Skip to main content
Top
Published in: European Radiology 8/2004

01-08-2004 | Experimental

The effect of varying low-dose protocols on perceived image quality in multidetector CT in a rabbit model of acute appendicitis

Authors: Marcus Hörmann, Marcel O. Philipp, Heidrun Eberl, Ursula Windberger, Wolfgang Matzek, Cornelia Schäfer-Prokop, Viktor M. Metz

Published in: European Radiology | Issue 8/2004

Login to get access

Abstract

The aim of this study was to evaluate the value of multidetector CT (MD-CT) with low-dose protocols in the diagnosis of acute appendicitis in a rabbit model. Ten New Zealand white rabbits underwent ligation of the appendix. MD-CT (Siemens Somatom Plus 4 Volume Zoom) was performed using three low-dose protocols: 80 kV/70 mAs; 80 kV/50 mAs; and 80 kV/20 mAs. Axial and coronal reformations were performed. Three experienced radiologists evaluated the images using a four-grade score: (1) excellent; (2) good; (3) moderate; and (4) not sufficient. Diagnosis was confirmed histopathologically. The overall score for the 80 kV/70 mAs was 1, for the 80 kV/50 mAs protocol 1.3, and the 80 kV/20 mAs protocol reached an overall score of 2. The coronal reformations reached with 1.1 (80 kV/70 mAs), 1.2 (80 kV/50 mAs), and 1.4 (80 kV/20 mAs) had a slightly better median score than the axial reconstructions. In cases of inconclusive ultrasound and clinical presentation, the use of MD-CT can be considered when evaluating children for suspected appendicitis.
Literature
1.
go back to reference Curtin KR, Fitzgerald SW, Nemcek AA, Hoff FL, Vogelzang RL (1995) CT diagnosis of acute appendicitis: imaging findings. Am J Roentgenol 164:905–909 Curtin KR, Fitzgerald SW, Nemcek AA, Hoff FL, Vogelzang RL (1995) CT diagnosis of acute appendicitis: imaging findings. Am J Roentgenol 164:905–909
2.
go back to reference Balthazar EJ, Birnbaum BA, Yee J, Megibow AJ, Roshkow J, Gray C (1984) Acute appendicitis: CT and US correlation in 100 patients. Radiology 190:31–35 Balthazar EJ, Birnbaum BA, Yee J, Megibow AJ, Roshkow J, Gray C (1984) Acute appendicitis: CT and US correlation in 100 patients. Radiology 190:31–35
3.
go back to reference Berry J Jr, Malt RA (1984) Appendicitis near its centenary. Ann Surg 200:567–575PubMed Berry J Jr, Malt RA (1984) Appendicitis near its centenary. Ann Surg 200:567–575PubMed
4.
go back to reference Puig S, Hörmann M, Rebhandl W, Felder-Puig R, Prokop M, Paya K (2003) US as a primary diagnostic tool in relation to negative appendectomie: 6 years experience. Radiology 226:101–104PubMed Puig S, Hörmann M, Rebhandl W, Felder-Puig R, Prokop M, Paya K (2003) US as a primary diagnostic tool in relation to negative appendectomie: 6 years experience. Radiology 226:101–104PubMed
5.
go back to reference Karakas SP, Guelfguat M, Leonidas JC, Springer S, Singh SP (2000) Acute appendicitis in children: comparison of clinical diagnosis with ultrasound and CT imaging. Pediatr Radiol 30:94–98CrossRefPubMed Karakas SP, Guelfguat M, Leonidas JC, Springer S, Singh SP (2000) Acute appendicitis in children: comparison of clinical diagnosis with ultrasound and CT imaging. Pediatr Radiol 30:94–98CrossRefPubMed
6.
go back to reference Birnbaum BA, Jeffrey RB Jr (1998) CT and sonographic evaluation of acute right lower quadrant pain. Am J Roentgenol 170:361–371PubMed Birnbaum BA, Jeffrey RB Jr (1998) CT and sonographic evaluation of acute right lower quadrant pain. Am J Roentgenol 170:361–371PubMed
7.
go back to reference van Breda Vriesman AC, Kole BJ, Puylaert JB (2003) Effect of ultrasonography and optional computed tomography on the outcome of appendectomy. Eur Radiol 13:2278–2282CrossRefPubMed van Breda Vriesman AC, Kole BJ, Puylaert JB (2003) Effect of ultrasonography and optional computed tomography on the outcome of appendectomy. Eur Radiol 13:2278–2282CrossRefPubMed
8.
go back to reference Inescu L, Coskun A, Selcuk MB, Akan H, Sozubir S, Bernay F (1997) Acute appendicitis: MR imaging and sonographic correlation. Am J Roentgenol 168:669–674PubMed Inescu L, Coskun A, Selcuk MB, Akan H, Sozubir S, Bernay F (1997) Acute appendicitis: MR imaging and sonographic correlation. Am J Roentgenol 168:669–674PubMed
9.
go back to reference Puylaert JB (1986) Acute appendicitis: US evaluation using graded compression. Radiology 158:355–360PubMed Puylaert JB (1986) Acute appendicitis: US evaluation using graded compression. Radiology 158:355–360PubMed
10.
go back to reference Jeffrey RB Jr, Laing FC, Lewis FR (1987) Acute appendicitis: high-resolution real-time US findings. Radiology 163:11–14PubMed Jeffrey RB Jr, Laing FC, Lewis FR (1987) Acute appendicitis: high-resolution real-time US findings. Radiology 163:11–14PubMed
11.
go back to reference Sivit CJ, Newman KD, Boenning DA et al (1992) Appendicitis: usefulness of US in diagnosis in a pediatric population. Radiology 185:549–552PubMed Sivit CJ, Newman KD, Boenning DA et al (1992) Appendicitis: usefulness of US in diagnosis in a pediatric population. Radiology 185:549–552PubMed
12.
go back to reference Quillin SP, Siegel MJ, Coffin CM (1992) Acute appendicitis in children: value of sonography in detecting perforation. Am J Roentgenol 159:1265–1268 Quillin SP, Siegel MJ, Coffin CM (1992) Acute appendicitis in children: value of sonography in detecting perforation. Am J Roentgenol 159:1265–1268
13.
go back to reference Rao PM, Rhea JT, Novelline RA et al (1997) Helical CT technique for the diagnosis of appendicitis: prospective evaluation of a focused appendix CT examination. Radiology 202:139–1444PubMed Rao PM, Rhea JT, Novelline RA et al (1997) Helical CT technique for the diagnosis of appendicitis: prospective evaluation of a focused appendix CT examination. Radiology 202:139–1444PubMed
14.
go back to reference Malone AJ, Wolf CR, Malmed AS, Melliere B (1993) Diagnosis of acute appendicitis: value of unenhanced CT. Am J Roentgenol 160:763–766PubMed Malone AJ, Wolf CR, Malmed AS, Melliere B (1993) Diagnosis of acute appendicitis: value of unenhanced CT. Am J Roentgenol 160:763–766PubMed
15.
go back to reference Nakhgevany KB, Clarke LE (1986) Acute appendicitis in women of childbearing age. Arch Surg 121:1053–1056PubMed Nakhgevany KB, Clarke LE (1986) Acute appendicitis in women of childbearing age. Arch Surg 121:1053–1056PubMed
16.
go back to reference Frush DP, Slack CC, Hollingsworth CL, Bisset GS, Donnelly LF, Hsieh J, Lavin-Wensell T, Mayo JR (2002) Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. Am J Roentgenol 179:1107–1113 Frush DP, Slack CC, Hollingsworth CL, Bisset GS, Donnelly LF, Hsieh J, Lavin-Wensell T, Mayo JR (2002) Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. Am J Roentgenol 179:1107–1113
18.
go back to reference Morgan H, Braunstein D (2001) A computed tomography dose index for infants and young children. Med Phys 28:1818 Morgan H, Braunstein D (2001) A computed tomography dose index for infants and young children. Med Phys 28:1818
19.
go back to reference Berland LL, Smith JK (1998) Multidetector-array CT: once again, technology creates new opportunities. Radiology 209:327–329PubMed Berland LL, Smith JK (1998) Multidetector-array CT: once again, technology creates new opportunities. Radiology 209:327–329PubMed
20.
go back to reference Brix G, Nagel HD, Stamm G, Veit R, Lechel U, Griebel J, Galanski M (2003) Radiation exposure in multislice versus single-slice spiral CT: results of a nationwide survey. Eur Radiol 13:1979–1991CrossRefPubMed Brix G, Nagel HD, Stamm G, Veit R, Lechel U, Griebel J, Galanski M (2003) Radiation exposure in multislice versus single-slice spiral CT: results of a nationwide survey. Eur Radiol 13:1979–1991CrossRefPubMed
21.
go back to reference Wormanns D, Diederich S, Lenzen H, Lange P, Link TM, Ludwig K, Papke K, Hagedorn C, Heindel W (2001) Abdominal spiral CT in children: which radiation dose is required? Eur Radiol 11:2262–2266PubMed Wormanns D, Diederich S, Lenzen H, Lange P, Link TM, Ludwig K, Papke K, Hagedorn C, Heindel W (2001) Abdominal spiral CT in children: which radiation dose is required? Eur Radiol 11:2262–2266PubMed
23.
go back to reference Ware DE, Huda W, Mergo PJ, Litwiller AL (1999) Radiation effective doses to patients undergoing abdominal CT examinations. Radiology 210:645–650PubMed Ware DE, Huda W, Mergo PJ, Litwiller AL (1999) Radiation effective doses to patients undergoing abdominal CT examinations. Radiology 210:645–650PubMed
24.
go back to reference Starck G, Lonn L, Cederblad A, Alpsten M, Sjostrom L, Ekholm S (1998) Radiation dose reduction in CT: application to tissue area and volume determination. Radiology 209:397–403PubMed Starck G, Lonn L, Cederblad A, Alpsten M, Sjostrom L, Ekholm S (1998) Radiation dose reduction in CT: application to tissue area and volume determination. Radiology 209:397–403PubMed
25.
go back to reference Katz E, Hana R, Jurim O, Pisuv G, Gutman A, Durst AL (1990) Experimental model of acute appendicitis in the rabbit with determination of leucine amino peptidase (LAP) and acid phosphatase (Acid-P) activities in portal blood samples. J Surg Res 48:230–236PubMed Katz E, Hana R, Jurim O, Pisuv G, Gutman A, Durst AL (1990) Experimental model of acute appendicitis in the rabbit with determination of leucine amino peptidase (LAP) and acid phosphatase (Acid-P) activities in portal blood samples. J Surg Res 48:230–236PubMed
26.
go back to reference Dachmann AH, Nichols JB, Patrick DH, Lichtenstein JE (1987) Natural history of the obstructed rabbit appendix: observations with radiography, sonography and CT. Am J Roentgenol 148:281–284 Dachmann AH, Nichols JB, Patrick DH, Lichtenstein JE (1987) Natural history of the obstructed rabbit appendix: observations with radiography, sonography and CT. Am J Roentgenol 148:281–284
27.
go back to reference Hsieh J (1999) Three dimensional artifact induced by projection weighting and misalignment. IEEE Trans Med Imaging 18:364–368CrossRefPubMed Hsieh J (1999) Three dimensional artifact induced by projection weighting and misalignment. IEEE Trans Med Imaging 18:364–368CrossRefPubMed
28.
go back to reference Cohen J (1960) Coefficient of agreement for nominal scales. Educ Psychol Meas 20:37–46 Cohen J (1960) Coefficient of agreement for nominal scales. Educ Psychol Meas 20:37–46
29.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMed
30.
go back to reference Cohnen M, Poll LJ, Puettmann C, Ewen K, Saleh A, Modder U (2003) Effective doses in standard protocols for multi-slice CT scanning. Eur Radiol 13:1148–1153PubMed Cohnen M, Poll LJ, Puettmann C, Ewen K, Saleh A, Modder U (2003) Effective doses in standard protocols for multi-slice CT scanning. Eur Radiol 13:1148–1153PubMed
31.
go back to reference Birnbaum BA, Wilson SR (2000) Appendicitis at the millennium. Radiology 215:337–348 Birnbaum BA, Wilson SR (2000) Appendicitis at the millennium. Radiology 215:337–348
32.
go back to reference Carty HM (2002) Paedtriac emergencies: non-traumatic abdominal emergencies. Eur Radiol 12:2835–2848PubMed Carty HM (2002) Paedtriac emergencies: non-traumatic abdominal emergencies. Eur Radiol 12:2835–2848PubMed
33.
go back to reference Ron E (2002) Let’s not relive the past: a review of cancer risk after diagnostic or therapeutic irradiation. Pediatr Radiol 32:739–744CrossRefPubMed Ron E (2002) Let’s not relive the past: a review of cancer risk after diagnostic or therapeutic irradiation. Pediatr Radiol 32:739–744CrossRefPubMed
34.
go back to reference Hall EJ (2002) Lessons we have learned from our children: cancer risks from diagnostic radiology. Pediatr Radiol 32:700–706CrossRefPubMed Hall EJ (2002) Lessons we have learned from our children: cancer risks from diagnostic radiology. Pediatr Radiol 32:700–706CrossRefPubMed
35.
go back to reference Greess H, Nomayr A, Wolf H, Baum U, Lell M, Bowing B, Kalender W, Bautz WA (2002) Dose reduction in CT examinations of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12:1571–1576PubMed Greess H, Nomayr A, Wolf H, Baum U, Lell M, Bowing B, Kalender W, Bautz WA (2002) Dose reduction in CT examinations of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12:1571–1576PubMed
36.
go back to reference Tack D, de Maertelaer V, Gevenois PA (2003) Dose eduction in multidetector CT using attenuation-based online tube current modulation. Am J Roentgenol 181:331–334 Tack D, de Maertelaer V, Gevenois PA (2003) Dose eduction in multidetector CT using attenuation-based online tube current modulation. Am J Roentgenol 181:331–334
37.
go back to reference International Conference on Dose in Computed Tomography. Nürnberg, 2001 International Conference on Dose in Computed Tomography. Nürnberg, 2001
39.
40.
go back to reference Kalra MK, Prasad S, Saini S, Blake MA, Varghese J, Halpern EF, Thrall JH (2002) Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality. Am J Roentgenol 179:1101–1106 Kalra MK, Prasad S, Saini S, Blake MA, Varghese J, Halpern EF, Thrall JH (2002) Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality. Am J Roentgenol 179:1101–1106
41.
go back to reference Kamel IR, Hernandez RJ, Martin JE, Schlesinger AE, Niklason LT, Guire KE (1994) Radiation dose reduction in CT of the pediatric pelvis. Radiology 190:683–687PubMed Kamel IR, Hernandez RJ, Martin JE, Schlesinger AE, Niklason LT, Guire KE (1994) Radiation dose reduction in CT of the pediatric pelvis. Radiology 190:683–687PubMed
Metadata
Title
The effect of varying low-dose protocols on perceived image quality in multidetector CT in a rabbit model of acute appendicitis
Authors
Marcus Hörmann
Marcel O. Philipp
Heidrun Eberl
Ursula Windberger
Wolfgang Matzek
Cornelia Schäfer-Prokop
Viktor M. Metz
Publication date
01-08-2004
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2004
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2318-0

Other articles of this Issue 8/2004

European Radiology 8/2004 Go to the issue