Skip to main content
Top
Published in: European Radiology 11/2009

01-11-2009 | Computer Applications

A comparative study on manual and automatic slice-to-volume registration of CT images

Authors: Laura Frühwald, Joachim Kettenbach, Michael Figl, Johann Hummel, Helmar Bergmann, Wolfgang Birkfellner

Published in: European Radiology | Issue 11/2009

Login to get access

Abstract

In order to assess the clinical relevance of a slice-to-volume registration algorithm, this technique was compared to manual registration. Reformatted images obtained from a diagnostic CT examination of the lower abdomen were reviewed and manually registered by 41 individuals. The results were refined by the algorithm. Furthermore, a fully automatic registration of the single slices to the whole CT examination, without manual initialization, was also performed. The manual registration error for rotation and translation was found to be 2.7±2.8 ° and 4.0±2.5 mm. The automated registration algorithm significantly reduced the registration error to 1.6±2.6 ° and 1.3±1.6 mm (p = 0.01). In 3 of 41 (7.3%) registration cases, the automated registration algorithm failed completely. On average, the time required for manual registration was 213±197 s; automatic registration took 82±15 s. Registration was also performed without any human interaction. The resulting registration error of the algorithm without manual pre-registration was found to be 2.9±2.9 ° and 1.1±0.2 mm. Here, a registration took 91±6 s, on average. Overall, the automated registration algorithm improved the accuracy of manual registration by 59% in rotation and 325% in translation. The absolute values are well within a clinically relevant range.
Literature
1.
go back to reference Katada K, Kato R, Anno H, Ogura Y, Koga S, Ida Y, Sato M, Nonomura K (1996) Guidance with real-time CT fluoroscopy. Radiology 200:851–856PubMed Katada K, Kato R, Anno H, Ogura Y, Koga S, Ida Y, Sato M, Nonomura K (1996) Guidance with real-time CT fluoroscopy. Radiology 200:851–856PubMed
2.
go back to reference Carlson SK, Bender CE, Classic KL, Zink FE, Quam JP, Ward EM, Oberg AL (2001) Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology 219:515–520PubMed Carlson SK, Bender CE, Classic KL, Zink FE, Quam JP, Ward EM, Oberg AL (2001) Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology 219:515–520PubMed
3.
go back to reference Carlson SK, Felmlee JP, Bender CE, Ehman RL, Classic KL, Hoskin TL, Harmsen WS, Hu HH (2005) CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 237:701–708CrossRefPubMed Carlson SK, Felmlee JP, Bender CE, Ehman RL, Classic KL, Hoskin TL, Harmsen WS, Hu HH (2005) CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 237:701–708CrossRefPubMed
4.
go back to reference Puri A, Shingade VU, Agarwal MG, Anchan C Juvekar S, Desai S, Jambhekar NA (2006) CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases. Skeletal Radiol 35:138–143CrossRefPubMed Puri A, Shingade VU, Agarwal MG, Anchan C Juvekar S, Desai S, Jambhekar NA (2006) CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases. Skeletal Radiol 35:138–143CrossRefPubMed
5.
go back to reference Shin HJ, Amaral JG, Armstrong D, Chait PG, Temple MJ, John P, Smith CR, Taylor G, Connolly BL (2007) Image-guided percutaneous biopsy of musculoskeletal lesions in children. Pediatr Radiol 37:362–369CrossRefPubMed Shin HJ, Amaral JG, Armstrong D, Chait PG, Temple MJ, John P, Smith CR, Taylor G, Connolly BL (2007) Image-guided percutaneous biopsy of musculoskeletal lesions in children. Pediatr Radiol 37:362–369CrossRefPubMed
6.
go back to reference Jelinek JS, Murphey MD, Welker JA, Henschaw RM, Kransdorf MJ, Shmookler BM, Malawer MM (2002) Diagnosis of primary bone tumors with image-guided percutaneous biopsy: experience with 110 tumors. Radiology 223:731–737CrossRefPubMed Jelinek JS, Murphey MD, Welker JA, Henschaw RM, Kransdorf MJ, Shmookler BM, Malawer MM (2002) Diagnosis of primary bone tumors with image-guided percutaneous biopsy: experience with 110 tumors. Radiology 223:731–737CrossRefPubMed
7.
go back to reference Lemieux L, Jagoe R, Fish DR, Kitchen ND, Thomas DG (1994) A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs. Med Phys 21:1749–1760CrossRefPubMed Lemieux L, Jagoe R, Fish DR, Kitchen ND, Thomas DG (1994) A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs. Med Phys 21:1749–1760CrossRefPubMed
8.
go back to reference Byrne JV, Colominas C, Hipwell J, Cox T, Noble JA, Penney GP, Hawkes DJ (2004) Assessment of a technique for 2D-3D registration of cerebral intra-arterial angiography. Brit J Radiol 77:123–128CrossRefPubMed Byrne JV, Colominas C, Hipwell J, Cox T, Noble JA, Penney GP, Hawkes DJ (2004) Assessment of a technique for 2D-3D registration of cerebral intra-arterial angiography. Brit J Radiol 77:123–128CrossRefPubMed
9.
go back to reference Kuenzler T, Grezdo J, Bogner J, Birkfellner W, Georg D (2007) Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment. Phys Med Biol 52:2157–2170CrossRef Kuenzler T, Grezdo J, Bogner J, Birkfellner W, Georg D (2007) Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment. Phys Med Biol 52:2157–2170CrossRef
10.
11.
go back to reference Birkfellner W, Seemann R, Figl M, Hummel J, Ede C, Homolka P, Yang X, Niederer P, Bergmann H (2005) Wobbled splatting—a fast perspective volume rendering method for simulation of X-ray images from CT. Phys Med Biol 50:N73–N84CrossRefPubMed Birkfellner W, Seemann R, Figl M, Hummel J, Ede C, Homolka P, Yang X, Niederer P, Bergmann H (2005) Wobbled splatting—a fast perspective volume rendering method for simulation of X-ray images from CT. Phys Med Biol 50:N73–N84CrossRefPubMed
12.
go back to reference Fei B, Duerk JL, Boll DT, Lewin JS, Wilson DL (2003) Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer. IEEE Trans Med Imaging 22:515–525CrossRefPubMed Fei B, Duerk JL, Boll DT, Lewin JS, Wilson DL (2003) Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer. IEEE Trans Med Imaging 22:515–525CrossRefPubMed
13.
go back to reference Birkfellner W, Figl M, Kettenbach J, Hummel J, Homolka P, Schernthaner R, Nau T, Bergmann H (2007) Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images. Med Phys 34:246–255CrossRefPubMed Birkfellner W, Figl M, Kettenbach J, Hummel J, Homolka P, Schernthaner R, Nau T, Bergmann H (2007) Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images. Med Phys 34:246–255CrossRefPubMed
14.
go back to reference Press WH, Teukolsky SA, Vetterling WT, Flannery BP (1992) Numerical recipes in C. The Art of Scientific Computing, Cambridge University Press Press WH, Teukolsky SA, Vetterling WT, Flannery BP (1992) Numerical recipes in C. The Art of Scientific Computing, Cambridge University Press
15.
go back to reference Robb RA, Hanson DP, Karwoski RA, Larson AG, Workman EL, Stacy MC (1989) Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis. Comput Med Imaging Graph 13:433–454CrossRefPubMed Robb RA, Hanson DP, Karwoski RA, Larson AG, Workman EL, Stacy MC (1989) Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis. Comput Med Imaging Graph 13:433–454CrossRefPubMed
16.
go back to reference Fitzpatrick JM, West JB, Maurer CR Jr (1998) Predicting Error in rigid-body point-based registration. IEEE Trans Med Imaging 17:694–702CrossRefPubMed Fitzpatrick JM, West JB, Maurer CR Jr (1998) Predicting Error in rigid-body point-based registration. IEEE Trans Med Imaging 17:694–702CrossRefPubMed
17.
go back to reference Paulson EK, Sheafor DH, Enterline DS, Page McAdams H, Yoshizumi TT (2001) CT-Fluoroscopy - guided interventional procedures: Techniques and radiation dose to radiologists. Radiology 220:161–167PubMed Paulson EK, Sheafor DH, Enterline DS, Page McAdams H, Yoshizumi TT (2001) CT-Fluoroscopy - guided interventional procedures: Techniques and radiation dose to radiologists. Radiology 220:161–167PubMed
Metadata
Title
A comparative study on manual and automatic slice-to-volume registration of CT images
Authors
Laura Frühwald
Joachim Kettenbach
Michael Figl
Johann Hummel
Helmar Bergmann
Wolfgang Birkfellner
Publication date
01-11-2009
Publisher
Springer-Verlag
Published in
European Radiology / Issue 11/2009
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1452-0

Other articles of this Issue 11/2009

European Radiology 11/2009 Go to the issue