Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2010

Open Access 01-12-2010 | Research article

Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration

Authors: Markus Windolf, Edgardo Ramos Maza, Boyko Gueorguiev, Volker Braunstein, Karsten Schwieger

Published in: BMC Musculoskeletal Disorders | Issue 1/2010

Login to get access

Abstract

Background

In the face of costly fixation hardware with varying performance for treatment of distal humeral fractures, a novel technique (U-Frame) is proposed using conventional implants in a 180° plate arrangement. In this in-vitro study the biomechanical stability of this method was compared with the established technique which utilizes angular stable locking compression plates (LCP) in a 90° configuration.

Methods

An unstable distal 3-part fracture (AO 13-C2.3) was created in eight pairs of human cadaveric humeri. All bone pairs were operated with either the "Frame" technique, where two parallel plates are distally interconnected, or with the LCP technique. The specimens were cyclically loaded in simulated flexion and extension of the arm until failure of the construct occurred. Motion of all fragments was tracked by means of optical motion capturing. Construct stiffness and cycles to failure were identified for all specimens.

Results

Compared to the LCP constructs, the "Frame" technique revealed significant higher construct stiffness in extension of the arm (P = 0.01). The stiffness in flexion was not significantly different (P = 0.16). Number of cycles to failure was found significantly larger for the "Frame" technique (P = 0.01).

Conclusions

In an in-vitro context the proposed method offers enhanced biomechanical stability and at the same time significantly reduces implant costs.
Appendix
Available only for authorised users
Literature
1.
go back to reference Jupiter JB, Morrey BF: Fractures of the distal humerus in the adult. The elbow and its disorders. Edited by: Morrey BF. 1993, Philadelphia, PA: WB Saunders company, 328-366. 2 Jupiter JB, Morrey BF: Fractures of the distal humerus in the adult. The elbow and its disorders. Edited by: Morrey BF. 1993, Philadelphia, PA: WB Saunders company, 328-366. 2
2.
go back to reference Korner J, Lill H, Muller LP, Rommens PM, Schneider E, Linke B: The LCP-concept in the operative treatment of distal humerus fractures--biological, biomechanical and surgical aspects. Injury. 2003, 34 (Suppl 2): B20-B30. 10.1016/j.injury.2003.09.022.CrossRefPubMed Korner J, Lill H, Muller LP, Rommens PM, Schneider E, Linke B: The LCP-concept in the operative treatment of distal humerus fractures--biological, biomechanical and surgical aspects. Injury. 2003, 34 (Suppl 2): B20-B30. 10.1016/j.injury.2003.09.022.CrossRefPubMed
3.
go back to reference Rose SH, Melton LJ, Morrey BF, Ilstrup DM, Riggs BL: Epidemiologic features of humeral fractures. Clin Orthop Relat Res. 1982, 24-30. Rose SH, Melton LJ, Morrey BF, Ilstrup DM, Riggs BL: Epidemiologic features of humeral fractures. Clin Orthop Relat Res. 1982, 24-30.
4.
go back to reference Hahn DM: Current principles of treatment in the clinical practice of articular fractures. Clin Orthop Relat Res. 2004, 27-32. 10.1097/01.blo.0000131234.91264.9e. Hahn DM: Current principles of treatment in the clinical practice of articular fractures. Clin Orthop Relat Res. 2004, 27-32. 10.1097/01.blo.0000131234.91264.9e.
5.
go back to reference Pajarinen J, Bjorkenheim JM: Operative treatment of type C intercondylar fractures of the distal humerus: results after a mean follow-up of 2 years in a series of 18 patients. J Shoulder Elbow Surg. 2002, 11: 48-52. 10.1067/mse.2002.119390.CrossRefPubMed Pajarinen J, Bjorkenheim JM: Operative treatment of type C intercondylar fractures of the distal humerus: results after a mean follow-up of 2 years in a series of 18 patients. J Shoulder Elbow Surg. 2002, 11: 48-52. 10.1067/mse.2002.119390.CrossRefPubMed
6.
go back to reference Srinivasan K, Agarwal M, Matthews SJ, Giannoudis PV: Fractures of the distal humerus in the elderly: is internal fixation the treatment of choice?. Clin Orthop Relat Res. 2005, 222-230. 10.1097/01.blo.0000154010.43568.5b. Srinivasan K, Agarwal M, Matthews SJ, Giannoudis PV: Fractures of the distal humerus in the elderly: is internal fixation the treatment of choice?. Clin Orthop Relat Res. 2005, 222-230. 10.1097/01.blo.0000154010.43568.5b.
8.
go back to reference Korner J, Diederichs G, Arzdorf M, Lill H, Josten C, Schneider E, Linke B: A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma. 2004, 18: 286-293. 10.1097/00005131-200405000-00004.CrossRefPubMed Korner J, Diederichs G, Arzdorf M, Lill H, Josten C, Schneider E, Linke B: A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma. 2004, 18: 286-293. 10.1097/00005131-200405000-00004.CrossRefPubMed
9.
go back to reference Ring D, Jupiter JB: Fractures of the distal humerus. Orthop Clin North Am. 2000, 31: 103-113. 10.1016/S0030-5898(05)70131-0.CrossRefPubMed Ring D, Jupiter JB: Fractures of the distal humerus. Orthop Clin North Am. 2000, 31: 103-113. 10.1016/S0030-5898(05)70131-0.CrossRefPubMed
10.
go back to reference Robinson CM, Hill RM, Jacobs N, Dall G, Court-Brown CM: Adult distal humeral metaphyseal fractures: epidemiology and results of treatment. J Orthop Trauma. 2003, 17: 38-47. 10.1097/00005131-200301000-00006.CrossRefPubMed Robinson CM, Hill RM, Jacobs N, Dall G, Court-Brown CM: Adult distal humeral metaphyseal fractures: epidemiology and results of treatment. J Orthop Trauma. 2003, 17: 38-47. 10.1097/00005131-200301000-00006.CrossRefPubMed
11.
go back to reference Schuster I, Korner J, Arzdorf M, Schwieger K, Diederichs G, Linke B: Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities. J Orthop Trauma. 2008, 22: 113-120. 10.1097/BOT.0b013e3181632cf8.CrossRefPubMed Schuster I, Korner J, Arzdorf M, Schwieger K, Diederichs G, Linke B: Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities. J Orthop Trauma. 2008, 22: 113-120. 10.1097/BOT.0b013e3181632cf8.CrossRefPubMed
12.
go back to reference Colton C, Fernandez Dell'Oca A, Holz U, Kellam J, Ochsner P: AO Principles of Fracture Management. 2003, Stuttgart: Georg Thieme Verlag Colton C, Fernandez Dell'Oca A, Holz U, Kellam J, Ochsner P: AO Principles of Fracture Management. 2003, Stuttgart: Georg Thieme Verlag
13.
go back to reference Sanchez-Sotelo J, Torchia ME, O'Driscoll SW: Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. J Bone Joint Surg Am. 2007, 89: 961-969. 10.2106/JBJS.E.01311.CrossRefPubMed Sanchez-Sotelo J, Torchia ME, O'Driscoll SW: Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. J Bone Joint Surg Am. 2007, 89: 961-969. 10.2106/JBJS.E.01311.CrossRefPubMed
14.
go back to reference Stoffel K, Cunneen S, Morgan R, Nicholls R, Stachowiak G: Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures. J Orthop Res. 2008, 26: 778-784. 10.1002/jor.20528.CrossRefPubMed Stoffel K, Cunneen S, Morgan R, Nicholls R, Stachowiak G: Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures. J Orthop Res. 2008, 26: 778-784. 10.1002/jor.20528.CrossRefPubMed
15.
go back to reference McKee MD, Jupiter JB: Trauma of the adult elbow and Fractures of the Distal Humerus. Skeletal Trauma. Edited by: Browner BD, Jupiter JB, Levine AM, Trafton PG. 1988, Philadelphia, PA: WB Saunders Company, 1455ff- McKee MD, Jupiter JB: Trauma of the adult elbow and Fractures of the Distal Humerus. Skeletal Trauma. Edited by: Browner BD, Jupiter JB, Levine AM, Trafton PG. 1988, Philadelphia, PA: WB Saunders Company, 1455ff-
16.
go back to reference Sanchez-Sotelo J, Torchia ME, O'Driscoll SW: Principle-based internal fixation of distal humerus fractures. Tech Hand Up Extrem Surg. 2001, 5: 179-187. 10.1097/00130911-200112000-00001.CrossRefPubMed Sanchez-Sotelo J, Torchia ME, O'Driscoll SW: Principle-based internal fixation of distal humerus fractures. Tech Hand Up Extrem Surg. 2001, 5: 179-187. 10.1097/00130911-200112000-00001.CrossRefPubMed
17.
go back to reference Self J, Viegas SF, Buford WL, Patterson RM: A comparison of double-plate fixation methods for complex distal humerus fractures. J Shoulder Elbow Surg. 1995, 4: 10-16. 10.1016/S1058-2746(10)80002-3.CrossRefPubMed Self J, Viegas SF, Buford WL, Patterson RM: A comparison of double-plate fixation methods for complex distal humerus fractures. J Shoulder Elbow Surg. 1995, 4: 10-16. 10.1016/S1058-2746(10)80002-3.CrossRefPubMed
18.
go back to reference O'Driscoll SW: Optimizing stability in distal humeral fracture fixation. J Shoulder Elbow Surg. 2005, 14: 186S-194S. 10.1016/j.jse.2004.09.033.CrossRefPubMed O'Driscoll SW: Optimizing stability in distal humeral fracture fixation. J Shoulder Elbow Surg. 2005, 14: 186S-194S. 10.1016/j.jse.2004.09.033.CrossRefPubMed
19.
go back to reference Mueller ME, Nazarian S, Koch P, Schatzker J: The comprehensive classification of fractures of long bones. 1990, New York: SpringerCrossRef Mueller ME, Nazarian S, Koch P, Schatzker J: The comprehensive classification of fractures of long bones. 1990, New York: SpringerCrossRef
20.
go back to reference Jupiter JB: Complex fractures of the distal part of the humerus and associated complications. Instr Course Lect. 1995, 44: 187-198.PubMed Jupiter JB: Complex fractures of the distal part of the humerus and associated complications. Instr Course Lect. 1995, 44: 187-198.PubMed
21.
go back to reference Halls AA, Travill A: Transmission of pressures across the elbow joint. Anat Rec. 1964, 150: 243-247. 10.1002/ar.1091500305.CrossRefPubMed Halls AA, Travill A: Transmission of pressures across the elbow joint. Anat Rec. 1964, 150: 243-247. 10.1002/ar.1091500305.CrossRefPubMed
22.
go back to reference Pauwels F: Pressure distribution in the elbow joint with basic remarks on joint pressure. 11th contribution to the functional anatomy and causal morphology of the supporting apparatus. Z Anat Entwicklungsgesch. 1963, 123: 643-667. 10.1007/BF00523568.CrossRefPubMed Pauwels F: Pressure distribution in the elbow joint with basic remarks on joint pressure. 11th contribution to the functional anatomy and causal morphology of the supporting apparatus. Z Anat Entwicklungsgesch. 1963, 123: 643-667. 10.1007/BF00523568.CrossRefPubMed
23.
go back to reference Windolf M, Muths R, Braunstein V, Gueorguiev B, Hanni M, Schwieger K: Quantification of cancellous bone-compaction due to DHS Blade insertion and influence upon cut-out resistance. Clin Biomech (Bristol, Avon). 2009, 24: 53-58. 10.1016/j.clinbiomech.2008.09.005.CrossRef Windolf M, Muths R, Braunstein V, Gueorguiev B, Hanni M, Schwieger K: Quantification of cancellous bone-compaction due to DHS Blade insertion and influence upon cut-out resistance. Clin Biomech (Bristol, Avon). 2009, 24: 53-58. 10.1016/j.clinbiomech.2008.09.005.CrossRef
24.
go back to reference Jacobson SR, Glisson RR, Urbaniak JR: Comparison of distal humerus fracture fixation: a biomechanical study. J South Orthop Assoc. 1997, 6: 241-249.PubMed Jacobson SR, Glisson RR, Urbaniak JR: Comparison of distal humerus fracture fixation: a biomechanical study. J South Orthop Assoc. 1997, 6: 241-249.PubMed
25.
go back to reference Lever JP, Aksenov SA, Zdero R, Ahn H, McKee MD, Schemitsch EH: Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures. J Orthop Trauma. 2008, 22: 23-29. 10.1097/BOT.0b013e31815c89ce.CrossRefPubMed Lever JP, Aksenov SA, Zdero R, Ahn H, McKee MD, Schemitsch EH: Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures. J Orthop Trauma. 2008, 22: 23-29. 10.1097/BOT.0b013e31815c89ce.CrossRefPubMed
26.
go back to reference Schemitsch EH, Tencer AF, Henley MB: Biomechanical evaluation of methods of internal fixation of the distal humerus. J Orthop Trauma. 1994, 8: 468-475.CrossRefPubMed Schemitsch EH, Tencer AF, Henley MB: Biomechanical evaluation of methods of internal fixation of the distal humerus. J Orthop Trauma. 1994, 8: 468-475.CrossRefPubMed
27.
go back to reference Tejwani NC, Murthy A, Park J, McLaurin TM, Egol KA, Kummer FJ: Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. J Trauma. 2009, 66: 795-799. 10.1097/TA.0b013e318181e53c.CrossRefPubMed Tejwani NC, Murthy A, Park J, McLaurin TM, Egol KA, Kummer FJ: Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. J Trauma. 2009, 66: 795-799. 10.1097/TA.0b013e318181e53c.CrossRefPubMed
28.
go back to reference An KN, Kwak BM, Chao EY, Morrey BF: Determination of muscle and joint forces: a new technique to solve the indeterminate problem. J Biomech Eng. 1984, 106: 364-367. 10.1115/1.3138507.CrossRefPubMed An KN, Kwak BM, Chao EY, Morrey BF: Determination of muscle and joint forces: a new technique to solve the indeterminate problem. J Biomech Eng. 1984, 106: 364-367. 10.1115/1.3138507.CrossRefPubMed
29.
go back to reference Arnander MW, Reeves A, MacLeod IA, Pinto TM, Khaleel A: A biomechanical comparison of plate configuration in distal humerus fractures. J Orthop Trauma. 2008, 22: 332-336. 10.1097/BOT.0b013e31816edbce.CrossRefPubMed Arnander MW, Reeves A, MacLeod IA, Pinto TM, Khaleel A: A biomechanical comparison of plate configuration in distal humerus fractures. J Orthop Trauma. 2008, 22: 332-336. 10.1097/BOT.0b013e31816edbce.CrossRefPubMed
30.
go back to reference Jupiter JB: The management of nonunion and malunion of the distal humerus--a 30-year experience. J Orthop Trauma. 2008, 22: 742-750. 10.1097/BOT.0b013e318188d634.CrossRefPubMed Jupiter JB: The management of nonunion and malunion of the distal humerus--a 30-year experience. J Orthop Trauma. 2008, 22: 742-750. 10.1097/BOT.0b013e318188d634.CrossRefPubMed
31.
go back to reference Mueller ME, Allgoewer M, Schneider R, Willeneger H: Manual of Internal Fixation. 1992, New York: SpringerCrossRef Mueller ME, Allgoewer M, Schneider R, Willeneger H: Manual of Internal Fixation. 1992, New York: SpringerCrossRef
Metadata
Title
Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration
Authors
Markus Windolf
Edgardo Ramos Maza
Boyko Gueorguiev
Volker Braunstein
Karsten Schwieger
Publication date
01-12-2010
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2010
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-11-172

Other articles of this Issue 1/2010

BMC Musculoskeletal Disorders 1/2010 Go to the issue