Skip to main content
Top
Published in: European Spine Journal 8/2011

01-08-2011 | Ideas and Technical Innovations

Anterior vertebroplasty of adjacent levels after vertebral body replacement

Authors: Florian Geiger, Konstantinos Kafchitsas, Michael Rauschmann

Published in: European Spine Journal | Issue 8/2011

Login to get access

Abstract

The aim of this study was to evaluate the feasibility of a new method, which should help to avoid cage subsidence after vertebrectomy in short fusions. After implantation of an extendable vertebral body replacement (VBR) the two adjacent endplates to the fractured or destroyed vertebra were augmented with bone cement using the anterior approach in 20 patients with short circumferential fusion. All patients were followed up for 2 years clinically and radiographically. X-rays were reviewed for kyphosis, cage subsidence, presence of a solid fusion mass and instrumentation failure. Changes in every day activities (Oswestry Disability Index-ODI) and visual analogue scale (VAS), pain score, as well as technique-related complications were examined. The mean amount of kyphosis correction was 12.8° (±6.4°) and changed by only 0.3° (±0.4°) until last follow-up. Pain (VAS) and ODI scores were significantly improved and did not change until last follow-up. In all but two cases, the authors observed solid union with incorporation of the cage. No surgery-related complications were recorded. In one case revision was advised because of non-union due to septic loosening. The augmentation of the adjacent vertebras after anterior VBR provides an enhancement of the interface between cage and vertebra in cases with poor bone quality and in revision surgery. The technique is simple and safe, as the needles can be placed under visual control. Cement augmentation of the endplates may reduce interbody device subsidence.
Literature
1.
go back to reference (1994) Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. Report of a WHO Study Group. World Health Organ Tech Rep Ser 843:1–129 (1994) Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. Report of a WHO Study Group. World Health Organ Tech Rep Ser 843:1–129
2.
go back to reference Anekstein Y, Brosh T, Mirovsky Y (2007) Intermediate screws in short segment pedicular fixation for thoracic and lumbar fractures: a biomechanical study. J Spinal Disord Tech 20:72–77PubMedCrossRef Anekstein Y, Brosh T, Mirovsky Y (2007) Intermediate screws in short segment pedicular fixation for thoracic and lumbar fractures: a biomechanical study. J Spinal Disord Tech 20:72–77PubMedCrossRef
3.
go back to reference Becker S, Chavanne A, Spitaler R, Kropik K, Aigner N, Ogon M, Redl H (2008) Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J 17:1462–1469PubMedCrossRef Becker S, Chavanne A, Spitaler R, Kropik K, Aigner N, Ogon M, Redl H (2008) Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J 17:1462–1469PubMedCrossRef
4.
go back to reference Briem D, Linhart W, Lehmann W, Bullinger M, Schoder V, Meenen NM, Windolf J, Rueger JM (2003) Investigation of the health-related quality of life after a dorso ventral stabilization of the thoracolumbar junction. Unfallchirurg 106:625–632PubMedCrossRef Briem D, Linhart W, Lehmann W, Bullinger M, Schoder V, Meenen NM, Windolf J, Rueger JM (2003) Investigation of the health-related quality of life after a dorso ventral stabilization of the thoracolumbar junction. Unfallchirurg 106:625–632PubMedCrossRef
5.
go back to reference Chang MC, Liu CL, Chen TH (2008) Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique. Spine (Phila Pa 1976) 33:E317–E324CrossRef Chang MC, Liu CL, Chen TH (2008) Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique. Spine (Phila Pa 1976) 33:E317–E324CrossRef
6.
go back to reference Defino HL, Rodriguez-Fuentes AE (1998) Treatment of fractures of the thoracolumbar spine by combined anteroposterior fixation using the Harms method. Eur Spine J 7:187–194PubMedCrossRef Defino HL, Rodriguez-Fuentes AE (1998) Treatment of fractures of the thoracolumbar spine by combined anteroposterior fixation using the Harms method. Eur Spine J 7:187–194PubMedCrossRef
7.
go back to reference Enad JG, Slakey JB, McNulty PS (2008) Measurement of thoracolumbar kyphosis after burst fracture: evaluation of intraobserver, interobserver, and variability of 4 measurement methods. Am J Orthop (Belle Mead NJ) 37:E60–E63 Enad JG, Slakey JB, McNulty PS (2008) Measurement of thoracolumbar kyphosis after burst fracture: evaluation of intraobserver, interobserver, and variability of 4 measurement methods. Am J Orthop (Belle Mead NJ) 37:E60–E63
8.
go back to reference Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61:531–537PubMedCrossRef Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61:531–537PubMedCrossRef
9.
go back to reference Kalteis T, Luring C, Gugler G, Zysk S, Caro W, Handel M, Grifka J (2004) Acute tissue toxicity of PMMA bone cements. Z Orthop Ihre Grenzgeb 142:666–672PubMedCrossRef Kalteis T, Luring C, Gugler G, Zysk S, Caro W, Handel M, Grifka J (2004) Acute tissue toxicity of PMMA bone cements. Z Orthop Ihre Grenzgeb 142:666–672PubMedCrossRef
10.
go back to reference Kim DH, Vaccaro AR (2006) Osteoporotic compression fractures of the spine; current options and considerations for treatment. Spine J 6:479–487PubMedCrossRef Kim DH, Vaccaro AR (2006) Osteoporotic compression fractures of the spine; current options and considerations for treatment. Spine J 6:479–487PubMedCrossRef
11.
go back to reference Kim HS, Park SK, Joy H, Ryu JK, Kim SW, Ju CI (2008) Bone cement augmentation of short segment fixation for unstable burst fracture in severe osteoporosis. J Korean Neurosurg Soc 44:8–14PubMedCrossRef Kim HS, Park SK, Joy H, Ryu JK, Kim SW, Ju CI (2008) Bone cement augmentation of short segment fixation for unstable burst fracture in severe osteoporosis. J Korean Neurosurg Soc 44:8–14PubMedCrossRef
12.
go back to reference Knop C, Fabian HF, Bastian L, Rosenthal H, Lange U, Zdichavsky M, Blauth M (2002) Fate of the transpedicular intervertebral bone graft after posterior stabilisation of thoracolumbar fractures. Eur Spine J 11:251–257PubMedCrossRef Knop C, Fabian HF, Bastian L, Rosenthal H, Lange U, Zdichavsky M, Blauth M (2002) Fate of the transpedicular intervertebral bone graft after posterior stabilisation of thoracolumbar fractures. Eur Spine J 11:251–257PubMedCrossRef
13.
go back to reference Knop C, Kranabetter T, Reinhold M, Blauth M (2009) Combined posterior-anterior stabilisation of thoracolumbar injuries utilising a vertebral body replacing implant. Eur Spine J 18:949–963PubMedCrossRef Knop C, Kranabetter T, Reinhold M, Blauth M (2009) Combined posterior-anterior stabilisation of thoracolumbar injuries utilising a vertebral body replacing implant. Eur Spine J 18:949–963PubMedCrossRef
14.
go back to reference Knop C, Lange U, Bastian L, Oeser M, Blauth M (2001) Biomechanical compression tests with a new implant for thoracolumbar vertebral body replacement. Eur Spine J 10:30–37PubMedCrossRef Knop C, Lange U, Bastian L, Oeser M, Blauth M (2001) Biomechanical compression tests with a new implant for thoracolumbar vertebral body replacement. Eur Spine J 10:30–37PubMedCrossRef
15.
go back to reference Kostuik JP, Shapiro MB (2003) Open surgical treatment of osteoporotic fractures and deformity of the spine. Instr Course Lect 52:569–578PubMed Kostuik JP, Shapiro MB (2003) Open surgical treatment of osteoporotic fractures and deformity of the spine. Instr Course Lect 52:569–578PubMed
16.
go back to reference Kurth AA, Pfeilschifter J (2007) Diagnosis and treatment of postmenopausal osteoporosis and osteoporosis in men. German Guidelines Update 2006. Orthopade 36:683–690PubMedCrossRef Kurth AA, Pfeilschifter J (2007) Diagnosis and treatment of postmenopausal osteoporosis and osteoporosis in men. German Guidelines Update 2006. Orthopade 36:683–690PubMedCrossRef
17.
go back to reference Lange U, Edeling S, Knop C, Bastian L, Oeser M, Krettek C, Blauth M (2007) Anterior vertebral body replacement with a titanium implant of adjustable height: a prospective clinical study. Eur Spine J 16:161–172PubMedCrossRef Lange U, Edeling S, Knop C, Bastian L, Oeser M, Krettek C, Blauth M (2007) Anterior vertebral body replacement with a titanium implant of adjustable height: a prospective clinical study. Eur Spine J 16:161–172PubMedCrossRef
18.
go back to reference Lowe TG, Hashim S, Wilson LA, O’Brien MF, Smith DA, Diekmann MJ, Trommeter J (2004) A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support. Spine (Phila Pa 1976) 29:2389–2394CrossRef Lowe TG, Hashim S, Wilson LA, O’Brien MF, Smith DA, Diekmann MJ, Trommeter J (2004) A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support. Spine (Phila Pa 1976) 29:2389–2394CrossRef
19.
go back to reference McArthur N, Kasperk C, Baier M, Tanner M, Gritzbach B, Schoierer O, Rothfischer W, Krohmer G, Hillmeier J, Kock HJ, Meeder PJ, Huber FX (2009) 1150 kyphoplasties over 7 years: indications, techniques, and intraoperative complications. Orthopedics 32:90PubMed McArthur N, Kasperk C, Baier M, Tanner M, Gritzbach B, Schoierer O, Rothfischer W, Krohmer G, Hillmeier J, Kock HJ, Meeder PJ, Huber FX (2009) 1150 kyphoplasties over 7 years: indications, techniques, and intraoperative complications. Orthopedics 32:90PubMed
20.
go back to reference Oda I, Cunningham BW, Abumi K, Kaneda K, McAfee PC (1999) The stability of reconstruction methods after thoracolumbar total spondylectomy. An in vitro investigation. Spine (Phila Pa 1976) 24:1634–1638CrossRef Oda I, Cunningham BW, Abumi K, Kaneda K, McAfee PC (1999) The stability of reconstruction methods after thoracolumbar total spondylectomy. An in vitro investigation. Spine (Phila Pa 1976) 24:1634–1638CrossRef
21.
go back to reference Pflugmacher R, Schleicher P, Schaefer J, Scholz M, Ludwig K, Khodadadyan-Klostermann C, Haas NP, Kandziora F (2004) Biomechanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine 41. Spine(Phila Pa 1976) 29:1413–1419CrossRef Pflugmacher R, Schleicher P, Schaefer J, Scholz M, Ludwig K, Khodadadyan-Klostermann C, Haas NP, Kandziora F (2004) Biomechanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine 41. Spine(Phila Pa 1976) 29:1413–1419CrossRef
22.
go back to reference Schultheiss M, Sarkar M, Arand M, Kramer M, Wilke HJ, Kinzl L, Hartwig E (2005) Solvent-preserved, bovine cancellous bone blocks used for reconstruction of thoracolumbar fractures in minimally invasive spinal surgery-first clinical results. Eur Spine J 14:192–196PubMedCrossRef Schultheiss M, Sarkar M, Arand M, Kramer M, Wilke HJ, Kinzl L, Hartwig E (2005) Solvent-preserved, bovine cancellous bone blocks used for reconstruction of thoracolumbar fractures in minimally invasive spinal surgery-first clinical results. Eur Spine J 14:192–196PubMedCrossRef
23.
go back to reference Tan JS, Bailey CS, Dvorak MF, Fisher CG, Cripton PA, Oxland TR (2007) Cement augmentation of vertebral screws enhances the interface strength between interbody device and vertebral body. Spine (Phila Pa 1976) 32:334–341CrossRef Tan JS, Bailey CS, Dvorak MF, Fisher CG, Cripton PA, Oxland TR (2007) Cement augmentation of vertebral screws enhances the interface strength between interbody device and vertebral body. Spine (Phila Pa 1976) 32:334–341CrossRef
24.
go back to reference Tan JS, Singh S, Zhu QA, Dvorak MF, Fisher CG, Oxland TR (2008) The effect of cement augmentation and extension of posterior instrumentation on stabilization and adjacent level effects in the elderly spine. Spine (Phila Pa 1976) 33:2728–2740CrossRef Tan JS, Singh S, Zhu QA, Dvorak MF, Fisher CG, Oxland TR (2008) The effect of cement augmentation and extension of posterior instrumentation on stabilization and adjacent level effects in the elderly spine. Spine (Phila Pa 1976) 33:2728–2740CrossRef
25.
go back to reference Ulmar B, Richter M, Kelsch G, Cakir B, Puhl W, Huch K (2005) Distractible vertebral body replacement for the thoracic and lumbar spine. Acta Orthop Belg 71:467–471PubMed Ulmar B, Richter M, Kelsch G, Cakir B, Puhl W, Huch K (2005) Distractible vertebral body replacement for the thoracic and lumbar spine. Acta Orthop Belg 71:467–471PubMed
26.
go back to reference Vieweg U, Solch O, Kalff R (2003) Vertebral body replacement system Synex in unstable burst fractures of the thoracic and lumbar spine—a retrospective study with 30 patients. Zentralbl Neurochir 64:58–64PubMedCrossRef Vieweg U, Solch O, Kalff R (2003) Vertebral body replacement system Synex in unstable burst fractures of the thoracic and lumbar spine—a retrospective study with 30 patients. Zentralbl Neurochir 64:58–64PubMedCrossRef
27.
go back to reference Wuisman PI, van DM, Staal H, Van Royen BJ (2000) Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: an innovative technique. Eur Spine J 9:528–533PubMedCrossRef Wuisman PI, van DM, Staal H, Van Royen BJ (2000) Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: an innovative technique. Eur Spine J 9:528–533PubMedCrossRef
Metadata
Title
Anterior vertebroplasty of adjacent levels after vertebral body replacement
Authors
Florian Geiger
Konstantinos Kafchitsas
Michael Rauschmann
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 8/2011
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1766-x

Other articles of this Issue 8/2011

European Spine Journal 8/2011 Go to the issue