Background

Cadmium-zinc-telluride (CZT) cameras allow to decrease significantly the acquisition time of myocardial perfusion imaging (MPI), but the duration of the examination is still long. Therefore, this study was performed to test the feasibility of early imaging following injection of Tc-99 m sestamibi using a CZT camera.

Methods

Seventy patients underwent both an early and a delayed image acquisition after exercise stress test (n = 30), dipyridamole stress test (n = 20), and at rest (n = 20). After injection of Tc-99 m sestamibi, the early image acquisition started on average within 5 minutes for the exercise and rest groups, and 3 minutes 30 seconds for the dipyridamole group. Two independent observers evaluated image quality and extracardiac uptake on four-point scales. The difference between early and later images for each patient was scored on a five-point scale.

Results

The image quality and extracardiac uptake of early and delayed image acquisitions were not different for the three groups (P > .05). There was no significant difference between early and delayed image acquisitions in the exercise, dipyridamole, and rest groups, respectively, in 63%, 40%, and 80% of cases. In the exercise group and rest group, a defect was only present in early MPI, respectively, in 13% and 20% of cases. A defect was only present in delayed images in 10% of cases in the exercise group and in 45% of cases in the dipyridamole group.

Conclusions

There was no difference between early and later image acquisitions in terms of quality. This protocol reduces the length of the procedure for the patient. Beginning with early image acquisitions may help to overcome the artifacts that are observed at the delayed time.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sharir T, Slomka PJ, Hayes SW, DiCarli MF, Ziffer JA, Martin WH, et al. Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: Quantitative results of myocardial perfusion and left ventricular function. J Am Coll Cardiol. 2010;55:1965-74.CrossRef Sharir T, Slomka PJ, Hayes SW, DiCarli MF, Ziffer JA, Martin WH, et al. Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: Quantitative results of myocardial perfusion and left ventricular function. J Am Coll Cardiol. 2010;55:1965-74.CrossRef
2.
go back to reference Erlandsson K, Kacperski K, van Gramberg D, Hutton BF. Performance evaluation of D-SPECT: A novel SPECT system for nuclear cardiology. Phys Med Biol 2009;54:2635-49.CrossRef Erlandsson K, Kacperski K, van Gramberg D, Hutton BF. Performance evaluation of D-SPECT: A novel SPECT system for nuclear cardiology. Phys Med Biol 2009;54:2635-49.CrossRef
3.
go back to reference Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao S-S, Quality Assurance Committee of the American Society of Nuclear Cardiology. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.CrossRef Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao S-S, Quality Assurance Committee of the American Society of Nuclear Cardiology. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.CrossRef
4.
go back to reference Marshall RC, Leidholdt EM, Zhang DY, Barnett CA. Technetium-99 m hexakis 2-methoxy-2-isobutyl isonitrile and thallium-201 extraction, washout, and retention at varying coronary flow rates in rabbit heart. Circulation 1990;82:998-1007.CrossRef Marshall RC, Leidholdt EM, Zhang DY, Barnett CA. Technetium-99 m hexakis 2-methoxy-2-isobutyl isonitrile and thallium-201 extraction, washout, and retention at varying coronary flow rates in rabbit heart. Circulation 1990;82:998-1007.CrossRef
5.
go back to reference Wackers FJ, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, et al. Technetium-99 m hexakis 2-methoxyisobutylisonitrile: Human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med 1989;30:301-11. Wackers FJ, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, et al. Technetium-99 m hexakis 2-methoxyisobutylisonitrile: Human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med 1989;30:301-11.
6.
go back to reference Askew JW, Miller TD, Ruter RL, Jordan LG, Hodge DO, Gibbons RJ, et al. Early image acquisition using a solid-state cardiac camera for fast myocardial perfusion imaging. J Nucl Cardiol 2011;18:840-6.CrossRef Askew JW, Miller TD, Ruter RL, Jordan LG, Hodge DO, Gibbons RJ, et al. Early image acquisition using a solid-state cardiac camera for fast myocardial perfusion imaging. J Nucl Cardiol 2011;18:840-6.CrossRef
7.
go back to reference Henzlova MJ, Duvall WL. Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast…. J Nucl Cardiol 2015;22:523-5.CrossRef Henzlova MJ, Duvall WL. Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast…. J Nucl Cardiol 2015;22:523-5.CrossRef
8.
go back to reference Gibbons RJ, Balady GJ, Bricker JT, Chaitman BR, Fletcher GF, Froelicher VF, et al. ACC/AHA 2002 guideline update for exercise testing: Summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1997 Exercise Testing Guidelines). J Am Coll Cardiol 2002;40(8):1531-40. Gibbons RJ, Balady GJ, Bricker JT, Chaitman BR, Fletcher GF, Froelicher VF, et al. ACC/AHA 2002 guideline update for exercise testing: Summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1997 Exercise Testing Guidelines). J Am Coll Cardiol 2002;40(8):1531-40.
9.
go back to reference Gambhir SS, Berman DS, Ziffer J, Nagler M, Sandler M, Patton J, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med 2009;50:635-43.CrossRef Gambhir SS, Berman DS, Ziffer J, Nagler M, Sandler M, Patton J, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med 2009;50:635-43.CrossRef
10.
go back to reference Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S, et al. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 2008;1:156-63.CrossRef Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S, et al. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 2008;1:156-63.CrossRef
11.
go back to reference Verberne HJ, Acampa W, Anagnostopoulos C, Ballinger J, Bengel F, De Bondt P, et al. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging 2015;42:1929-40.CrossRef Verberne HJ, Acampa W, Anagnostopoulos C, Ballinger J, Bengel F, De Bondt P, et al. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging 2015;42:1929-40.CrossRef
12.
go back to reference Cerqueira MD. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the cardiac imaging committee of the council on Clinical Cardiology of the American Heart Association. Circulation 2002;105:539-42.CrossRef Cerqueira MD. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the cardiac imaging committee of the council on Clinical Cardiology of the American Heart Association. Circulation 2002;105:539-42.CrossRef
13.
go back to reference Giorgetti A, Rossi M, Stanislao M, Valle G, Bertolaccini P, Maneschi A, et al. Feasibility and diagnostic accuracy of a gated SPECT early-imaging protocol: A multicenter study of the Myoview Imaging Optimization Group. J Nucl Med 2007;48:1670-5.CrossRef Giorgetti A, Rossi M, Stanislao M, Valle G, Bertolaccini P, Maneschi A, et al. Feasibility and diagnostic accuracy of a gated SPECT early-imaging protocol: A multicenter study of the Myoview Imaging Optimization Group. J Nucl Med 2007;48:1670-5.CrossRef
14.
go back to reference Berman DS, Kang X, Tamarappoo B, Wolak A, Hayes SW, Nakazato R, et al. Stress thallium-201/rest technetium-99 m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2009;2:273-82.CrossRef Berman DS, Kang X, Tamarappoo B, Wolak A, Hayes SW, Nakazato R, et al. Stress thallium-201/rest technetium-99 m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2009;2:273-82.CrossRef
15.
go back to reference Taillefer R, Lambert R, Bisson G, Benjamin C, Phaneuf DC. Myocardial technetium 99 m-labeled sestamibi single-photon emission computed tomographic imaging in the detection of coronary artery disease: Comparison between early (15 minutes) and delayed (60 minutes) imaging. J Nucl Cardiol 1994;1:441-8.CrossRef Taillefer R, Lambert R, Bisson G, Benjamin C, Phaneuf DC. Myocardial technetium 99 m-labeled sestamibi single-photon emission computed tomographic imaging in the detection of coronary artery disease: Comparison between early (15 minutes) and delayed (60 minutes) imaging. J Nucl Cardiol 1994;1:441-8.CrossRef
16.
go back to reference Taillefer R, Dupras G, Sporn V, Rigo P, Leveille J, Boucher P, et al. Myocardial perfusion imaging with a new radiotracer, technetium-99 m-hexamibi (methoxy isobutyl isonitrile): comparison with thallium-201 imaging. Clin Nucl Med 1989;14:89-96.CrossRef Taillefer R, Dupras G, Sporn V, Rigo P, Leveille J, Boucher P, et al. Myocardial perfusion imaging with a new radiotracer, technetium-99 m-hexamibi (methoxy isobutyl isonitrile): comparison with thallium-201 imaging. Clin Nucl Med 1989;14:89-96.CrossRef
17.
go back to reference Najm YC, Maisey MN, Clarke SM, Fogelman I, Curry PV, Sowton E. Exercise myocardial perfusion scintigraphy with technetium-99 m methoxy isobutylisonitrile: A comparative study with thallium-201. Int J Cardiol 1990;26:93-102.CrossRef Najm YC, Maisey MN, Clarke SM, Fogelman I, Curry PV, Sowton E. Exercise myocardial perfusion scintigraphy with technetium-99 m methoxy isobutylisonitrile: A comparative study with thallium-201. Int J Cardiol 1990;26:93-102.CrossRef
18.
go back to reference Weinmann P, Faraggi M, Moretti JL, Hannequin P. Clinical validation of simultaneous dual-isotope myocardial scintigraphy. Eur J Nucl Med Mol Imaging 2003;30:25-31.CrossRef Weinmann P, Faraggi M, Moretti JL, Hannequin P. Clinical validation of simultaneous dual-isotope myocardial scintigraphy. Eur J Nucl Med Mol Imaging 2003;30:25-31.CrossRef
19.
go back to reference Matsunari I, Tanishima Y, Taki J, Ono K, Nishide H, Fujino S, et al. Early and delayed technetium-99 m-tetrofosmin myocardial SPECT compared in normal volunteers. J Nucl Med 1996;37:1622-6. Matsunari I, Tanishima Y, Taki J, Ono K, Nishide H, Fujino S, et al. Early and delayed technetium-99 m-tetrofosmin myocardial SPECT compared in normal volunteers. J Nucl Med 1996;37:1622-6.
20.
go back to reference Jain D, Wackers FJ, Mattera J, McMahon M, Sinusas AJ, Zaret BL. Biokinetics of technetium-99 m-tetrofosmin: myocardial perfusion imaging agent: Implications for a one-day imaging protocol. J Nucl Med 1993;34:1254-9. Jain D, Wackers FJ, Mattera J, McMahon M, Sinusas AJ, Zaret BL. Biokinetics of technetium-99 m-tetrofosmin: myocardial perfusion imaging agent: Implications for a one-day imaging protocol. J Nucl Med 1993;34:1254-9.
Metadata
Title
Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride
Authors
Celine Meyer, MD
Pierre Weinmann, MD, PhD
Publication date
01-08-2017
Publisher
Springer International Publishing
Published in
Journal of Nuclear Cardiology / Issue 4/2017
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-016-0499-y

Other articles of this Issue 4/2017

Journal of Nuclear Cardiology 4/2017 Go to the issue