Published in: Comparative Clinical Pathology 1/2016

01-01-2016 | Original Article

Use of a point-of-care portable blood analyzer for evaluation of blood gas analytes and select physiologic parameters in the American flamingo (Phoenicopterus ruber)

Authors: S. Gardhouse, D. Eshar

Published in: Comparative Clinical Pathology | Issue 1/2016

Login to get access

Abstract

This study was conducted in order to evaluate blood gas analytes using a portable clinical analyzer in captive American flamingos (Phoenicopterus ruber). Seventeen healthy flamingos were evaluated as part of an overall clinical health assessment. Each bird underwent a complete physical examination, complete blood count, and serum biochemistry testing. Blood samples were collected from the medial metatarsal vein and using the VetScan i-STAT® analyzer, tested for the following parameters: hydrogen ion concentration, oxygen tension, carbon dioxide tension, sodium, potassium, ionized calcium, hematocrit, and various calculated parameters. The different parameters of venous blood gas were described using the mean, median, the interquartile range, P2.5 and P97.5, and minimum and maximum values. A comparison between sexes revealed no significant difference (p > 0.05) in any of the observed values. The test provided rapid results and was easy to use, making it useful for point-of-care use in zoological settings, or hospitalized critical avian patients. Knowledge of baseline parameters can promote better physiological understanding and improve clinical management of this avian species.
Literature
go back to reference AbbottPoint of Care (2011) Procedure manual for the i-STAT System. Princeton, NJ AbbottPoint of Care (2011) Procedure manual for the i-STAT System. Princeton, NJ
go back to reference Ardiaca M, Bonvehi C, Montesinos A (2013) Point-of-care blood gas and electrolyte analysis in rabbits. Vet Clin North Am Exot Anim Pract 16:175–195CrossRefPubMed Ardiaca M, Bonvehi C, Montesinos A (2013) Point-of-care blood gas and electrolyte analysis in rabbits. Vet Clin North Am Exot Anim Pract 16:175–195CrossRefPubMed
go back to reference Bateman SW (2008) Making sense of blood gas results. Vet Clin Small Anim 38:543–557CrossRef Bateman SW (2008) Making sense of blood gas results. Vet Clin Small Anim 38:543–557CrossRef
go back to reference Bernstein MH, Samaniego FC (1981) Ventilation and acid–base status during thermal panting in pigeons (Columba livia). Physiol Zool 54:308–315CrossRef Bernstein MH, Samaniego FC (1981) Ventilation and acid–base status during thermal panting in pigeons (Columba livia). Physiol Zool 54:308–315CrossRef
go back to reference Erickson KA, Wilding P (1993) Evaluation of a novel point-of-care system, the i-STAT® portable clinical analyzer. Clin Chem 39:283–287PubMed Erickson KA, Wilding P (1993) Evaluation of a novel point-of-care system, the i-STAT® portable clinical analyzer. Clin Chem 39:283–287PubMed
go back to reference Harms CA, Harms RV (2012) Venous blood gas and lactate values of mourning doves (Zenaida macroura), boat-tailed grackles (Quiscalus major), and house sparrows (Passer domesticus) after capture by mist net, banding, and venipuncture. J Zoo Wildl Med 43:77–78CrossRefPubMed Harms CA, Harms RV (2012) Venous blood gas and lactate values of mourning doves (Zenaida macroura), boat-tailed grackles (Quiscalus major), and house sparrows (Passer domesticus) after capture by mist net, banding, and venipuncture. J Zoo Wildl Med 43:77–78CrossRefPubMed
go back to reference Martin MP, Wineland M, Barnes HJ (2010) Selected blood chemistry and gas reference ranges for broiler breeders using the i-STAT® Handheld Clinical Analyzer. Avian Dis 54:1016–1020CrossRefPubMed Martin MP, Wineland M, Barnes HJ (2010) Selected blood chemistry and gas reference ranges for broiler breeders using the i-STAT® Handheld Clinical Analyzer. Avian Dis 54:1016–1020CrossRefPubMed
go back to reference Martin MP, Wineland M, Barnes HJ (2011) Selected Blood chemistry values in mobility impaired broiler breeder hens with suspected calcium tetany using the i-STAT® Handheld Clinical Analyzer. Avian Dis 55:340–345CrossRefPubMed Martin MP, Wineland M, Barnes HJ (2011) Selected Blood chemistry values in mobility impaired broiler breeder hens with suspected calcium tetany using the i-STAT® Handheld Clinical Analyzer. Avian Dis 55:340–345CrossRefPubMed
go back to reference Merritt EL, Curtis LF, Ramasay ED (1996) Hematologic and serum biochemical values in captive American flamingos. J Avian Med Surg 10:163–167 Merritt EL, Curtis LF, Ramasay ED (1996) Hematologic and serum biochemical values in captive American flamingos. J Avian Med Surg 10:163–167
go back to reference Naples LM, Mylniczenko ND, Zachariah TT, Wilborn RE, Young FA (2012) Evaluation of critical care blood analytes assessed with a point-of-care portable blood analyzer in wild and aquarium-housed elasmobranchs and the influence of phlebotomy site on results. J Am Vet Med Assoc 241:117–125CrossRefPubMed Naples LM, Mylniczenko ND, Zachariah TT, Wilborn RE, Young FA (2012) Evaluation of critical care blood analytes assessed with a point-of-care portable blood analyzer in wild and aquarium-housed elasmobranchs and the influence of phlebotomy site on results. J Am Vet Med Assoc 241:117–125CrossRefPubMed
go back to reference Norton TM (2003) Flamingos. In: Fowler ME, Miller RE (eds) Zoo and wild animal medicine. WB Saunders, Philadelphia, pp 129–135 Norton TM (2003) Flamingos. In: Fowler ME, Miller RE (eds) Zoo and wild animal medicine. WB Saunders, Philadelphia, pp 129–135
go back to reference Paula F (2006) Blood gas and electrolyte values for Amazon parrots (Amazona aestival). Braz J Vet Res Anim Sci 26:108–112 Paula F (2006) Blood gas and electrolyte values for Amazon parrots (Amazona aestival). Braz J Vet Res Anim Sci 26:108–112
go back to reference Peiro JR, Borges AS, Goncalves RC, Mendes LC (2010) Evaluation of a portable clinical analyzer for the determination of blood gas partial pressures, electrolyte concentrations, and hematocrit in venous blood samples collected from cattle, horses, and sheep. Am J Vet Res 71:515–521CrossRefPubMed Peiro JR, Borges AS, Goncalves RC, Mendes LC (2010) Evaluation of a portable clinical analyzer for the determination of blood gas partial pressures, electrolyte concentrations, and hematocrit in venous blood samples collected from cattle, horses, and sheep. Am J Vet Res 71:515–521CrossRefPubMed
go back to reference Rettenmund CL, Heatley JJ, Russell KE (2014) Comparison of two analysers to determine selected venous blood analytes of Quaker parrots (Myiopsitta monachus). J Zoo Wildl Med 45:256–22CrossRefPubMed Rettenmund CL, Heatley JJ, Russell KE (2014) Comparison of two analysers to determine selected venous blood analytes of Quaker parrots (Myiopsitta monachus). J Zoo Wildl Med 45:256–22CrossRefPubMed
go back to reference Rumke CR, Bezemer PD (1972) Methods for the establishment of reference values II. New methods Ned Tijdschr Geneeskd 116:1559–1568 Rumke CR, Bezemer PD (1972) Methods for the establishment of reference values II. New methods Ned Tijdschr Geneeskd 116:1559–1568
go back to reference Sediame S, Zerah-Lancner F, D’Ortho MP, Adnot S, Harf A (1999) Accuracy of the i-STAT® bedside blood gas analyzer. Eur Respir J 14:214–217CrossRefPubMed Sediame S, Zerah-Lancner F, D’Ortho MP, Adnot S, Harf A (1999) Accuracy of the i-STAT® bedside blood gas analyzer. Eur Respir J 14:214–217CrossRefPubMed
go back to reference Silverman SC, Birks EK (2002) Evaluation of the i-STAT® hand-held chemical analyser during treadmill and endurance exercise. Equine Vet J Suppl 34:551–554CrossRef Silverman SC, Birks EK (2002) Evaluation of the i-STAT® hand-held chemical analyser during treadmill and endurance exercise. Equine Vet J Suppl 34:551–554CrossRef
go back to reference Steinmetz HW (2007) Evaluation of the i-STAT® Portable Clinical Analyzer in chickens (Gallus Gallus). J Vet Diagn Invest 19:382–388CrossRefPubMed Steinmetz HW (2007) Evaluation of the i-STAT® Portable Clinical Analyzer in chickens (Gallus Gallus). J Vet Diagn Invest 19:382–388CrossRefPubMed
go back to reference Stoot LJ, Cairns NA, Cull F, Taylor JJ, Jeffrey JD, Morin F et al (2014) Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review. Conserv Physiol 2:1–21CrossRef Stoot LJ, Cairns NA, Cull F, Taylor JJ, Jeffrey JD, Morin F et al (2014) Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review. Conserv Physiol 2:1–21CrossRef
go back to reference Verwaered P, Malet C, Lagente M, de la Farge T, Braum JP (2002) The accuracy of the i-STAT portable analyser for measuring blood gases and pH in whole-blood samples from dogs. Res Vet Sci 73:71–75CrossRef Verwaered P, Malet C, Lagente M, de la Farge T, Braum JP (2002) The accuracy of the i-STAT portable analyser for measuring blood gases and pH in whole-blood samples from dogs. Res Vet Sci 73:71–75CrossRef
Metadata
Title
Use of a point-of-care portable blood analyzer for evaluation of blood gas analytes and select physiologic parameters in the American flamingo (Phoenicopterus ruber)
Authors
S. Gardhouse
D. Eshar
Publication date
01-01-2016
Publisher
Springer London
Published in
Comparative Clinical Pathology / Issue 1/2016
Print ISSN: 1618-5641
Electronic ISSN: 1618-565X
DOI
https://doi.org/10.1007/s00580-015-2160-6

Other articles of this Issue 1/2016

Comparative Clinical Pathology 1/2016 Go to the issue