01-12-2022 | Transesophageal Echocardiography | Case report
Two cases of catheters inserted from the femoral vein straying into the hepatic vein, possibly owing to a Eustachian valve: a case report
Authors:
Yoshiaki Takise, Takuma Maeda, Hiroki Yonezawa, Kimito Minami, Masahiro Morinaga, Yoshihiko Ohnishi
Published in:
JA Clinical Reports
|
Issue 1/2022
Login to get access
Abstract
Background
In minimally invasive cardiac surgery (MICS) and extracorporeal membrane oxygenation (ECMO), a guidewire is inserted from the femoral vein (FV) into the right atrium. However, rarely, the guidewire or catheter strays into the hepatic vein (HV) because of the inferior vena cava (IVC)-HV angle. We report two cases in which a guidewire and venous cannula from the FV strayed into the HV, likely owing to a Eustachian valve.
Case presentation
Both patients were women who underwent transesophageal echocardiography-guided FV cannulation. In case 1, a guidewire from the FV strayed into the HV owing to a Eustachian valve. In case 2, ECMO was established postoperatively. Transthoracic echocardiography confirmed the venous cannula had strayed into the HV. Computed tomography indicated IVC-HC angles of 129° (case 1) and 102° (case 2).
Conclusion
A Eustachian valve can impede devices inserted from the FV and even allow them to stray into the HV.