Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 2/2018

Open Access 01-02-2018 | Laryngology

Virtual 3D planning of tracheostomy placement and clinical applicability of 3D cannula design: a three-step study

Authors: Bertram J. de Kleijn, Joep Kraeima, Jasper E. Wachters, Bernard F. A. M. van der Laan, Jan Wedman, M. J. H. Witjes, Gyorgy B. Halmos

Published in: European Archives of Oto-Rhino-Laryngology | Issue 2/2018

Login to get access

Abstract

Aim

We aimed to investigate the potential of 3D virtual planning of tracheostomy tube placement and 3D cannula design to prevent tracheostomy complications due to inadequate cannula position.

Materials and methods

3D models of commercially available cannula were positioned in 3D models of the airway. In study (1), a cohort that underwent tracheostomy between 2013 and 2015 was selected (n = 26). The cannula was virtually placed in the airway in the pre-operative CT scan and its position was compared to the cannula position on post-operative CT scans. In study (2), a cohort with neuromuscular disease (n = 14) was analyzed. Virtual cannula placing was performed in CT scans and tested if problems could be anticipated. Finally (3), for a patient with Duchenne muscular dystrophy and complications of conventional tracheostomy cannula, a patient-specific cannula was 3D designed, fabricated, and placed.

Results

(1) The 3D planned and post-operative tracheostomy position differed significantly. (2) Three groups of patients were identified: (A) normal anatomy; (B) abnormal anatomy, commercially available cannula fits; and (C) abnormal anatomy, custom-made cannula, may be necessary. (3) The position of the custom-designed cannula was optimal and the trachea healed.

Conclusions

Virtual planning of the tracheostomy did not correlate with actual cannula position. Identifying patients with abnormal airway anatomy in whom commercially available cannula cannot be optimally positioned is advantageous. Patient-specific cannula design based on 3D virtualization of the airway was beneficial in a patient with abnormal airway anatomy.
Literature
1.
go back to reference Meinesz AF, Bladder G, Goorhuis JF, Fock JM, Staal-Schreinemachers AL, Zijlstra JG, Wijkstra PJ (2007) 18 years experience with mechanical ventilation in patients with Duchenne muscular dystrophy. Ned Tijdschr Geneeskd 151:1830–1833PubMed Meinesz AF, Bladder G, Goorhuis JF, Fock JM, Staal-Schreinemachers AL, Zijlstra JG, Wijkstra PJ (2007) 18 years experience with mechanical ventilation in patients with Duchenne muscular dystrophy. Ned Tijdschr Geneeskd 151:1830–1833PubMed
2.
go back to reference Ilan O, Gross M, Zaltzman Y, Sasson A, Marcus EL (2015) Diagnosis and conservative management of late tracheotomy complications in chronic ventilator-dependent patients. Head Neck 37:716–721CrossRefPubMed Ilan O, Gross M, Zaltzman Y, Sasson A, Marcus EL (2015) Diagnosis and conservative management of late tracheotomy complications in chronic ventilator-dependent patients. Head Neck 37:716–721CrossRefPubMed
3.
go back to reference Bekele A, Tesfaye S (2015) Fatal Tracheo-Innominate artery fistula associated with a tracheostomy tube at a teaching university hospital in addis ababa: case report and review of literature. Ethiop Med J 53:155–158PubMed Bekele A, Tesfaye S (2015) Fatal Tracheo-Innominate artery fistula associated with a tracheostomy tube at a teaching university hospital in addis ababa: case report and review of literature. Ethiop Med J 53:155–158PubMed
4.
go back to reference Saito T, Sawabata N, Matsumura T, Nozaki S, Fujimura H, Shinno S (2006) Tracheo-arterial fistula in tracheostomy patients with Duchenne muscular dystrophy. Brain Dev 28:223–227CrossRefPubMed Saito T, Sawabata N, Matsumura T, Nozaki S, Fujimura H, Shinno S (2006) Tracheo-arterial fistula in tracheostomy patients with Duchenne muscular dystrophy. Brain Dev 28:223–227CrossRefPubMed
5.
go back to reference Dirven R, Wouters Y, Vreeken R, Maal TJ, Marres HA (2012) Three-dimensional stereophotogrammetrical analysis of peristomal fixation of adhesive base plates during hands-free speech among laryngectomised patients related to tracheostoma volumes. Clin Otolaryngol 37:124–129CrossRefPubMed Dirven R, Wouters Y, Vreeken R, Maal TJ, Marres HA (2012) Three-dimensional stereophotogrammetrical analysis of peristomal fixation of adhesive base plates during hands-free speech among laryngectomised patients related to tracheostoma volumes. Clin Otolaryngol 37:124–129CrossRefPubMed
6.
go back to reference Fujimoto T, Imai K, Matsumoto H, Sakamoto H, Nakano T (2011) Tracheobronchial anomalies in syndromic craniosynostosis with 3-dimensional CT image and bronchoscopy. J Craniofac Surg 22:1579–1583CrossRefPubMed Fujimoto T, Imai K, Matsumoto H, Sakamoto H, Nakano T (2011) Tracheobronchial anomalies in syndromic craniosynostosis with 3-dimensional CT image and bronchoscopy. J Craniofac Surg 22:1579–1583CrossRefPubMed
7.
go back to reference Schepers RH, Raghoebar GM, Vissink A et al (2013) Fully 3-dimensional digitally planned reconstruction of a mandible with a free vascularized fibula and immediate placement of an implant-supported prosthetic construction. Head Neck 35:E109–E114CrossRefPubMed Schepers RH, Raghoebar GM, Vissink A et al (2013) Fully 3-dimensional digitally planned reconstruction of a mandible with a free vascularized fibula and immediate placement of an implant-supported prosthetic construction. Head Neck 35:E109–E114CrossRefPubMed
8.
go back to reference Barrera JE (2014) Virtual surgical planning improves surgical outcome measures in obstructive sleep apnea surgery. Laryngoscope 124:1259–1266CrossRefPubMed Barrera JE (2014) Virtual surgical planning improves surgical outcome measures in obstructive sleep apnea surgery. Laryngoscope 124:1259–1266CrossRefPubMed
9.
go back to reference Kaye R, Goldstein T, Zeltsman D, Grande DA, Smith LP (2016) Three dimensional printing: a review on the utility within medicine and otolaryngology. Int J Pediatr Otorhinolaryngol 89:145–148CrossRefPubMed Kaye R, Goldstein T, Zeltsman D, Grande DA, Smith LP (2016) Three dimensional printing: a review on the utility within medicine and otolaryngology. Int J Pediatr Otorhinolaryngol 89:145–148CrossRefPubMed
Metadata
Title
Virtual 3D planning of tracheostomy placement and clinical applicability of 3D cannula design: a three-step study
Authors
Bertram J. de Kleijn
Joep Kraeima
Jasper E. Wachters
Bernard F. A. M. van der Laan
Jan Wedman
M. J. H. Witjes
Gyorgy B. Halmos
Publication date
01-02-2018
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 2/2018
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-017-4819-x

Other articles of this Issue 2/2018

European Archives of Oto-Rhino-Laryngology 2/2018 Go to the issue