Skip to main content
Top
Published in: Lung 5/2010

01-10-2010

The Impact of Pulmonary Disease on Noninvasive Measurement of Cardiac Output by the Inert Gas Rebreathing Method

Authors: Joachim Saur, Frederik Trinkmann, Christina Doesch, Armin Scherhag, Joachim Brade, Stefan O. Schoenberg, Martin Borggrefe, Jens J. Kaden, Theano Papavassiliu

Published in: Lung | Issue 5/2010

Login to get access

Abstract

Cardiac output (CO) is an important parameter for diagnosis and therapy of heart diseases, but it is still difficult to determine. Innocor, a novel noninvasive inert gas rebreathing (IGR) system, has shown promising results. However, the impact of pulmonary diseases on IGR remains unclear. The aim of the study therefore was to assess the accuracy and reliability of IGR in patients with distinct chronic lung disease. A total of 96 patients were enrolled, including 48 consecutive patients with variant lung diseases (group A) and 48 pair-matched pulmonary healthy patients (group B). CO was measured with cardiac magnetic resonance imaging (CMR) and IGR. Lung function testing was done by spirometry [FEV1/FVC (forced expiratory volume in one second/forced vital capacity), VC (vital capacity)] and determination of the diffusing capacity of the lung for carbon monoxide divided by alveolar volume (DLCO/VA). In group A we found a mean CO of 4.7 ± 1.3 L/min by IGR and 4.9 ± 1.2 L/min by CMR. Group B showed a mean CO of 4.8 ± 1.4 L/min by IGR and 5.0 ± 1.3 L/min by CMR. Bland–Altman analysis revealed good correspondence between CMR and IGR, with an average deviation of 0.1 ± 1.0 L/min in group A and 0.1 ± 1.0 L/min in group B (p = 0.99). Multiple regression analysis for the pulmonary parameters did not show a statistically significant impact on the mean bias of CO measurements (FEV1/FVC: r = 0.01, p = 0.91; VC: r = −0.2, p = 0.13; and DLCO/VA: r = 0.04, p = 0.82). IGR allows a feasible determination of CO even in patients with lung diseases. The accuracy of the IGR method is not influenced by either pulmonary obstructive and restrictive diseases or a reduced DLCO.
Literature
1.
go back to reference Clemensen P, Christensen P, Norsk P, Gronlund J (1994) A modified photo- and magnetoacoustic multigas analyzer applied in gas exchange measurements. J Appl Physiol 76:2832–2839PubMed Clemensen P, Christensen P, Norsk P, Gronlund J (1994) A modified photo- and magnetoacoustic multigas analyzer applied in gas exchange measurements. J Appl Physiol 76:2832–2839PubMed
2.
go back to reference Agostoni P, Cattadori G, Apostolo A, Contini M, Palermo P, Marenzi G, Wasserman K (2005) Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation. J Am Coll Cardiol 46:1779–1781CrossRefPubMed Agostoni P, Cattadori G, Apostolo A, Contini M, Palermo P, Marenzi G, Wasserman K (2005) Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation. J Am Coll Cardiol 46:1779–1781CrossRefPubMed
3.
go back to reference Dong L, Wang JA, Jiang CY (2005) Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients. J Zhejiang Univ Sci B 6:1157–1162CrossRefPubMed Dong L, Wang JA, Jiang CY (2005) Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients. J Zhejiang Univ Sci B 6:1157–1162CrossRefPubMed
4.
go back to reference Reutershan J, Kapp T, Unertl K, Fretschner R (2003) Noninvasive determination of cardiac output in ventilated patients. Clinical evaluation of a simplified quick method. Anaesthesist 52:778–786CrossRefPubMed Reutershan J, Kapp T, Unertl K, Fretschner R (2003) Noninvasive determination of cardiac output in ventilated patients. Clinical evaluation of a simplified quick method. Anaesthesist 52:778–786CrossRefPubMed
5.
go back to reference Christensen P, Clemensen P, Andersen PK, Henneberg SW (2000) Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow. Crit Care Med 28:51–56CrossRefPubMed Christensen P, Clemensen P, Andersen PK, Henneberg SW (2000) Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow. Crit Care Med 28:51–56CrossRefPubMed
6.
go back to reference Gabrielsen A, Videbaek R, Schou M, Damgaard M, Kastrup J, Norsk P (2002) Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique. Clin Sci (Lond) 102:247–252CrossRef Gabrielsen A, Videbaek R, Schou M, Damgaard M, Kastrup J, Norsk P (2002) Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique. Clin Sci (Lond) 102:247–252CrossRef
7.
go back to reference Saur J, Fluechter S, Trinkmann F, Papavassiliu T, Schoenberg S, Weissmann J, Haghi D, Borggrefe M, Kaden JJ (2009) Noninvasive determination of cardiac output by the inert-gas-rebreathing method—comparison with cardiovascular magnetic resonance imaging. Cardiology 114:247–254CrossRefPubMed Saur J, Fluechter S, Trinkmann F, Papavassiliu T, Schoenberg S, Weissmann J, Haghi D, Borggrefe M, Kaden JJ (2009) Noninvasive determination of cardiac output by the inert-gas-rebreathing method—comparison with cardiovascular magnetic resonance imaging. Cardiology 114:247–254CrossRefPubMed
8.
go back to reference Agostoni P, Cattadori G (2009) Noninvasive cardiac output measurement: a new tool in heart failure. Cardiology 114:244–246CrossRefPubMed Agostoni P, Cattadori G (2009) Noninvasive cardiac output measurement: a new tool in heart failure. Cardiology 114:244–246CrossRefPubMed
9.
go back to reference Saur J, Trinkmann F, Doesch C, Weissmann J, Hamm K, Schoenberg S, Borggrefe M, Haghi D, Kaden J (2010) Non-invasive measurement of cardiac output during atrial fibrillation—comparison of cardiac magnetic resonance imaging and inert gas rebreathing. Cardiology 115:212–216CrossRefPubMed Saur J, Trinkmann F, Doesch C, Weissmann J, Hamm K, Schoenberg S, Borggrefe M, Haghi D, Kaden J (2010) Non-invasive measurement of cardiac output during atrial fibrillation—comparison of cardiac magnetic resonance imaging and inert gas rebreathing. Cardiology 115:212–216CrossRefPubMed
10.
go back to reference Damgaard M, Norsk P (2005) Effects of ventilation on cardiac output determined by inert gas rebreathing. Clin Physiol Funct Imaging 25:142–147CrossRefPubMed Damgaard M, Norsk P (2005) Effects of ventilation on cardiac output determined by inert gas rebreathing. Clin Physiol Funct Imaging 25:142–147CrossRefPubMed
11.
go back to reference Papavassiliu T, Kuhl HP, Schroder M, Suselbeck T, Bondarenko O, Bohm CK, Beek A, Hofman MM, van Rossum AC (2005) Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology 236:57–64CrossRefPubMed Papavassiliu T, Kuhl HP, Schroder M, Suselbeck T, Bondarenko O, Bohm CK, Beek A, Hofman MM, van Rossum AC (2005) Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology 236:57–64CrossRefPubMed
12.
go back to reference MacIntyre N, Crapo RO, Viegi G, Johnson DC, van der Grinten CP, Brusasco V, Burgos F, Casaburi R, Coates A, Enright P, Gustafsson P, Hankinson J, Jensen R, McKay R, Miller MR, Navajas D, Pedersen OF, Pellegrino R, Wanger J (2005) Standardisation of the single-breath determination of carbon monoxide uptake in the lung. Eur Respir J 26:720–735CrossRefPubMed MacIntyre N, Crapo RO, Viegi G, Johnson DC, van der Grinten CP, Brusasco V, Burgos F, Casaburi R, Coates A, Enright P, Gustafsson P, Hankinson J, Jensen R, McKay R, Miller MR, Navajas D, Pedersen OF, Pellegrino R, Wanger J (2005) Standardisation of the single-breath determination of carbon monoxide uptake in the lung. Eur Respir J 26:720–735CrossRefPubMed
13.
go back to reference Dressel H, Filser L, Fischer R, de la Motte D, Steinhaeusser W, Huber RM, Nowak D, Jorres RA (2008) Lung diffusing capacity for nitric oxide and carbon monoxide: dependence on breath-hold time. Chest 133:1149–1154CrossRefPubMed Dressel H, Filser L, Fischer R, de la Motte D, Steinhaeusser W, Huber RM, Nowak D, Jorres RA (2008) Lung diffusing capacity for nitric oxide and carbon monoxide: dependence on breath-hold time. Chest 133:1149–1154CrossRefPubMed
14.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMed
15.
go back to reference Pellegrino R, Viegi G, Brusasco V, Crapo RO, Burgos F, Casaburi R, Coates A, van der Grinten CP, Gustafsson P, Hankinson J, Jensen R, Johnson DC, MacIntyre N, McKay R, Miller MR, Navajas D, Pedersen OF, Wanger J (2005) Interpretative strategies for lung function tests. Eur Respir J 26:948–968CrossRefPubMed Pellegrino R, Viegi G, Brusasco V, Crapo RO, Burgos F, Casaburi R, Coates A, van der Grinten CP, Gustafsson P, Hankinson J, Jensen R, Johnson DC, MacIntyre N, McKay R, Miller MR, Navajas D, Pedersen OF, Wanger J (2005) Interpretative strategies for lung function tests. Eur Respir J 26:948–968CrossRefPubMed
16.
go back to reference Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, Crapo R, Enright P, van der Grinten CP, Gustafsson P, Jensen R, Johnson DC, MacIntyre N, McKay R, Navajas D, Pedersen OF, Pellegrino R, Viegi G, Wanger J (2005) Standardisation of spirometry. Eur Respir J 26:319–338CrossRefPubMed Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, Crapo R, Enright P, van der Grinten CP, Gustafsson P, Jensen R, Johnson DC, MacIntyre N, McKay R, Navajas D, Pedersen OF, Pellegrino R, Viegi G, Wanger J (2005) Standardisation of spirometry. Eur Respir J 26:319–338CrossRefPubMed
17.
go back to reference Kaukinen S, Koobi T, Bi Y, Turjanmaa VM (2003) Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography. J Cardiothorac Vasc Anesth 17:199–203CrossRefPubMed Kaukinen S, Koobi T, Bi Y, Turjanmaa VM (2003) Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography. J Cardiothorac Vasc Anesth 17:199–203CrossRefPubMed
18.
go back to reference Van De Water JM, Miller TW, Vogel RL, Mount BE, Dalton ML (2003) Impedance cardiography: the next vital sign technology? Chest 123:2028–2033CrossRef Van De Water JM, Miller TW, Vogel RL, Mount BE, Dalton ML (2003) Impedance cardiography: the next vital sign technology? Chest 123:2028–2033CrossRef
19.
go back to reference Barbera JA, Peinado VI, Santos S (2003) Pulmonary hypertension in chronic obstructive pulmonary disease. Eur Respir J 21:892–905CrossRefPubMed Barbera JA, Peinado VI, Santos S (2003) Pulmonary hypertension in chronic obstructive pulmonary disease. Eur Respir J 21:892–905CrossRefPubMed
20.
go back to reference Ley-Zaporozhan J, Ley S, Eberhardt R, Weinheimer O, Fink C, Puderbach M, Eichinger M, Herth F, Kauczor HU (2007) Assessment of the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level in patients with emphysema. Eur J Radiol 63:76–83CrossRefPubMed Ley-Zaporozhan J, Ley S, Eberhardt R, Weinheimer O, Fink C, Puderbach M, Eichinger M, Herth F, Kauczor HU (2007) Assessment of the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level in patients with emphysema. Eur J Radiol 63:76–83CrossRefPubMed
21.
go back to reference Ohno Y, Hatabu H, Murase K, Higashino T, Kawamitsu H, Watanabe H, Takenaka D, Fujii M, Sugimura K (2004) Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: preliminary experience in 40 subjects. J Magn Reson Imaging 20:353–365CrossRefPubMed Ohno Y, Hatabu H, Murase K, Higashino T, Kawamitsu H, Watanabe H, Takenaka D, Fujii M, Sugimura K (2004) Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: preliminary experience in 40 subjects. J Magn Reson Imaging 20:353–365CrossRefPubMed
22.
go back to reference Cordasco EM, Beerel FR, Vance JW, Wende RW, Toffolo RR (1968) Newer aspects of the pulmonary vasculature in chronic lung disease. A comparative study. Angiology 19:399–407CrossRefPubMed Cordasco EM, Beerel FR, Vance JW, Wende RW, Toffolo RR (1968) Newer aspects of the pulmonary vasculature in chronic lung disease. A comparative study. Angiology 19:399–407CrossRefPubMed
23.
go back to reference Jang YM, Oh YM, Seo JB, Kim N, Chae EJ, Lee YK, Lee SD (2008) Quantitatively assessed dynamic contrast-enhanced magnetic resonance imaging in patients with chronic obstructive pulmonary disease: correlation of perfusion parameters with pulmonary function test and quantitative computed tomography. Invest Radiol 43:403–410CrossRefPubMed Jang YM, Oh YM, Seo JB, Kim N, Chae EJ, Lee YK, Lee SD (2008) Quantitatively assessed dynamic contrast-enhanced magnetic resonance imaging in patients with chronic obstructive pulmonary disease: correlation of perfusion parameters with pulmonary function test and quantitative computed tomography. Invest Radiol 43:403–410CrossRefPubMed
24.
go back to reference Petrini MF, Peterson BT, Hyde RW (1978) Lung tissue volume and blood flow by rebreathing theory. J Appl Physiol 44:795–802PubMed Petrini MF, Peterson BT, Hyde RW (1978) Lung tissue volume and blood flow by rebreathing theory. J Appl Physiol 44:795–802PubMed
25.
go back to reference Kallay MC, Hyde RW, Fahey PJ, Utell MJ, Peterson BT, Ortiz CR (1985) Effect of the rebreathing pattern on pulmonary tissue volume and capillary blood flow. J Appl Physiol 58:1881–1894PubMed Kallay MC, Hyde RW, Fahey PJ, Utell MJ, Peterson BT, Ortiz CR (1985) Effect of the rebreathing pattern on pulmonary tissue volume and capillary blood flow. J Appl Physiol 58:1881–1894PubMed
26.
go back to reference Kallay MC, Hyde RW, Smith RJ, Rothbard RL, Schreiner BF (1987) Cardiac output by rebreathing in patients with cardiopulmonary diseases. J Appl Physiol 63:201–210PubMed Kallay MC, Hyde RW, Smith RJ, Rothbard RL, Schreiner BF (1987) Cardiac output by rebreathing in patients with cardiopulmonary diseases. J Appl Physiol 63:201–210PubMed
27.
go back to reference Krug S, Hammerschmidt S, Pankau H, Wirtz H, Seyfarth HJ (2008) Acute improved hemodynamics following inhaled iloprost in chronic thromboembolic pulmonary hypertension. Respiration 76:154–159CrossRefPubMed Krug S, Hammerschmidt S, Pankau H, Wirtz H, Seyfarth HJ (2008) Acute improved hemodynamics following inhaled iloprost in chronic thromboembolic pulmonary hypertension. Respiration 76:154–159CrossRefPubMed
28.
go back to reference Stahlberg M, Damgaard M, Norsk P, Gabrielsen A, Sahlen A, Linde C, Braunschweig F (2009) Cardiac output response to changes of the atrioventricular delay in different body positions and during exercise in patients receiving cardiac resynchronization therapy. Europace 11:1160–1167CrossRefPubMed Stahlberg M, Damgaard M, Norsk P, Gabrielsen A, Sahlen A, Linde C, Braunschweig F (2009) Cardiac output response to changes of the atrioventricular delay in different body positions and during exercise in patients receiving cardiac resynchronization therapy. Europace 11:1160–1167CrossRefPubMed
29.
go back to reference Cattadori G, Schmid JP, Agostoni P (2009) Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique. Heart Fail Clin 5:209–215CrossRefPubMed Cattadori G, Schmid JP, Agostoni P (2009) Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique. Heart Fail Clin 5:209–215CrossRefPubMed
30.
go back to reference Fontana P, Boutellier U, Toigo M (2010) Non-invasive haemodynamic assessments using innocor during standard graded exercise tests. Eur J Appl Physiol 108:573–580CrossRefPubMed Fontana P, Boutellier U, Toigo M (2010) Non-invasive haemodynamic assessments using innocor during standard graded exercise tests. Eur J Appl Physiol 108:573–580CrossRefPubMed
31.
go back to reference Fontana P, Boutellier U, Toigo M (2009) Reliability of measurements with innocor during exercise. Int J Sports Med 30:747–753CrossRefPubMed Fontana P, Boutellier U, Toigo M (2009) Reliability of measurements with innocor during exercise. Int J Sports Med 30:747–753CrossRefPubMed
32.
go back to reference Guazzi M, Pontone G, Brambilla R, Agostoni P, Reina G (2002) Alveolar–capillary membrane gas conductance: a novel prognostic indicator in chronic heart failure. Eur Heart J 23:467–476CrossRefPubMed Guazzi M, Pontone G, Brambilla R, Agostoni P, Reina G (2002) Alveolar–capillary membrane gas conductance: a novel prognostic indicator in chronic heart failure. Eur Heart J 23:467–476CrossRefPubMed
33.
go back to reference Ferrazza AM, Martolini D, Valli G, Palange P (2009) Cardiopulmonary exercise testing in the functional and prognostic evaluation of patients with pulmonary diseases. Respiration 77:3–17CrossRefPubMed Ferrazza AM, Martolini D, Valli G, Palange P (2009) Cardiopulmonary exercise testing in the functional and prognostic evaluation of patients with pulmonary diseases. Respiration 77:3–17CrossRefPubMed
Metadata
Title
The Impact of Pulmonary Disease on Noninvasive Measurement of Cardiac Output by the Inert Gas Rebreathing Method
Authors
Joachim Saur
Frederik Trinkmann
Christina Doesch
Armin Scherhag
Joachim Brade
Stefan O. Schoenberg
Martin Borggrefe
Jens J. Kaden
Theano Papavassiliu
Publication date
01-10-2010
Publisher
Springer-Verlag
Published in
Lung / Issue 5/2010
Print ISSN: 0341-2040
Electronic ISSN: 1432-1750
DOI
https://doi.org/10.1007/s00408-010-9257-0

Other articles of this Issue 5/2010

Lung 5/2010 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.