Skip to main content
Top
Published in: Nutrition & Metabolism 1/2008

Open Access 01-12-2008 | Brief communication

Total body water estimations in healthy men and women using bioimpedance spectroscopy: a deuterium oxide comparison

Authors: Jordan R Moon, Sarah E Tobkin, Michael D Roberts, Vincent J Dalbo, Chad M Kerksick, Michael G Bemben, Joel T Cramer, Jeffrey R Stout

Published in: Nutrition & Metabolism | Issue 1/2008

Login to get access

Abstract

Background

Total body water (TBW) estimations have been used to estimate body composition, particularly fat-free mass, to aid in nutritional interventions, and to monitor hydration status. In the past, bioimpedance spectroscopy (BIS) devices have been used to estimate TBW. Previous investigations have examined the validity of the XiTRON 4000B (XiTRON Technologies) BIS device for estimating TBW. Recently, a new BIS device (Imp™ SFB7) has become available, claiming greater precision when estimating TBW. The Imp™ SFB7 (SFB7) is based on similar BIS principles, while offering increased portability and a greater range of frequencies when compared to older devices, such as the XiTRON 4000B (4000B). The purpose of this study was to examine the validity of the SFB7 for estimating total body water in healthy college-age men and women compared to the 4000B and deuterium oxide (D2O).

Methods

Twenty-eight Caucasian men and women (14 men, 14 women; 24 ± 4 yrs; 174.6 ± 8.7 cm; 72.80 ± 17.58 kg) had their TBW estimated by the SFB7, the 4000B, and D2O.

Results

Both BIS devices produced similar standard error of estimate (SEE) and r values (SFB7, SEE = 2.12L, r = 0.98; 4000B, SEE = 2.99L, r = 0.96) when compared to D2O, though a significant constant error (CE) was detected for the 4000B (2.26L, p ≤ 0.025). The 4000B produced a larger total error (TE) and CE (TE = 3.81L, CE = 2.26L) when compared to the SFB7 (TE = 2.21L, CE = -0.09L). Additionally, the limits of agreement were larger for the 4000B (-3.88 to 8.39L) than the SFB7 (-4.50 to 4.31L). These results were consistent when sex was analyzed separately, though women produced lower SEE and TE values for both devices.

Conclusion

The 4000B and SFB7 are valid BIS devices when compared to D2O to estimate TBW in college-age Caucasian men and women. Furthermore, the new SFB7 device displayed greater precision in comparison to the 4000B, which may decrease the error when estimating TBW on an individual basis.
Appendix
Available only for authorised users
Literature
1.
go back to reference Wang ZM, Deurenberg P, Guo SS, Pietrobelli A, Wang J, Pierson RN Jr., Heymsfield SB: Six-compartment body composition model: inter-method comparisons of total body fat measurement. Int J Obes Relat Metab Disord 1998,22(4):329-337. 10.1038/sj.ijo.0800590CrossRef Wang ZM, Deurenberg P, Guo SS, Pietrobelli A, Wang J, Pierson RN Jr., Heymsfield SB: Six-compartment body composition model: inter-method comparisons of total body fat measurement. Int J Obes Relat Metab Disord 1998,22(4):329-337. 10.1038/sj.ijo.0800590CrossRef
2.
go back to reference Schoeller DA: Hydrometry. In Human body composition. 2nd edition. Champaign, IL , Human Kinetics; 2005. Schoeller DA: Hydrometry. In Human body composition. 2nd edition. Champaign, IL , Human Kinetics; 2005.
3.
go back to reference Bellizzi V, Scalfi L, Terracciano V, De Nicola L, Minutolo R, Marra M, Guida B, Cianciaruso B, Conte G, Di Iorio BR: Early changes in bioelectrical estimates of body composition in chronic kidney disease. J Am Soc Nephrol 2006,17(5):1481-1487. 10.1681/ASN.2005070756CrossRef Bellizzi V, Scalfi L, Terracciano V, De Nicola L, Minutolo R, Marra M, Guida B, Cianciaruso B, Conte G, Di Iorio BR: Early changes in bioelectrical estimates of body composition in chronic kidney disease. J Am Soc Nephrol 2006,17(5):1481-1487. 10.1681/ASN.2005070756CrossRef
4.
go back to reference Dumler F, Kilates C: Prospective nutritional surveillance using bioelectrical impedance in chronic kidney disease patients. J Ren Nutr 2005,15(1):148-151. 10.1053/j.jrn.2004.09.013CrossRef Dumler F, Kilates C: Prospective nutritional surveillance using bioelectrical impedance in chronic kidney disease patients. J Ren Nutr 2005,15(1):148-151. 10.1053/j.jrn.2004.09.013CrossRef
5.
go back to reference Raffaitin C, Lasseur C, Chauveau P, Barthe N, Gin H, Combe C, Rigalleau V: Nutritional status in patients with diabetes and chronic kidney disease: a prospective study. Am J Clin Nutr 2007,85(1):96-101. Raffaitin C, Lasseur C, Chauveau P, Barthe N, Gin H, Combe C, Rigalleau V: Nutritional status in patients with diabetes and chronic kidney disease: a prospective study. Am J Clin Nutr 2007,85(1):96-101.
6.
go back to reference Zamojska S, Szklarek M, Niewodniczy M, Nowicki M: Correlates of habitual physical activity in chronic haemodialysis patients. Nephrol Dial Transplant 2006,21(5):1323-1327. 10.1093/ndt/gfi323CrossRef Zamojska S, Szklarek M, Niewodniczy M, Nowicki M: Correlates of habitual physical activity in chronic haemodialysis patients. Nephrol Dial Transplant 2006,21(5):1323-1327. 10.1093/ndt/gfi323CrossRef
7.
go back to reference Armstrong LE, Kenefick RW, Castellani JW, Riebe D, Kavouras SA, Kuznicki JT, Maresh CM: Bioimpedance spectroscopy technique: intra-, extracellular, and total body water. Med Sci Sports Exerc 1997,29(12):1657-1663.CrossRef Armstrong LE, Kenefick RW, Castellani JW, Riebe D, Kavouras SA, Kuznicki JT, Maresh CM: Bioimpedance spectroscopy technique: intra-, extracellular, and total body water. Med Sci Sports Exerc 1997,29(12):1657-1663.CrossRef
8.
go back to reference Patel RV, Matthie JR, Withers PO, Peterson EL, Zarowitz BJ: Estimation of total body and extracellular water using single- and multiple-frequency bioimpedance. The Annals of pharmacotherapy 1994,28(5):565-569. Patel RV, Matthie JR, Withers PO, Peterson EL, Zarowitz BJ: Estimation of total body and extracellular water using single- and multiple-frequency bioimpedance. The Annals of pharmacotherapy 1994,28(5):565-569.
9.
go back to reference Van Loan MD, Mayclin PL: Use of multi-frequency bioelectrical impedance analysis for the estimation of extracellular fluid. European journal of clinical nutrition 1992,46(2):117-124. Van Loan MD, Mayclin PL: Use of multi-frequency bioelectrical impedance analysis for the estimation of extracellular fluid. European journal of clinical nutrition 1992,46(2):117-124.
10.
go back to reference van Marken Lichtenbelt WD, Westerterp KR, Wouters L, Luijendijk SC: Validation of bioelectrical-impedance measurements as a method to estimate body-water compartments. Am J Clin Nutr 1994,60(2):159-166. van Marken Lichtenbelt WD, Westerterp KR, Wouters L, Luijendijk SC: Validation of bioelectrical-impedance measurements as a method to estimate body-water compartments. Am J Clin Nutr 1994,60(2):159-166.
11.
go back to reference Van Loan MD, Withers P, Matthie J, Mayclin PL: Use of bioimpedance spectroscopy to determine extracellular fluid, intracellular fluid, total body water, and fat-free mass. Basic Life Sciences 1993, 60: 67-70. Van Loan MD, Withers P, Matthie J, Mayclin PL: Use of bioimpedance spectroscopy to determine extracellular fluid, intracellular fluid, total body water, and fat-free mass. Basic Life Sciences 1993, 60: 67-70.
12.
go back to reference Matthie J, Zarowitz B, De Lorenzo A, Andreoli A, Katzarski K, Pan G, Withers P: Analytic assessment of the various bioimpedance methods used to estimate body water. J Appl Physiol 1998,84(5):1801-1816. Matthie J, Zarowitz B, De Lorenzo A, Andreoli A, Katzarski K, Pan G, Withers P: Analytic assessment of the various bioimpedance methods used to estimate body water. J Appl Physiol 1998,84(5):1801-1816.
13.
go back to reference Buchholz AC, Bartok C, Schoeller DA: The validity of bioelectrical impedance models in clinical populations. Nutr Clin Pract 2004,19(5):433-446.CrossRef Buchholz AC, Bartok C, Schoeller DA: The validity of bioelectrical impedance models in clinical populations. Nutr Clin Pract 2004,19(5):433-446.CrossRef
14.
go back to reference Armstrong LE: Hydration assessment techniques. Nutrition reviews 2005,63(6 Pt 2):S40-54. 10.1301/nr.2005.jun.S40-S54CrossRef Armstrong LE: Hydration assessment techniques. Nutrition reviews 2005,63(6 Pt 2):S40-54. 10.1301/nr.2005.jun.S40-S54CrossRef
15.
go back to reference Hanai T: Electrical Properties of Emulsions in Emulsion Science, Chap. 5. London-New York , Academic Press; 1968. Hanai T: Electrical Properties of Emulsions in Emulsion Science, Chap. 5. London-New York , Academic Press; 1968.
16.
go back to reference Wong WW, Lee LS, Klein PD: Deuterium and oxygen-18 measurements on microliter samples of urine, plasma, saliva, and human milk. Am J Clin Nutr 1987,45(5):905-913. Wong WW, Lee LS, Klein PD: Deuterium and oxygen-18 measurements on microliter samples of urine, plasma, saliva, and human milk. Am J Clin Nutr 1987,45(5):905-913.
17.
go back to reference Schoeller DA, van Santen E, Peterson DW, Dietz W, Jaspan J, Klein PD: Total body water measurement in humans with 18O and 2H labeled water. Am J Clin Nutr 1980,33(12):2686-2693. Schoeller DA, van Santen E, Peterson DW, Dietz W, Jaspan J, Klein PD: Total body water measurement in humans with 18O and 2H labeled water. Am J Clin Nutr 1980,33(12):2686-2693.
18.
go back to reference Lohman TG: Human Body Composition. Champaign, IL , Human Kinetics; 1996. Lohman TG: Human Body Composition. Champaign, IL , Human Kinetics; 1996.
19.
go back to reference Heyward VH, Wagner DR: Applied Body Composition Assessments. Champaign, IL , Human Kinetics; 2004. Heyward VH, Wagner DR: Applied Body Composition Assessments. Champaign, IL , Human Kinetics; 2004.
20.
go back to reference Keppel GTDW: Design and Analysis: A Researchers Handbook. 4th edition. Upper Saddle River, NJ , Prentice Hall; 2004. Keppel GTDW: Design and Analysis: A Researchers Handbook. 4th edition. Upper Saddle River, NJ , Prentice Hall; 2004.
21.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986,1(8476):307-310.CrossRef Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986,1(8476):307-310.CrossRef
22.
go back to reference Lohman TG: Advances in body composition assessment. Champaign, IL , Human Kinetics; 1992. Lohman TG: Advances in body composition assessment. Champaign, IL , Human Kinetics; 1992.
Metadata
Title
Total body water estimations in healthy men and women using bioimpedance spectroscopy: a deuterium oxide comparison
Authors
Jordan R Moon
Sarah E Tobkin
Michael D Roberts
Vincent J Dalbo
Chad M Kerksick
Michael G Bemben
Joel T Cramer
Jeffrey R Stout
Publication date
01-12-2008
Publisher
BioMed Central
Published in
Nutrition & Metabolism / Issue 1/2008
Electronic ISSN: 1743-7075
DOI
https://doi.org/10.1186/1743-7075-5-7

Other articles of this Issue 1/2008

Nutrition & Metabolism 1/2008 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine