Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 5/2014

01-06-2014 | Original Paper

Two-dimensional echocardiography using second harmonic imaging for the diagnosis of intracardiac right-to-left shunt: a meta-analysis of prospective studies

Authors: Mohammad Khalid Mojadidi, Jared S. Winoker, Scott C. Roberts, Pavlos Msaouel, Rubine Gevorgyan, Ronald Zolty

Published in: The International Journal of Cardiovascular Imaging | Issue 5/2014

Login to get access

Abstract

Right-to-left shunting (RLS), usually through a patent foramen ovale (PFO), has been associated with migraine, cryptogenic stroke and hypoxemia. With emerging observational studies and clinical trials on the subject of PFO, there is a need for accurate diagnosis of PFO in patients being considered for transcatheter closure. While transesophageal echo (TEE) bubble study is the current standard reference for diagnosing PFO, transthoracic echo with second harmonic imaging (TTE-HI) may be a preferable screening test for RLS due to its high accuracy and non-invasiveness. The aim of this meta-analysis was to determine the accuracy of TTE-HI compared to TEE as the reference. A systematic review of Medline, Cochrane and Embase was done for all the prospective studies assessing for intracardiac RLS using TTE-HI compared to TEE as the reference; both TTE-HI and TEE were performed with a contrast agent and a maneuver to provoke RLS in all studies. A total of 15 studies with 1995 patients fulfilled the inclusion criteria. The weighted mean sensitivity and specificity for TTE-HI were 91 and 93 % respectively. Likewise, the positive and negative likelihood ratios were 13.52 and 0.13 respectively. TTE-HI is a reliable, non-invasive test with proficient diagnostic accuracies. The high sensitivity and specificity of TTE-HI make it a useful initial screening test for RLS. If the precise anatomy is required, then TEE can be obtained before scheduling a patient for transcatheter PFO closure.
Appendix
Available only for authorised users
Literature
1.
go back to reference Anzola GP, Magoni M, Guindani M, Rozzini L, Dalla Volta G (1999) Potential source of cerebral embolism in migraine with Aura: a transcranial Doppler study. Neurology 52:1622–1625PubMedCrossRef Anzola GP, Magoni M, Guindani M, Rozzini L, Dalla Volta G (1999) Potential source of cerebral embolism in migraine with Aura: a transcranial Doppler study. Neurology 52:1622–1625PubMedCrossRef
3.
go back to reference Khessali H, Mojadidi MK, Gevorgyan R, Levinson R, Tobis J (2012) The effect of patent foramen ovale closure on visual aura without headache or typical aura with migraine headache. JACC Cardiovasc Interv 5:682–687PubMedCrossRef Khessali H, Mojadidi MK, Gevorgyan R, Levinson R, Tobis J (2012) The effect of patent foramen ovale closure on visual aura without headache or typical aura with migraine headache. JACC Cardiovasc Interv 5:682–687PubMedCrossRef
4.
go back to reference Rengifo-Moreno P, Palacios IF, Junpaparp P, Witzke CF, Morris DL, Romero-Corral A (2013) Patent foramen ovale transcatheter closure vs. medical therapy on recurrent vascular events: a systematic review and meta-analysis of randomized controlled trials. Eur Heart J 34:3342–3352PubMedCrossRef Rengifo-Moreno P, Palacios IF, Junpaparp P, Witzke CF, Morris DL, Romero-Corral A (2013) Patent foramen ovale transcatheter closure vs. medical therapy on recurrent vascular events: a systematic review and meta-analysis of randomized controlled trials. Eur Heart J 34:3342–3352PubMedCrossRef
5.
go back to reference Agarwal S, Bajaj NS, Kumbhani DJ, Tuzcu EM, Kapadia SR (2012) Meta-analysis of transcatheter closure versus medical therapy for patent foramen ovale in prevention of recurrent neurological events after presumed paradoxical embolism. JACC Cardiovasc Interv 5:777–789PubMedCrossRef Agarwal S, Bajaj NS, Kumbhani DJ, Tuzcu EM, Kapadia SR (2012) Meta-analysis of transcatheter closure versus medical therapy for patent foramen ovale in prevention of recurrent neurological events after presumed paradoxical embolism. JACC Cardiovasc Interv 5:777–789PubMedCrossRef
7.
go back to reference Souteyrand G, Motreff P, Lusson JR (2006) Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur J Echocardiogr 7:147–154PubMedCrossRef Souteyrand G, Motreff P, Lusson JR (2006) Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur J Echocardiogr 7:147–154PubMedCrossRef
8.
go back to reference Kuhl HP, Hoffmann R, Merx MW, Franke A, Klötzsch C, Lepper W et al (1999) Transthoracic echocardiography using second harmonic imaging. J Am Coll Cardiol 34:1823–1830PubMedCrossRef Kuhl HP, Hoffmann R, Merx MW, Franke A, Klötzsch C, Lepper W et al (1999) Transthoracic echocardiography using second harmonic imaging. J Am Coll Cardiol 34:1823–1830PubMedCrossRef
9.
go back to reference Ha JW, Shin MS, Kang S, Pyun WB, Jang KJ, Byun KH et al (2001) Enhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging. Am J Cardiol 87:669–671PubMedCrossRef Ha JW, Shin MS, Kang S, Pyun WB, Jang KJ, Byun KH et al (2001) Enhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging. Am J Cardiol 87:669–671PubMedCrossRef
10.
go back to reference Trevelyan J, Steeds RP (2006) Comparison of transthoracic echocardiography with harmonic imaging with transoesophageal echocardiography for the diagnosis of patent foramen ovale. Postgrad Med J 82:613–614PubMedCentralPubMedCrossRef Trevelyan J, Steeds RP (2006) Comparison of transthoracic echocardiography with harmonic imaging with transoesophageal echocardiography for the diagnosis of patent foramen ovale. Postgrad Med J 82:613–614PubMedCentralPubMedCrossRef
11.
go back to reference Van Camp G, Franken P, Melis P, Cosyns B, Schoors D, Vanoverschelde JL (2000) Comparison of transthoracic echocardiography with second harmonic imaging with transesophageal echocardiography in the detection of right to left shunts. Am J Cardiol 86:1284–1287PubMedCrossRef Van Camp G, Franken P, Melis P, Cosyns B, Schoors D, Vanoverschelde JL (2000) Comparison of transthoracic echocardiography with second harmonic imaging with transesophageal echocardiography in the detection of right to left shunts. Am J Cardiol 86:1284–1287PubMedCrossRef
12.
go back to reference Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J (2003) The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 3:25–38PubMedCentralPubMedCrossRef Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J (2003) The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 3:25–38PubMedCentralPubMedCrossRef
13.
15.
16.
go back to reference Walter SD (2002) Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data. Stat Med 21:1237–1256PubMedCrossRef Walter SD (2002) Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data. Stat Med 21:1237–1256PubMedCrossRef
18.
go back to reference Nakanishi Y, Toyoizumi S, Nakajima A (2007) Subgroup analysis in meta-analysis: a comparison of different methods. Jpn J Pharmacoepidemiol/Yakuzaiekigaku 12:13–24 Nakanishi Y, Toyoizumi S, Nakajima A (2007) Subgroup analysis in meta-analysis: a comparison of different methods. Jpn J Pharmacoepidemiol/Yakuzaiekigaku 12:13–24
19.
go back to reference González-Alujas T, Evangelista A, Santamarina E (2011) Diagnosis and quantification of patent foramen ovale. Which is the reference technique? Simultaneous study with transcranial Doppler, transthoracic and transesophageal echocardiography. Rev Esp Cardiol 64:133–139CrossRef González-Alujas T, Evangelista A, Santamarina E (2011) Diagnosis and quantification of patent foramen ovale. Which is the reference technique? Simultaneous study with transcranial Doppler, transthoracic and transesophageal echocardiography. Rev Esp Cardiol 64:133–139CrossRef
20.
go back to reference Buttignoni SC, Khorsand A, Mundigler G, Bergler-Klein J, Heger M, Zehetgruber M et al (2004) Agitated saline versus polygelatine for the echocardiographic assessment of patent foramen ovale. J Am Soc Echocardiogr 17:1059–1065PubMedCrossRef Buttignoni SC, Khorsand A, Mundigler G, Bergler-Klein J, Heger M, Zehetgruber M et al (2004) Agitated saline versus polygelatine for the echocardiographic assessment of patent foramen ovale. J Am Soc Echocardiogr 17:1059–1065PubMedCrossRef
21.
go back to reference Lam YY, Yu CM, Zhang Q, Yan BP, Yip GW (2011) Enhanced detection of patent foramen ovale by systematic transthoracic saline contrast echocardiography. Int J Cardiol 152:24–27PubMedCrossRef Lam YY, Yu CM, Zhang Q, Yan BP, Yip GW (2011) Enhanced detection of patent foramen ovale by systematic transthoracic saline contrast echocardiography. Int J Cardiol 152:24–27PubMedCrossRef
22.
go back to reference Zuber M, Cuculi F, Oechslin E, Erne P, Jenni R (2008) Is transesophageal echocardiography still necessary to exclude patent foramen ovale? Scand Cardiovasc J 42:222–225PubMedCrossRef Zuber M, Cuculi F, Oechslin E, Erne P, Jenni R (2008) Is transesophageal echocardiography still necessary to exclude patent foramen ovale? Scand Cardiovasc J 42:222–225PubMedCrossRef
23.
go back to reference Clarke NR, Timperley J, Kelion AD, Banning AP (2004) Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts. Eur J Echocardiogr 5:176–181PubMedCrossRef Clarke NR, Timperley J, Kelion AD, Banning AP (2004) Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts. Eur J Echocardiogr 5:176–181PubMedCrossRef
24.
go back to reference Daniëls C, Weytjens C, Cosyns B, Schoors D, De Sutter J, Paelinck B et al (2004) Second harmonic transthoracic echocardiography: the new reference screening method for the detection of patent foramen ovale. Eur J Echocardiogr 5:449–452PubMedCrossRef Daniëls C, Weytjens C, Cosyns B, Schoors D, De Sutter J, Paelinck B et al (2004) Second harmonic transthoracic echocardiography: the new reference screening method for the detection of patent foramen ovale. Eur J Echocardiogr 5:449–452PubMedCrossRef
25.
go back to reference Lefèvre J, Lafitte S, Reant P, Perron JM, Roudaut R (2008) Optimization of patent foramen ovale detection by contrast transthoracic echocardiography using second harmonic imaging. Arch Cardiovasc Dis 101:213–219PubMedCrossRef Lefèvre J, Lafitte S, Reant P, Perron JM, Roudaut R (2008) Optimization of patent foramen ovale detection by contrast transthoracic echocardiography using second harmonic imaging. Arch Cardiovasc Dis 101:213–219PubMedCrossRef
26.
go back to reference Madala D, Zaroff JG, Hourigan L, Foster E (2004) Harmonic imaging improves sensitivity at the expense of specificity in the detection of patent foramen ovale. Echocardiography 21:33–36PubMedCrossRef Madala D, Zaroff JG, Hourigan L, Foster E (2004) Harmonic imaging improves sensitivity at the expense of specificity in the detection of patent foramen ovale. Echocardiography 21:33–36PubMedCrossRef
27.
go back to reference Maffè S, Dellavesa P, Zenone F, Paino AM, Paffoni P, Perucca A et al (2010) Transthoracic second harmonic two- and three-dimensional echocardiography for detection of patent foramen ovale. Eur J Echocardiogr 11:57–63PubMedCrossRef Maffè S, Dellavesa P, Zenone F, Paino AM, Paffoni P, Perucca A et al (2010) Transthoracic second harmonic two- and three-dimensional echocardiography for detection of patent foramen ovale. Eur J Echocardiogr 11:57–63PubMedCrossRef
28.
go back to reference Thanigaraj S, Valika A, Zajarias A, Lasala JM, Perez JE (2005) Comparison of transthoracic versus transesophageal echocardiography for detection of right-to-left atrial shunting using agitated saline contrast. Am J Cardiol 96:1007–1010PubMedCrossRef Thanigaraj S, Valika A, Zajarias A, Lasala JM, Perez JE (2005) Comparison of transthoracic versus transesophageal echocardiography for detection of right-to-left atrial shunting using agitated saline contrast. Am J Cardiol 96:1007–1010PubMedCrossRef
29.
go back to reference Hagen PT, Scholz DG, Edwards WD (1984) Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 59:17–20PubMedCrossRef Hagen PT, Scholz DG, Edwards WD (1984) Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 59:17–20PubMedCrossRef
30.
go back to reference Job FP, Ringelstein EB, Grafen Y, Flachskampf FA, Doherty C, Stockmanns A et al (1994) Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol 74:381–384PubMedCrossRef Job FP, Ringelstein EB, Grafen Y, Flachskampf FA, Doherty C, Stockmanns A et al (1994) Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol 74:381–384PubMedCrossRef
31.
go back to reference Tobis JM, Azarbal B (2005) Does patent foramen ovale promote cryptogenic stroke and migraine headache? Tex Heart Inst J 32:362–365PubMedCentralPubMed Tobis JM, Azarbal B (2005) Does patent foramen ovale promote cryptogenic stroke and migraine headache? Tex Heart Inst J 32:362–365PubMedCentralPubMed
32.
go back to reference Harloff A, Handke M, Reinhard M, Geibel A, Hetzel A (2006) Therapeutic strategies after examination by transesophageal echocardiography in 503 patients with ischemic stroke. Stroke 37:859–864PubMedCrossRef Harloff A, Handke M, Reinhard M, Geibel A, Hetzel A (2006) Therapeutic strategies after examination by transesophageal echocardiography in 503 patients with ischemic stroke. Stroke 37:859–864PubMedCrossRef
33.
go back to reference Hilberath JN, Oakes DA, Shernan SK, Bulwer BE, D’Ambra MN, Eltzschig HK (2010) Safety of transesophageal echocardiography. J Am Soc Echocardiogr 23:1115–1127PubMedCrossRef Hilberath JN, Oakes DA, Shernan SK, Bulwer BE, D’Ambra MN, Eltzschig HK (2010) Safety of transesophageal echocardiography. J Am Soc Echocardiogr 23:1115–1127PubMedCrossRef
34.
go back to reference Mojadidi MK, Winoker JS, Roberts SC, Msaouel P, Zaman MO, Gevorgyan R et al (2014) Accuracy of conventional transthoracic echocardiography for the diagnosis of intracardiac right-to-left shunt: a meta-analysis of prospective studies. Echocardiography. doi:10.1111/echo.12583 Mojadidi MK, Winoker JS, Roberts SC, Msaouel P, Zaman MO, Gevorgyan R et al (2014) Accuracy of conventional transthoracic echocardiography for the diagnosis of intracardiac right-to-left shunt: a meta-analysis of prospective studies. Echocardiography. doi:10.​1111/​echo.​12583
35.
go back to reference Mojadidi MK, Roberts SC, Winoker JS, Romero J, Goodman-Meza D, Gevorgyan R, Tobis JM (2014) Accuracy of transcranial Doppler for the diagnosis of intracardiac right-to-left shunt: a bivariate meta-analysis of prospective studies. J Am Coll Cardiol Img 7:236–250CrossRef Mojadidi MK, Roberts SC, Winoker JS, Romero J, Goodman-Meza D, Gevorgyan R, Tobis JM (2014) Accuracy of transcranial Doppler for the diagnosis of intracardiac right-to-left shunt: a bivariate meta-analysis of prospective studies. J Am Coll Cardiol Img 7:236–250CrossRef
36.
go back to reference Gin KG, Huckell VF, Pollick C (1993) Femoral vein delivery of contrast medium enhances transthoracic echocardiographic detection of patent foramen ovale. J Am Coll Cardiol 22:1994–2000PubMedCrossRef Gin KG, Huckell VF, Pollick C (1993) Femoral vein delivery of contrast medium enhances transthoracic echocardiographic detection of patent foramen ovale. J Am Coll Cardiol 22:1994–2000PubMedCrossRef
37.
go back to reference Gevorgyan R, Perlowski A, Shenoda M, Mojadidi MK, Agrawal H, Tobis JM (2014) Sensitivity of brachial versus femoral vein injection of agitated saline to detect right-to-left shunts with transcranial doppler. Catheter Cardiovasc Interv. doi:10.1002/ccd.25391 Gevorgyan R, Perlowski A, Shenoda M, Mojadidi MK, Agrawal H, Tobis JM (2014) Sensitivity of brachial versus femoral vein injection of agitated saline to detect right-to-left shunts with transcranial doppler. Catheter Cardiovasc Interv. doi:10.​1002/​ccd.​25391
38.
go back to reference Pfleger S, Konstantin Haase K, Stark S, Latsch A, Simonis B, Scherhag A et al (2001) Haemodynamic quantification of different provocation manoeuvres by simultaneous measurement of right and left atrial pressure: implications for the echocardiographic detection of persistent foramen ovale. Eur J Echocardiogr 2:88–93PubMedCrossRef Pfleger S, Konstantin Haase K, Stark S, Latsch A, Simonis B, Scherhag A et al (2001) Haemodynamic quantification of different provocation manoeuvres by simultaneous measurement of right and left atrial pressure: implications for the echocardiographic detection of persistent foramen ovale. Eur J Echocardiogr 2:88–93PubMedCrossRef
39.
go back to reference Schneider B, Zienkiewicz T, Jansen V, Hofmann T, Noltenius H, Meinertz T (1996) Diagnosis of patent foramen ovale by transesophageal echocardiography and correlation with autopsy findings. Am J Cardiol 77:1202–1209PubMedCrossRef Schneider B, Zienkiewicz T, Jansen V, Hofmann T, Noltenius H, Meinertz T (1996) Diagnosis of patent foramen ovale by transesophageal echocardiography and correlation with autopsy findings. Am J Cardiol 77:1202–1209PubMedCrossRef
40.
go back to reference Konstadt SN, Louie EK, Black S, Rao TL, Scanlon P (1991) Intraoperative detection of patent foramen ovale by transesophageal echocardiography. Anesthesiology 74:212–216PubMedCrossRef Konstadt SN, Louie EK, Black S, Rao TL, Scanlon P (1991) Intraoperative detection of patent foramen ovale by transesophageal echocardiography. Anesthesiology 74:212–216PubMedCrossRef
41.
go back to reference Chen WJ, Kuan P, Lien WP, Lin FY (1992) Detection of patent foramen ovale by contrast transesophageal echocardiography. Chest 101:1515–1520PubMedCrossRef Chen WJ, Kuan P, Lien WP, Lin FY (1992) Detection of patent foramen ovale by contrast transesophageal echocardiography. Chest 101:1515–1520PubMedCrossRef
42.
go back to reference Spencer MP, Moehring MA, Jesurum J, Gray WA, Olsen JV, Reisman M (2004) Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. J Neuroimaging 14:342–349PubMedCrossRef Spencer MP, Moehring MA, Jesurum J, Gray WA, Olsen JV, Reisman M (2004) Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. J Neuroimaging 14:342–349PubMedCrossRef
Metadata
Title
Two-dimensional echocardiography using second harmonic imaging for the diagnosis of intracardiac right-to-left shunt: a meta-analysis of prospective studies
Authors
Mohammad Khalid Mojadidi
Jared S. Winoker
Scott C. Roberts
Pavlos Msaouel
Rubine Gevorgyan
Ronald Zolty
Publication date
01-06-2014
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 5/2014
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-014-0426-8

Other articles of this Issue 5/2014

The International Journal of Cardiovascular Imaging 5/2014 Go to the issue