Skip to main content
Top
Published in: Pediatric Cardiology 7/2009

01-10-2009 | Case Report

Transthoracic Echocardiography Guidance of Transcatheter Atrial Septal Defect Closure in Children

Authors: Mahmoud Zaqout, Bert Suys, Hans De Wilde, Daniel De Wolf

Published in: Pediatric Cardiology | Issue 7/2009

Login to get access

Abstract

Transesophageal echocardiography (TEE) guidance is part of interventional closure of secundum atrial septal defect (ASD) in children and adults. However, sometimes TEE is impossible for technical or anatomical reasons. If available, intracardiac echocardiography can be used, but especially in children, transthoracic echocardiography (TTE) can be an easy, safe, and cheap alternative. We report two cases in which TEE was replaced by TTE during percutaneous ASD closure. In the first case VACTERL association with a surgically repaired tracheoesophageal fistula was a relative contraindication to TEE. In the second case, technical failure of the transesophageal probe occurred during the procedure. In both cases the ASD was successfully closed with an atrial septal occluder device under TTE guidance. Using TTE can be sufficient and safe in children with good imaging windows, especially from subcostal views.
Literature
1.
go back to reference Faella HJ, Sciegata AM, Alonso JL, Jmelnitsky L (2003) ASD closure with the amplatzer device. J Interv Cardiol 5:393–397CrossRef Faella HJ, Sciegata AM, Alonso JL, Jmelnitsky L (2003) ASD closure with the amplatzer device. J Interv Cardiol 5:393–397CrossRef
2.
go back to reference Figueroa MI, Balaguru D, McClure C, Kline CH, Radtke WA, Shirali GS (2002) Experience with use of multiplane transesophageal echocardiography to guide closure of atrial septal defects using the amplatzer device. Pediatr Cardiol 4:430–436CrossRef Figueroa MI, Balaguru D, McClure C, Kline CH, Radtke WA, Shirali GS (2002) Experience with use of multiplane transesophageal echocardiography to guide closure of atrial septal defects using the amplatzer device. Pediatr Cardiol 4:430–436CrossRef
3.
go back to reference Harper RW, Mottram PM, McGaw DJ (2002) Closure of secundum atrial septal defects with the amplatzer septal occluder device: techniques and problems. Catheter Cardiovasc Interv 4:508–524CrossRef Harper RW, Mottram PM, McGaw DJ (2002) Closure of secundum atrial septal defects with the amplatzer septal occluder device: techniques and problems. Catheter Cardiovasc Interv 4:508–524CrossRef
4.
go back to reference Hellenbrand WE, Fahey JT, McGowan FX, Weltin GG, Kleinman CS (1999) Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol 2:207–213 Hellenbrand WE, Fahey JT, McGowan FX, Weltin GG, Kleinman CS (1999) Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol 2:207–213
5.
go back to reference Hijazi ZM, Cao Q, Patel HT, Rhodes J, Hanlon KM (2000) Transesophageal echocardiographic results of catheter closure of atrial septal defect in children and adults using the amplatzer device. Am J Cardiol 11:1387–1390CrossRef Hijazi ZM, Cao Q, Patel HT, Rhodes J, Hanlon KM (2000) Transesophageal echocardiographic results of catheter closure of atrial septal defect in children and adults using the amplatzer device. Am J Cardiol 11:1387–1390CrossRef
6.
go back to reference Kardon RE, Sokoloski MC, Levi DS, Perry JS 2nd, Schneider DJ, Allada V, Moore JW (2004) Transthoracic echocardiographic guidance of transcatheter atrial septal defect closure. Am J Cardiol 2:256–260CrossRef Kardon RE, Sokoloski MC, Levi DS, Perry JS 2nd, Schneider DJ, Allada V, Moore JW (2004) Transthoracic echocardiographic guidance of transcatheter atrial septal defect closure. Am J Cardiol 2:256–260CrossRef
7.
go back to reference Koenig PR, Abdulla RI, Cao QL, Hijazi ZM (2003) Use of intracardiac echocardiography to guide catheter closure of atrial communications. Echocardiography 8:781–787CrossRef Koenig PR, Abdulla RI, Cao QL, Hijazi ZM (2003) Use of intracardiac echocardiography to guide catheter closure of atrial communications. Echocardiography 8:781–787CrossRef
8.
go back to reference Losay J, Petit J, Lambert V, Esna G, Berthaux X, Brenot P, Angel C (2001) Closure of secundum atrial septal defects with the amplatzer septal occluder device: techniques and problems. Am Heart J 142(3):544–548PubMedCrossRef Losay J, Petit J, Lambert V, Esna G, Berthaux X, Brenot P, Angel C (2001) Closure of secundum atrial septal defects with the amplatzer septal occluder device: techniques and problems. Am Heart J 142(3):544–548PubMedCrossRef
9.
go back to reference Patel A, Cao QL, Koenig PR, Hijazi ZM (2006) Intracardiac echocardiography to guide closure of atrial septal defects in children less than 15 kilograms. Catheter Cardiovasc Interv 2:287–291CrossRef Patel A, Cao QL, Koenig PR, Hijazi ZM (2006) Intracardiac echocardiography to guide closure of atrial septal defects in children less than 15 kilograms. Catheter Cardiovasc Interv 2:287–291CrossRef
Metadata
Title
Transthoracic Echocardiography Guidance of Transcatheter Atrial Septal Defect Closure in Children
Authors
Mahmoud Zaqout
Bert Suys
Hans De Wilde
Daniel De Wolf
Publication date
01-10-2009
Publisher
Springer-Verlag
Published in
Pediatric Cardiology / Issue 7/2009
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-009-9456-8

Other articles of this Issue 7/2009

Pediatric Cardiology 7/2009 Go to the issue

From Other Journals

From Other Journals