Transcatheter closure of perimembranous ventricular septal defects (VSD) with VSD occluder: early and mid-term results

Authors: Yidong Wei, Xian Wang, Shouyan Zhang, Lei Hou, Yong Wang, Yawei Xu, Qi Sun, Huaibing Zhao

Published in: Heart and Vessels | Issue 4/2012

Login to get access

Abstract

Results of perimembranous ventricular septal defects (pmVSD) transcatheter closure have been reported in the literature, mostly with the Amplatzer VSD device (muscular or eccentric) (AGA Medical Corp., Golden Valley, MN, USA). However, the data of percutaneous closure of pmVSD with VSD occluder (VSD-O) made in China are still limited. We sought to analyze the safety, efficacy, and follow-up results of percutaneous closure of pmVSD with VSD-O made in China. Seventy-eight patients underwent percutaneous closure of pmVSD at our institution between February 2005 and June 2007. A VSD device made in china (Huayishengjie Medical Corp., Beijing, China) was used in all subjects. The mean age at closure was 11 years (range 2.5–44 years). The attempt to place the device was successful in 74 patients (94.9%). The median device size used was 8 mm (range 5–16 mm). No deaths occurred. Total occlusion rate was 62.8% at completion of the procedure, rising to 87.2% at discharge and 99% during the follow-up. A total of eight early complications occurred (10.3%), but in all subjects these were transient. The median follow-up was 32 months. The most significant complication was complete atrioventricular block (cAVB) in the early phase (five subjects, 6.4%) and during the follow-up (one subject, 1.3%), and there was no need for pacemaker implantation in six subjects. Logistic regression analysis showed that the only variable significantly associated with the occurrence of this complication was age at the time of the procedure (p = 0.025; OR 0.22). All subjects experiencing this problem were <5 years old. Percutaneous pmVSD closure used VSD-O made in China is associated with excellent success and closure rates, no mortality, and low morbidity. Nowadays, pmVSD percutaneous closure is a valuable alternative to surgery. Longer follow-up data and improvements in device characteristics are needed to reduce the risk of cAVB.
Literature
1.
go back to reference Chessa M, Carminati M, Butera G (2002) Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. J Am Coll Cardiol 39:1061–1065PubMedCrossRef Chessa M, Carminati M, Butera G (2002) Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. J Am Coll Cardiol 39:1061–1065PubMedCrossRef
2.
go back to reference Butera G, Carminati M, Chessa M (2006) Percutaneous versus surgical closure of secundum atrial septal defect: comparison of early results and complications. Am Heart J 151:228–234PubMedCrossRef Butera G, Carminati M, Chessa M (2006) Percutaneous versus surgical closure of secundum atrial septal defect: comparison of early results and complications. Am Heart J 151:228–234PubMedCrossRef
3.
go back to reference Pass RH, Hijazi Z, Hsu DT (2004) Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial. J Am Coll Cardiol 44:513–519PubMedCrossRef Pass RH, Hijazi Z, Hsu DT (2004) Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial. J Am Coll Cardiol 44:513–519PubMedCrossRef
4.
go back to reference Holzer R, Balzer D, Qi-Ling C, Amplatzer Muscular Ventricular Septal Defect Investigators (2004) Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder. J Am Coll Cardiol 43:1257–1263PubMedCrossRef Holzer R, Balzer D, Qi-Ling C, Amplatzer Muscular Ventricular Septal Defect Investigators (2004) Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder. J Am Coll Cardiol 43:1257–1263PubMedCrossRef
5.
go back to reference Huang TC, Hsieh KS, Lin CC (2008) Clinical results of percutaneous closure of large secundum atrial septal defects in children using the Amplatzer septal occluder. Heart Vessels 23(3):187–192PubMedCrossRef Huang TC, Hsieh KS, Lin CC (2008) Clinical results of percutaneous closure of large secundum atrial septal defects in children using the Amplatzer septal occluder. Heart Vessels 23(3):187–192PubMedCrossRef
6.
go back to reference Hijazi ZM (2003) Device closure of ventricular septal defects. Catheter Cardiovasc Interv 60:107–114PubMedCrossRef Hijazi ZM (2003) Device closure of ventricular septal defects. Catheter Cardiovasc Interv 60:107–114PubMedCrossRef
7.
go back to reference Yu ML, Huang XM, Wang JF (2009) Safety and efficacy of transcatheter closure of large patent ductus arteriosus in adults with a self-expandable occluder. Heart Vessels 24(6):440–445PubMedCrossRef Yu ML, Huang XM, Wang JF (2009) Safety and efficacy of transcatheter closure of large patent ductus arteriosus in adults with a self-expandable occluder. Heart Vessels 24(6):440–445PubMedCrossRef
8.
go back to reference Bass JL, Kalra GS, Arora R (2003) Initial human experience with the Amplatzer perimembranous ventricular septal occluder device. Catheter Cardiovasc Interv 58:238–245PubMedCrossRef Bass JL, Kalra GS, Arora R (2003) Initial human experience with the Amplatzer perimembranous ventricular septal occluder device. Catheter Cardiovasc Interv 58:238–245PubMedCrossRef
9.
go back to reference Hijazi ZM, Hakim F, Haweleh AA (2002) Catheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: initial clinical experience. Catheter Cardiovasc Interv 56:508–515PubMedCrossRef Hijazi ZM, Hakim F, Haweleh AA (2002) Catheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: initial clinical experience. Catheter Cardiovasc Interv 56:508–515PubMedCrossRef
10.
go back to reference Butera G, Carminati M, Chessa M (2007) Transcatheter closure of perimembranous ventricular septal defects early and long-term results. J Am Coll Cardiol 50(12):1189–1195PubMedCrossRef Butera G, Carminati M, Chessa M (2007) Transcatheter closure of perimembranous ventricular septal defects early and long-term results. J Am Coll Cardiol 50(12):1189–1195PubMedCrossRef
11.
go back to reference Kidd L, Discroll DJ, Gersony WH (1993) Second natural history study of congenital heart defects: results of treatment of patients with ventricular septal defects. Circulation 87(Suppl I):138–151 Kidd L, Discroll DJ, Gersony WH (1993) Second natural history study of congenital heart defects: results of treatment of patients with ventricular septal defects. Circulation 87(Suppl I):138–151
12.
go back to reference Arora R, Trehan V, Kumar A (2003) Transcatheter closure of congenital ventricular septal defects. Experience with various devices. J Interv Cardiol 16:83–91PubMedCrossRef Arora R, Trehan V, Kumar A (2003) Transcatheter closure of congenital ventricular septal defects. Experience with various devices. J Interv Cardiol 16:83–91PubMedCrossRef
13.
go back to reference Thanopoulos BD, Tsaousis GS, Karanasios E (2003) Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer asymmetric ventricular septal defect occluder: preliminary experience in children. Heart 89:918–922PubMedCrossRef Thanopoulos BD, Tsaousis GS, Karanasios E (2003) Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer asymmetric ventricular septal defect occluder: preliminary experience in children. Heart 89:918–922PubMedCrossRef
14.
go back to reference Masura J, Gao W, Gavora P (2005) Percutaneous closure of perimembranous ventricular septal defects with the eccentric Amplatzer device: multicenter follow-up study. Pediatr Cardiol 26:216–219PubMedCrossRef Masura J, Gao W, Gavora P (2005) Percutaneous closure of perimembranous ventricular septal defects with the eccentric Amplatzer device: multicenter follow-up study. Pediatr Cardiol 26:216–219PubMedCrossRef
15.
go back to reference Pedra AC, Pedra SRF, Esteves CA (2004) Percutaneous closure of perimembranous ventricular septal defects with the Amplatzer device: technical and morphological considerations. Catheter Cardiovasc Interv 61:403–410PubMedCrossRef Pedra AC, Pedra SRF, Esteves CA (2004) Percutaneous closure of perimembranous ventricular septal defects with the Amplatzer device: technical and morphological considerations. Catheter Cardiovasc Interv 61:403–410PubMedCrossRef
16.
go back to reference Carminati M, Butera G, Chessa M (2005) Transcatheter closure of congenital ventricular septal defect with Amplatzer septal occluders. Am J Cardiol 96(Suppl):52L–58LPubMedCrossRef Carminati M, Butera G, Chessa M (2005) Transcatheter closure of congenital ventricular septal defect with Amplatzer septal occluders. Am J Cardiol 96(Suppl):52L–58LPubMedCrossRef
17.
go back to reference Fu YC, Bass J, Amin Z (2006) Transcatheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder. Results of the US phase I trial. J Am Coll Cardiol 47:319–325PubMedCrossRef Fu YC, Bass J, Amin Z (2006) Transcatheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder. Results of the US phase I trial. J Am Coll Cardiol 47:319–325PubMedCrossRef
18.
go back to reference Pinto RJ, Dalvi BV, Sharma S (2006) Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer asymmetric ventricular septal defect occluder: preliminary experience with 18-month follow-up. Catheter Cardiovasc Interv 68:145–152PubMedCrossRef Pinto RJ, Dalvi BV, Sharma S (2006) Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer asymmetric ventricular septal defect occluder: preliminary experience with 18-month follow-up. Catheter Cardiovasc Interv 68:145–152PubMedCrossRef
19.
go back to reference Holzer R, de Giovanni J, Walsh KP (2006) Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer membranous VSD occluder: immediate and mid-term results of an international registry. Catheter Cardiovasc Interv 68:620–628PubMedCrossRef Holzer R, de Giovanni J, Walsh KP (2006) Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer membranous VSD occluder: immediate and mid-term results of an international registry. Catheter Cardiovasc Interv 68:620–628PubMedCrossRef
20.
go back to reference Yip WC, Zimmermann F, Hijazi ZM (2005) Heart block and empirical therapy after transcatheter closure of perimembranous ventricular septal defect. Catheter Cardiovasc Interv 66:436–441PubMedCrossRef Yip WC, Zimmermann F, Hijazi ZM (2005) Heart block and empirical therapy after transcatheter closure of perimembranous ventricular septal defect. Catheter Cardiovasc Interv 66:436–441PubMedCrossRef
21.
go back to reference Walsh MA, Bialkowski J, Szkutnik M (2006) Atrioventricular block after transcatheter closure of perimembranous ventricular septal defect. Heart 92:1295–1297PubMedCrossRef Walsh MA, Bialkowski J, Szkutnik M (2006) Atrioventricular block after transcatheter closure of perimembranous ventricular septal defect. Heart 92:1295–1297PubMedCrossRef
Metadata
Title
Transcatheter closure of perimembranous ventricular septal defects (VSD) with VSD occluder: early and mid-term results
Authors
Yidong Wei
Xian Wang
Shouyan Zhang
Lei Hou
Yong Wang
Yawei Xu
Qi Sun
Huaibing Zhao
Publication date
01-07-2012
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 4/2012
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-011-0153-1

Other articles of this Issue 4/2012

Heart and Vessels 4/2012 Go to the issue