Abstract

It is important to visually confirm radiofrequency ablation lesions during atrial fibrillation (AF) ablation for procedural efficiency, which requires the integration of a three-dimensional (3D) left atrial image reconstructed from computed tomography (CT) or a magnetic resonance imaging. However, an EP Navigator allows seamless integration of 3D anatomy obtained through 3D rotational angiography (3D-ATG) into an electroanatomical mapping system. We hypothesized that 3D-ATG can be used during AF ablation while significantly reducing the effective dose (ED) and without compromising image morphology compared to a 3D-CT image. Organ dose was measured at 37 points with a radiophotoluminescence glass dosimeter inserted in an anthropomorphic Rando Phantom. The ED was calculated by multiplying the organ dose by the tissue weighting factor. The dose-area product (DAP)-to-ED conversion factor was calculated by measuring the DAP during radiation exposure. The ED for the CT examination was estimated from the dose-length product with a conversion factor of 0.014. ED was calculated from DAP measurements in 114 patients undergoing AF ablation using 3D-ATG. The DAP-to-ED conversion factor for 3D-ATG was 2.4 × 10−4 mSv/mGy cm2 in our hospital. The mean DAP for all patients was 7777 ± 1488 mGy cm2 for the 3D-ATG of the left atrium. The corresponding ED for 3D-ATG was 1.9 ± 0.4 mSv. The ED for CT examinations was 13.6 ± 4.2 mSv (P < 0.001). 3D-ATG can be used during AF ablation while significantly reducing the ED and without compromising image morphology.
Literature
1.
go back to reference Mikaelian BJ, Malchano ZJ, Neuzil P, Weichet J, Doshi SK, Ruskin JN, Reddy VY (2005) Images in cardiovascular medicine. Integration of 3-dimensional cardiac computed tomography images with real-time electroanatomic mapping to guide catheter ablation of atrial fibrillation. Circulation 112:e35–e36CrossRef Mikaelian BJ, Malchano ZJ, Neuzil P, Weichet J, Doshi SK, Ruskin JN, Reddy VY (2005) Images in cardiovascular medicine. Integration of 3-dimensional cardiac computed tomography images with real-time electroanatomic mapping to guide catheter ablation of atrial fibrillation. Circulation 112:e35–e36CrossRef
2.
go back to reference Noseworthy PA, Malchano ZJ, Ahmed J, Holmvang G, Ruskin JN, Reddy VY (2005) The impact of respiration on left atrial and pulmonary venous anatomy: implications for image-guided intervention. Heart Rhythm 2:1173–1178CrossRef Noseworthy PA, Malchano ZJ, Ahmed J, Holmvang G, Ruskin JN, Reddy VY (2005) The impact of respiration on left atrial and pulmonary venous anatomy: implications for image-guided intervention. Heart Rhythm 2:1173–1178CrossRef
3.
go back to reference Dong J, Calkins H, Solomon SB, Lai S, Dalal D, Lardo AC, Brem E, Preiss A, Berger RD, Halperin H, Dickfeld T (2006) Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations. Circulation 113:186–194CrossRef Dong J, Calkins H, Solomon SB, Lai S, Dalal D, Lardo AC, Brem E, Preiss A, Berger RD, Halperin H, Dickfeld T (2006) Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations. Circulation 113:186–194CrossRef
4.
go back to reference Kistler PM, Earley MJ, Harris S, Abrams D, Ellis S, Sporton SC, Schilling RJ (2006) Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17:341–348CrossRef Kistler PM, Earley MJ, Harris S, Abrams D, Ellis S, Sporton SC, Schilling RJ (2006) Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17:341–348CrossRef
5.
go back to reference Li JH, Haim M, Movassaghi B, Mendel JB, Chaudhry GM, Haffajee CI, Orlov MV (2009) Segmentation and registration of three-dimensional rotational angiogram on live fluoroscopy to guide atrial fibrillation ablation: a new online imaging tool. Heart Rhythm 6:231–237CrossRef Li JH, Haim M, Movassaghi B, Mendel JB, Chaudhry GM, Haffajee CI, Orlov MV (2009) Segmentation and registration of three-dimensional rotational angiogram on live fluoroscopy to guide atrial fibrillation ablation: a new online imaging tool. Heart Rhythm 6:231–237CrossRef
6.
go back to reference Tang M, Kriatselis C, Ye G, Nedios S, Roser M, Solowjowa N, Fleck E, Gerds-Li JH (2009) Reconstructing and registering three-dimensional rotational angiogram of left atrium during ablation of atrial fibrillation. Pacing Clin Electrophysiol 32:1407–1416CrossRef Tang M, Kriatselis C, Ye G, Nedios S, Roser M, Solowjowa N, Fleck E, Gerds-Li JH (2009) Reconstructing and registering three-dimensional rotational angiogram of left atrium during ablation of atrial fibrillation. Pacing Clin Electrophysiol 32:1407–1416CrossRef
7.
go back to reference Kriatselis C, Nedios S, Akrivakis S, Tang M, Roser M, Gerds-Li JH, Fleck E, Orlov M (2011) Intraprocedural imaging of left atrium and pulmonary veins: a comparison study between rotational angiography and cardiac computed tomography. Pacing Clin Electrophysiol 34:315–322CrossRef Kriatselis C, Nedios S, Akrivakis S, Tang M, Roser M, Gerds-Li JH, Fleck E, Orlov M (2011) Intraprocedural imaging of left atrium and pulmonary veins: a comparison study between rotational angiography and cardiac computed tomography. Pacing Clin Electrophysiol 34:315–322CrossRef
8.
go back to reference Knecht S, Skali H, O’Neill MD, Wright M, Matsuo S, Chaudhry GM, Haffajee CI, Nault I, Gijsbers GH, Sacher F, Laurent F, Montaudon M, Corneloup O, Hocini M, Haïssaguerre M, Orlov MV, Jaïs P (2008) Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia. Europace 10:931–938CrossRef Knecht S, Skali H, O’Neill MD, Wright M, Matsuo S, Chaudhry GM, Haffajee CI, Nault I, Gijsbers GH, Sacher F, Laurent F, Montaudon M, Corneloup O, Hocini M, Haïssaguerre M, Orlov MV, Jaïs P (2008) Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia. Europace 10:931–938CrossRef
9.
go back to reference Hurwitz LM, Yoshizumi TT, Goodman PC, Frush DP, Nguyen G, Toncheva G, Lowry C (2007) Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomog 31:544–549CrossRef Hurwitz LM, Yoshizumi TT, Goodman PC, Frush DP, Nguyen G, Toncheva G, Lowry C (2007) Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomog 31:544–549CrossRef
10.
go back to reference [No authors listed] (2007) The 2007 Recommendations of the international commission on radiological protection ICRP publication 103. Ann ICRP 37:1–332 [No authors listed] (2007) The 2007 Recommendations of the international commission on radiological protection ICRP publication 103. Ann ICRP 37:1–332
11.
go back to reference Ejima K, Shoda M, Yagishita D, Futagawa K, Yashiro B, Sato T, Manaka T, Nakajima T, Ohmori H, Hagiwara N (2010) Image integration of three-dimensional cone-beam computed tomography angiogram into electroanatomical mapping system to guide catheter ablation of atrial fibrillation. Europace 12:45–51CrossRef Ejima K, Shoda M, Yagishita D, Futagawa K, Yashiro B, Sato T, Manaka T, Nakajima T, Ohmori H, Hagiwara N (2010) Image integration of three-dimensional cone-beam computed tomography angiogram into electroanatomical mapping system to guide catheter ablation of atrial fibrillation. Europace 12:45–51CrossRef
12.
go back to reference Nölker G, Gutleben KJ, Asbach S, Vogt J, Heintze J, Brachmann J, Horstkotte D, Sinha AM (2011) Intracardiac echocardiography for registration of rotational angiography-based left atrial reconstructions: a novel approach integrating two intraprocedural three-dimensional imaging techniques in atrial fibrillation ablation. Europace 13:492–498CrossRef Nölker G, Gutleben KJ, Asbach S, Vogt J, Heintze J, Brachmann J, Horstkotte D, Sinha AM (2011) Intracardiac echocardiography for registration of rotational angiography-based left atrial reconstructions: a novel approach integrating two intraprocedural three-dimensional imaging techniques in atrial fibrillation ablation. Europace 13:492–498CrossRef
13.
go back to reference Tan SK, Yeong CH, Ng KH, Abdul Aziz YF, Sun Z (2016) Recent update on radiation dose assessment for the state-of-the-art coronary computed tomography angiography protocols. PLoS One 11:e0161543CrossRef Tan SK, Yeong CH, Ng KH, Abdul Aziz YF, Sun Z (2016) Recent update on radiation dose assessment for the state-of-the-art coronary computed tomography angiography protocols. PLoS One 11:e0161543CrossRef
14.
go back to reference Vano E, Gonzalez L, Ten JL, Fernandez JM, Guibelalde E, Macaya C (2001) Skin dose and dose-area product values for interventional cardiology procedures. Br J Radiol 74:48–55CrossRef Vano E, Gonzalez L, Ten JL, Fernandez JM, Guibelalde E, Macaya C (2001) Skin dose and dose-area product values for interventional cardiology procedures. Br J Radiol 74:48–55CrossRef
15.
go back to reference Delichas MG, Psarrakos K, Molyvda-Athanassopoulou E, Giannoglou G, Hatziioannou K, Papanastassiou E (2003) Radiation doses to patients undergoing coronary angiography and percutaneous transluminal coronary angioplasty. Radiat Prot Dosim 103:149–154CrossRef Delichas MG, Psarrakos K, Molyvda-Athanassopoulou E, Giannoglou G, Hatziioannou K, Papanastassiou E (2003) Radiation doses to patients undergoing coronary angiography and percutaneous transluminal coronary angioplasty. Radiat Prot Dosim 103:149–154CrossRef
16.
go back to reference Stisova V (2004) Effective dose to patient during cardiac interventional procedures (prague workplaces). Radiat Prot Dosim 111:271–274CrossRef Stisova V (2004) Effective dose to patient during cardiac interventional procedures (prague workplaces). Radiat Prot Dosim 111:271–274CrossRef
17.
go back to reference Bor D, Sancak T, Olgar T, Elcim Y, Adanali A, Sanlidilek U, Akyar S (2004) Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology. Br J Radiol 77:315–322CrossRef Bor D, Sancak T, Olgar T, Elcim Y, Adanali A, Sanlidilek U, Akyar S (2004) Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology. Br J Radiol 77:315–322CrossRef
18.
go back to reference Anand Rishi, Gorev Maxim V, Poghosyan Hermine, Pothier Lindsay, Matkins John, Kotler Gregory, Moroz Sarah, Armstrong James, Nemtsov Sergei V, Orlov Michael V (2016) Prospective randomized comparison of rotational angiography with three-dimensional reconstruction and computed tomography merged with electro-anatomical mapping: a two center atrial fibrillation ablation study. J Interv Card Electrophysiol 46:71–79CrossRef Anand Rishi, Gorev Maxim V, Poghosyan Hermine, Pothier Lindsay, Matkins John, Kotler Gregory, Moroz Sarah, Armstrong James, Nemtsov Sergei V, Orlov Michael V (2016) Prospective randomized comparison of rotational angiography with three-dimensional reconstruction and computed tomography merged with electro-anatomical mapping: a two center atrial fibrillation ablation study. J Interv Card Electrophysiol 46:71–79CrossRef
19.
go back to reference Kriatselis C, Nedios S, Akrivakis S, Tang M, Roser M, Gerds-Li JH, Fleck E, Orlov M (2011) Intraprocedural imaging of left atrium and pulmonary veins: a comparison study between rotational angiography and cardiac computed tomography. Pacing Clin Electrophysiol 34:315–322CrossRef Kriatselis C, Nedios S, Akrivakis S, Tang M, Roser M, Gerds-Li JH, Fleck E, Orlov M (2011) Intraprocedural imaging of left atrium and pulmonary veins: a comparison study between rotational angiography and cardiac computed tomography. Pacing Clin Electrophysiol 34:315–322CrossRef
20.
go back to reference Li JH, Haim M, Movassaghi B, Mendel JB, Chaudhry GM, Haffajee CI, Orlov MV (2009) Segmentation and registration of three-dimensional rotational angiogram on live fluoroscopy to guide atrial fibrillation ablation: a new online imaging tool. Heart Rhythm 6:231–237CrossRef Li JH, Haim M, Movassaghi B, Mendel JB, Chaudhry GM, Haffajee CI, Orlov MV (2009) Segmentation and registration of three-dimensional rotational angiogram on live fluoroscopy to guide atrial fibrillation ablation: a new online imaging tool. Heart Rhythm 6:231–237CrossRef
21.
go back to reference Nahass GT (1995) Fluoroscopy and the skin: implications for radiofrequency catheter ablation. Am J Cardiol 76:174–176CrossRef Nahass GT (1995) Fluoroscopy and the skin: implications for radiofrequency catheter ablation. Am J Cardiol 76:174–176CrossRef
22.
go back to reference Perisinakis K, Damilakis J, Theocharopoulos N, Manios E, Vardas P, Gourtsoyiannis N (2001) Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures. Circulation 104:58–62CrossRef Perisinakis K, Damilakis J, Theocharopoulos N, Manios E, Vardas P, Gourtsoyiannis N (2001) Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures. Circulation 104:58–62CrossRef
23.
go back to reference JCS Joint Working Group (2010) Guideline for radiation safety in interventional cardiology (JCS 2011)—digest version. Circ J 74:2760–2785CrossRef JCS Joint Working Group (2010) Guideline for radiation safety in interventional cardiology (JCS 2011)—digest version. Circ J 74:2760–2785CrossRef
24.
go back to reference Hur Jin, Kim YJ, Lee HJ, Nam JE, Ha JW, Heo JH, Chang HJ, Kim HS, Hong YJ, Kim HY, Choe KO, Choi BW (2011) Dual-enhanced cardiac CT for detection of left atrial appendage thrombus in patients with stroke. A prospective comparison study with transesophageal echocardiography. Stroke 42:2471–2477CrossRef Hur Jin, Kim YJ, Lee HJ, Nam JE, Ha JW, Heo JH, Chang HJ, Kim HS, Hong YJ, Kim HY, Choe KO, Choi BW (2011) Dual-enhanced cardiac CT for detection of left atrial appendage thrombus in patients with stroke. A prospective comparison study with transesophageal echocardiography. Stroke 42:2471–2477CrossRef
Metadata
Title
The seamless integration of three-dimensional rotational angiography images into electroanatomical mapping systems to guide catheter ablation of atrial fibrillation
Authors
Satoshi Fujita
Eitaro Fujii
Yoshihiko Kagawa
Katsuhiro Inoue
Tsuyoshi Yamada
Masaaki Ito
Publication date
01-11-2018
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 11/2018
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-018-1180-y

Other articles of this Issue 11/2018

Heart and Vessels 11/2018 Go to the issue