Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 9/2018

01-09-2018 | Original Paper

Validation of contrast-enhanced time-resolved magnetic resonance angiography in pre-ablation planning in patients with atrial fibrillation: comparison with traditional technique

Authors: Tarek Zghaib, Adeel Shahid, Chiara Pozzessere, Kristin K. Porter, Linda C. Chu, John Eng, Hugh Calkins, Ihab R. Kamel, Saman Nazarian, Stefan L. Zimmerman

Published in: The International Journal of Cardiovascular Imaging | Issue 9/2018

Login to get access

Abstract

Bolus timing is critical to optimal magnetic resonance angiography (MRA) acquisitions but can be challenging in some patients. Our purpose was to evaluate whether contrast-enhanced time-resolved magnetic resonance angiography (TR-MRA), a dynamic multiphase sequence that does not rely on bolus timing, is a viable alternative method to conventional 3D fast-long angle shot contrast-enhanced magnetic resonance angiography (CE-MRA). Coronal subtracted conventional CE-MRA images in 50 consecutive patients presenting for pre-atrial fibrillation ablation pulmonary venous (PV) mapping were compared with 50 TR-MRA images performed in 50 subsequent patients. The TR-MRA protocol was modified to optimize spatial resolution with slightly reduced temporal resolution (6.1 s scan time). Three experienced readers evaluated each scan’s image quality and relative left atrial (LA) opacification based on a 4-point scale and diagnostic PV visualization in a binary fashion. Additionally, LA signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and PV dimensions were measured for both techniques. TR-MRA had significantly higher overall image quality (3.10 ± 0.69 vs. 2.42 ± 0.69, p < 0.0001), and LA opacification scores (3.33 ± 0.70 vs. 2.15 ± 1.13, p < 0.0001) compared to CE-MRA. The proportion of diagnostically visualized pulmonary veins was 137/150 (91%) in the CE-MRA group vs. 147/150 (98%) with TR-MRA (p = 0.010). Both SNR and CNR were higher with TR-MRA vs. CE-MRA (277.9 ± 48.9 vs. 106.8 ± 41, p = 0.002 and 100.3 ± 41.7 vs. 70.7 ± 48.0, p = 0.002, respectively). Inter-reader variance of individual PV measurements for each of the MR techniques ranged between 0.62 and 1.47 mm and the ICC for vein measurements was higher with TR-MRA (range: 0.62–0.81) compared to CE-MRA (range: 0.47–0.64). TR-MRA, modified to maximize spatial resolution, offers an alternative method for performing high quality MRA examinations in patients with AF. TR-MRA offers greater overall image quality, PV visualization, and similarly reproducible PV measurements compared to traditional CE-MRA, without the challenges of proper bolus timing.
Literature
1.
go back to reference Haïssaguerre M, Jaïs P, Shah DC, Takahashi A, Hocini M, Quiniou G et al (1998) Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 339:659–666CrossRefPubMed Haïssaguerre M, Jaïs P, Shah DC, Takahashi A, Hocini M, Quiniou G et al (1998) Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 339:659–666CrossRefPubMed
2.
go back to reference Chugh SS, Havmoeller R, Narayanan K, Singh D, Rienstra M, Benjamin EJ et al (2014) Worldwide epidemiology of atrial fibrillation: a Global Burden of Disease 2010 Study. Circulation 129:837–847CrossRefPubMed Chugh SS, Havmoeller R, Narayanan K, Singh D, Rienstra M, Benjamin EJ et al (2014) Worldwide epidemiology of atrial fibrillation: a Global Burden of Disease 2010 Study. Circulation 129:837–847CrossRefPubMed
3.
go back to reference Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen S-A et al (2012) 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace 14:528–606CrossRefPubMed Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen S-A et al (2012) 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace 14:528–606CrossRefPubMed
4.
go back to reference Dewire J, Calkins H (2013) Update on atrial fibrillation catheter ablation technologies and techniques. Nat Rev Cardiol 10:599–612CrossRefPubMed Dewire J, Calkins H (2013) Update on atrial fibrillation catheter ablation technologies and techniques. Nat Rev Cardiol 10:599–612CrossRefPubMed
5.
go back to reference Maksimović R, Dill T, Ristić AD, Seferović PM (2006) Imaging in percutaneous ablation for atrial fibrillation. Eur Radiol 16:2491–2504CrossRefPubMed Maksimović R, Dill T, Ristić AD, Seferović PM (2006) Imaging in percutaneous ablation for atrial fibrillation. Eur Radiol 16:2491–2504CrossRefPubMed
6.
go back to reference Ghaye B, Szapiro D, Dacher J-N, Rodriguez L-M, Timmermans C, Devillers D et al. (2003) Percutaneous ablation for atrial fibrillation: the role of cross-sectional imaging. Radiographics 23(Spec No suppl_1):S19-33-50 Ghaye B, Szapiro D, Dacher J-N, Rodriguez L-M, Timmermans C, Devillers D et al. (2003) Percutaneous ablation for atrial fibrillation: the role of cross-sectional imaging. Radiographics 23(Spec No suppl_1):S19-33-50
7.
8.
go back to reference Song T, Laine AF, Chen Q, Rusinek H, Bokacheva L, Lim RP et al (2009) Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography. Magn Reson Med 61:1242–1248CrossRefPubMedPubMedCentral Song T, Laine AF, Chen Q, Rusinek H, Bokacheva L, Lim RP et al (2009) Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography. Magn Reson Med 61:1242–1248CrossRefPubMedPubMedCentral
9.
go back to reference Vogt FM, Theysohn JM, Michna D, Hunold P, Neudorf U, Kinner S et al (2013) Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA. Eur Radiol 23:2392–2404CrossRefPubMed Vogt FM, Theysohn JM, Michna D, Hunold P, Neudorf U, Kinner S et al (2013) Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA. Eur Radiol 23:2392–2404CrossRefPubMed
10.
go back to reference Schonberger M, Usman A, Galizia M, Popescu A, Collins J, Carr JC (2013) Time-resolved MR venography of the pulmonary veins precatheter-based ablation for atrial fibrillation. J Magn Reson Imaging 137:127–137CrossRef Schonberger M, Usman A, Galizia M, Popescu A, Collins J, Carr JC (2013) Time-resolved MR venography of the pulmonary veins precatheter-based ablation for atrial fibrillation. J Magn Reson Imaging 137:127–137CrossRef
11.
go back to reference Korosec FR, Frayne R, Grist TM, Mistretta CA (1996) Time-resolved contrast-enhanced 3D MR angiography. Magn Reson Med 36:345–351CrossRefPubMed Korosec FR, Frayne R, Grist TM, Mistretta CA (1996) Time-resolved contrast-enhanced 3D MR angiography. Magn Reson Med 36:345–351CrossRefPubMed
12.
go back to reference Pinto C, Hickey R, Carroll TJ, Sato K, Dill K, Omary RA et al (2006) Time-resolved MR angiography with generalized autocalibrating partially parallel acquisition and time-resolved echo-sharing angiographic technique for hemodialysis arteriovenous fistulas and grafts. J Vasc Interv Radiol 17:1003–1009CrossRefPubMed Pinto C, Hickey R, Carroll TJ, Sato K, Dill K, Omary RA et al (2006) Time-resolved MR angiography with generalized autocalibrating partially parallel acquisition and time-resolved echo-sharing angiographic technique for hemodialysis arteriovenous fistulas and grafts. J Vasc Interv Radiol 17:1003–1009CrossRefPubMed
13.
go back to reference Lim RP, Shapiro M, Wang EY, Law M, Babb JS, Rueff LE et al (2008) 3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA. Am J Neuroradiol 29:1847–1854CrossRefPubMed Lim RP, Shapiro M, Wang EY, Law M, Babb JS, Rueff LE et al (2008) 3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA. Am J Neuroradiol 29:1847–1854CrossRefPubMed
Metadata
Title
Validation of contrast-enhanced time-resolved magnetic resonance angiography in pre-ablation planning in patients with atrial fibrillation: comparison with traditional technique
Authors
Tarek Zghaib
Adeel Shahid
Chiara Pozzessere
Kristin K. Porter
Linda C. Chu
John Eng
Hugh Calkins
Ihab R. Kamel
Saman Nazarian
Stefan L. Zimmerman
Publication date
01-09-2018
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 9/2018
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-1355-8

Other articles of this Issue 9/2018

The International Journal of Cardiovascular Imaging 9/2018 Go to the issue