Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 1/2012

01-06-2012 | Original Paper

Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes

Authors: Eun-Ju Kang, Ki-Nam Lee, Dong Won Kim, Bo Sung Kim, Sunseob Choi, Byeong-Ho Park, Jong Young Oh

Published in: The International Journal of Cardiovascular Imaging | Special Issue 1/2012

Login to get access

Abstract

The purpose of this study was to investigate the image quality and radiation dose of triple rule-out computed tomography (TROCT) using a 320-row-detector volume CT system to compare the wide-volume and helical modes of this CT system. Sixty-four patients with noncritical chest pain were allocated to one of 2 groups according to the type of CT examination mode used. Group 1 patients were examined using the wide-volume (non-spiral) mode and group 2 patients were examined using the 160-detector row helical mode, with the same contrast injection protocol in both methods [biphasic injection protocol; injection rate of 4 ml/s, median volume, 70 ml (range 65–100 ml)]. Attenuations of the pulmonary trunk, ascending aorta, and coronary arteries were measured in Hounsfield units; a subjective overall patient-based image quality score of 1–3 was awarded to each study. Effective doses, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Average effective dose was significantly lower in group 1 than group 2 (9.7 ± 5.1 vs. 16 ± 5.9 mSv, P < 0.001). The mean attenuation of the main pulmonary trunk was significantly higher in group 1 than group 2 (P = 0.04) and mean attenuations in other vessels were not significant different. SNR and CNR were not significantly different between the groups. The proportion of diagnostic image qualities for chest CT angiography (CTA) was similar between the groups (93.5 vs. 93.9 %). In coronary CTA, group 1 showed a higher proportion of diagnostic image qualities than group 2 (100 vs. 87.9 %). The use of wide-volume mode of 320-detector CT reduces the overall effective radiation dose and results in similar attenuation and image quality for TROCT as compared with the helical mode.
Literature
1.
go back to reference Karlson BW, Herlitz J, Pettersson P et al (1991) Patients admitted to the emergency room with symptoms indicative of acute myocardial infarction. J Intern Med 230(3):251–258PubMedCrossRef Karlson BW, Herlitz J, Pettersson P et al (1991) Patients admitted to the emergency room with symptoms indicative of acute myocardial infarction. J Intern Med 230(3):251–258PubMedCrossRef
2.
go back to reference Ladapo JA, Hoffmann U, Bamberg F et al (2008) Cost-effectiveness of coronary MDCT in the triage of patients with acute chest pain. AJR Am J Roentgenol 191(2):455–463PubMedCrossRef Ladapo JA, Hoffmann U, Bamberg F et al (2008) Cost-effectiveness of coronary MDCT in the triage of patients with acute chest pain. AJR Am J Roentgenol 191(2):455–463PubMedCrossRef
3.
go back to reference Frauenfelder T, Appenzeller P, Karlo C et al (2009) Triple rule-out CT in the emergency department: protocols and spectrum of imaging findings. Eur Radiol 19(4):789–799PubMedCrossRef Frauenfelder T, Appenzeller P, Karlo C et al (2009) Triple rule-out CT in the emergency department: protocols and spectrum of imaging findings. Eur Radiol 19(4):789–799PubMedCrossRef
4.
go back to reference Schertler T, Frauenfelder T, Stolzmann P et al (2009) Triple rule-out CT in patients with suspicion of acute pulmonary embolism: findings and accuracy. Acad Radiol 16(6):708–717PubMedCrossRef Schertler T, Frauenfelder T, Stolzmann P et al (2009) Triple rule-out CT in patients with suspicion of acute pulmonary embolism: findings and accuracy. Acad Radiol 16(6):708–717PubMedCrossRef
5.
go back to reference Krissak R, Henzler T, Prechel A et al. (2010) Triple-rule-out dual-source CT angiography of patients with acute chest pain: dose reduction potential of 100 kV scanning. Eur J Radiol. doi:10.1016/j.ejrad.2010.11.021 Krissak R, Henzler T, Prechel A et al. (2010) Triple-rule-out dual-source CT angiography of patients with acute chest pain: dose reduction potential of 100 kV scanning. Eur J Radiol. doi:10.​1016/​j.​ejrad.​2010.​11.​021
6.
go back to reference Sommer WH, Schenzle JC, Becker CR et al (2010) Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique. Invest Radiol 45(2):64–71PubMedCrossRef Sommer WH, Schenzle JC, Becker CR et al (2010) Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique. Invest Radiol 45(2):64–71PubMedCrossRef
7.
go back to reference Durmus T, Rogalla P, Lembcke A et al (2011) Low-dose triple-rule-out using 320-row-detector volume MDCT—less contrast medium and lower radiation exposure. Eur Radiol 21(7):1416–1423PubMedCrossRef Durmus T, Rogalla P, Lembcke A et al (2011) Low-dose triple-rule-out using 320-row-detector volume MDCT—less contrast medium and lower radiation exposure. Eur Radiol 21(7):1416–1423PubMedCrossRef
8.
go back to reference Husmann L, Alkadhi H, Boehm T et al (2006) Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography. Eur Radiol 16(5):1111–1116PubMedCrossRef Husmann L, Alkadhi H, Boehm T et al (2006) Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography. Eur Radiol 16(5):1111–1116PubMedCrossRef
9.
go back to reference Lembcke A, Wiese TH, Schnorr J et al (2004) Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography: intraindividual comparison in an animal model. Invest Radiol 39(6):357–364PubMedCrossRef Lembcke A, Wiese TH, Schnorr J et al (2004) Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography: intraindividual comparison in an animal model. Invest Radiol 39(6):357–364PubMedCrossRef
10.
go back to reference European Commission (2000) European guidelines on quality criteria for computed tomography, EUR 16262 EN. Office for Official Publications of the European Communities, Luxembourg European Commission (2000) European guidelines on quality criteria for computed tomography, EUR 16262 EN. Office for Official Publications of the European Communities, Luxembourg
11.
go back to reference Feuchtner GM, Jodocy D, Klauser A et al (2010) Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study. Eur J Radiol 75(1):e51–e56PubMedCrossRef Feuchtner GM, Jodocy D, Klauser A et al (2010) Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study. Eur J Radiol 75(1):e51–e56PubMedCrossRef
12.
go back to reference Pflederer T, Rudofsky L, Ropers D et al (2009) Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography. AJR Am J Roentgenol 192(4):1045–1050PubMedCrossRef Pflederer T, Rudofsky L, Ropers D et al (2009) Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography. AJR Am J Roentgenol 192(4):1045–1050PubMedCrossRef
13.
go back to reference Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217(2):430–435PubMed Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217(2):430–435PubMed
14.
go back to reference Dewey M, Teige F, Laule M et al (2007) Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches. Eur Radiol 17(11):2829–2837PubMedCrossRef Dewey M, Teige F, Laule M et al (2007) Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches. Eur Radiol 17(11):2829–2837PubMedCrossRef
15.
go back to reference Schnapauff D, Teige F, Hamm B et al (2009) Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography. Br J Radiol 82(984):969–975PubMedCrossRef Schnapauff D, Teige F, Hamm B et al (2009) Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography. Br J Radiol 82(984):969–975PubMedCrossRef
Metadata
Title
Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes
Authors
Eun-Ju Kang
Ki-Nam Lee
Dong Won Kim
Bo Sung Kim
Sunseob Choi
Byeong-Ho Park
Jong Young Oh
Publication date
01-06-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue Special Issue 1/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0072-y

Other articles of this Special Issue 1/2012

The International Journal of Cardiovascular Imaging 1/2012 Go to the issue