Skip to main content
Top
Published in: Cardiovascular Intervention and Therapeutics 1/2016

01-01-2016 | Case Report

A rare instructive complication of balloon catheter fracture during percutaneous coronary intervention

Authors: Tetsuya Nomura, Yusuke Higuchi, Taku Kato, Natsuya Keira, Tetsuya Tatsumi

Published in: Cardiovascular Intervention and Therapeutics | Issue 1/2016

Login to get access

Abstract

The entrapment, fracture, and dislodgement of catheterization devices during percutaneous coronary intervention (PCI) are rare complications, for which cardiac surgery is sometimes required. Here, we encountered a rare but instructive case of balloon catheter fracture during PCI. Although there have been some reports of guidewire fracture in PCI, reports on balloon catheter fracture are very rare to our knowledge. A simulation test to examine the mechanism of balloon catheter fracture revealed that overuse of the balloon catheter, both for kissing balloon inflation and balloon anchor, was highly likely to have been the cause of the fracture.
Literature
1.
go back to reference Balbi M, Bezante GP, Brunelli C, Rollando D. Guide wire fracture during percutaneous transluminal coronary angioplasty: possible causes and management. Interact CardioVasc Thorac Surg. 2010;10:992–4.PubMedCrossRef Balbi M, Bezante GP, Brunelli C, Rollando D. Guide wire fracture during percutaneous transluminal coronary angioplasty: possible causes and management. Interact CardioVasc Thorac Surg. 2010;10:992–4.PubMedCrossRef
2.
go back to reference Singh D, Darbari A. Retrieval of trapped and broken guide wire with immediate rescue off-pump coronary bypass surgery. Interact CardioVasc Thorac Surg. 2014;19:529–31.PubMedCrossRef Singh D, Darbari A. Retrieval of trapped and broken guide wire with immediate rescue off-pump coronary bypass surgery. Interact CardioVasc Thorac Surg. 2014;19:529–31.PubMedCrossRef
3.
go back to reference Trehan V, Mukhopadhyay S, Yusuf J, C Ramgasetty U, Mukherjee S, Arora R. Intracoronary fracture and embolization of a coronary angioplasty balloon catheter: retrieval by a simple technique. Catheter Cardiovasc Interv. 2003;58:473–7.PubMedCrossRef Trehan V, Mukhopadhyay S, Yusuf J, C Ramgasetty U, Mukherjee S, Arora R. Intracoronary fracture and embolization of a coronary angioplasty balloon catheter: retrieval by a simple technique. Catheter Cardiovasc Interv. 2003;58:473–7.PubMedCrossRef
Metadata
Title
A rare instructive complication of balloon catheter fracture during percutaneous coronary intervention
Authors
Tetsuya Nomura
Yusuke Higuchi
Taku Kato
Natsuya Keira
Tetsuya Tatsumi
Publication date
01-01-2016
Publisher
Springer Japan
Published in
Cardiovascular Intervention and Therapeutics / Issue 1/2016
Print ISSN: 1868-4300
Electronic ISSN: 1868-4297
DOI
https://doi.org/10.1007/s12928-015-0322-8

Other articles of this Issue 1/2016

Cardiovascular Intervention and Therapeutics 1/2016 Go to the issue