Skip to main content
Top
Published in: European Radiology 11/2005

01-11-2005 | Vascular-Interventional

Accuracy of biopsy needle navigation using the Medarpa system—computed tomography reality superimposed on the site of intervention

Authors: M. Fawad Khan, Selami Dogan, Adel Maataoui, Jessen Gurung, Mirko Schiemann, Hanns Ackermann, Stefan Wesarg, Georgios Sakas, Thomas J. Vogl

Published in: European Radiology | Issue 11/2005

Login to get access

Abstract

The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54–9.51 mm) and 7.05±1.33 mm for group B (range 4.10–9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique.
Literature
1.
go back to reference Kato A, Yoshimine T, Hayakawa T et al (1991) A frameless, armless navigational system for computer-assisted neurosurgery. Technical note. J Neurosurg 74:845–849 Kato A, Yoshimine T, Hayakawa T et al (1991) A frameless, armless navigational system for computer-assisted neurosurgery. Technical note. J Neurosurg 74:845–849
2.
go back to reference Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg Spine 92:175–180 Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg Spine 92:175–180
3.
go back to reference Foley KT, Smith MM (1996) Image-guided spine surgery. Neurosurg Clin N Am 7:171–186PubMed Foley KT, Smith MM (1996) Image-guided spine surgery. Neurosurg Clin N Am 7:171–186PubMed
4.
go back to reference Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (1999) Accurate pedicle screw insertion under the control of a computer-assisted image guiding system: laboratory test and clinical study. J Orthop Sci 4:197–206CrossRefPubMed Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (1999) Accurate pedicle screw insertion under the control of a computer-assisted image guiding system: laboratory test and clinical study. J Orthop Sci 4:197–206CrossRefPubMed
5.
go back to reference Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235–240; discussion 241CrossRefPubMed Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235–240; discussion 241CrossRefPubMed
6.
go back to reference Smith KR, Frank KJ, Bucholz RD (1994) The NeuroStation—a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. Comput Med Imaging Graph 18:247–256 Smith KR, Frank KJ, Bucholz RD (1994) The NeuroStation—a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. Comput Med Imaging Graph 18:247–256
7.
go back to reference Sandeman DR, Gill SS (1995) The impact of interactive image guided surgery: the Bristol experience with the ISG/elekta viewing wand. Acta Neurochir Suppl (Wien) 64:54–58 Sandeman DR, Gill SS (1995) The impact of interactive image guided surgery: the Bristol experience with the ISG/elekta viewing wand. Acta Neurochir Suppl (Wien) 64:54–58
8.
go back to reference Tirakotai W, Sure U, Benes L, Krischek B, Bien S, Bertalanffy H (2003) Image-guided transsylvian, transinsular approach for insular cavernous angiomas. Neurosurgery 53:1299–1304; discussion 1304–1295CrossRef Tirakotai W, Sure U, Benes L, Krischek B, Bien S, Bertalanffy H (2003) Image-guided transsylvian, transinsular approach for insular cavernous angiomas. Neurosurgery 53:1299–1304; discussion 1304–1295CrossRef
9.
go back to reference Tang J, Cleary K (2003) Breakdown of tracking accuracy for electromagnetically guided abdominal interventions. Computer assisted radiology and surgery 2003. In: Lemke HU, Vannier MW, Inamura K, Farman AG, Doi K, Reiber JHC (eds) Proc. 17th CARS, pp 452–459 Tang J, Cleary K (2003) Breakdown of tracking accuracy for electromagnetically guided abdominal interventions. Computer assisted radiology and surgery 2003. In: Lemke HU, Vannier MW, Inamura K, Farman AG, Doi K, Reiber JHC (eds) Proc. 17th CARS, pp 452–459
10.
go back to reference Schwarz Y, Mehta AC, Ernst A et al (2003) Electromagnetic navigation during flexible bronchoscopy. Respiration 70:516–522 Schwarz Y, Mehta AC, Ernst A et al (2003) Electromagnetic navigation during flexible bronchoscopy. Respiration 70:516–522
11.
go back to reference Sindwani R, Metson R (2004) Impact of image guidance on complications during osteoplastic frontal sinus surgery. Otolaryngol Head Neck Surg 131:150–155 Sindwani R, Metson R (2004) Impact of image guidance on complications during osteoplastic frontal sinus surgery. Otolaryngol Head Neck Surg 131:150–155
12.
go back to reference Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine 25:2637–2645CrossRefPubMed Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine 25:2637–2645CrossRefPubMed
13.
go back to reference Foley KT, Simon DA, Rampersaud YR (2001) Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 26:347–351PubMed Foley KT, Simon DA, Rampersaud YR (2001) Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 26:347–351PubMed
14.
go back to reference Holzknecht N, Helmberger T, Schoepf UJ et al (2001) Evaluation of an electromagnetic virtual target system (CT-guide) for CT-guided interventions. Rofo Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr 173:612–618 Holzknecht N, Helmberger T, Schoepf UJ et al (2001) Evaluation of an electromagnetic virtual target system (CT-guide) for CT-guided interventions. Rofo Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr 173:612–618
15.
go back to reference R Bucholz, Marzouk K, A Levy (1999) Image guidance and the operating microscope: stealth and neural navigation. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme Medical Publishers, Inc., New York R Bucholz, Marzouk K, A Levy (1999) Image guidance and the operating microscope: stealth and neural navigation. In: Alexander E III, Maciunas RJ (eds) Advanced neurosurgical navigation. Thieme Medical Publishers, Inc., New York
16.
go back to reference Tirakotai W, Riegel T, Sure U, Bozinov O, Hellwig D, Bertalanffy H (2004) Clinical application of neuro-navigation in a series of single burr-hole procedures. Zentralbl Neurochir 65:57–64CrossRefPubMed Tirakotai W, Riegel T, Sure U, Bozinov O, Hellwig D, Bertalanffy H (2004) Clinical application of neuro-navigation in a series of single burr-hole procedures. Zentralbl Neurochir 65:57–64CrossRefPubMed
18.
go back to reference Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg Spine 99:257–263 Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg Spine 99:257–263
19.
20.
go back to reference Schwald BF, Pedro M (2004) Learning of rigid point-based marker models for tracking with stereo camera systems. In: Brunnett G (ed) u.a.:Virtuelle und Erweiterte Realität 2004. 1. Workshop der GIFachgruppe VR/AR. Shaker, Aachen, pp 23–34 Schwald BF, Pedro M (2004) Learning of rigid point-based marker models for tracking with stereo camera systems. In: Brunnett G (ed) u.a.:Virtuelle und Erweiterte Realität 2004. 1. Workshop der GIFachgruppe VR/AR. Shaker, Aachen, pp 23–34
21.
go back to reference Schwald B, Malerczyk C (2002) Controlling virtual worlds using interaction spheres. In: Vidal CA (ed) 5th Symposium on virtual reality (SVR). Brazilian Computer Society, Fortaleza, Brazil Schwald B, Malerczyk C (2002) Controlling virtual worlds using interaction spheres. In: Vidal CA (ed) 5th Symposium on virtual reality (SVR). Brazilian Computer Society, Fortaleza, Brazil
22.
go back to reference Wesarg S, Lauer TH, Firle EA, Dold C (2003) Several marker segmentation techniques for use with a medical AR system—a comparison. Computer assisted radiology and surgery 2003. In: Lemke HU, Vannier MW, Inamura K, Farman AG, Doi K, Reiber JHC (eds) Proc. 17th CARS, p 1303 Wesarg S, Lauer TH, Firle EA, Dold C (2003) Several marker segmentation techniques for use with a medical AR system—a comparison. Computer assisted radiology and surgery 2003. In: Lemke HU, Vannier MW, Inamura K, Farman AG, Doi K, Reiber JHC (eds) Proc. 17th CARS, p 1303
23.
go back to reference Schwald BS, Seibert H (2004) Registration tasks for a hybrid tracking system for medical augmented reality. In: Skala V (ed) European Association for Computer Graphics (Eurographics): J WSCG Proc Plzen, vol 12 no. 3, S411–S418 University of West Bohemia Schwald BS, Seibert H (2004) Registration tasks for a hybrid tracking system for medical augmented reality. In: Skala V (ed) European Association for Computer Graphics (Eurographics): J WSCG Proc Plzen, vol 12 no. 3, S411–S418 University of West Bohemia
24.
go back to reference Gumprecht HK, Widenka DC, Lumenta CB (1999) BrainLab VectorVision neuronavigation system: technology and clinical experiences in 131 cases. Neurosurgery 44:97–104 (discussion 104–105)PubMed Gumprecht HK, Widenka DC, Lumenta CB (1999) BrainLab VectorVision neuronavigation system: technology and clinical experiences in 131 cases. Neurosurgery 44:97–104 (discussion 104–105)PubMed
25.
go back to reference Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258CrossRefPubMed Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258CrossRefPubMed
26.
go back to reference Merloz P, Tonetti J, Pittet L et al (1998) Computer-assisted spine surgery. Comput Aided Surg 3:297–305PubMed Merloz P, Tonetti J, Pittet L et al (1998) Computer-assisted spine surgery. Comput Aided Surg 3:297–305PubMed
27.
go back to reference Hummel J, Figl M, Kollmann C, Bergmann H, Birkfellner W (2002) Evaluation of a miniature electromagnetic position tracker. Med Phys 29:2205–2212CrossRefPubMed Hummel J, Figl M, Kollmann C, Bergmann H, Birkfellner W (2002) Evaluation of a miniature electromagnetic position tracker. Med Phys 29:2205–2212CrossRefPubMed
28.
go back to reference Birkfellner W, Watzinger F, Wanschitz F et al (1998) Systematic distortions in magnetic position digitizers. Med Phys 25:2242–2248 Birkfellner W, Watzinger F, Wanschitz F et al (1998) Systematic distortions in magnetic position digitizers. Med Phys 25:2242–2248
29.
go back to reference Barnett GH, Steiner CP, Weisenberger J (1995) Adaptation of personal projection television to a head-mounted display for intra-operative viewing of neuroimaging. J Image Guid Surg 1:109–112 Barnett GH, Steiner CP, Weisenberger J (1995) Adaptation of personal projection television to a head-mounted display for intra-operative viewing of neuroimaging. J Image Guid Surg 1:109–112
30.
go back to reference Germano IM, Queenan JV (1998) Clinical experience with intracranial brain needle biopsy using frameless surgical navigation. Comput Aided Surg 3:33–39 Germano IM, Queenan JV (1998) Clinical experience with intracranial brain needle biopsy using frameless surgical navigation. Comput Aided Surg 3:33–39
31.
go back to reference Bolger C, Wigfield C, Melkent T, Smith K (1999) Frameless stereotaxy and anterior cervical surgery. Comput Aided Surg 4:322–327 Bolger C, Wigfield C, Melkent T, Smith K (1999) Frameless stereotaxy and anterior cervical surgery. Comput Aided Surg 4:322–327
32.
go back to reference Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF (1995) Clinical use of a frameless stereotactic arm: results of 325 cases. J Neurosurg 83:197–205PubMed Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF (1995) Clinical use of a frameless stereotactic arm: results of 325 cases. J Neurosurg 83:197–205PubMed
33.
go back to reference Montaudon M, Latrabe V, Pariente A, Corneloup O, Begueret H, Laurent F (2004) Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions. Eur Radiol 14:1234–1240 Montaudon M, Latrabe V, Pariente A, Corneloup O, Begueret H, Laurent F (2004) Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions. Eur Radiol 14:1234–1240
34.
go back to reference Bale RJ, Lottersberger C, Vogele M et al (2002) A novel vacuum device for extremity immobilisation during digital angiography: preliminary clinical experiences. Eur Radiol 12:2890–2894PubMed Bale RJ, Lottersberger C, Vogele M et al (2002) A novel vacuum device for extremity immobilisation during digital angiography: preliminary clinical experiences. Eur Radiol 12:2890–2894PubMed
35.
go back to reference Deurloo EE, Gilhuijs KG, Schultze Kool LJ, Muller SH (2001) Displacement of breast tissue and needle deviations during stereotactic procedures. Invest Radiol 36:347–353 Deurloo EE, Gilhuijs KG, Schultze Kool LJ, Muller SH (2001) Displacement of breast tissue and needle deviations during stereotactic procedures. Invest Radiol 36:347–353
36.
go back to reference Helbich TH, Matzek W, Fuchsjager MH (2004) Stereotactic and ultrasound-guided breast biopsy. Eur Radiol 14:383–393CrossRefPubMed Helbich TH, Matzek W, Fuchsjager MH (2004) Stereotactic and ultrasound-guided breast biopsy. Eur Radiol 14:383–393CrossRefPubMed
37.
go back to reference Tokuda J, Morikawa S, Dohi T, Hata N (2004) Motion tracking in MR-guided liver therapy by using navigator echoes and projection profile matching. Acad Radiol 11:111–120 Tokuda J, Morikawa S, Dohi T, Hata N (2004) Motion tracking in MR-guided liver therapy by using navigator echoes and projection profile matching. Acad Radiol 11:111–120
38.
go back to reference Sequeiros RB, Hyvonen P, Sequeiros AB et al (2003) MR imaging-guided laser ablation of osteoid osteomas with use of optical instrument guidance at 0.23 T. Eur Radiol 13:2309–2314CrossRefPubMed Sequeiros RB, Hyvonen P, Sequeiros AB et al (2003) MR imaging-guided laser ablation of osteoid osteomas with use of optical instrument guidance at 0.23 T. Eur Radiol 13:2309–2314CrossRefPubMed
Metadata
Title
Accuracy of biopsy needle navigation using the Medarpa system—computed tomography reality superimposed on the site of intervention
Authors
M. Fawad Khan
Selami Dogan
Adel Maataoui
Jessen Gurung
Mirko Schiemann
Hanns Ackermann
Stefan Wesarg
Georgios Sakas
Thomas J. Vogl
Publication date
01-11-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 11/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2708-y

Other articles of this Issue 11/2005

European Radiology 11/2005 Go to the issue