Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2010

Open Access 01-12-2010 | Research article

Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years

Authors: Stefan Lakemeier, Guenter Aurand, Nina Timmesfeld, Thomas J Heyse, Susanne Fuchs-Winkelmann, Markus D Schofer

Published in: BMC Musculoskeletal Disorders | Issue 1/2010

Login to get access

Abstract

Background

There are multiple revision implant systems currently available for socket revision in revision total hip arthroplasty. Up until now, not all of these systems have been followed up with regards to their long-term use as a revision implantation.
For the first time, this study presents the hemispherical porous-coated socket Plasmacup SC, produced by Aesculap, Tuttlingen, Germany, and the clinical and radiological mid-term results of this revision cup implant.

Methods

Over a period of ten years the Plasmacup SC press-fit-cup was used as a revision implant in 72 consecutive aseptic cases which were included in this retrospective study. The mean follow-up period was 8 years. Bone graft transplantation was performed in 32% of all cases. In 90%, the cup was fixed with additional screws. The follow-up radiographs were analysed with regards to cup migration, osteointegration and osteolysis in the DeLee zones using a computer aided program taking the teardrop figure as a main point of reference. For clinical evaluation the Harris-Hip-Score and the WOMAC-Score were utilized.

Results

At the follow up examination, the mean Harris-Hip-Score was 83.5 points and the mean WOMAC-Score 34.7 points. 93% of all patients were satisfied with the result of the operation. No aseptic cup loosening could be observed and only one cup had to be removed due to infection. No significant longitudinal or transversal cup migration could be observed.

Conclusion

Aesculap's Plasmacup SC is suitable as a cementless cup revision implant. There is stable cup osteointegration, post press-fit implantation, even in the case of major acetabular bone defects.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kärrholm J, Garellick G, Herberts P: Swedish Hip Arthroplasty Register, Annual Report 2006. Department of Orthopedics, Sablgrenska University Hospital. 2006, [http://www.jruorthogu.se] Kärrholm J, Garellick G, Herberts P: Swedish Hip Arthroplasty Register, Annual Report 2006. Department of Orthopedics, Sablgrenska University Hospital. 2006, [http://​www.​jruorthogu.​se]
2.
go back to reference Makela KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V: Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older. An analysis of the Finnish arthroplasty registry. J Bone Joint Surg Am. 2008, 90 (10): 2160-2170. 10.2106/JBJS.G.00870.CrossRefPubMed Makela KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V: Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older. An analysis of the Finnish arthroplasty registry. J Bone Joint Surg Am. 2008, 90 (10): 2160-2170. 10.2106/JBJS.G.00870.CrossRefPubMed
3.
go back to reference Makela KT, Eskelinen A, Paavolainen P, Pulkkinen P, Remes V: Cementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older. Acta Orthop. 2010, Makela KT, Eskelinen A, Paavolainen P, Pulkkinen P, Remes V: Cementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older. Acta Orthop. 2010,
4.
go back to reference Seifert JD, Rader P: Versagensursachen primärer Implantationen. 2007, Berlin: Springer Seifert JD, Rader P: Versagensursachen primärer Implantationen. 2007, Berlin: Springer
5.
go back to reference Engelbrecht DJ, Weber FA, Sweet MB, Jakim I: Long-term results of revision total hip arthroplasty. J Bone Joint Surg Br. 1990, 72 (1): 41-45.PubMed Engelbrecht DJ, Weber FA, Sweet MB, Jakim I: Long-term results of revision total hip arthroplasty. J Bone Joint Surg Br. 1990, 72 (1): 41-45.PubMed
6.
go back to reference Haddad FS, Rayan F: The role of impaction grafting: the when and how. Orthopedics. 2009, 32 (9): 10.3928/01477447-20090728-19. Haddad FS, Rayan F: The role of impaction grafting: the when and how. Orthopedics. 2009, 32 (9): 10.3928/01477447-20090728-19.
7.
go back to reference Sembrano JN, Cheng EY: Acetabular cage survival and analysis of factors related to failure. Clin Orthop Relat Res. 2008, 466 (7): 1657-1665. 10.1007/s11999-008-0183-x.CrossRefPubMedPubMedCentral Sembrano JN, Cheng EY: Acetabular cage survival and analysis of factors related to failure. Clin Orthop Relat Res. 2008, 466 (7): 1657-1665. 10.1007/s11999-008-0183-x.CrossRefPubMedPubMedCentral
8.
go back to reference Siebenrock KA, Trochsler M, Sadri H, Ganz R: [Hooked roof cup in revision of difficult loose hip prosthesis cups. Results after a minimum of 10 years]. Orthopade. 2001, 30 (5): 273-279. 10.1007/s001320050608.CrossRefPubMed Siebenrock KA, Trochsler M, Sadri H, Ganz R: [Hooked roof cup in revision of difficult loose hip prosthesis cups. Results after a minimum of 10 years]. Orthopade. 2001, 30 (5): 273-279. 10.1007/s001320050608.CrossRefPubMed
9.
go back to reference Gotze C, Sippel C, Wendt G, Steinbeck J: [Limits in cementless hip revision total hip arthroplasty. Midterm experience with an oblong revision cup]. Z Orthop Ihre Grenzgeb. 2003, 141 (2): 182-189. 10.1055/s-2003-38652.CrossRefPubMed Gotze C, Sippel C, Wendt G, Steinbeck J: [Limits in cementless hip revision total hip arthroplasty. Midterm experience with an oblong revision cup]. Z Orthop Ihre Grenzgeb. 2003, 141 (2): 182-189. 10.1055/s-2003-38652.CrossRefPubMed
10.
go back to reference Koster G, Willert HG, Kohler HP, Dopkens K: An oblong revision cup for large acetabular defects: design rationale and two- to seven-year follow-up. J Arthroplasty. 1998, 13 (5): 559-569. 10.1016/S0883-5403(98)90056-0.CrossRefPubMed Koster G, Willert HG, Kohler HP, Dopkens K: An oblong revision cup for large acetabular defects: design rationale and two- to seven-year follow-up. J Arthroplasty. 1998, 13 (5): 559-569. 10.1016/S0883-5403(98)90056-0.CrossRefPubMed
11.
go back to reference Gross AE: Revision arthroplasty of the acetabulum with restoration of bone stock. Clin Orthop Relat Res. 1999, 198-207. 10.1097/00003086-199912000-00021. 369 Gross AE: Revision arthroplasty of the acetabulum with restoration of bone stock. Clin Orthop Relat Res. 1999, 198-207. 10.1097/00003086-199912000-00021. 369
12.
go back to reference Lachiewicz PF, Anspach WE, DeMasi R: A prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties. 2-5-year results. J Arthroplasty. 1992, 7 (4): 519-526. 10.1016/S0883-5403(06)80073-2.CrossRefPubMed Lachiewicz PF, Anspach WE, DeMasi R: A prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties. 2-5-year results. J Arthroplasty. 1992, 7 (4): 519-526. 10.1016/S0883-5403(06)80073-2.CrossRefPubMed
13.
go back to reference Jasty M: Jumbo cups and morsalized graft. Orthop Clin North Am. 1998, 29 (2): 249-254. 10.1016/S0030-5898(05)70323-0.CrossRefPubMed Jasty M: Jumbo cups and morsalized graft. Orthop Clin North Am. 1998, 29 (2): 249-254. 10.1016/S0030-5898(05)70323-0.CrossRefPubMed
14.
go back to reference Parratte S, Argenson JN, Flecher X, Aubaniac JM: [Acetabular revision for aseptic loosening in total hip arthroplasty using cementless cup and impacted morselized allograft]. Rev Chir Orthop Reparatrice Appar Mot. 2007, 93 (3): 255-263.CrossRefPubMed Parratte S, Argenson JN, Flecher X, Aubaniac JM: [Acetabular revision for aseptic loosening in total hip arthroplasty using cementless cup and impacted morselized allograft]. Rev Chir Orthop Reparatrice Appar Mot. 2007, 93 (3): 255-263.CrossRefPubMed
15.
go back to reference Christie MJ: Beyond cementless hemispherical sockets. Am J Orthop. 2002, 31 (4): 208-211.PubMed Christie MJ: Beyond cementless hemispherical sockets. Am J Orthop. 2002, 31 (4): 208-211.PubMed
16.
go back to reference Badhe NP, Quinnell RC, Howard PW: The uncemented Bi-Contact total hip arthroplasty. J Arthroplasty. 2002, 17 (7): 896-901. 10.1054/arth.2002.34523.CrossRefPubMed Badhe NP, Quinnell RC, Howard PW: The uncemented Bi-Contact total hip arthroplasty. J Arthroplasty. 2002, 17 (7): 896-901. 10.1054/arth.2002.34523.CrossRefPubMed
17.
go back to reference Paprosky WG, Perona PG, Lawrence JM: Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994, 9 (1): 33-44. 10.1016/0883-5403(94)90135-X.CrossRefPubMed Paprosky WG, Perona PG, Lawrence JM: Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994, 9 (1): 33-44. 10.1016/0883-5403(94)90135-X.CrossRefPubMed
18.
go back to reference Stallforth H, Blömer W: Biomechanische und technologische Aspekte zementfreier Hüftendoprothesen. 1998, Suttgart: Georg Thieme Verlag Stallforth H, Blömer W: Biomechanische und technologische Aspekte zementfreier Hüftendoprothesen. 1998, Suttgart: Georg Thieme Verlag
19.
go back to reference Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969, 51 (4): 737-755.PubMed Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969, 51 (4): 737-755.PubMed
20.
go back to reference Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW: Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988, 15 (12): 1833-1840.PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW: Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988, 15 (12): 1833-1840.PubMed
21.
go back to reference Carlsson AM: Assessment of chronic pain. I. Aspects of the reliability and validity of the visual analogue scale. Pain. 1983, 16 (1): 87-101. 10.1016/0304-3959(83)90088-X.CrossRefPubMed Carlsson AM: Assessment of chronic pain. I. Aspects of the reliability and validity of the visual analogue scale. Pain. 1983, 16 (1): 87-101. 10.1016/0304-3959(83)90088-X.CrossRefPubMed
22.
go back to reference Schonrath F, Hein W, Klima S, Bach A: [Wristing -- a new opportunity in digital migration analysis of uncemented total hip arthroplasty]. Z Orthop Ihre Grenzgeb. 2005, 143 (4): 431-437. 10.1055/s-2005-836746.CrossRefPubMed Schonrath F, Hein W, Klima S, Bach A: [Wristing -- a new opportunity in digital migration analysis of uncemented total hip arthroplasty]. Z Orthop Ihre Grenzgeb. 2005, 143 (4): 431-437. 10.1055/s-2005-836746.CrossRefPubMed
23.
go back to reference Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990, 107-128. 257 Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990, 107-128. 257
24.
go back to reference Masri BA, Masterson EL, Duncan CP: The classification and radiographic evaluation of bone loss in revision hip arthroplasty. Orthop Clin North Am. 1998, 29 (2): 219-227. 10.1016/S0030-5898(05)70320-5.CrossRefPubMed Masri BA, Masterson EL, Duncan CP: The classification and radiographic evaluation of bone loss in revision hip arthroplasty. Orthop Clin North Am. 1998, 29 (2): 219-227. 10.1016/S0030-5898(05)70320-5.CrossRefPubMed
25.
go back to reference DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976, 20-32. 121 DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976, 20-32. 121
26.
go back to reference Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J: Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res. 1997, 94-110. 344 Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J: Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res. 1997, 94-110. 344
27.
go back to reference Krismer M, Stockl B, Fischer M, Bauer R, Mayrhofer P, Ogon M: Early migration predicts late aseptic failure of hip sockets. J Bone Joint Surg Br. 1996, 78 (3): 422-426.PubMed Krismer M, Stockl B, Fischer M, Bauer R, Mayrhofer P, Ogon M: Early migration predicts late aseptic failure of hip sockets. J Bone Joint Surg Br. 1996, 78 (3): 422-426.PubMed
28.
go back to reference Stocks GW, Freeman MA, Evans SJ: Acetabular cup migration. Prediction of aseptic loosening. J Bone Joint Surg Br. 1995, 77 (6): 853-861.PubMed Stocks GW, Freeman MA, Evans SJ: Acetabular cup migration. Prediction of aseptic loosening. J Bone Joint Surg Br. 1995, 77 (6): 853-861.PubMed
29.
go back to reference Raber DA, Czaja S, Morscher EW: Fifteen-year results of the Muller CoCrNiMo straight stem. Arch Orthop Trauma Surg. 2001, 121 (1-2): 38-42. 10.1007/s004020000181.CrossRefPubMed Raber DA, Czaja S, Morscher EW: Fifteen-year results of the Muller CoCrNiMo straight stem. Arch Orthop Trauma Surg. 2001, 121 (1-2): 38-42. 10.1007/s004020000181.CrossRefPubMed
30.
go back to reference Lachiewicz PF, Poon ED: Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement. A follow-up note on the results at five to twelve years. J Bone Joint Surg Am. 1998, 80 (7): 980-984.PubMed Lachiewicz PF, Poon ED: Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement. A follow-up note on the results at five to twelve years. J Bone Joint Surg Am. 1998, 80 (7): 980-984.PubMed
31.
go back to reference Moskal JT, Danisa OA, Shaffrey CI: Isolated revision acetabuloplasty using a porous-coated cementless acetabular component without removal of a well-fixed femoral component. A 3- to 9-year follow-up study. J Arthroplasty. 1997, 12 (7): 719-727. 10.1016/S0883-5403(97)90000-0.CrossRefPubMed Moskal JT, Danisa OA, Shaffrey CI: Isolated revision acetabuloplasty using a porous-coated cementless acetabular component without removal of a well-fixed femoral component. A 3- to 9-year follow-up study. J Arthroplasty. 1997, 12 (7): 719-727. 10.1016/S0883-5403(97)90000-0.CrossRefPubMed
32.
go back to reference Lachiewicz PF, Hussamy OD: Revision of the acetabulum without cement with use of the Harris-Galante porous-coated implant. Two to eight-year results. J Bone Joint Surg Am. 1994, 76 (12): 1834-1839.PubMed Lachiewicz PF, Hussamy OD: Revision of the acetabulum without cement with use of the Harris-Galante porous-coated implant. Two to eight-year results. J Bone Joint Surg Am. 1994, 76 (12): 1834-1839.PubMed
33.
go back to reference Gustke KA: Jumbo cup or high hip center: is bigger better?. J Arthroplasty. 2004, 19 (4 Suppl 1): 120-123. 10.1016/j.arth.2004.02.012.CrossRefPubMed Gustke KA: Jumbo cup or high hip center: is bigger better?. J Arthroplasty. 2004, 19 (4 Suppl 1): 120-123. 10.1016/j.arth.2004.02.012.CrossRefPubMed
34.
go back to reference Obenaus C, Winkler H, Girtler R, Huber M, Schwagerl W: Extra-large press-fit cups without screws for acetabular revision. J Arthroplasty. 2003, 18 (3): 271-277. 10.1054/arth.2003.50049.CrossRefPubMed Obenaus C, Winkler H, Girtler R, Huber M, Schwagerl W: Extra-large press-fit cups without screws for acetabular revision. J Arthroplasty. 2003, 18 (3): 271-277. 10.1054/arth.2003.50049.CrossRefPubMed
35.
go back to reference Patel JV, Masonis JL, Bourne RB, Rorabeck CH: The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty. 2003, 18 (2): 129-133. 10.1054/arth.2003.50038.CrossRefPubMed Patel JV, Masonis JL, Bourne RB, Rorabeck CH: The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty. 2003, 18 (2): 129-133. 10.1054/arth.2003.50038.CrossRefPubMed
36.
go back to reference Whaley AL, Berry DJ, Harmsen WS: Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Joint Surg Am. 2001, 83-A (9): 1352-1357.PubMed Whaley AL, Berry DJ, Harmsen WS: Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Joint Surg Am. 2001, 83-A (9): 1352-1357.PubMed
37.
go back to reference Ito H, Matsuno T, Aoki Y, Minami A: Acetabular components without bulk bone graft in revision surgery: A 5- to 13-year follow-up study. J Arthroplasty. 2003, 18 (2): 134-139. 10.1054/arth.2003.50029.CrossRefPubMed Ito H, Matsuno T, Aoki Y, Minami A: Acetabular components without bulk bone graft in revision surgery: A 5- to 13-year follow-up study. J Arthroplasty. 2003, 18 (2): 134-139. 10.1054/arth.2003.50029.CrossRefPubMed
38.
go back to reference Wirtz DC, Thielemann F, Holz U: [Cement-free revision arthroplasty of the acetabulum--intermediate term outcome with trabecular-oriented acetabulum implant]. Z Orthop Ihre Grenzgeb. 1997, 135 (4): 301-309. 10.1055/s-2008-1039393.CrossRefPubMed Wirtz DC, Thielemann F, Holz U: [Cement-free revision arthroplasty of the acetabulum--intermediate term outcome with trabecular-oriented acetabulum implant]. Z Orthop Ihre Grenzgeb. 1997, 135 (4): 301-309. 10.1055/s-2008-1039393.CrossRefPubMed
39.
go back to reference Elke R, Wagner A, Berli B, Morscher E: [Acetabulum revision. Classifications and treatment possibilities]. Orthopade. 2001, 30 (5): 266-272. 10.1007/s001320050607.CrossRefPubMed Elke R, Wagner A, Berli B, Morscher E: [Acetabulum revision. Classifications and treatment possibilities]. Orthopade. 2001, 30 (5): 266-272. 10.1007/s001320050607.CrossRefPubMed
40.
go back to reference Acklin YP, Berli BJ, Frick W, Elke R, Morscher EW: Nine-year results of Muller cemented titanium Straight Stems in total hip replacement. Arch Orthop Trauma Surg. 2001, 121 (7): 391-398. 10.1007/s004020000254.CrossRefPubMed Acklin YP, Berli BJ, Frick W, Elke R, Morscher EW: Nine-year results of Muller cemented titanium Straight Stems in total hip replacement. Arch Orthop Trauma Surg. 2001, 121 (7): 391-398. 10.1007/s004020000254.CrossRefPubMed
Metadata
Title
Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
Authors
Stefan Lakemeier
Guenter Aurand
Nina Timmesfeld
Thomas J Heyse
Susanne Fuchs-Winkelmann
Markus D Schofer
Publication date
01-12-2010
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2010
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-11-101

Other articles of this Issue 1/2010

BMC Musculoskeletal Disorders 1/2010 Go to the issue