Skip to main content
Top
Published in: European Radiology 11/2005

01-11-2005 | Pediatric

CT dose reduction in children

Author: Peter Vock

Published in: European Radiology | Issue 11/2005

Login to get access

Abstract

World wide, the number of CT studies in children and the radiation exposure by CT increases. The same energy dose has a greater biological impact in children than in adults, and scan parameters have to be adapted to the smaller diameter of the juvenile body. Based on seven rules, a practical approach to paediatric CT is shown: Justification and patient preparation are important steps before scanning, and they differ from the preparation of adult patients. The subsequent choice of scan parameters aims at obtaining the minimal signal-to-noise ratio and volume coverage needed in a specific medical situation; exposure can be divided in two aspects: the CT dose index determining energy deposition per rotation and the dose-length product (DLP) determining the volume dose. DLP closely parallels the effective dose, the best parameter of the biological impact. Modern scanners offer dose modulation to locally minimise exposure while maintaining image quality. Beyond the selection of the physical parameters, the dose can be kept low by scanning the minimal length of the body and by avoiding any non-qualified repeated scanning of parts of the body. Following these rules, paediatric CT examinations of good quality can be obtained at a reasonable cost of radiation exposure.
Literature
1.
go back to reference Beaconsfield T, Nicholson R, Thornton A, Al-Kutoubi A (1998) Would thyroid and breast shielding be beneficial in CT of the head? Eur Radiol 8:664–667CrossRefPubMed Beaconsfield T, Nicholson R, Thornton A, Al-Kutoubi A (1998) Would thyroid and breast shielding be beneficial in CT of the head? Eur Radiol 8:664–667CrossRefPubMed
2.
go back to reference Boone JM, Geraghty EM, Seibert JA, Wootton-Gorges SL (2003) Dose reduction in pediatric CT: a rational approach. Radiology 228:352–360PubMed Boone JM, Geraghty EM, Seibert JA, Wootton-Gorges SL (2003) Dose reduction in pediatric CT: a rational approach. Radiology 228:352–360PubMed
3.
go back to reference Brenner DJ, Elliston CD, Hall EJ, Berdon WE (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176:289–296 Brenner DJ, Elliston CD, Hall EJ, Berdon WE (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176:289–296
4.
go back to reference Brenner DJ (2002) Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative. Pediatr Radiol 32:228–231CrossRefPubMed Brenner DJ (2002) Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative. Pediatr Radiol 32:228–231CrossRefPubMed
5.
go back to reference Brenner DJ, Doll R, Goodhead DT, Hall EJ, Land CE, Little JB, Lubin JH, Preston DL, Preston RJ, Puskin JS, Ron E, Sachs RK, Samet JM, Setlow RB, Zaider M (2003) Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci U S A 100:13761–13766CrossRefPubMed Brenner DJ, Doll R, Goodhead DT, Hall EJ, Land CE, Little JB, Lubin JH, Preston DL, Preston RJ, Puskin JS, Ron E, Sachs RK, Samet JM, Setlow RB, Zaider M (2003) Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci U S A 100:13761–13766CrossRefPubMed
6.
go back to reference Brenner DJ, Elliston CD (2004) Estimated radiation risk potentially associated with full-body CT screening. Radiology 232:735–738PubMed Brenner DJ, Elliston CD (2004) Estimated radiation risk potentially associated with full-body CT screening. Radiology 232:735–738PubMed
7.
go back to reference Brnic Z, Vekic B, Hebrang A, Anic P (2003) Efficacy of breast shielding during CT of the head. Eur Radiol 13:2436–2440CrossRefPubMed Brnic Z, Vekic B, Hebrang A, Anic P (2003) Efficacy of breast shielding during CT of the head. Eur Radiol 13:2436–2440CrossRefPubMed
8.
go back to reference Chapple CL, Willis S, Frame J (2002) Effective dose in paediatric computed tomography. Phys Med Biol 47:107–115CrossRefPubMed Chapple CL, Willis S, Frame J (2002) Effective dose in paediatric computed tomography. Phys Med Biol 47:107–115CrossRefPubMed
9.
go back to reference Cody DD, Moxley DM, Krugh KT, O’Daniel JC, Wagner LK, Eftekhari F (2004) Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients. Am J Roentgenol 182:849–859 Cody DD, Moxley DM, Krugh KT, O’Daniel JC, Wagner LK, Eftekhari F (2004) Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients. Am J Roentgenol 182:849–859
10.
go back to reference Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton GA, Thomas SR, Frush DP (2001) Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large children’s hospital. Am J Roentgenol 176:303–306PubMed Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton GA, Thomas SR, Frush DP (2001) Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large children’s hospital. Am J Roentgenol 176:303–306PubMed
11.
go back to reference European Commission (2000) European guidelines on quality criteria for computed tomography, EUR 16262EN. Office for Official Publications of the European Communities, Luxembourg European Commission (2000) European guidelines on quality criteria for computed tomography, EUR 16262EN. Office for Official Publications of the European Communities, Luxembourg
12.
go back to reference Fricke BL, Donnelly LF, Frush DP, Yoshizumi T, Varchena V, Poe SA, Lucaya J (2003) In-plane bismuth breast shields for pediatric CT: effects on radiation dose and image quality using experimental and clinical data. Am J Roentgenol 180:407–411 Fricke BL, Donnelly LF, Frush DP, Yoshizumi T, Varchena V, Poe SA, Lucaya J (2003) In-plane bismuth breast shields for pediatric CT: effects on radiation dose and image quality using experimental and clinical data. Am J Roentgenol 180:407–411
13.
go back to reference Frush DP, Soden B, Frush KS, Lowry C (2002) Improved pediatric multidetector CT using a size-based color-coded format. Am J Roentgenol 178:721–726PubMed Frush DP, Soden B, Frush KS, Lowry C (2002) Improved pediatric multidetector CT using a size-based color-coded format. Am J Roentgenol 178:721–726PubMed
14.
go back to reference Frush DP (2002) Pediatric CT: practical approach to diminish the radiation dose. Pediatr Radiol 32:714–717CrossRefPubMed Frush DP (2002) Pediatric CT: practical approach to diminish the radiation dose. Pediatr Radiol 32:714–717CrossRefPubMed
15.
go back to reference Frush DP, Donnelly LF, Rosen NS (2003) Computed tomography and radiation risks: what pediatric health care providers should know. Pediatrics 112:951–957CrossRefPubMed Frush DP, Donnelly LF, Rosen NS (2003) Computed tomography and radiation risks: what pediatric health care providers should know. Pediatrics 112:951–957CrossRefPubMed
16.
go back to reference Golding SJ, Shrimpton PC (2002) Commentary. Radiation dose in CT: are we meeting the challenge? Br J Radiol 75:1–4PubMed Golding SJ, Shrimpton PC (2002) Commentary. Radiation dose in CT: are we meeting the challenge? Br J Radiol 75:1–4PubMed
17.
go back to reference Hidajat N, Schroder RJ, Vogl T, Schedel H, Felix R (1996) The efficacy of lead shielding in patient dosage reduction in computed tomography (German). Rofo 165:462–465PubMed Hidajat N, Schroder RJ, Vogl T, Schedel H, Felix R (1996) The efficacy of lead shielding in patient dosage reduction in computed tomography (German). Rofo 165:462–465PubMed
18.
go back to reference Hohl C, Mahnken AH, Klotz E, Das M, Stargardt A, Mühlenbruch G, Schmidt T, Günther RW, Wildberger JE (2005) Radiation dose reduction to the male gonads during MDCT: the effectiveness of a lead shield. Am J Roentgenol 184:128–130 Hohl C, Mahnken AH, Klotz E, Das M, Stargardt A, Mühlenbruch G, Schmidt T, Günther RW, Wildberger JE (2005) Radiation dose reduction to the male gonads during MDCT: the effectiveness of a lead shield. Am J Roentgenol 184:128–130
19.
go back to reference Hopper KD, King SH, Lobell ME, TenHave TR, Weyver JS (1997) Rhe breast: in-plane x-ray protection during diagnostic thoracic CT-shielding with bismuth radioprotective garments. Radiology 205:853–858PubMed Hopper KD, King SH, Lobell ME, TenHave TR, Weyver JS (1997) Rhe breast: in-plane x-ray protection during diagnostic thoracic CT-shielding with bismuth radioprotective garments. Radiology 205:853–858PubMed
20.
go back to reference Huda W, Gkanatsios NA (1997) Effective dose and energy imparted in diagnostic radiology. Med Phys 24:1311–1318CrossRefPubMed Huda W, Gkanatsios NA (1997) Effective dose and energy imparted in diagnostic radiology. Med Phys 24:1311–1318CrossRefPubMed
21.
go back to reference Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430–435PubMed Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430–435PubMed
22.
23.
go back to reference International Commission on Radiological Protection (1990) 1990 recommendations of the international commission on radiological protection. ICRP publication 60. Pergamon Press, Oxford International Commission on Radiological Protection (1990) 1990 recommendations of the international commission on radiological protection. ICRP publication 60. Pergamon Press, Oxford
24.
go back to reference Kalender WA, SeisslerW, Klotz E, Vock P (1990) Spiral volumetric CT with single breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 176:181–183PubMed Kalender WA, SeisslerW, Klotz E, Vock P (1990) Spiral volumetric CT with single breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 176:181–183PubMed
25.
go back to reference Lee CI, Haims AH, Monico EP, Brink JA, Forman HP (2004) Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology 231:393–398PubMed Lee CI, Haims AH, Monico EP, Brink JA, Forman HP (2004) Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology 231:393–398PubMed
26.
go back to reference Mettler FA, Wiest PW, Locken JA, Kelsey CA (2000) CT scanning: patterns of use and dose. J Radiol Prot 20:353–359CrossRefPubMed Mettler FA, Wiest PW, Locken JA, Kelsey CA (2000) CT scanning: patterns of use and dose. J Radiol Prot 20:353–359CrossRefPubMed
27.
go back to reference Mini RL, Vock P, Mury R, Schneeberger PP (1995) Radiation exposure of patients who undergo CT of the trunk. Radiology 195:557–562PubMed Mini RL, Vock P, Mury R, Schneeberger PP (1995) Radiation exposure of patients who undergo CT of the trunk. Radiology 195:557–562PubMed
28.
go back to reference Nickoloff EL, Alderson PO (2001) Radiation exposures to patients from CT. Reality, public perception, and policy. Am J Roentgenol 177:285–287 Nickoloff EL, Alderson PO (2001) Radiation exposures to patients from CT. Reality, public perception, and policy. Am J Roentgenol 177:285–287
30.
go back to reference Pages J, Buls N, Osteaux M (2003) CT doses in children: a multicentre study. Br J Radiol 76:803–811CrossRefPubMed Pages J, Buls N, Osteaux M (2003) CT doses in children: a multicentre study. Br J Radiol 76:803–811CrossRefPubMed
31.
go back to reference Paterson A, Frush DP, Donnelly LF (2001) Helical CT of the body: are settings adjusted for pediatric patients? Am J Roentgenol 176:297–301 Paterson A, Frush DP, Donnelly LF (2001) Helical CT of the body: are settings adjusted for pediatric patients? Am J Roentgenol 176:297–301
32.
go back to reference Pierce DA, Preston DL (2000) Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res 154:178–186PubMed Pierce DA, Preston DL (2000) Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res 154:178–186PubMed
33.
go back to reference Price R, Halson P, Sampson M (1999) Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield. Br J Radiol 72:489–494PubMed Price R, Halson P, Sampson M (1999) Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield. Br J Radiol 72:489–494PubMed
34.
go back to reference Ravenel JG, Scalzetti EM, Huda W, Garrisi W (2001) Radiation exposure and image quality in chest CT examinations. Am J Roentgenol 177:279–284 Ravenel JG, Scalzetti EM, Huda W, Garrisi W (2001) Radiation exposure and image quality in chest CT examinations. Am J Roentgenol 177:279–284
35.
go back to reference Semelka R (2005) Radiation risk from CT scans: a call for patient-focused imaging. Medscape Radiol 6(01) 1/26/2005 Semelka R (2005) Radiation risk from CT scans: a call for patient-focused imaging. Medscape Radiol 6(01) 1/26/2005
36.
go back to reference Shrimpton PC, Edyvean S (1998) CT scanner dosimetry. Br J Radiol 71:1–3 Shrimpton PC, Edyvean S (1998) CT scanner dosimetry. Br J Radiol 71:1–3
37.
go back to reference Shrimpton PC, Wall BF (2000) Reference doses for paediatric computed tomography. Radiat Prot Dosim 90:249–252 Shrimpton PC, Wall BF (2000) Reference doses for paediatric computed tomography. Radiat Prot Dosim 90:249–252
38.
go back to reference Shrimpton PC, Hillier MC, Lewis MA, Dunn M (2005) Doses from computed tomography (CT) examinations in the UK-2003 review. UK Health protection agency, NRPB-W67 Shrimpton PC, Hillier MC, Lewis MA, Dunn M (2005) Doses from computed tomography (CT) examinations in the UK-2003 review. UK Health protection agency, NRPB-W67
39.
go back to reference Slovis TL (2003) Children, computed tomography radiation dose, and the as low as reasonably achievable (ALARA) concept. Pediatrics 112:971–972CrossRefPubMed Slovis TL (2003) Children, computed tomography radiation dose, and the as low as reasonably achievable (ALARA) concept. Pediatrics 112:971–972CrossRefPubMed
40.
go back to reference Suess C, Chen X (2002) Dose optimization in pediatric CT: current technology and future innovations. Pediatr Radiol 32:729–734CrossRefPubMed Suess C, Chen X (2002) Dose optimization in pediatric CT: current technology and future innovations. Pediatr Radiol 32:729–734CrossRefPubMed
41.
go back to reference United Nations Scientific Committee on the Effects of Atomic Radiation (2000) UNSCEAR 2000 report to the general assembly, vol I: sources. United Nations, New York United Nations Scientific Committee on the Effects of Atomic Radiation (2000) UNSCEAR 2000 report to the general assembly, vol I: sources. United Nations, New York
42.
go back to reference Verdun FR, Lepori D, Monnin P, Valley JF, Schnyder P, Gudinchet F (2004) Management of patient dose and image noise in routine pediatric CT abdominal examinations. Eur Radiol 14:835–841CrossRefPubMed Verdun FR, Lepori D, Monnin P, Valley JF, Schnyder P, Gudinchet F (2004) Management of patient dose and image noise in routine pediatric CT abdominal examinations. Eur Radiol 14:835–841CrossRefPubMed
43.
go back to reference Vock P (2002) CT radiation exposure in children: consequences of the American discussion for Europe (German). Radiologe 42:697–702CrossRefPubMed Vock P (2002) CT radiation exposure in children: consequences of the American discussion for Europe (German). Radiologe 42:697–702CrossRefPubMed
44.
go back to reference Wall BF (2001) Diagnostic reference levels-the way forward. Commentary. Br J Radiol 74:785–788PubMed Wall BF (2001) Diagnostic reference levels-the way forward. Commentary. Br J Radiol 74:785–788PubMed
45.
go back to reference Ware DE, Huda W, Mergo PJ, Litwiller AL (1999) Radiation effective doses to patients undergoing abdominal CT examinations. 210:645–650 Ware DE, Huda W, Mergo PJ, Litwiller AL (1999) Radiation effective doses to patients undergoing abdominal CT examinations. 210:645–650
Metadata
Title
CT dose reduction in children
Author
Peter Vock
Publication date
01-11-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 11/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2856-0

Other articles of this Issue 11/2005

European Radiology 11/2005 Go to the issue