Skip to main content
Top
Published in: BMC Oral Health 1/2023

Open Access 01-12-2023 | Veneer | Research

Age and sex related change in tooth enamel thickness of maxillary incisors measured by cone beam computed tomography

Authors: Abdulsalam Rashid Al-Zahawi, Rawa Omar Ibrahim, Ranjdar Mahmood Talabani, Shilan Nawzad Dawood, Didar Sadiq Hama Garib, Ako Omer Abdalla

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

To measure adequate enamel thickness of maxillary incisors in planning enamel reduction for a porcelain laminate veneer restoration in relation to chronological age and sex by using cone beam computed tomography (CBCT) in an Iraqi subpopulation.

Methods

From 81 CBCT images, 324 maxillary incisors were examined. Enamel thickness was measured at both mesial and distal regions of the tooth in three different levels: cervical, middle, and incisal (occlusal) 1/3 at a sagittal section. Measurements were made for the following tooth areas using CBCT: facial enamel thickness at 1, 3, and 5 mm from the cementoenamel junction (CEJ), palatal enamel thickness at 5 mm from the CEJ (5 mm P), facial and palatal enamel thickness at the incisal edge (IFP), mid incisal enamel thickness (IET), and the incisal edge enamel-pulp distance (IEPD). Relationships of enamel thickness with age and sex were evaluated using Independent t-test, Mann–Whitney U-test and the Pearson correlation coefficient, a simple linear regression analysis used for statistical analysis.

Results

Significant differences (P < 0.05) were found in terms of an inverse association between enamel thickness and chronological age at all measurements above the CEJ and the regression model for the mid-incisal enamel thickness was (R2 of 0.4). In contrast, there was an increase in IFP, palatal, and IPED enamel thickness with age. Also, significant differences were found in enamel thickness between males and females, the enamel being thicker in females in relation to facial enamel thickness, enamel palatal thickness above CEJ and IET, while for IEPD, the enamel thickness was greater in males compared to females.

Conclusion

The measurements for enamel thickness outcome variables in relation to chronological age revealed significant differences for each measured distance and there were statistically significant differences in enamel thickness between males and females at all measurements except at IFP. These results demonstrate that CBCT can be used for noninvasive, accurate measurements of enamel thickness in both sex.
Literature
1.
go back to reference Mohamed M. Effect of preparation depth on the fracture resistance of two monolithic ceramic laminate veneers. Egypt Dent J. 2022;68(3):2509–17.CrossRef Mohamed M. Effect of preparation depth on the fracture resistance of two monolithic ceramic laminate veneers. Egypt Dent J. 2022;68(3):2509–17.CrossRef
2.
go back to reference Zhu J, Gao J, Jia L, Tan X, Xie C, Yu H. Shear bond strength of ceramic laminate veneers to finishing surfaces with different percentages of preserved enamel under a digital guided method. BMC Oral Health. 2022;22(1):1–11.CrossRef Zhu J, Gao J, Jia L, Tan X, Xie C, Yu H. Shear bond strength of ceramic laminate veneers to finishing surfaces with different percentages of preserved enamel under a digital guided method. BMC Oral Health. 2022;22(1):1–11.CrossRef
3.
go back to reference Burke FT. Survival rates for porcelain laminate veneers with special reference to the effect of preparation in dentin: a literature review. J Esthet Restor Dent. 2012;24(4):257–65.CrossRefPubMed Burke FT. Survival rates for porcelain laminate veneers with special reference to the effect of preparation in dentin: a literature review. J Esthet Restor Dent. 2012;24(4):257–65.CrossRefPubMed
4.
go back to reference Ge C, Green CC, Sederstrom D, McLaren EA, White SN. Effect of porcelain and enamel thickness on porcelain veneer failure loads in vitro. J Prosthet Dent. 2014;111(5):380–7.CrossRefPubMed Ge C, Green CC, Sederstrom D, McLaren EA, White SN. Effect of porcelain and enamel thickness on porcelain veneer failure loads in vitro. J Prosthet Dent. 2014;111(5):380–7.CrossRefPubMed
5.
go back to reference Piemjai M, Arksornnukit M. Compressive fracture resistance of porcelain laminates bonded to enamel or dentin with four adhesive systems. J Prosthodont. 2007;16(6):457–64.CrossRefPubMed Piemjai M, Arksornnukit M. Compressive fracture resistance of porcelain laminates bonded to enamel or dentin with four adhesive systems. J Prosthodont. 2007;16(6):457–64.CrossRefPubMed
6.
go back to reference Oguro R, Nakajima M, Seki N, Sadr A, Tagami J, Sumi Y. The role of enamel thickness and refractive index on human tooth colour. J Dent. 2016;51:36–44.CrossRefPubMed Oguro R, Nakajima M, Seki N, Sadr A, Tagami J, Sumi Y. The role of enamel thickness and refractive index on human tooth colour. J Dent. 2016;51:36–44.CrossRefPubMed
7.
go back to reference Cuy JL, Mann AB, Livi KJ, Teaford MF, Weihs TP. Nanoindentation mapping of the mechanical properties of human molar tooth enamel. Arch Oral Biol. 2002;47(4):281–91.CrossRefPubMed Cuy JL, Mann AB, Livi KJ, Teaford MF, Weihs TP. Nanoindentation mapping of the mechanical properties of human molar tooth enamel. Arch Oral Biol. 2002;47(4):281–91.CrossRefPubMed
8.
go back to reference Atsu SS, Aka PS, Kucukesmen HC, Kilicarslan MA, Atakan C. Age-related changes in tooth enamel as measured by electron microscopy: Implications for porcelain laminate veneers. J Prosthet Dent. 2005;94(4):336–41.CrossRefPubMed Atsu SS, Aka PS, Kucukesmen HC, Kilicarslan MA, Atakan C. Age-related changes in tooth enamel as measured by electron microscopy: Implications for porcelain laminate veneers. J Prosthet Dent. 2005;94(4):336–41.CrossRefPubMed
10.
go back to reference Olejniczak AJ, Grine FE. Assessment of the accuracy of dental enamel thickness measurements using microfocal X-ray computed tomography. Anat Rec A Discov Mol Cell Evol Biol. 2006;288A(3):263–75.CrossRef Olejniczak AJ, Grine FE. Assessment of the accuracy of dental enamel thickness measurements using microfocal X-ray computed tomography. Anat Rec A Discov Mol Cell Evol Biol. 2006;288A(3):263–75.CrossRef
11.
go back to reference Grine FE, Stevens NJ, Jungers WL. An evaluation of dental radiograph accuracy in the measurement of enamel thickness. Arch Oral Biol. 2001;46(12):1117–25.CrossRefPubMed Grine FE, Stevens NJ, Jungers WL. An evaluation of dental radiograph accuracy in the measurement of enamel thickness. Arch Oral Biol. 2001;46(12):1117–25.CrossRefPubMed
12.
go back to reference Plotino G, Grande NM, Pecci R, Bedini R, Pameijer CH, Somma F. Three-dimensional imaging using microcomputed tomography for studying tooth macromorphology. J Am Dent Assoc. 2006;137(11):1555–61.CrossRefPubMed Plotino G, Grande NM, Pecci R, Bedini R, Pameijer CH, Somma F. Three-dimensional imaging using microcomputed tomography for studying tooth macromorphology. J Am Dent Assoc. 2006;137(11):1555–61.CrossRefPubMed
13.
go back to reference Baumgaertel S, Palomo JM, Palomo L, Hans MG. Reliability and accuracy of cone-beam computed tomography dental measurements. Am J Orthod Dentofacial Orthop. 2009;136(1):19–25.CrossRefPubMed Baumgaertel S, Palomo JM, Palomo L, Hans MG. Reliability and accuracy of cone-beam computed tomography dental measurements. Am J Orthod Dentofacial Orthop. 2009;136(1):19–25.CrossRefPubMed
14.
go back to reference Brokos YP, Stavridakis M, Bortolotto T, Krejci I. Evaluation of enamel thickness of upper anterior teeth in different age groups by Dental Cone Beam Computed Tomography Scan, in vivo. Int J Adv case reports. 2015;2(23):1396–409. Brokos YP, Stavridakis M, Bortolotto T, Krejci I. Evaluation of enamel thickness of upper anterior teeth in different age groups by Dental Cone Beam Computed Tomography Scan, in vivo. Int J Adv case reports. 2015;2(23):1396–409.
15.
go back to reference Talabani RM, Abdalrahman KO, Abdul RJ, Babarasul DO, Hilmi KS. Evaluation of Radix Entomolaris and Middle Mesial Canal in Mandibular Permanent First Molars in an Iraqi Subpopulation Using Cone-Beam Computed Tomography. Biomed Res Int. 2022;11(2022):7825948. https://doi.org/10.1155/2022/7825948. PMID:35860794;PMCID:PMC9293536.CrossRef Talabani RM, Abdalrahman KO, Abdul RJ, Babarasul DO, Hilmi KS. Evaluation of Radix Entomolaris and Middle Mesial Canal in Mandibular Permanent First Molars in an Iraqi Subpopulation Using Cone-Beam Computed Tomography. Biomed Res Int. 2022;11(2022):7825948. https://​doi.​org/​10.​1155/​2022/​7825948. PMID:35860794;PMCID:PMC9293536.CrossRef
16.
go back to reference Ferrari M, Patroni S, Balleri P. Measurement of enamel thickness in relation to reduction for etched laminate veneers. Int J Periodont Rest Dent. 1992;12:407–13. Ferrari M, Patroni S, Balleri P. Measurement of enamel thickness in relation to reduction for etched laminate veneers. Int J Periodont Rest Dent. 1992;12:407–13.
17.
go back to reference Kedici P, Atsu S, Gokdemir K, Sarikaya Y, Gurbuz F. Micrometric measurements by scanning electron microscope (SEM) for dental age estimation in adults. J Forensic Odontostomatol. 2000;18:22–6.PubMed Kedici P, Atsu S, Gokdemir K, Sarikaya Y, Gurbuz F. Micrometric measurements by scanning electron microscope (SEM) for dental age estimation in adults. J Forensic Odontostomatol. 2000;18:22–6.PubMed
18.
go back to reference Pahlevan A, Mirzaee M, Yassine E, Ranjbar Omrany L, Hasani Tabatabaee M, Kermanshah H, Arami S, Abbasi M. Enamel thickness after preparation of tooth for porcelain laminate. J Dent (Tehran). 2014;11(4):428–32.PubMed Pahlevan A, Mirzaee M, Yassine E, Ranjbar Omrany L, Hasani Tabatabaee M, Kermanshah H, Arami S, Abbasi M. Enamel thickness after preparation of tooth for porcelain laminate. J Dent (Tehran). 2014;11(4):428–32.PubMed
19.
go back to reference Belgın CA, Serindere G, Orhan K. Accuracy and reliability of enamel and dentin thickness measurements on micro-computed tomography and digital periapical radiographs. J Forensic Radiol Imaging. 2019;18:32–6.CrossRef Belgın CA, Serindere G, Orhan K. Accuracy and reliability of enamel and dentin thickness measurements on micro-computed tomography and digital periapical radiographs. J Forensic Radiol Imaging. 2019;18:32–6.CrossRef
20.
go back to reference Akli E, Araujo EA, Kim KB, McCray JF, Hudson MJ. Enamel thickness of maxillary canines evaluated with microcomputed tomography scans. Am J Orthod Dentofacial Orthop. 2020;158(3):391–9.CrossRefPubMed Akli E, Araujo EA, Kim KB, McCray JF, Hudson MJ. Enamel thickness of maxillary canines evaluated with microcomputed tomography scans. Am J Orthod Dentofacial Orthop. 2020;158(3):391–9.CrossRefPubMed
21.
go back to reference Feeney RNM, Zermeno JP, Reid DJ, Nakashima S, Sano H, Bahar A, Hublin JJ, Smith TM. Enamel thickness in Asian human canines and premolars. Anthropol Sci. 2010;118(3):191–8.CrossRef Feeney RNM, Zermeno JP, Reid DJ, Nakashima S, Sano H, Bahar A, Hublin JJ, Smith TM. Enamel thickness in Asian human canines and premolars. Anthropol Sci. 2010;118(3):191–8.CrossRef
22.
go back to reference Salam E, khalifa A, Hassouna D. Odontometric analysis using CBCT for sexual dimorphism in Egyptian-Fayoum population in case of normal occlusion. Egypt Dent J. 2021;67:1319–32.CrossRef Salam E, khalifa A, Hassouna D. Odontometric analysis using CBCT for sexual dimorphism in Egyptian-Fayoum population in case of normal occlusion. Egypt Dent J. 2021;67:1319–32.CrossRef
23.
go back to reference Wang Y, He S, Yu L, Li J, Chen S. Accuracy of volumetric measurement of teeth in vivo based on cone beam computer tomography. Orthod Craniofac Res. 2011;14(4):206–12.CrossRefPubMed Wang Y, He S, Yu L, Li J, Chen S. Accuracy of volumetric measurement of teeth in vivo based on cone beam computer tomography. Orthod Craniofac Res. 2011;14(4):206–12.CrossRefPubMed
24.
go back to reference Cherukara GP, Seymour KG, Samarawickrama DY, Zou L. A study into the variations in the labial reduction of teeth prepared to receive porcelain veneers– a comparison of three clinical techniques. Br Dent J. 2002;192:401–4.CrossRefPubMed Cherukara GP, Seymour KG, Samarawickrama DY, Zou L. A study into the variations in the labial reduction of teeth prepared to receive porcelain veneers– a comparison of three clinical techniques. Br Dent J. 2002;192:401–4.CrossRefPubMed
25.
go back to reference Brunton PA, Aminian A, Wilson NH. Tooth preparation techniques for porcelain laminate veneers. Br Dent J. 2000;189:260–2.CrossRefPubMed Brunton PA, Aminian A, Wilson NH. Tooth preparation techniques for porcelain laminate veneers. Br Dent J. 2000;189:260–2.CrossRefPubMed
26.
go back to reference Cherukara GP, Seymour KG, Zou L, Samarawickrama DY. Geographic distribution of porcelain veneer preparation depth with various clinical techniques. J Prosthet Dent. 2003;89:544–50.CrossRefPubMed Cherukara GP, Seymour KG, Zou L, Samarawickrama DY. Geographic distribution of porcelain veneer preparation depth with various clinical techniques. J Prosthet Dent. 2003;89:544–50.CrossRefPubMed
27.
go back to reference Garber DA. Rational tooth preparations for porcelain laminate veneers. Compendium. 1991;12:316–8 320.PubMed Garber DA. Rational tooth preparations for porcelain laminate veneers. Compendium. 1991;12:316–8 320.PubMed
28.
go back to reference Yu H, Zhao Y, Li J, Luo T, Gao J, Liu H, Liu W, Liu F, Zhao K, Liu F, Ma C, Setz JM, Liang S, Fan L, Gao S, Zhu Z, Shen J, Wang J, Zhu Z, Zhou X. Minimal invasive microscopic tooth preparation in esthetic restoration: a specialist consensus. Int J Oral Sci. 2019;11(3):31.CrossRefPubMedPubMedCentral Yu H, Zhao Y, Li J, Luo T, Gao J, Liu H, Liu W, Liu F, Zhao K, Liu F, Ma C, Setz JM, Liang S, Fan L, Gao S, Zhu Z, Shen J, Wang J, Zhu Z, Zhou X. Minimal invasive microscopic tooth preparation in esthetic restoration: a specialist consensus. Int J Oral Sci. 2019;11(3):31.CrossRefPubMedPubMedCentral
29.
go back to reference Harley KE, Ibbetson RJ. Anterior veneers for the adolescent patient: 2 Porcelain veneers and conclusions. Dent Update. 1991;18:112–6.PubMed Harley KE, Ibbetson RJ. Anterior veneers for the adolescent patient: 2 Porcelain veneers and conclusions. Dent Update. 1991;18:112–6.PubMed
30.
go back to reference Stambaugh RV, Wittrock JW. The relationship of the pulp chamber to the external surface of the tooth. J Prosthet Dent. 1977;37:537–46.CrossRefPubMed Stambaugh RV, Wittrock JW. The relationship of the pulp chamber to the external surface of the tooth. J Prosthet Dent. 1977;37:537–46.CrossRefPubMed
31.
go back to reference Talabani RM, Baban MT, Mahmood MA. Age estimation using lower permanent first molars on a panoramic radiograph: A digital image analysis. J Forensic Dent Sci. 2015;7(2):158–62.CrossRefPubMedPubMedCentral Talabani RM, Baban MT, Mahmood MA. Age estimation using lower permanent first molars on a panoramic radiograph: A digital image analysis. J Forensic Dent Sci. 2015;7(2):158–62.CrossRefPubMedPubMedCentral
Metadata
Title
Age and sex related change in tooth enamel thickness of maxillary incisors measured by cone beam computed tomography
Authors
Abdulsalam Rashid Al-Zahawi
Rawa Omar Ibrahim
Ranjdar Mahmood Talabani
Shilan Nawzad Dawood
Didar Sadiq Hama Garib
Ako Omer Abdalla
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-03639-y

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue