Skip to main content
Top
Published in: Journal of Thrombosis and Thrombolysis 2/2011

01-02-2011

The validity of the INR system for patients with liver disease

Author: Armando Tripodi

Published in: Journal of Thrombosis and Thrombolysis | Issue 2/2011

Login to get access

Excerpt

I read with interest the paper by Wei et al. [1], published recently in the Journal of Thrombosis and Thrombolysis on the assessment of the validity of the INR system for patients with liver disease and wish to make comments. The authors measured the INR with different commercial thromboplastins for a cohort of patients with liver disease and a cohort of patients stabilized on vitamin K antagonists (VKA). While the between-thromboplastin INRs for the patients with liver disease were significantly different, those for the patients on VKA were not. The obvious conclusion is that the INR (as it is calibrated for patients on VKA and here called INRvka) is not valid for patients with liver disease and, therefore, the model of end stage liver disease (MELD) score, once proposed as an objective index to prioritize patients for liver transplantation, would not allow parity of organ allocation. In their discussion Wei et al. [1], ignored at least seven of the many papers published over the last few years on this topic. Here few examples. Trotter et al. [2], were among the first in 2004 to show that the MELD score was not effective in securing parity of organ allocation. Other papers have consistently shown (from 1994 to 1999) that the INR, devised for patients on VKA, is not valid for patients with chronic liver disease [3, 4]. In 2007, Tripodi et al. [5] and Bellest et al. [6] reported independently on the same issue of Hepatology that the INRvka is not valid for patients with chronic liver disease as shown by the fact that the MELD, calculated by including in the equation the INRvka, depends on the thromboplastin used for testing. In the same papers these authors have independently shown that an alternative system of ISI calibration, provisionally called ISIliver (as opposed to the ISIvka) [5] can be obtained by inserting into the calibration plot, plasmas from patients with chronic liver disease instead of plasmas from patients on VKA [5, 6]. This alternative system of calibration proved effective in minimizing between-thromboplastin MELD results. More recently, Sermon et al. [7], confirmed these results, and Tripodi et al. [8] extended this model of ISIliver calibration to portable coagulation monitors. Finally, a review article on this topic has been published in the Journal of Thrombosis and Haemostasis in 2009 [9] and official recommendations have been issued independently by the International Society on Thrombosis and Haemostasis [10] and by the American Journal of Transplantation [11]. Surprisingly, some of the above papers [26, 8, 9] that appeared in the literature well before the publication of Wei et al. [1] have escaped their attention. …
Literature
1.
go back to reference Wei Y, Li J, Zhang L, Zheng D, Shi B, Cong Y (2010) Assessment of validity of INR system for patients with liver disease associated with viral hepatitis. J Thromb Thrombolysis 30:84–89CrossRefPubMed Wei Y, Li J, Zhang L, Zheng D, Shi B, Cong Y (2010) Assessment of validity of INR system for patients with liver disease associated with viral hepatitis. J Thromb Thrombolysis 30:84–89CrossRefPubMed
2.
go back to reference Trotter JF, Brimhall B, Arjal R (2004) Specific laboratory methodologies achieve higher model for end stage liver disease (MELD) scores for patients listed for liver transplantation. Liver Transplant 10:995–1000CrossRef Trotter JF, Brimhall B, Arjal R (2004) Specific laboratory methodologies achieve higher model for end stage liver disease (MELD) scores for patients listed for liver transplantation. Liver Transplant 10:995–1000CrossRef
3.
go back to reference Kovacs MJ, Wong A, MacKinnon K, Weir K, Keeney M, Boyle E, Cruickshank M (1994) Assessment of the validity of the INR system for patients with liver impairment. Thromb Hemost 71:727–730 Kovacs MJ, Wong A, MacKinnon K, Weir K, Keeney M, Boyle E, Cruickshank M (1994) Assessment of the validity of the INR system for patients with liver impairment. Thromb Hemost 71:727–730
4.
go back to reference Denson KW, Reed SV, Haddon ME, Woodhams B, Brucato C, Ruiz J (1999) Comparative studies of rabbit and human recombinant tissue factor reagents. Thromb Res 94:255–261CrossRefPubMed Denson KW, Reed SV, Haddon ME, Woodhams B, Brucato C, Ruiz J (1999) Comparative studies of rabbit and human recombinant tissue factor reagents. Thromb Res 94:255–261CrossRefPubMed
5.
go back to reference Tripodi A, Chantarangkul V, Primignani M, Fabris F, Dell’Era A, Sei C, Mannucci PM (2007) The international normalized ratio calibrated for cirrhosis (INRliver) normalizes prothrombin time results for model for end-stage liver disease calculation. Hepatology 46:520–527CrossRefPubMed Tripodi A, Chantarangkul V, Primignani M, Fabris F, Dell’Era A, Sei C, Mannucci PM (2007) The international normalized ratio calibrated for cirrhosis (INRliver) normalizes prothrombin time results for model for end-stage liver disease calculation. Hepatology 46:520–527CrossRefPubMed
6.
go back to reference Bellest L, Eschwege V, Poupon R, Chazouillères O, Robert A (2007) A modified international normalized ratio as an effective way of prothrombin time standardization in hepatology. Hepatology 46:528–534CrossRefPubMed Bellest L, Eschwege V, Poupon R, Chazouillères O, Robert A (2007) A modified international normalized ratio as an effective way of prothrombin time standardization in hepatology. Hepatology 46:528–534CrossRefPubMed
7.
go back to reference Sermon AM, Smith JM, Maclean R, Kitchen S (2010) INR in liver disease: an ISI derived from liver disease patients improves agreement between INRs with different reagents. Thromb Haemost 103:757–765PubMed Sermon AM, Smith JM, Maclean R, Kitchen S (2010) INR in liver disease: an ISI derived from liver disease patients improves agreement between INRs with different reagents. Thromb Haemost 103:757–765PubMed
8.
go back to reference Tripodi A, Chantarangkul V, Primignani M, Dell’Era A, Clerici M, Iannuzzi F, Aghemo A, Cazzaniga M, Salerno F, Mannucci PM (2009) Point-of-care coagulation monitors calibrated for the international normalized ratio for cirrhosis (INRliver) can help to implement the INRliver for the calculation of the MELD score. J Hepatol 51:288–295CrossRefPubMed Tripodi A, Chantarangkul V, Primignani M, Dell’Era A, Clerici M, Iannuzzi F, Aghemo A, Cazzaniga M, Salerno F, Mannucci PM (2009) Point-of-care coagulation monitors calibrated for the international normalized ratio for cirrhosis (INRliver) can help to implement the INRliver for the calculation of the MELD score. J Hepatol 51:288–295CrossRefPubMed
9.
go back to reference Tripodi A, Chantarangkul V, Mannucci PM (2008) The international normalized ratio to prioritize patients for liver transplantation. Problems and possible solutions. J Thromb Haemost 6:243–248PubMed Tripodi A, Chantarangkul V, Mannucci PM (2008) The international normalized ratio to prioritize patients for liver transplantation. Problems and possible solutions. J Thromb Haemost 6:243–248PubMed
10.
go back to reference Tripodi A, Baglin T, Robert A, Kitchen S, Lisman T, Trotter JF, on behalf of the Subcommittee on Control of Anticoagulation of the Scientific and Standardisation Committee of the International Society on Thrombosis and Haemostasis (2010) Reporting prothrombin time results as international normalised ratios for patients with chronic liver disease. J Thromb Haemost 8:1410–1412 Tripodi A, Baglin T, Robert A, Kitchen S, Lisman T, Trotter JF, on behalf of the Subcommittee on Control of Anticoagulation of the Scientific and Standardisation Committee of the International Society on Thrombosis and Haemostasis (2010) Reporting prothrombin time results as international normalised ratios for patients with chronic liver disease. J Thromb Haemost 8:1410–1412
11.
go back to reference Porte RG, Lisman T, Tripodi A, Caldwell SH, Trotter JF, and the Coagulation in Liver Disease Study Group (2010) The international normalized ratio (INR) in the MELD score: problems and solutions. Am J Transplant 10:1349–1353CrossRefPubMed Porte RG, Lisman T, Tripodi A, Caldwell SH, Trotter JF, and the Coagulation in Liver Disease Study Group (2010) The international normalized ratio (INR) in the MELD score: problems and solutions. Am J Transplant 10:1349–1353CrossRefPubMed
Metadata
Title
The validity of the INR system for patients with liver disease
Author
Armando Tripodi
Publication date
01-02-2011
Publisher
Springer US
Published in
Journal of Thrombosis and Thrombolysis / Issue 2/2011
Print ISSN: 0929-5305
Electronic ISSN: 1573-742X
DOI
https://doi.org/10.1007/s11239-010-0508-y

Other articles of this Issue 2/2011

Journal of Thrombosis and Thrombolysis 2/2011 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.