Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2009

Open Access 01-12-2009 | Case report

Unique relationship between osteophyte and femoral-tibia component size mismatch in determining polyethylene wear in primary total knee arthroplasty: a case report

Authors: Manjunath Ramappa, Andrew Port

Published in: Journal of Medical Case Reports | Issue 1/2009

Login to get access

Abstract

Introduction

Knee pain is a complex problem that can occur after total knee arthroplasty. One cause of knee pain may be due to a retained osteophyte, but it is not clear if the retained osteophyte is sufficient explanation of the pain, as not all patients with retained osteophytes are symptomatic. In fact, the literature shows that excised osteophytes can also recur over a period of time, without any symptoms. Therefore a retained osteophyte alone is probably not sufficient to cause symptoms.

Case presentation

We present a case of intermittent medial knee pain occurring post-primary total knee arthroplasty, in a patient who underwent several investigations over a period of 5 years. Radiographs showed an osteophyte in the postero-medial femur along with slight tibial component overhang which was normal for that knee implant design. The symptoms eventually settled with excision of only the osteophyte, without altering the tibial component.

Conclusion

A retained osteophyte alone, or tibial component overhang alone, did not seem to cause significant symptoms in our patient whose symptoms completely settled with excision of the osteophyte alone, without changing the tibial component. Therefore, it seems that the combination of retained osteophyte and tibial component overhang (tibia-femoral component size mismatch) are detrimental and therefore best avoided. This report also emphasises the importance of meticulous osteophyte excision and avoiding tibial component overhang during knee arthroplasty.
Appendix
Available only for authorised users
Literature
1.
go back to reference Elson DW, Brenkel IJ: A conservative approach is feasible in unexplained pain after knee replacement. A selected cohort study. J Bone Joint Surg Br. 2007, 89 (8): 1042-1045. 10.1302/0301-620X.89B8.19389.CrossRefPubMed Elson DW, Brenkel IJ: A conservative approach is feasible in unexplained pain after knee replacement. A selected cohort study. J Bone Joint Surg Br. 2007, 89 (8): 1042-1045. 10.1302/0301-620X.89B8.19389.CrossRefPubMed
2.
go back to reference Gonzalez MH, Mekhail AO: The failed total lnee arthroplasty: evaluation and etiology. J Am Acad Orthop Surg. 2004, 12: 436-446.CrossRefPubMed Gonzalez MH, Mekhail AO: The failed total lnee arthroplasty: evaluation and etiology. J Am Acad Orthop Surg. 2004, 12: 436-446.CrossRefPubMed
3.
go back to reference Schmalzried TP, Callaghan JJ: A current concepts review – wear in total hip and knee replacements. J Bone Joint Surg. 1999, 81: 115-136.PubMed Schmalzried TP, Callaghan JJ: A current concepts review – wear in total hip and knee replacements. J Bone Joint Surg. 1999, 81: 115-136.PubMed
4.
go back to reference Van Mourik JBA, Verhaar JAN, Heijboer RP, Van Kampen A: Limited value of arthroscopic evaluation and treatment of painful knee prosthesis of 27 cases. Arthroscopy. 1998, 14: 877-879.CrossRefPubMed Van Mourik JBA, Verhaar JAN, Heijboer RP, Van Kampen A: Limited value of arthroscopic evaluation and treatment of painful knee prosthesis of 27 cases. Arthroscopy. 1998, 14: 877-879.CrossRefPubMed
5.
go back to reference Jones SMG, Pinder IM, Moran CG, Malcolm AJ: Polyethylene wear in uncemented knee replacements. J Bone Joint Surg Br. 1992, 74: 18-22.PubMed Jones SMG, Pinder IM, Moran CG, Malcolm AJ: Polyethylene wear in uncemented knee replacements. J Bone Joint Surg Br. 1992, 74: 18-22.PubMed
6.
go back to reference Saouti R, van Royen BJ, Fortanier CM: An impinging remnant meniscus causing early polyethylene failure in total knee arthroplasty: a case report. J Med Case Reports. 2007, 1: 48-10.1186/1752-1947-1-48.CrossRefPubMedCentral Saouti R, van Royen BJ, Fortanier CM: An impinging remnant meniscus causing early polyethylene failure in total knee arthroplasty: a case report. J Med Case Reports. 2007, 1: 48-10.1186/1752-1947-1-48.CrossRefPubMedCentral
7.
go back to reference Scher DM, Paumier JC, Di Cesare PE: Pseudomeniscus following total knee arthroplasty as a cause of persistent knee pain. J Arthroplasty. 1997, 12 (1): 114-118. 10.1016/S0883-5403(97)90056-5.CrossRefPubMed Scher DM, Paumier JC, Di Cesare PE: Pseudomeniscus following total knee arthroplasty as a cause of persistent knee pain. J Arthroplasty. 1997, 12 (1): 114-118. 10.1016/S0883-5403(97)90056-5.CrossRefPubMed
8.
go back to reference Cameron HU: Tibial component wear in total knee replacement. Clin Orthop Relat Res. 1994, 309: 29-32.PubMed Cameron HU: Tibial component wear in total knee replacement. Clin Orthop Relat Res. 1994, 309: 29-32.PubMed
9.
go back to reference Dennis DA, Channer M: Retained distal femoral osteophyte. An infrequent cause of postoperative pain following total knee arthroplasty. J Arthroplasty. 1992, 7 (2): 193-195. 10.1016/0883-5403(92)90016-J.CrossRefPubMed Dennis DA, Channer M: Retained distal femoral osteophyte. An infrequent cause of postoperative pain following total knee arthroplasty. J Arthroplasty. 1992, 7 (2): 193-195. 10.1016/0883-5403(92)90016-J.CrossRefPubMed
10.
go back to reference Majewski M, Weining G, Friederich NF: Posterior femoral impingement causing polyethylene failure in total knee arthroplasty. J Arthroplasty. 2002, 17 (4): 524-526. 10.1054/arth.2002.32131.CrossRefPubMed Majewski M, Weining G, Friederich NF: Posterior femoral impingement causing polyethylene failure in total knee arthroplasty. J Arthroplasty. 2002, 17 (4): 524-526. 10.1054/arth.2002.32131.CrossRefPubMed
11.
go back to reference Plante-Bordeneuve P, Freeman MAR: Tibial high-density polyethylene wear in conforming tibiofemoral prostheses. J Bone Joint Surg Br. 1993, 75 (4): 630-636.PubMed Plante-Bordeneuve P, Freeman MAR: Tibial high-density polyethylene wear in conforming tibiofemoral prostheses. J Bone Joint Surg Br. 1993, 75 (4): 630-636.PubMed
12.
go back to reference Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG: Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994, 299: 31-43.PubMed Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG: Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994, 299: 31-43.PubMed
13.
go back to reference Schai PA, Thornhill TS, Scott RD: Total knee arthroplasty with the PFC system. Results at a minimum of ten years and survivorship analysis. J Bone Joint Surg Br. 1999, 81 (3): 558-559. Schai PA, Thornhill TS, Scott RD: Total knee arthroplasty with the PFC system. Results at a minimum of ten years and survivorship analysis. J Bone Joint Surg Br. 1999, 81 (3): 558-559.
14.
go back to reference Bosco J, Benjamin J, Wallace D: Quantitative and qualitative analysis of polyethylene wear particles in synovial fluid of patients with total knee arthroplasty. A preliminary report. Clin Orthop Relat Res. 1994, 309: 11-19.PubMed Bosco J, Benjamin J, Wallace D: Quantitative and qualitative analysis of polyethylene wear particles in synovial fluid of patients with total knee arthroplasty. A preliminary report. Clin Orthop Relat Res. 1994, 309: 11-19.PubMed
Metadata
Title
Unique relationship between osteophyte and femoral-tibia component size mismatch in determining polyethylene wear in primary total knee arthroplasty: a case report
Authors
Manjunath Ramappa
Andrew Port
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2009
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-3-59

Other articles of this Issue 1/2009

Journal of Medical Case Reports 1/2009 Go to the issue