Abstract

Objectives

To analyse the diagnostic utility of flat-detector computed tomography imaging (FD-CT) in patients with congenital heart disease, including the value of image fusion to overlay three-dimensional (3D) reconstructions on fluoroscopic images during catheter-based interventions.

Methods

We retrospectively analysed 62 consecutive paediatric patients in whom FD-CT was used during catheterisation of congenital heart disease. Expert operators rated the clinical value of FD-CT over conventional fluoroscopic imaging. Added radiation exposure and contrast medium volume were evaluated.

Results

During a 12-month period, FD-CT was performed in 62 out of 303 cardiac catheterisations. Median patient age was 3.5 years. In 32/62 cases, FD-CT was used for diagnostic purposes, in 30/62 cases it was used in the context of interventions. Diagnostic utility was never rated as “misleading”. It was classified as “not useful” in six cases (9.7%), “useful” in 18 cases (29.0%), “very useful” in 37 cases (59.7%) and “essential” in one case (1.6%). The median added dose-area product was 111.0 μGym2, the required additional quantity of contrast medium was 1.6 ml/kg.

Conclusion

FD-CT provides useful diagnostic information in most of the patients investigated for congenital heart disease. The added radiation exposure and contrast medium volume are reasonable.
Literature
1.
go back to reference Fahrig R, Fox AJ, Lownie S, Holdsworth DW (1997) Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results. AJNR Am J Neuroradiol 18:1507–1514PubMed Fahrig R, Fox AJ, Lownie S, Holdsworth DW (1997) Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results. AJNR Am J Neuroradiol 18:1507–1514PubMed
2.
go back to reference Gupta R, Cheung AC, Bartling SH et al (2008) Flat-panel volume CT: fundamental principles, technology, and applications. RadioGraphics 28:2009–2022PubMedCrossRef Gupta R, Cheung AC, Bartling SH et al (2008) Flat-panel volume CT: fundamental principles, technology, and applications. RadioGraphics 28:2009–2022PubMedCrossRef
3.
go back to reference Kalender WA, Kyriakou Y (2007) Flat-detector computed tomography (FD-CT). Eur Radiol 17:2767–2779PubMedCrossRef Kalender WA, Kyriakou Y (2007) Flat-detector computed tomography (FD-CT). Eur Radiol 17:2767–2779PubMedCrossRef
4.
go back to reference Meyer BC, Frericks BB, Albrecht T, Wolf KJ, Wacker FK (2007) Contrast-enhanced abdominal angiographic CT for intra-abdominal tumor embolization: a new tool for vessel and soft tissue visualization. Cardiovasc Intervent Radiol 30:743–749PubMedCrossRef Meyer BC, Frericks BB, Albrecht T, Wolf KJ, Wacker FK (2007) Contrast-enhanced abdominal angiographic CT for intra-abdominal tumor embolization: a new tool for vessel and soft tissue visualization. Cardiovasc Intervent Radiol 30:743–749PubMedCrossRef
5.
go back to reference Nolker G, Gutleben KJ, Marschang H et al (2008) Three-dimensional left atrial and esophagus reconstruction using cardiac C-arm computed tomography with image integration into fluoroscopic views for ablation of atrial fibrillation: accuracy of a novel modality in comparison with multislice computed tomography. Hear Rhythm 5:1651–1657CrossRef Nolker G, Gutleben KJ, Marschang H et al (2008) Three-dimensional left atrial and esophagus reconstruction using cardiac C-arm computed tomography with image integration into fluoroscopic views for ablation of atrial fibrillation: accuracy of a novel modality in comparison with multislice computed tomography. Hear Rhythm 5:1651–1657CrossRef
6.
go back to reference Struffert T, Doerfler A (2009) Flat-detector computed tomography in diagnostic and interventional neuroradiology. Radiologe 49:820–829PubMedCrossRef Struffert T, Doerfler A (2009) Flat-detector computed tomography in diagnostic and interventional neuroradiology. Radiologe 49:820–829PubMedCrossRef
7.
go back to reference Struffert T, Richter G, Engelhorn T et al (2009) Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases. Eur Radiol 19(3):619–625PubMedCrossRef Struffert T, Richter G, Engelhorn T et al (2009) Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases. Eur Radiol 19(3):619–625PubMedCrossRef
8.
go back to reference Walther T, Schuler G, Borger MA et al (2010) Transapical aortic valve implantation in 100 consecutive patients: comparison to propensity-matched conventional aortic valve replacement. Eur Heart J 31:1398–1403PubMedCrossRef Walther T, Schuler G, Borger MA et al (2010) Transapical aortic valve implantation in 100 consecutive patients: comparison to propensity-matched conventional aortic valve replacement. Eur Heart J 31:1398–1403PubMedCrossRef
9.
go back to reference Glatz AC, Zhu X, Gillespie MJ, Hanna BD, Rome JJ (2010) Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease. JACC Cardiovasc Imaging 3:1149–1157PubMedCrossRef Glatz AC, Zhu X, Gillespie MJ, Hanna BD, Rome JJ (2010) Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease. JACC Cardiovasc Imaging 3:1149–1157PubMedCrossRef
10.
go back to reference Kyriakou Y, Struffert T, Dorfler A, Kalender WA (2009) Basic principles of flat detector computed tomography (FD-CT). Radiologe 49:811–819PubMedCrossRef Kyriakou Y, Struffert T, Dorfler A, Kalender WA (2009) Basic principles of flat detector computed tomography (FD-CT). Radiologe 49:811–819PubMedCrossRef
11.
go back to reference Kyriakou Y, Deak P, Langner O, Kalender WA (2008) Concepts for dose determination in flat-detector CT. Phys Med Biol 53:3551–3566PubMedCrossRef Kyriakou Y, Deak P, Langner O, Kalender WA (2008) Concepts for dose determination in flat-detector CT. Phys Med Biol 53:3551–3566PubMedCrossRef
12.
go back to reference Shope TB, Gagne RM, Johnson GC (1981) A method for describing the doses delivered by transmission x-ray computed tomography. Med Phys 8:488–495PubMedCrossRef Shope TB, Gagne RM, Johnson GC (1981) A method for describing the doses delivered by transmission x-ray computed tomography. Med Phys 8:488–495PubMedCrossRef
13.
go back to reference Fahrig R, Dixon R, Payne T, Morin RL, Ganguly A, Strobel N (2006) Dose and image quality for a cone-beam C-arm CT system. Med Phys 33:4541–4550PubMedCrossRef Fahrig R, Dixon R, Payne T, Morin RL, Ganguly A, Strobel N (2006) Dose and image quality for a cone-beam C-arm CT system. Med Phys 33:4541–4550PubMedCrossRef
14.
go back to reference Ellis AR, Mulvihill D, Bradley SM, Hlavacek AM (2010) Utility of computed tomographic angiography in the pre-operative planning for initial and repeat congenital cardiovascular surgery. Cardiol Young 20:262–268PubMedCrossRef Ellis AR, Mulvihill D, Bradley SM, Hlavacek AM (2010) Utility of computed tomographic angiography in the pre-operative planning for initial and repeat congenital cardiovascular surgery. Cardiol Young 20:262–268PubMedCrossRef
15.
go back to reference Samyn MM (2004) A review of the complementary information available with cardiac magnetic resonance imaging and multi-slice computed tomography (CT) during the study of congenital heart disease. Int J Cardiovasc Imaging 20:569–578PubMedCrossRef Samyn MM (2004) A review of the complementary information available with cardiac magnetic resonance imaging and multi-slice computed tomography (CT) during the study of congenital heart disease. Int J Cardiovasc Imaging 20:569–578PubMedCrossRef
16.
go back to reference Struffert T, Deuerling-Zheng Y, Kloska S et al (2010) Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT. Eur Radiol 21:882–889PubMedCrossRef Struffert T, Deuerling-Zheng Y, Kloska S et al (2010) Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT. Eur Radiol 21:882–889PubMedCrossRef
17.
go back to reference Struffert T, Hertel V, Kyriakou Y et al (2010) Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: comparison of image quality and radiation dose. Acta Otolaryngol 130:443–452PubMedCrossRef Struffert T, Hertel V, Kyriakou Y et al (2010) Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: comparison of image quality and radiation dose. Acta Otolaryngol 130:443–452PubMedCrossRef
18.
go back to reference Noble S, Miro J, Yong G, Bonan R, Tardif JC, Ibrahim R (2009) Rapid pacing rotational angiography with three-dimensional reconstruction: use and benefits in structural heart disease interventions. EuroIntervention 5:244–249PubMedCrossRef Noble S, Miro J, Yong G, Bonan R, Tardif JC, Ibrahim R (2009) Rapid pacing rotational angiography with three-dimensional reconstruction: use and benefits in structural heart disease interventions. EuroIntervention 5:244–249PubMedCrossRef
19.
go back to reference Krishnaswamy A, Tuzcu EM, Kapadia SR (2010) Three-dimensional computed tomography in the cardiac catheterization laboratory. Catheter Cardiovasc Interv 77:860–865CrossRef Krishnaswamy A, Tuzcu EM, Kapadia SR (2010) Three-dimensional computed tomography in the cardiac catheterization laboratory. Catheter Cardiovasc Interv 77:860–865CrossRef
20.
go back to reference Lanning C, Chen SY, Hansgen A, Chang D, Chan KC, Shandas R (2004) Dynamic three-dimensional reconstruction and modeling of cardiovascular anatomy in children with congenital heart disease using biplane angiography. Biomed Sci Instrum 40:200–205PubMed Lanning C, Chen SY, Hansgen A, Chang D, Chan KC, Shandas R (2004) Dynamic three-dimensional reconstruction and modeling of cardiovascular anatomy in children with congenital heart disease using biplane angiography. Biomed Sci Instrum 40:200–205PubMed
21.
go back to reference Achenbach S, Marwan M, Ropers D et al (2010) Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 31:340–346PubMedCrossRef Achenbach S, Marwan M, Ropers D et al (2010) Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 31:340–346PubMedCrossRef
22.
go back to reference Lell M, Hinkmann F, Anders K et al (2009) High-pitch electrocardiogram-triggered computed tomography of the chest: initial results. Invest Radiol 44:728–733PubMedCrossRef Lell M, Hinkmann F, Anders K et al (2009) High-pitch electrocardiogram-triggered computed tomography of the chest: initial results. Invest Radiol 44:728–733PubMedCrossRef
23.
go back to reference Lell MM, May M, Deak P et al (2011) High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Invest Radiol 46:116–123PubMedCrossRef Lell MM, May M, Deak P et al (2011) High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Invest Radiol 46:116–123PubMedCrossRef
Metadata
Title
The value of flat-detector computed tomography during catheterisation of congenital heart disease
Authors
Martin Glöckler
Andreas Koch
Verena Greim
Amira Shabaiek
Andrè Rüffer
Robert Cesnjevar
Stephan Achenbach
Sven Dittrich
Publication date
01-12-2011
Publisher
Springer-Verlag
Published in
European Radiology / Issue 12/2011
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-011-2214-3

Other articles of this Issue 12/2011

European Radiology 12/2011 Go to the issue