Skip to main content
Top
Published in: General Thoracic and Cardiovascular Surgery 1/2023

01-11-2022 | Transcatheter Aortic Valve Implantation | Review Article

Troponin as a predictor of outcomes in transcatheter aortic valve implantation: systematic review and meta-analysis

Authors: Jacqueline Nguyen Khuong, Zhengyang Liu, Ryan Campbell, Sarah M. Jackson, Carla Borg Caruana, Dhruvesh M. Ramson, Jahan C. Penny-Dimri, Luke A. Perry

Published in: General Thoracic and Cardiovascular Surgery | Issue 1/2023

Login to get access

Abstract

Background

Transcatheter aortic valve implantation (TAVI) is emerging as a therapeutic gold standard in the management of aortic stenosis. However, post-procedural complications of this procedure are being increasingly recognised. We therefore performed this systematic review and meta-analysis on the prognostic value of elevated troponin prior to TAVI to predict risk of post-procedural complications.

Methods

We searched Medline (Ovid), Embase (Ovid), and the Cochrane Library from inception until May 2022, and included studies on the association between elevated pre-procedural troponin with 30-day mortality, long-term mortality, and post-procedural myocardial injury (PPMI). We generated summary odds ratios (OR) and hazards ratios (HR) using random-effects meta-analysis and performed subgroup analyses to evaluate differences in troponin threshold selection. Inter-study heterogeneity was tested using the I2 test.

Results

We included 10 studies involving 4200 patients. Serum troponin elevation prior to TAVI was significantly associated with long-term mortality [HR = 2.09 (95% CI 1.30–3.36)], but not with 30-day mortality [OR 1.76 (95% CI 0.96–3.22)]. Subgroup analysis showed a trend towards increased effect size and statistical significance for 30-day mortality as troponin elevation was more narrowly defined. Two studies reported on PPMI and found no statistically significant mean difference between groups.

Conclusions

Raised serum troponin is associated with increased long-term mortality following TAVI. Further clarification on the optimal troponin threshold for risk identification is required. High-quality studies that utilise ROC analysis for threshold selection are warranted.
Literature
1.
go back to reference Nkomo VT, Gardin JM, Skelton TN, Gottdiener JS, Scott CG, Enriquez-Sarano M. Burden of valvular heart diseases: a population-based study. Lancet. 2006;368(9540):1005–11.CrossRef Nkomo VT, Gardin JM, Skelton TN, Gottdiener JS, Scott CG, Enriquez-Sarano M. Burden of valvular heart diseases: a population-based study. Lancet. 2006;368(9540):1005–11.CrossRef
2.
go back to reference Hussain AI, Auensen A, Brunborg C, Beitnes JO, Gullestad L, Pettersen KI. Age-dependent morbidity and mortality outcomes after surgical aortic valve replacement. Interact Cardiovasc Thorac Surg. 2018;27(5):650–6.CrossRef Hussain AI, Auensen A, Brunborg C, Beitnes JO, Gullestad L, Pettersen KI. Age-dependent morbidity and mortality outcomes after surgical aortic valve replacement. Interact Cardiovasc Thorac Surg. 2018;27(5):650–6.CrossRef
3.
go back to reference Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106(24):3006–8.CrossRef Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106(24):3006–8.CrossRef
4.
go back to reference Litzler PY, Borz B, Smail H, Baste JM, Nafeh-Bizet C, Gay A, et al. Transapical aortic valve implantation in Rouen: four years’ experience with the Edwards transcatheter prosthesis. Arch Cardiovasc Dis. 2012;105(3):141–5.CrossRef Litzler PY, Borz B, Smail H, Baste JM, Nafeh-Bizet C, Gay A, et al. Transapical aortic valve implantation in Rouen: four years’ experience with the Edwards transcatheter prosthesis. Arch Cardiovasc Dis. 2012;105(3):141–5.CrossRef
5.
go back to reference Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, et al. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2010;122(1):62–9.CrossRef Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, et al. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2010;122(1):62–9.CrossRef
6.
go back to reference Gaede L, Blumenstein J, Liebetrau C, Dorr O, Kim WK, Nef H, et al. Transvascular transcatheter aortic valve implantation in 2017. Clin Res Cardiol. 2019;109:303–14.CrossRef Gaede L, Blumenstein J, Liebetrau C, Dorr O, Kim WK, Nef H, et al. Transvascular transcatheter aortic valve implantation in 2017. Clin Res Cardiol. 2019;109:303–14.CrossRef
7.
go back to reference Ferrer-Sistach E, Lupon J, Cediel G, Teis A, Gual F, Serrano S, et al. High-sensitivity troponin T in asymptomatic severe aortic stenosis. Biomarkers. 2019;24(4):334–40.CrossRef Ferrer-Sistach E, Lupon J, Cediel G, Teis A, Gual F, Serrano S, et al. High-sensitivity troponin T in asymptomatic severe aortic stenosis. Biomarkers. 2019;24(4):334–40.CrossRef
8.
go back to reference Patel N, Kumbhani DJ. Clinical implications of serum biomarkers of cardiac stress in aortic stenosis. Curr Heart Fail Rep. 2018;15(5):281–6.CrossRef Patel N, Kumbhani DJ. Clinical implications of serum biomarkers of cardiac stress in aortic stenosis. Curr Heart Fail Rep. 2018;15(5):281–6.CrossRef
9.
go back to reference Osnabrugge RL, Speir AM, Head SJ, Fonner CE, Fonner E, Kappetein AP, et al. Performance of EuroSCORE II in a large US database: implications for transcatheter aortic valve implantation. Eur J Cardiothorac Surg. 2014;46(3):400–8 (Discussion 8).CrossRef Osnabrugge RL, Speir AM, Head SJ, Fonner CE, Fonner E, Kappetein AP, et al. Performance of EuroSCORE II in a large US database: implications for transcatheter aortic valve implantation. Eur J Cardiothorac Surg. 2014;46(3):400–8 (Discussion 8).CrossRef
10.
go back to reference Chorianopoulos E, Krumsdorf U, Geis N, Pleger ST, Giannitsis E, Katus HA, et al. Preserved prognostic value of preinterventional troponin T levels despite successful TAVI in patients with severe aortic stenosis. Clin Res Cardiol. 2014;103(1):65–72.CrossRef Chorianopoulos E, Krumsdorf U, Geis N, Pleger ST, Giannitsis E, Katus HA, et al. Preserved prognostic value of preinterventional troponin T levels despite successful TAVI in patients with severe aortic stenosis. Clin Res Cardiol. 2014;103(1):65–72.CrossRef
11.
go back to reference Moher D, Liberati A, Tetzlaff J, Altman DG, Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg. 2010;8(5):336–41.CrossRef Moher D, Liberati A, Tetzlaff J, Altman DG, Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg. 2010;8(5):336–41.CrossRef
12.
go back to reference Moons KGM, Wolff RF, Riley RD, Whiting PF, Westwood M, Collins GS, et al. PROBAST: a tool to assess risk of bias and applicability of prediction model studies: explanation and elaboration. Ann Intern Med. 2019;170(1):W1–33.CrossRef Moons KGM, Wolff RF, Riley RD, Whiting PF, Westwood M, Collins GS, et al. PROBAST: a tool to assess risk of bias and applicability of prediction model studies: explanation and elaboration. Ann Intern Med. 2019;170(1):W1–33.CrossRef
13.
go back to reference W V. Conducting meta-analyses in R with the metafor package. Journal of Statistical Software. 2010;36(3):1–48. W V. Conducting meta-analyses in R with the metafor package. Journal of Statistical Software. 2010;36(3):1–48.
14.
go back to reference Wickham H. Ggplot2: elegant graphics for data analysis. New York: Springer; 2009.CrossRef Wickham H. Ggplot2: elegant graphics for data analysis. New York: Springer; 2009.CrossRef
15.
go back to reference Review Manager (RevMan). 5.3 ed: The nordic cochrane centre: The Cochrane Collaboration; 2014. Review Manager (RevMan). 5.3 ed: The nordic cochrane centre: The Cochrane Collaboration; 2014.
16.
go back to reference Kofler M, Reinstadler SJ, Stastny L, Dumfarth J, Reindl M, Wachter K, et al. Prognostic implications of pre-procedural high-sensitivity cardiac troponin T in patients undergoing transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2017;10(22):2345–6.CrossRef Kofler M, Reinstadler SJ, Stastny L, Dumfarth J, Reindl M, Wachter K, et al. Prognostic implications of pre-procedural high-sensitivity cardiac troponin T in patients undergoing transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2017;10(22):2345–6.CrossRef
17.
go back to reference Yong ZY, Wiegerinck EM, Boerlage-van Dijk K, Koch KT, Vis MM, Bouma BJ, et al. Predictors and prognostic value of myocardial injury during transcatheter aortic valve implantation. Circ Cardiovasc Interv. 2012;5(3):415–23.CrossRef Yong ZY, Wiegerinck EM, Boerlage-van Dijk K, Koch KT, Vis MM, Bouma BJ, et al. Predictors and prognostic value of myocardial injury during transcatheter aortic valve implantation. Circ Cardiovasc Interv. 2012;5(3):415–23.CrossRef
18.
go back to reference Sinning JM, Hammerstingl C, Schueler R, Neugebauer A, Keul S, Ghanem A, et al. The prognostic value of acute and chronic troponin elevation after transcatheter aortic valve implantation. EuroIntervention. 2016;11(13):1522–9.CrossRef Sinning JM, Hammerstingl C, Schueler R, Neugebauer A, Keul S, Ghanem A, et al. The prognostic value of acute and chronic troponin elevation after transcatheter aortic valve implantation. EuroIntervention. 2016;11(13):1522–9.CrossRef
19.
go back to reference Liebetrau C, Kim WK, Meyer A, Arsalan M, Gaede L, Blumenstein JM, et al. Identification of periprocedural myocardial infarction using a high-sensitivity troponin I assay in patients who underwent transcatheter aortic valve implantation. Am J Cardiol. 2017;120(7):1180–6.CrossRef Liebetrau C, Kim WK, Meyer A, Arsalan M, Gaede L, Blumenstein JM, et al. Identification of periprocedural myocardial infarction using a high-sensitivity troponin I assay in patients who underwent transcatheter aortic valve implantation. Am J Cardiol. 2017;120(7):1180–6.CrossRef
20.
go back to reference MacCallum RC, Zhang S, Preacher KJ, Rucker DD. On the practice of dichotomization of quantitative variables. Psychol Methods. 2002;7(1):19–40.CrossRef MacCallum RC, Zhang S, Preacher KJ, Rucker DD. On the practice of dichotomization of quantitative variables. Psychol Methods. 2002;7(1):19–40.CrossRef
21.
go back to reference Januzzi JL Jr, Suchindran S, Hoffmann U, Patel MR, Ferencik M, Coles A, et al. Single-molecule hsTnI and short-term risk in stable patients with chest pain. J Am Coll Cardiol. 2019;73(3):251–60.CrossRef Januzzi JL Jr, Suchindran S, Hoffmann U, Patel MR, Ferencik M, Coles A, et al. Single-molecule hsTnI and short-term risk in stable patients with chest pain. J Am Coll Cardiol. 2019;73(3):251–60.CrossRef
22.
go back to reference Akodad M, Spaziano M, Chevalier B, Garot P, Benamer H, Dinan-Zannier A, et al. Prognostic impact of pre-transcatheter and post-transcatheter aortic valve intervention troponin: a large cohort study. J Am Heart Assoc. 2019;8(6):e011111.CrossRef Akodad M, Spaziano M, Chevalier B, Garot P, Benamer H, Dinan-Zannier A, et al. Prognostic impact of pre-transcatheter and post-transcatheter aortic valve intervention troponin: a large cohort study. J Am Heart Assoc. 2019;8(6):e011111.CrossRef
23.
go back to reference Hoffman J, Buckberg G. The myocardial oxygen supply: demand index revisited. J Am Heart Assoc. 2014;3(1):e000285.CrossRef Hoffman J, Buckberg G. The myocardial oxygen supply: demand index revisited. J Am Heart Assoc. 2014;3(1):e000285.CrossRef
24.
go back to reference Panagides V, Alperi A, Mesnier J, Philippon F, Bernier M, Rodes-Cabau J. Heart failure following transcatheter aortic valve replacement. Expert Rev Cardiovasc Ther. 2021;19(8):695–709.CrossRef Panagides V, Alperi A, Mesnier J, Philippon F, Bernier M, Rodes-Cabau J. Heart failure following transcatheter aortic valve replacement. Expert Rev Cardiovasc Ther. 2021;19(8):695–709.CrossRef
25.
go back to reference Shams-Vahdati S, Vand-Rajavpour Z, Paknezhad SP, Piri R, Moghaddasi-Ghezeljeh E, Mirabolfathi S, et al. Cost-effectiveness of cardiac biomarkers as screening test in acute chest pain. J Cardiovasc Thorac Res. 2014;6(1):29–33. Shams-Vahdati S, Vand-Rajavpour Z, Paknezhad SP, Piri R, Moghaddasi-Ghezeljeh E, Mirabolfathi S, et al. Cost-effectiveness of cardiac biomarkers as screening test in acute chest pain. J Cardiovasc Thorac Res. 2014;6(1):29–33.
26.
go back to reference Baldenhofer G, et al. Mid-regional pro-adrenomedullin (MR-proADM) and mid-regional pro-atrial natriuretic peptide (MR-proANP) in severe aortic valve stenosis: association with outcome after transcatheter aortic valve implantation (TAVI). Clin Chem Lab Med. 2016;55(2):275–83. Baldenhofer G, et al. Mid-regional pro-adrenomedullin (MR-proADM) and mid-regional pro-atrial natriuretic peptide (MR-proANP) in severe aortic valve stenosis: association with outcome after transcatheter aortic valve implantation (TAVI). Clin Chem Lab Med. 2016;55(2):275–83.
27.
go back to reference Frank D, Stark S, Lutz M, Weissbrodt A, Freitag-Wolf S, Petzina R, et al. Preprocedural high-sensitive troponin predicts survival after transcatheter aortic valve implantation (TAVI). Int J Cardiol. 2013;169(3):e38–9. Frank D, Stark S, Lutz M, Weissbrodt A, Freitag-Wolf S, Petzina R, et al. Preprocedural high-sensitive troponin predicts survival after transcatheter aortic valve implantation (TAVI). Int J Cardiol. 2013;169(3):e38–9.
28.
go back to reference Kohler WM, Freitag-Wolf S, Lambers M, Lutz M, Niemann PM, Petzina R, et al. Preprocedural but not periprocedural high-sensitive Troponin T levels predict outcome in patients undergoing transcatheter aortic valve implantation. Cardiovasc Ther. 2016;34(6):385–96. Kohler WM, Freitag-Wolf S, Lambers M, Lutz M, Niemann PM, Petzina R, et al. Preprocedural but not periprocedural high-sensitive Troponin T levels predict outcome in patients undergoing transcatheter aortic valve implantation. Cardiovasc Ther. 2016;34(6):385–96.
29.
go back to reference Lindman BR, et al. Prognostic utility of novel biomarkers of cardiovascular stress in patients with aortic stenosis undergoing valve replacement. Heart 2015;101(17):1382–8. Lindman BR, et al. Prognostic utility of novel biomarkers of cardiovascular stress in patients with aortic stenosis undergoing valve replacement. Heart 2015;101(17):1382–8.
Metadata
Title
Troponin as a predictor of outcomes in transcatheter aortic valve implantation: systematic review and meta-analysis
Authors
Jacqueline Nguyen Khuong
Zhengyang Liu
Ryan Campbell
Sarah M. Jackson
Carla Borg Caruana
Dhruvesh M. Ramson
Jahan C. Penny-Dimri
Luke A. Perry
Publication date
01-11-2022
Publisher
Springer Nature Singapore
Published in
General Thoracic and Cardiovascular Surgery / Issue 1/2023
Print ISSN: 1863-6705
Electronic ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-022-01888-2

Other articles of this Issue 1/2023

General Thoracic and Cardiovascular Surgery 1/2023 Go to the issue