Abstract

Paravalvular aortic regurgitation (PAR) following transcatheter aortic valve implantation (TAVI) is a complication which is associated with increased late mortality. When PAR is severe and refractory to standard corrective measures, case reports have now described the successful use of vascular plugs to treat PAR as a follow-up procedure. We describe a case of vascular plug implantation to reduce PAR immediately after implantation of the transcatheter aortic valve prosthesis.
Literature
1.
go back to reference Kodali SK, Williams MR, Smith CR, Svensson LG, Webb JG, Makkar RR. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med. 2012;366(18):686–1695.CrossRef Kodali SK, Williams MR, Smith CR, Svensson LG, Webb JG, Makkar RR. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med. 2012;366(18):686–1695.CrossRef
2.
go back to reference Whisenant B, Jones K, Horton KD, Horton S. Device closure of paravalvular defects following transcatheter aortic valve replacement with the Edwards Sapien valve. Catheter Cardiovasc Interv. 2013;81(5):901–5.PubMedCrossRef Whisenant B, Jones K, Horton KD, Horton S. Device closure of paravalvular defects following transcatheter aortic valve replacement with the Edwards Sapien valve. Catheter Cardiovasc Interv. 2013;81(5):901–5.PubMedCrossRef
3.
go back to reference Poliacikova P, Hildick-Smith D. Paravalvular leak closure for persisting aortic regurgitation after implantation of the corevalve transcatheter valve. Catheter Cardiovasc Interv. 2013; In press. Poliacikova P, Hildick-Smith D. Paravalvular leak closure for persisting aortic regurgitation after implantation of the corevalve transcatheter valve. Catheter Cardiovasc Interv. 2013; In press.
4.
go back to reference Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lempos PA, Fraccaro C. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61(15):1585.PubMedCrossRef Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lempos PA, Fraccaro C. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61(15):1585.PubMedCrossRef
5.
go back to reference Daneault B, Koss E, Hahn RT, Kodali S, Williams MR, Genereux P. Efficacy and safety of post dilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement. Circ Cardiovasc Interv. 2013;6(1):85–91.PubMedCrossRef Daneault B, Koss E, Hahn RT, Kodali S, Williams MR, Genereux P. Efficacy and safety of post dilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement. Circ Cardiovasc Interv. 2013;6(1):85–91.PubMedCrossRef
6.
go back to reference Lerakis S, Hayek SS, Douglas PS. Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation. 2013;127(3):397–407.PubMedCrossRef Lerakis S, Hayek SS, Douglas PS. Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation. 2013;127(3):397–407.PubMedCrossRef
7.
go back to reference Tam D. Paravalvular leak after transcatheter aortic valve implantation: trading one disease for another?. Expert Rev Cardiovasc Ther. 2014; 12(4). Tam D. Paravalvular leak after transcatheter aortic valve implantation: trading one disease for another?. Expert Rev Cardiovasc Ther. 2014; 12(4).
8.
go back to reference Martinez CA, O’Neill B, Singh V, O’Neill WW. Transseptal approach for the management of paravalvular regurgitation after transcatheter aortic valve replacement. Catheter Cardiovasc Interv. 2013;82(4):587–91. Martinez CA, O’Neill B, Singh V, O’Neill WW. Transseptal approach for the management of paravalvular regurgitation after transcatheter aortic valve replacement. Catheter Cardiovasc Interv. 2013;82(4):587–91.
9.
go back to reference Estevez-Loureiro R, Salgado-Fernandez J, Vazquez-Gonzalez N. Percutaneous closure of paravalvular leaks after transcatheter aortic valve implantation with Edwards SAPIEN prosthesis: a report of two cases. J Invasive Cardiol. 2013;25:92–5.PubMed Estevez-Loureiro R, Salgado-Fernandez J, Vazquez-Gonzalez N. Percutaneous closure of paravalvular leaks after transcatheter aortic valve implantation with Edwards SAPIEN prosthesis: a report of two cases. J Invasive Cardiol. 2013;25:92–5.PubMed
10.
go back to reference Smolka S, Pysz P, Wojakowski W, Ochala A, Peszek-przybyala E, Roleder T. Clinical manifestations of heart failure abate with transcatheter aortic paravalvular leak closure using amplatzer vascular plug II and III devices. J Invasive Cardiol. 2013; 25(5). Smolka S, Pysz P, Wojakowski W, Ochala A, Peszek-przybyala E, Roleder T. Clinical manifestations of heart failure abate with transcatheter aortic paravalvular leak closure using amplatzer vascular plug II and III devices. J Invasive Cardiol. 2013; 25(5).
11.
go back to reference Luu J, Ali O, Feldman T, Price M. Percutaneous closure of paravalvular leak after transcatheter aortic valve replacement. Am Coll Cardiol Intv 2013; 6(2). Luu J, Ali O, Feldman T, Price M. Percutaneous closure of paravalvular leak after transcatheter aortic valve replacement. Am Coll Cardiol Intv 2013; 6(2).
12.
go back to reference Sinning JM, Vasa-Nicotera M, Werner N, Nickenig G, Hammerstingl C. Interventional closure of paravalvular leakage after transcatheter aortic valve implantation. Eur Heart J. 2012;33:2498.PubMedCrossRef Sinning JM, Vasa-Nicotera M, Werner N, Nickenig G, Hammerstingl C. Interventional closure of paravalvular leakage after transcatheter aortic valve implantation. Eur Heart J. 2012;33:2498.PubMedCrossRef
13.
go back to reference Behan M, Haworth P, Hutchinson N, et al. Percutaneous aortic valve implants under sedation: our initial experience. Catheter Cardiovasc Interv. 2008;72:1012–5.PubMedCrossRef Behan M, Haworth P, Hutchinson N, et al. Percutaneous aortic valve implants under sedation: our initial experience. Catheter Cardiovasc Interv. 2008;72:1012–5.PubMedCrossRef
14.
go back to reference Kliger C, Eiros R, Isasti G, Einhorn B, Jelnin V, Cohen H, Kronzon I, Perk G, Fontana GP, Ruiz CE. Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure. Eur Heart J. 2013;34:638–49. doi:10.1093/eurheartj/ehs347.PubMedCrossRef Kliger C, Eiros R, Isasti G, Einhorn B, Jelnin V, Cohen H, Kronzon I, Perk G, Fontana GP, Ruiz CE. Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure. Eur Heart J. 2013;34:638–49. doi:10.​1093/​eurheartj/​ehs347.PubMedCrossRef
Metadata
Title
Transcatheter aortic valve implantation and simultaneous closure of associated paravalvular leak
Authors
James Cockburn
Thomas Charlton
Arri Gomes
Uday Trivedi
David Hildick-Smith
Publication date
01-01-2016
Publisher
Springer Japan
Published in
Cardiovascular Intervention and Therapeutics / Issue 1/2016
Print ISSN: 1868-4300
Electronic ISSN: 1868-4297
DOI
https://doi.org/10.1007/s12928-015-0318-4

Other articles of this Issue 1/2016

Cardiovascular Intervention and Therapeutics 1/2016 Go to the issue