Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2009

Open Access 01-12-2009 | Case report

An unusual case of ST-segment elevation myocardial infarction following a late bare-metal stent fracture in a native coronary artery: a case report

Authors: Giovanni Minardi, Paolo G Pino, Marco Stefano Nazzaro, Herribert Pavaci, Martina Sordi, Cesare Greco, Carlo Gaudio

Published in: Journal of Medical Case Reports | Issue 1/2009

Login to get access

Abstract

Introduction

A bare-metal stent fracture as a cause of acute coronary thrombosis and consequently of acute coronary syndrome is a rare clinical event that, to the best of our knowledge, has previously not been reported. A stent fracture is a rare complication arising from percutaneous coronary intervention.

Case presentation

We present, to the best of our knowledge, the first documented case of ST-segment elevation myocardial infarction in a patient following a late bare-metal stent fracture and thrombosis in a native coronary artery. The patient, a 51-year-old Caucasian man, was treated successfully with primary percutaneous coronary intervention and a new stent implantation.

Conclusion

A coronary stent fracture is a rare complication that has been described in venous bypass grafts deploying either a drug-eluting stent or a bare-metal stent. Stent fractures rarely occur in coronary arteries. In light of the non-specific presentation of stent fracture, it is also an easily missed complication. Patients may present with a non-specific symptom of angina. The angina could either be stable or unstable as a result of restenosis or in-stent thrombosis, or both. Our case demonstrates the most severe consequences of a bare-metal stent fracture (sudden coronary thrombosis and subsequent myocardial infarction) in a native coronary artery. It was diagnosed angiographically and treated early and effectively.
Appendix
Available only for authorised users
Literature
1.
go back to reference Lee SH, Park JS, Shin DG, Kim YJ, Hong GR, Kim W, Shim BS: Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol. 2007, 100 (4): 627-630. 10.1016/j.amjcard.2007.03.073.CrossRefPubMed Lee SH, Park JS, Shin DG, Kim YJ, Hong GR, Kim W, Shim BS: Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol. 2007, 100 (4): 627-630. 10.1016/j.amjcard.2007.03.073.CrossRefPubMed
2.
go back to reference Chowdhury PS, Ramos RG: Images in clinical medicine: coronary-stent fracture. N Engl J Med. 2002, 347: 581-10.1056/NEJMicm020259.CrossRefPubMed Chowdhury PS, Ramos RG: Images in clinical medicine: coronary-stent fracture. N Engl J Med. 2002, 347: 581-10.1056/NEJMicm020259.CrossRefPubMed
3.
go back to reference Kwon SU, Doh JH, Namgung J, Lee SY: Images in cardiology: stent strut fracture-induced restenosis in the right coronary artery: detection by MDCT. Heart. 2008, 94: 221-10.1136/hrt.2006.108175.CrossRefPubMed Kwon SU, Doh JH, Namgung J, Lee SY: Images in cardiology: stent strut fracture-induced restenosis in the right coronary artery: detection by MDCT. Heart. 2008, 94: 221-10.1136/hrt.2006.108175.CrossRefPubMed
4.
go back to reference Sacks BA, Miller A, Gottlieb M: Fracture of an iliac artery Palmaz stent. Vasc Interv Radiol. 1996, 7 (1): 53-55. 10.1016/S1051-0443(96)70733-9.CrossRef Sacks BA, Miller A, Gottlieb M: Fracture of an iliac artery Palmaz stent. Vasc Interv Radiol. 1996, 7 (1): 53-55. 10.1016/S1051-0443(96)70733-9.CrossRef
5.
go back to reference Phipp LH, Scott DJ, Kessel D, Robertson I: Subclavian stents and stent-grafts: cause for concern?. J Endovasc Surg. 1999, 6 (3): 223-226. 10.1583/1074-6218(1999)006<0223:SSASCF>2.0.CO;2.CrossRefPubMed Phipp LH, Scott DJ, Kessel D, Robertson I: Subclavian stents and stent-grafts: cause for concern?. J Endovasc Surg. 1999, 6 (3): 223-226. 10.1583/1074-6218(1999)006<0223:SSASCF>2.0.CO;2.CrossRefPubMed
6.
go back to reference Hamilos MI, Papafaklis MI, Ligthart JM, Serruys PW, Sianos G: Stent fracture and restenosis of a paclitaxel-eluting stent. Hellenic J Cardiol. 2005, 46: 439-442.PubMed Hamilos MI, Papafaklis MI, Ligthart JM, Serruys PW, Sianos G: Stent fracture and restenosis of a paclitaxel-eluting stent. Hellenic J Cardiol. 2005, 46: 439-442.PubMed
7.
go back to reference Sianos G, Hofma S, Ligthart JM, Saia F, Hoye A, Lemos PA, Serruys PW: Stent fracture and restenosis in the drug-eluting stent era. Catheter Cardiovasc Interv. 2004, 61: 111-116. 10.1002/ccd.10709.CrossRefPubMed Sianos G, Hofma S, Ligthart JM, Saia F, Hoye A, Lemos PA, Serruys PW: Stent fracture and restenosis in the drug-eluting stent era. Catheter Cardiovasc Interv. 2004, 61: 111-116. 10.1002/ccd.10709.CrossRefPubMed
8.
go back to reference Min PK, Yoon YW, Moon Kwon H: Delayed strut fracture of sirolimus-eluting stent: a significant problem or an occasional observation?. Int J Cardiol. 2006, 106: 404-406. 10.1016/j.ijcard.2004.12.087.CrossRefPubMed Min PK, Yoon YW, Moon Kwon H: Delayed strut fracture of sirolimus-eluting stent: a significant problem or an occasional observation?. Int J Cardiol. 2006, 106: 404-406. 10.1016/j.ijcard.2004.12.087.CrossRefPubMed
9.
go back to reference Jin X, Zhang S, Xie H, Wang C, Fan Z, Zeng Y, Shen Z, Fang Q: Strut fracture of DES: an increasing problem?. Int J Cardiol. 2007, 118: 54-56. 10.1016/j.ijcard.2006.12.064.CrossRef Jin X, Zhang S, Xie H, Wang C, Fan Z, Zeng Y, Shen Z, Fang Q: Strut fracture of DES: an increasing problem?. Int J Cardiol. 2007, 118: 54-56. 10.1016/j.ijcard.2006.12.064.CrossRef
10.
go back to reference Mitsutake R, Miura SI, Nishikawa H, Saku K: Usefulness of the evaluation of stent fracture by 64-multi-detector row computer tomography. J of Cardiol. 2008, 52: 135-138. 10.1016/j.jjcc.2007.11.003.CrossRef Mitsutake R, Miura SI, Nishikawa H, Saku K: Usefulness of the evaluation of stent fracture by 64-multi-detector row computer tomography. J of Cardiol. 2008, 52: 135-138. 10.1016/j.jjcc.2007.11.003.CrossRef
Metadata
Title
An unusual case of ST-segment elevation myocardial infarction following a late bare-metal stent fracture in a native coronary artery: a case report
Authors
Giovanni Minardi
Paolo G Pino
Marco Stefano Nazzaro
Herribert Pavaci
Martina Sordi
Cesare Greco
Carlo Gaudio
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2009
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-3-9296

Other articles of this Issue 1/2009

Journal of Medical Case Reports 1/2009 Go to the issue