Abstract

Purpose

Hip resurfacing arthroplasty (HRA) is a technically demanding operation, requiring both accuracy and precision in placement of the acetabular and femoral components. Malalignment of the component can lead to notching and possible femoral neck fractures. We used specific templates created using a rapid prototyping machine based on the patients’ anatomy, to aid in accurate intraoperative pin placement.

Methods

A 3D model of the hip was reconstructed using spiral computed tomography (CT) data by Amira 3.1 software in 16 patients in whom HRA was planned for hip osteoarthritis (OA). All of the patients in the study had normal contralateral hips. The rotational centre of femoral head on the normal side was superimposed using Imageware12.0 software to determine the centre of the femoral head on the contralateral side. The data was then used to produce patient-specific templates using a rapid prototyping technique. These templates were designed according to the anatomical features of femoral head surface, the rotation centre and the planned prosthesis shaft angle. The orientation of the prosthesis was determined by matching the model to the femoral head surface during the operation. In addition, a control group of 18 patients with OA was operated upon by the conventional method.

Results

The mean prosthesis stem shaft angle (SSA), as determined from postoperative imaging, was 138.68 ± 8.85° for the locating template group, and (118.9 ± 12.8) for the conventional group.

Conclusions

The locating template designed and constructed preoperatively can provide precise and dependable location for hip resurfacing femoral components during arthroplasty and ensure the valgus stem placement necessary for optimal outcomes.
Literature
1.
go back to reference Ball ST, Le Duff MJ, Amstutz HC (2007) Early results of conversion of a failed femoral component in hip resurfacing arthroplasty. J Bone Joint Surg Am 89(4):735–741PubMedCrossRef Ball ST, Le Duff MJ, Amstutz HC (2007) Early results of conversion of a failed femoral component in hip resurfacing arthroplasty. J Bone Joint Surg Am 89(4):735–741PubMedCrossRef
2.
go back to reference Kishida Y, Sugano N, Nishii T, Miki H, Yamaguchi K, Yoshikawa H (2004) Preservation of the bone mineral density of the femur after surface replacement of the hip. J Bone Joint Surg Br 86(2):185–189PubMedCrossRef Kishida Y, Sugano N, Nishii T, Miki H, Yamaguchi K, Yoshikawa H (2004) Preservation of the bone mineral density of the femur after surface replacement of the hip. J Bone Joint Surg Br 86(2):185–189PubMedCrossRef
3.
go back to reference Long JP, Bartel DL (2006) Surgical variables affect the mechanics of a hip resurfacing system. Clin Orthop Relat Res 453:115–122PubMedCrossRef Long JP, Bartel DL (2006) Surgical variables affect the mechanics of a hip resurfacing system. Clin Orthop Relat Res 453:115–122PubMedCrossRef
4.
go back to reference Shimmin AJ, Back D (2005) Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Joint Surg Br 87(4):463–464PubMedCrossRef Shimmin AJ, Back D (2005) Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Joint Surg Br 87(4):463–464PubMedCrossRef
5.
go back to reference Back DL, Dalziel R, Young D, Shimmin A (2005) Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. J Bone Joint Surg Br 87(3):324–329PubMedCrossRef Back DL, Dalziel R, Young D, Shimmin A (2005) Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. J Bone Joint Surg Br 87(3):324–329PubMedCrossRef
6.
go back to reference Mont MA, Seyler TM, Ulrich SD, Beaule PE, Boyd HS, Grecula MJ, Goldberg VM, Kennedy WR, Marker DR, Schmalzried TP, Sparling EA, Vail TP, Amstutz HC (2007) Effect of changing indications and techniques on total hip resurfacing. Clin Orthop Relat Res 465:63–70PubMed Mont MA, Seyler TM, Ulrich SD, Beaule PE, Boyd HS, Grecula MJ, Goldberg VM, Kennedy WR, Marker DR, Schmalzried TP, Sparling EA, Vail TP, Amstutz HC (2007) Effect of changing indications and techniques on total hip resurfacing. Clin Orthop Relat Res 465:63–70PubMed
7.
go back to reference Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA (2004) Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg Am 86-A(1):28–39PubMed Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA (2004) Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg Am 86-A(1):28–39PubMed
8.
go back to reference Amstutz HC, Campbell PA, Le Duff MJ (2004) Fracture of the neck of the femur after surface arthroplasty of the hip. J Bone Joint Surg Am 86-A(9):1874–1877PubMed Amstutz HC, Campbell PA, Le Duff MJ (2004) Fracture of the neck of the femur after surface arthroplasty of the hip. J Bone Joint Surg Am 86-A(9):1874–1877PubMed
9.
go back to reference Cobb JP, Kannan V, Brust K, Thevendran G (2007) Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res 463:90–97PubMed Cobb JP, Kannan V, Brust K, Thevendran G (2007) Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res 463:90–97PubMed
10.
go back to reference Hart R, Svab P, Filan P (2008) Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study. Arch Orthop Trauma Surg 128(4):429–434PubMedCrossRef Hart R, Svab P, Filan P (2008) Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study. Arch Orthop Trauma Surg 128(4):429–434PubMedCrossRef
11.
go back to reference Hodgson AJ, Inkpen KB, Shekhman M, Anglin C, Tonetti J, Masri BA, Duncan CP, Garbuz DS, Greidanus NV (2005) Computer-assisted femoral head resurfacing. Comput Aided Surg 10(5–6):337–343PubMed Hodgson AJ, Inkpen KB, Shekhman M, Anglin C, Tonetti J, Masri BA, Duncan CP, Garbuz DS, Greidanus NV (2005) Computer-assisted femoral head resurfacing. Comput Aided Surg 10(5–6):337–343PubMed
12.
go back to reference Nishii T, Sugano N, Miki H, Takao M, Koyama T, Yoshikawa H (2007) Five-year results of metal-on-metal resurfacing arthroplasty in Asian patients. J Arthroplasty 22(2):176–183PubMedCrossRef Nishii T, Sugano N, Miki H, Takao M, Koyama T, Yoshikawa H (2007) Five-year results of metal-on-metal resurfacing arthroplasty in Asian patients. J Arthroplasty 22(2):176–183PubMedCrossRef
13.
go back to reference Witzleb WC, Arnold M, Krummenauer F, Knecht A, Ranisch H, Gunther KP (2008) Birmingham hip resurfacing arthroplasty: short-term clinical and radiographic outcome. Eur J Med Res 13(1):39–46PubMed Witzleb WC, Arnold M, Krummenauer F, Knecht A, Ranisch H, Gunther KP (2008) Birmingham hip resurfacing arthroplasty: short-term clinical and radiographic outcome. Eur J Med Res 13(1):39–46PubMed
14.
go back to reference Anglin C, Masri BA, Tonetti J, Hodgson AJ, Greidanus NV (2007) Hip resurfacing femoral neck fracture influenced by valgus placement. Clin Orthop Relat Res 465:71–79PubMed Anglin C, Masri BA, Tonetti J, Hodgson AJ, Greidanus NV (2007) Hip resurfacing femoral neck fracture influenced by valgus placement. Clin Orthop Relat Res 465:71–79PubMed
15.
go back to reference Ulrich SD, Bonutti PM, Seyler TM, Marker DR, Jones LC, Mont MA (2007) Outcomes-based evaluations supporting computer-assisted surgery and minimally invasive surgery for total hip arthroplasty. Expert Rev Med Devices 4(6):873–883PubMedCrossRef Ulrich SD, Bonutti PM, Seyler TM, Marker DR, Jones LC, Mont MA (2007) Outcomes-based evaluations supporting computer-assisted surgery and minimally invasive surgery for total hip arthroplasty. Expert Rev Med Devices 4(6):873–883PubMedCrossRef
16.
go back to reference Pitto RP, Malak S, Anderson IA (2009) Accuracy of a computer-assisted navigation system in resurfacing hip arthroplasty. Int Orthop 33(2):391–395PubMedCrossRef Pitto RP, Malak S, Anderson IA (2009) Accuracy of a computer-assisted navigation system in resurfacing hip arthroplasty. Int Orthop 33(2):391–395PubMedCrossRef
17.
go back to reference Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80(3):814–820PubMedCrossRef Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80(3):814–820PubMedCrossRef
18.
go back to reference Brown GA, Firoozbakhsh K, DeCoster TA, Reyna JR Jr, Moneim M (2003) Rapid prototyping: the future of trauma surgery? J Bone Joint Surg Am 85-A(Suppl 4):49–55PubMed Brown GA, Firoozbakhsh K, DeCoster TA, Reyna JR Jr, Moneim M (2003) Rapid prototyping: the future of trauma surgery? J Bone Joint Surg Am 85-A(Suppl 4):49–55PubMed
19.
go back to reference Chaware SM, Bagaria V, Kuthe A (2009) Application of the rapid prototyping technique to design a customized temporomandibular joint used to treat temporomandibular ankylosis. Indian J Plast Surg 42(1):85–93PubMedCrossRef Chaware SM, Bagaria V, Kuthe A (2009) Application of the rapid prototyping technique to design a customized temporomandibular joint used to treat temporomandibular ankylosis. Indian J Plast Surg 42(1):85–93PubMedCrossRef
20.
go back to reference Radermacher K, Portheine F, Anton M, Zimolong A, Kaspers G, Rau G, Staudte HW (1998) Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 354:28–38PubMedCrossRef Radermacher K, Portheine F, Anton M, Zimolong A, Kaspers G, Rau G, Staudte HW (1998) Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 354:28–38PubMedCrossRef
21.
go back to reference Belei P, Skwara A, De La Fuente M, Schkommodau E, Fuchs S, Wirtz DC, Kamper C, Radermacher K (2007) Fluoroscopic navigation system for hip surface replacement. Comput Aided Surg 12(3):160–167PubMed Belei P, Skwara A, De La Fuente M, Schkommodau E, Fuchs S, Wirtz DC, Kamper C, Radermacher K (2007) Fluoroscopic navigation system for hip surface replacement. Comput Aided Surg 12(3):160–167PubMed
22.
go back to reference Hodgson A, Helmy N, Masri BA, Greidanus NV, Inkpen KB, Duncan CP, Garbuz DS, Anglin C (2007) Comparative repeatability of guide-pin axis positioning in computer-assisted and manual femoral head resurfacing arthroplasty. Proc Inst Mech Eng H 221(7):713–724PubMedCrossRef Hodgson A, Helmy N, Masri BA, Greidanus NV, Inkpen KB, Duncan CP, Garbuz DS, Anglin C (2007) Comparative repeatability of guide-pin axis positioning in computer-assisted and manual femoral head resurfacing arthroplasty. Proc Inst Mech Eng H 221(7):713–724PubMedCrossRef
23.
go back to reference Schnurr C, Michael JW, Eysel P, Konig DP (2009) Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy. Int Orthop 33(2):365–372PubMedCrossRef Schnurr C, Michael JW, Eysel P, Konig DP (2009) Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy. Int Orthop 33(2):365–372PubMedCrossRef
24.
go back to reference Marker DR, Seyler TM, Jinnah RH, Delanois RE, Ulrich SD, Mont MA (2007) Femoral neck fractures after metal-on-metal total hip resurfacing: a prospective cohort study. J Arthroplasty 22(7 Suppl 3):66–71PubMedCrossRef Marker DR, Seyler TM, Jinnah RH, Delanois RE, Ulrich SD, Mont MA (2007) Femoral neck fractures after metal-on-metal total hip resurfacing: a prospective cohort study. J Arthroplasty 22(7 Suppl 3):66–71PubMedCrossRef
Metadata
Title
Use of patient-specific templates in hip resurfacing arthroplasty: experience from sixteen cases
Authors
Hao Du
Xiao-xiao Tian
Tong-sen Li
Jin-sheng Yang
Ke-han Li
Guo-xian Pei
Le Xie
Publication date
01-05-2013
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 5/2013
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-1842-4

Other articles of this Issue 5/2013

International Orthopaedics 5/2013 Go to the issue