC phased RF catheter and 66 patients after CB PVI were enrolled 9.7 ± 3.4 months after the initial ablation procedure.

Results

The percentage of patients with PV reconnection(s) was comparably high between both groups (93% PVAC and 92% CB). However, 75% of all PVs and left common trunks (CTs) isolated with PVAC were reconnected, compared with 52% reconnections after CB PVI (p < 0.001). A mean of 2.79 ± 1.2 PVs and CTs/patient were reconnected after PVAC PVI compared with 1.97 ± 0.8 in CB patients, p < 0.0001. No patients in the CB group had 4 reconnected PVs, while this pattern of reconnection was observed in 33% in the PVAC group (p < 0.0001). The percentage of patients in the PVAC group with ≥3 reconnected PVs was significantly higher compared with CB patients (56 patients (66%) vs. 17 patients (26%), p < 0.0001), while the percentage of patients with no PV reconnection was comparably low in PVAC and CB patients (7 and 8%, respectively). CTs were most frequently reconnected after PVAC PVI (94%) and left superior PVs after CB ablation (67%), respectively.

Conclusions

The number of patients with recurrent AF and PV reconnection(s) at redo PVI was comparably high between both groups. However, the extent and distribution of PV reconnections was different in many aspects, indicating more stable atrial lesions after CB PVI compared with PVAC technology.
Literature
1.
go back to reference Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation. 2005;111(2):127–35.CrossRef Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation. 2005;111(2):127–35.CrossRef
2.
go back to reference Verma A, Kilicaslan F, Pisano E, Marrouche NF, Fanelli R, Brachmann J, et al. Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction. Circulation. 2005;112(5):627–35.CrossRef Verma A, Kilicaslan F, Pisano E, Marrouche NF, Fanelli R, Brachmann J, et al. Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction. Circulation. 2005;112(5):627–35.CrossRef
3.
go back to reference Aryana A, Singh SM, Mugnai G, de Asmundis C, Kowalski M, Pujara DK, et al. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis. J Intervent Cardiac Electrophysiol : Int J Arrhythmias Pacing. 2016;47(3):341–8.CrossRef Aryana A, Singh SM, Mugnai G, de Asmundis C, Kowalski M, Pujara DK, et al. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis. J Intervent Cardiac Electrophysiol : Int J Arrhythmias Pacing. 2016;47(3):341–8.CrossRef
4.
go back to reference Balt JC, Karadavut S, Mulder AA, Luermans JG, Wijffels MC, Boersma LV. Conduction recovery in patients with recurrent atrial fibrillation after pulmonary vein isolation using multi-electrode duty cycled radiofrequency ablation. J Intervent Cardiac Electrophysiol : Int J Arrhythmias Pacing. 2013;37(2):197–204.CrossRef Balt JC, Karadavut S, Mulder AA, Luermans JG, Wijffels MC, Boersma LV. Conduction recovery in patients with recurrent atrial fibrillation after pulmonary vein isolation using multi-electrode duty cycled radiofrequency ablation. J Intervent Cardiac Electrophysiol : Int J Arrhythmias Pacing. 2013;37(2):197–204.CrossRef
5.
go back to reference Callans DJ, Gerstenfeld EP, Dixit S, Zado E, Vanderhoff M, Ren JF, et al. Efficacy of repeat pulmonary vein isolation procedures in patients with recurrent atrial fibrillation. J Cardiovasc Electrophysiol. 2004;15(9):1050–5.CrossRef Callans DJ, Gerstenfeld EP, Dixit S, Zado E, Vanderhoff M, Ren JF, et al. Efficacy of repeat pulmonary vein isolation procedures in patients with recurrent atrial fibrillation. J Cardiovasc Electrophysiol. 2004;15(9):1050–5.CrossRef
6.
go back to reference Spitzer SG, Leitz P, Langbein A, Karolyi L, Scharfe F, Weinmann T, et al. Circumferential pulmonary vein isolation with second-generation multipolar catheter in patients with paroxysmal or persistent atrial fibrillation: Procedural and one-year follow-up results. Int J Cardiol. 2017;241:212–7.CrossRef Spitzer SG, Leitz P, Langbein A, Karolyi L, Scharfe F, Weinmann T, et al. Circumferential pulmonary vein isolation with second-generation multipolar catheter in patients with paroxysmal or persistent atrial fibrillation: Procedural and one-year follow-up results. Int J Cardiol. 2017;241:212–7.CrossRef
7.
go back to reference Knight BP, Novak PG, Sangrigoli R, Champagne J, Dubuc M, Adler SW, et al. Long-Term Outcomes After Ablation for Paroxysmal Atrial Fibrillation Using the Second-Generation Cryoballoon: Final Results From STOP AF Post-Approval Study. JACC Clin Electrophysiol. 2019;5(3):306–14.CrossRef Knight BP, Novak PG, Sangrigoli R, Champagne J, Dubuc M, Adler SW, et al. Long-Term Outcomes After Ablation for Paroxysmal Atrial Fibrillation Using the Second-Generation Cryoballoon: Final Results From STOP AF Post-Approval Study. JACC Clin Electrophysiol. 2019;5(3):306–14.CrossRef
8.
go back to reference Wieczorek M, Hoeltgen R, Brueck M. Does the number of simultaneously activated electrodes during phased RF multielectrode ablation of atrial fibrillation influence the incidence of silent cerebral microembolism? Heart Rhythm. 2013;10(7):953–9.CrossRef Wieczorek M, Hoeltgen R, Brueck M. Does the number of simultaneously activated electrodes during phased RF multielectrode ablation of atrial fibrillation influence the incidence of silent cerebral microembolism? Heart Rhythm. 2013;10(7):953–9.CrossRef
9.
go back to reference De Greef Y, Dekker L, Boersma L, Murray S, Wieczorek M, Spitzer SG, et al. Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD: results of the PRECISION GOLD trial. Europace : Eur Pacing, Arrhythmias, Cardiac Electrophysiol : J Working Groups Cardiac Pacing, Arrhythmias, Cardiac Cell Electrophysiol Eur Soc Cardiol. 2016;18(5):687–95.CrossRef De Greef Y, Dekker L, Boersma L, Murray S, Wieczorek M, Spitzer SG, et al. Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD: results of the PRECISION GOLD trial. Europace : Eur Pacing, Arrhythmias, Cardiac Electrophysiol : J Working Groups Cardiac Pacing, Arrhythmias, Cardiac Cell Electrophysiol Eur Soc Cardiol. 2016;18(5):687–95.CrossRef
10.
go back to reference Wieczorek M, Tajtaraghi S, Sassani K, Hoeltgen R. Incidence of early pulmonary vein reconnections using different energy sources for pulmonary vein isolation: Multielectrode phased radiofrequency vs second-generation cryoballoon. J Cardiovasc Electrophysiol. 2019;30(9):1428–35.CrossRef Wieczorek M, Tajtaraghi S, Sassani K, Hoeltgen R. Incidence of early pulmonary vein reconnections using different energy sources for pulmonary vein isolation: Multielectrode phased radiofrequency vs second-generation cryoballoon. J Cardiovasc Electrophysiol. 2019;30(9):1428–35.CrossRef
11.
go back to reference Gaita F, Leclercq JF, Schumacher B, Scaglione M, Toso E, Halimi F, et al. Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon. J Cardiovasc Electrophysiol. 2011;22(9):961–8.CrossRef Gaita F, Leclercq JF, Schumacher B, Scaglione M, Toso E, Halimi F, et al. Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon. J Cardiovasc Electrophysiol. 2011;22(9):961–8.CrossRef
12.
go back to reference Shah S, Xu W, Adelstein E, Voigt A, Saba S, Jain S. Characterization of pulmonary vein reconnection post Cryoballoon ablation. Indian Pacing Electrophysiol J. 2019;19(4):129–33. Shah S, Xu W, Adelstein E, Voigt A, Saba S, Jain S. Characterization of pulmonary vein reconnection post Cryoballoon ablation. Indian Pacing Electrophysiol J. 2019;19(4):129–33.
13.
go back to reference Rademakers LM, Romero I, Simmers TA, van der Voort PH, Meijer AM, Dekker LR. Spatial distribution of electrical reconnection after pulmonary vein isolation in patients with recurrent paroxysmal atrial fibrillation. Neth Heart J : Mon J Neth Soc Cardiol Neth Heart Found. 2016;24(7–8):481–7.CrossRef Rademakers LM, Romero I, Simmers TA, van der Voort PH, Meijer AM, Dekker LR. Spatial distribution of electrical reconnection after pulmonary vein isolation in patients with recurrent paroxysmal atrial fibrillation. Neth Heart J : Mon J Neth Soc Cardiol Neth Heart Found. 2016;24(7–8):481–7.CrossRef
14.
go back to reference Kistler PM, Ho SY, Rajappan K, Morper M, Harris S, Abrams D, et al. Electrophysiologic and anatomic characterization of sites resistant to electrical isolation during circumferential pulmonary vein ablation for atrial fibrillation: a prospective study. J Cardiovasc Electrophysiol. 2007;18(12):1282–8.CrossRef Kistler PM, Ho SY, Rajappan K, Morper M, Harris S, Abrams D, et al. Electrophysiologic and anatomic characterization of sites resistant to electrical isolation during circumferential pulmonary vein ablation for atrial fibrillation: a prospective study. J Cardiovasc Electrophysiol. 2007;18(12):1282–8.CrossRef
15.
go back to reference Rajappan K, Kistler PM, Earley MJ, Thomas G, Izquierdo M, Sporton SC, et al. Acute and chronic pulmonary vein reconnection after atrial fibrillation ablation: a prospective characterization of anatomical sites. Pacing Clin Electrophysiol : PACE. 2008;31(12):1598–605.CrossRef Rajappan K, Kistler PM, Earley MJ, Thomas G, Izquierdo M, Sporton SC, et al. Acute and chronic pulmonary vein reconnection after atrial fibrillation ablation: a prospective characterization of anatomical sites. Pacing Clin Electrophysiol : PACE. 2008;31(12):1598–605.CrossRef
16.
go back to reference Glowniak A, Tarkowski A, Fic P, Wojewoda K, Wojcik J, Wysokinski A. Second-generation cryoballoon ablation for recurrent atrial fibrillation after an index procedure with radiofrequency versus cryo: Different pulmonary vein reconnection patterns but similar long-term outcome-Results of a multicenter analysis. J Cardiovasc Electrophysiol. 2019;30(7):1005–12.PubMed Glowniak A, Tarkowski A, Fic P, Wojewoda K, Wojcik J, Wysokinski A. Second-generation cryoballoon ablation for recurrent atrial fibrillation after an index procedure with radiofrequency versus cryo: Different pulmonary vein reconnection patterns but similar long-term outcome-Results of a multicenter analysis. J Cardiovasc Electrophysiol. 2019;30(7):1005–12.PubMed
17.
go back to reference Chun KR, Schmidt B, Metzner A, Tilz R, Zerm T, Koster I, et al. The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. Eur Heart J. 2009;30(6):699–709.CrossRef Chun KR, Schmidt B, Metzner A, Tilz R, Zerm T, Koster I, et al. The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. Eur Heart J. 2009;30(6):699–709.CrossRef
18.
go back to reference Heeger CH, Wissner E, Mathew S, Deiss S, Lemes C, Rillig A, et al. Once Isolated, Always Isolated? Incidence and Characteristics of Pulmonary Vein Reconduction After Second-Generation Cryoballoon-Based Pulmonary Vein Isolation. Circ Arrhythm Electrophysiol. 2015;8(5):1088–94.CrossRef Heeger CH, Wissner E, Mathew S, Deiss S, Lemes C, Rillig A, et al. Once Isolated, Always Isolated? Incidence and Characteristics of Pulmonary Vein Reconduction After Second-Generation Cryoballoon-Based Pulmonary Vein Isolation. Circ Arrhythm Electrophysiol. 2015;8(5):1088–94.CrossRef
19.
go back to reference Westra SW, van Vugt SPG, Sezer S, Evertz R, Hemels ME, Beukema RJ, et al. Second-generation cryoballoon ablation for recurrent atrial fibrillation after an index cryoballoon procedure: a staged strategy with variable balloon size. J Interv Cardiac Electrophysiol : Int J Arrhythmias Pacing. 2019;54(1):17–24.CrossRef Westra SW, van Vugt SPG, Sezer S, Evertz R, Hemels ME, Beukema RJ, et al. Second-generation cryoballoon ablation for recurrent atrial fibrillation after an index cryoballoon procedure: a staged strategy with variable balloon size. J Interv Cardiac Electrophysiol : Int J Arrhythmias Pacing. 2019;54(1):17–24.CrossRef
20.
go back to reference Chen S, Schmidt B, Bordignon S, Bologna F, Nagase T, Perrotta L, et al. Practical Techniques in Cryoballoon Ablation: How to Isolate Inferior Pulmonary Veins. Arrhythm Electrophysiol Rev. 2018;7(1):11–7.CrossRef Chen S, Schmidt B, Bordignon S, Bologna F, Nagase T, Perrotta L, et al. Practical Techniques in Cryoballoon Ablation: How to Isolate Inferior Pulmonary Veins. Arrhythm Electrophysiol Rev. 2018;7(1):11–7.CrossRef
21.
go back to reference Buist TJ, Adiyaman A, Smit JJJ, Ramdat Misier AR, Elvan A. Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation. Clin Res Cardiol : Official J Ger Cardiac Soc. 2018;107(6):498–506.CrossRef Buist TJ, Adiyaman A, Smit JJJ, Ramdat Misier AR, Elvan A. Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation. Clin Res Cardiol : Official J Ger Cardiac Soc. 2018;107(6):498–506.CrossRef
22.
go back to reference Nery PB, Belliveau D, Nair GM, Bernick J, Redpath CJ, Szczotka A, et al. Relationship Between Pulmonary Vein Reconnection and Atrial Fibrillation Recurrence: A Systematic Review and Meta-Analysis. JACC Clin Electrophysiol. 2016;2(4):474–83.CrossRef Nery PB, Belliveau D, Nair GM, Bernick J, Redpath CJ, Szczotka A, et al. Relationship Between Pulmonary Vein Reconnection and Atrial Fibrillation Recurrence: A Systematic Review and Meta-Analysis. JACC Clin Electrophysiol. 2016;2(4):474–83.CrossRef
23.
go back to reference Miyazaki S, Taniguchi H, Hachiya H, Nakamura H, Takagi T, Hirao K, et al. Clinical recurrence and electrical pulmonary vein reconnections after second-generation cryoballoon ablation. Heart Rhythm. 2016;13(9):1852–7.CrossRef Miyazaki S, Taniguchi H, Hachiya H, Nakamura H, Takagi T, Hirao K, et al. Clinical recurrence and electrical pulmonary vein reconnections after second-generation cryoballoon ablation. Heart Rhythm. 2016;13(9):1852–7.CrossRef
24.
go back to reference Dixit S, Gerstenfeld EP, Ratcliffe SJ, Cooper JM, Russo AM, Kimmel SE, et al. Single procedure efficacy of isolating all versus arrhythmogenic pulmonary veins on long-term control of atrial fibrillation: a prospective randomized study. Heart Rhythm. 2008;5(2):174–81.CrossRef Dixit S, Gerstenfeld EP, Ratcliffe SJ, Cooper JM, Russo AM, Kimmel SE, et al. Single procedure efficacy of isolating all versus arrhythmogenic pulmonary veins on long-term control of atrial fibrillation: a prospective randomized study. Heart Rhythm. 2008;5(2):174–81.CrossRef
25.
go back to reference Duytschaever M, Anne W, Papiashvili G, Vandekerckhove Y, Tavernier R. Mapping and isolation of the pulmonary veins using the PVAC catheter. Pacing Clin Electrophysiol : PACE. 2010;33(2):168–78.CrossRef Duytschaever M, Anne W, Papiashvili G, Vandekerckhove Y, Tavernier R. Mapping and isolation of the pulmonary veins using the PVAC catheter. Pacing Clin Electrophysiol : PACE. 2010;33(2):168–78.CrossRef
26.
go back to reference Conte G, Soejima K, de Asmundis C, Chierchia GB, Badini M, Miwa Y, et al. Value of high-resolution mapping in optimizing cryoballoon ablation of atrial fibrillation. Int J Cardiol. 2018;270:136–42.CrossRef Conte G, Soejima K, de Asmundis C, Chierchia GB, Badini M, Miwa Y, et al. Value of high-resolution mapping in optimizing cryoballoon ablation of atrial fibrillation. Int J Cardiol. 2018;270:136–42.CrossRef
Metadata
Title
Comparison of pulmonary vein reconnection patterns after multielectrode phased radiofrequency- and cryoballoon ablation of atrial fibrillation
Authors
Marcus Wieczorek
Kiarash Sassani
Reinhard Hoeltgen
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Cardiovascular Disorders / Issue 1/2020
Electronic ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-020-01459-4

Other articles of this Issue 1/2020

BMC Cardiovascular Disorders 1/2020 Go to the issue