Skip to main content
Top
Published in: European Radiology 10/2022

17-05-2022 | Ultrasound | Musculoskeletal

Incidence of infectious complications following ultrasound-guided percutaneous musculoskeletal interventions with the use of an uncovered transducer footprint

Authors: Natalia Gorelik, Yousef Darwish, William R. Walter, Christopher J. Burke, Dost Sarpel, Jaron Chong, Ronald S. Adler

Published in: European Radiology | Issue 10/2022

Login to get access

Abstract

Objectives

To determine the incidence of infectious complications following ultrasound-guided musculoskeletal interventions performed with a disinfected uncovered ultrasound transducer footprint.

Methods

Electronic medical records of all patients who underwent an ultrasound-guided musculoskeletal procedure (including injection, calcific lavage, or ganglion cyst aspiration) performed by any of the 14 interventional musculoskeletal radiologists at our institution between January 2013 and December 2018 were retrospectively reviewed to identify procedure site infections. Biopsies and joint aspirations were excluded. The procedures were performed using a disinfected uncovered transducer footprint. First, an automated chart review identified cases with (1) positive answers to the nurse’s post-procedure call, (2) an International Classification of Diseases (ICD) diagnostic code related to a musculoskeletal infection, or (3) an antibiotic prescription within 30 days post-procedure. Then, these cases were manually reviewed for evidence of procedure site infection.

Results

In total, 6511 procedures were included. The automated chart review identified 3 procedures (2 patients) in which post-procedural fever was reported during the nurse’s post-procedure call, 33 procedures (28 patients) with an ICD code for a musculoskeletal infection, and 220 procedures (216 patients) with an antibiotic prescription within 30 post-procedural days. The manual chart review of these patients revealed no cases of confirmed infection and 1 case (0.015%) of possible site infection.

Conclusions

The incidence of infectious complications after an ultrasound-guided musculoskeletal procedure performed with an uncovered transducer footprint is extremely low. This information allows radiologists to counsel their patients more precisely when obtaining informed consent.

Key Points

• Infectious complications after ultrasound-guided musculoskeletal procedures performed with a disinfected uncovered transducer footprint are extremely rare.
Literature
1.
go back to reference Carrico RM, Furmanek S, English C (2018) Ultrasound probe use and reprocessing: Results from a national survey among U.S. infection preventionists. Am J Infect Control 46:913–920CrossRef Carrico RM, Furmanek S, English C (2018) Ultrasound probe use and reprocessing: Results from a national survey among U.S. infection preventionists. Am J Infect Control 46:913–920CrossRef
2.
go back to reference Reisenauer C, Fazzio RT, Hesley G (2017) JOURNAL CLUB: Ultrasound-guided breast interventions: low incidence of infectious complications with use of an uncovered probe. AJR Am J Roentgenol 208:1147–1153CrossRef Reisenauer C, Fazzio RT, Hesley G (2017) JOURNAL CLUB: Ultrasound-guided breast interventions: low incidence of infectious complications with use of an uncovered probe. AJR Am J Roentgenol 208:1147–1153CrossRef
3.
go back to reference Marhofer P, Schebesta K, Marhofer D (2016) Hygiene aspects in ultrasound-guided regional anesthesia. Anaesthesist 65:492–498CrossRef Marhofer P, Schebesta K, Marhofer D (2016) Hygiene aspects in ultrasound-guided regional anesthesia. Anaesthesist 65:492–498CrossRef
4.
go back to reference Draghi F, Robotti G, Jacob D, Bianchi S (2010) Interventional musculoskeletal ultrasonography: precautions and contraindications. J Ultrasound 13:126–133CrossRef Draghi F, Robotti G, Jacob D, Bianchi S (2010) Interventional musculoskeletal ultrasonography: precautions and contraindications. J Ultrasound 13:126–133CrossRef
5.
go back to reference Lento PH, Strakowski JA (2010) The use of ultrasound in guiding musculoskeletal interventional procedures. Phys Med Rehabil Clin N Am 21:559–583CrossRef Lento PH, Strakowski JA (2010) The use of ultrasound in guiding musculoskeletal interventional procedures. Phys Med Rehabil Clin N Am 21:559–583CrossRef
6.
go back to reference Sibbitt WL, Peisajovich A, Michael AA et al (2009) Does sonographic needle guidance affect the clinical outcome of intraarticular injections? J Rheumatol 36:1892–1902CrossRef Sibbitt WL, Peisajovich A, Michael AA et al (2009) Does sonographic needle guidance affect the clinical outcome of intraarticular injections? J Rheumatol 36:1892–1902CrossRef
7.
go back to reference Cipolletta E, Filippucci E, Incorvaia A et al (2021) Ultrasound-Guided Procedures in Rheumatology Daily Practice: Feasibility, Accuracy, and Safety Issues. J Clin Rheumatol 27:226–231CrossRef Cipolletta E, Filippucci E, Incorvaia A et al (2021) Ultrasound-Guided Procedures in Rheumatology Daily Practice: Feasibility, Accuracy, and Safety Issues. J Clin Rheumatol 27:226–231CrossRef
8.
go back to reference Micu MC, Vlad VM, Bolboacă SD et al (2014) Musculoskeletal ultrasound guided manoeuvres - a security profile. Med Ultrason 16:214–221PubMed Micu MC, Vlad VM, Bolboacă SD et al (2014) Musculoskeletal ultrasound guided manoeuvres - a security profile. Med Ultrason 16:214–221PubMed
9.
go back to reference Gross RM (2015) CORR Insights®: does the use of ultrasound affect contamination of musculoskeletal injections sites? Clin Orthop Relat Res 473:358–360CrossRef Gross RM (2015) CORR Insights®: does the use of ultrasound affect contamination of musculoskeletal injections sites? Clin Orthop Relat Res 473:358–360CrossRef
10.
go back to reference Hynes JP, Fhlatharta MN, Ryan JW, MacMahon PJ, Eustace SJ, Kavanagh EC (2021) Complications in image-guided musculoskeletal injections. Skelet Radiol 50:343–349CrossRef Hynes JP, Fhlatharta MN, Ryan JW, MacMahon PJ, Eustace SJ, Kavanagh EC (2021) Complications in image-guided musculoskeletal injections. Skelet Radiol 50:343–349CrossRef
11.
go back to reference Bansal A, Goyal A, Gamanagatti S, Srivastava DN, Manhas V (2021) Current updates in image-guided musculoskeletal interventions. J Clin Orthop Trauma 22:101601CrossRef Bansal A, Goyal A, Gamanagatti S, Srivastava DN, Manhas V (2021) Current updates in image-guided musculoskeletal interventions. J Clin Orthop Trauma 22:101601CrossRef
12.
go back to reference Rand E, Welbel R, Visco CJ (2016) Fundamental considerations for ultrasound-guided musculoskeletal interventions. Phys Med Rehabil Clin N Am 27:539–553CrossRef Rand E, Welbel R, Visco CJ (2016) Fundamental considerations for ultrasound-guided musculoskeletal interventions. Phys Med Rehabil Clin N Am 27:539–553CrossRef
13.
go back to reference Daugherty SF, Blebea J (2021) The need for participation in the development and critical review of recommendations for infection control policies involving vascular ultrasound. J Vasc Surg Venous Lymphat Disord 9:1025–1030CrossRef Daugherty SF, Blebea J (2021) The need for participation in the development and critical review of recommendations for infection control policies involving vascular ultrasound. J Vasc Surg Venous Lymphat Disord 9:1025–1030CrossRef
14.
go back to reference Sherman T, Ferguson J, Davis W, Russo M, Argintar E (2015) Does the use of ultrasound affect contamination of musculoskeletal injections sites? Clin Orthop Relat Res 473:351–357CrossRef Sherman T, Ferguson J, Davis W, Russo M, Argintar E (2015) Does the use of ultrasound affect contamination of musculoskeletal injections sites? Clin Orthop Relat Res 473:351–357CrossRef
15.
go back to reference Heil J, Hug S, Martiny H et al (2018) Standards of hygiene for ultrasound-guided core cut biopsies of the breast. Ultraschall Med 39:636–642CrossRef Heil J, Hug S, Martiny H et al (2018) Standards of hygiene for ultrasound-guided core cut biopsies of the breast. Ultraschall Med 39:636–642CrossRef
16.
go back to reference Nyhsen CM, Humphreys H, Nicolau C, Mostbeck G, Claudon M (2016) Infection prevention and ultrasound probe decontamination practices in Europe: a survey of the European Society of Radiology. Insights Imaging 7:841–847CrossRef Nyhsen CM, Humphreys H, Nicolau C, Mostbeck G, Claudon M (2016) Infection prevention and ultrasound probe decontamination practices in Europe: a survey of the European Society of Radiology. Insights Imaging 7:841–847CrossRef
17.
go back to reference Davidson J, Jayaraman S (2011) Guided interventions in musculoskeletal ultrasound: what's the evidence? Clin Radiol 66:140–152CrossRef Davidson J, Jayaraman S (2011) Guided interventions in musculoskeletal ultrasound: what's the evidence? Clin Radiol 66:140–152CrossRef
18.
go back to reference Sherman T, Ferguson J, Davis W, Russo M, Argintar E (2015) Reply to the letter to the editor: does the use of ultrasound affect contamination of musculoskeletal injections sites? Clin Orthop Relat Res 473:391–392CrossRef Sherman T, Ferguson J, Davis W, Russo M, Argintar E (2015) Reply to the letter to the editor: does the use of ultrasound affect contamination of musculoskeletal injections sites? Clin Orthop Relat Res 473:391–392CrossRef
19.
go back to reference Alakkad H, Naeeni A, Chan VW et al (2015) Infection related to ultrasound-guided single-injection peripheral nerve blockade: a decade of experience at toronto Western hospital. Reg Anesth Pain Med 40:82–84CrossRef Alakkad H, Naeeni A, Chan VW et al (2015) Infection related to ultrasound-guided single-injection peripheral nerve blockade: a decade of experience at toronto Western hospital. Reg Anesth Pain Med 40:82–84CrossRef
20.
go back to reference Suresh V, Asish K, Devi PS (2015) Improvised glove barrier for ultrasound probe protection. Anesth Essays Res 9:448–449CrossRef Suresh V, Asish K, Devi PS (2015) Improvised glove barrier for ultrasound probe protection. Anesth Essays Res 9:448–449CrossRef
21.
go back to reference Caturelli E, Giacobbe A, Facciorusso D et al (1996) Free-hand technique with ordinary antisepsis in abdominal US-guided fine-needle punctures: three-year experience. Radiology 199:721–723CrossRef Caturelli E, Giacobbe A, Facciorusso D et al (1996) Free-hand technique with ordinary antisepsis in abdominal US-guided fine-needle punctures: three-year experience. Radiology 199:721–723CrossRef
22.
go back to reference Cervini P, Hesley GK, Thompson RL, Sampathkumar P, Knudsen JM (2010) Incidence of infectious complications after an ultrasound-guided intervention. AJR Am J Roentgenol 195:846–850CrossRef Cervini P, Hesley GK, Thompson RL, Sampathkumar P, Knudsen JM (2010) Incidence of infectious complications after an ultrasound-guided intervention. AJR Am J Roentgenol 195:846–850CrossRef
23.
go back to reference Charalambous CP, Tryfonidis M, Sadiq S, Hirst P, Paul A (2003) Septic arthritis following intra-articular steroid injection of the knee--a survey of current practice regarding antiseptic technique used during intra-articular steroid injection of the knee. Clin Rheumatol 22:386–390CrossRef Charalambous CP, Tryfonidis M, Sadiq S, Hirst P, Paul A (2003) Septic arthritis following intra-articular steroid injection of the knee--a survey of current practice regarding antiseptic technique used during intra-articular steroid injection of the knee. Clin Rheumatol 22:386–390CrossRef
24.
go back to reference Murphy J, McGarry S, Patel A, Davies AM, James SL, Botchu R (2018) A cost-saving measure for ultrasound-guided musculoskeletal injections. J Ultrasound 21:277–278CrossRef Murphy J, McGarry S, Patel A, Davies AM, James SL, Botchu R (2018) A cost-saving measure for ultrasound-guided musculoskeletal injections. J Ultrasound 21:277–278CrossRef
25.
go back to reference Peters N (2020) Different minimum requirements for transducer cleaning and disinfection between the Australian Standard and the ASUM/ACIPC joint guideline. Australas J Ultrasound Med 23:269–270CrossRef Peters N (2020) Different minimum requirements for transducer cleaning and disinfection between the Australian Standard and the ASUM/ACIPC joint guideline. Australas J Ultrasound Med 23:269–270CrossRef
26.
go back to reference (2021) Disinfection of ultrasound transducers used for percutaneous procedures: intersocietal position statement. J Ultrasound Med 40:895-897 (2021) Disinfection of ultrasound transducers used for percutaneous procedures: intersocietal position statement. J Ultrasound Med 40:895-897
27.
go back to reference (2016) AIUM practice parameter for the performance of selected ultrasound-guided procedures. J Ultrasound Med 35:1–40 (2016) AIUM practice parameter for the performance of selected ultrasound-guided procedures. J Ultrasound Med 35:1–40
28.
go back to reference Bick U, Trimboli RM, Athanasiou A et al (2020) Image-guided breast biopsy and localisation: recommendations for information to women and referring physicians by the European Society of Breast Imaging. Insights Imaging 11:12CrossRef Bick U, Trimboli RM, Athanasiou A et al (2020) Image-guided breast biopsy and localisation: recommendations for information to women and referring physicians by the European Society of Breast Imaging. Insights Imaging 11:12CrossRef
Metadata
Title
Incidence of infectious complications following ultrasound-guided percutaneous musculoskeletal interventions with the use of an uncovered transducer footprint
Authors
Natalia Gorelik
Yousef Darwish
William R. Walter
Christopher J. Burke
Dost Sarpel
Jaron Chong
Ronald S. Adler
Publication date
17-05-2022
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 10/2022
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-022-08849-6

Other articles of this Issue 10/2022

European Radiology 10/2022 Go to the issue