Skip to main content
Top
Published in: European Radiology 8/2003

01-08-2003 | Physics

Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

Authors: G. Brix, H. D. Nagel, G. Stamm, R. Veit, U. Lechel, J. Griebel, M. Galanski

Published in: European Radiology | Issue 8/2003

Login to get access

Abstract

Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case.
Literature
1.
go back to reference Kalender WA, Seissler W, Klotz E, Vock O (1990) Spiral volumetric CT with single-breath-hold technique, continuous transport, and scanner rotation. Radiology 176:181–183PubMed Kalender WA, Seissler W, Klotz E, Vock O (1990) Spiral volumetric CT with single-breath-hold technique, continuous transport, and scanner rotation. Radiology 176:181–183PubMed
2.
go back to reference Liang Y, Kruger RA (1996) Dual-slice spiral versus single-slice spiral scanning: comparison of the physical performance of two computed tomography scanners. Med Phys 23:205–220PubMed Liang Y, Kruger RA (1996) Dual-slice spiral versus single-slice spiral scanning: comparison of the physical performance of two computed tomography scanners. Med Phys 23:205–220PubMed
3.
go back to reference Klingenbeck-Regn K, Schaller S, Flohr T, Ohnesorge B, Kopp AF, Baum U (1999) Subsecond multi-slice computed tomography: basics and applications. Eur J Radiol 31:110–124PubMed Klingenbeck-Regn K, Schaller S, Flohr T, Ohnesorge B, Kopp AF, Baum U (1999) Subsecond multi-slice computed tomography: basics and applications. Eur J Radiol 31:110–124PubMed
4.
go back to reference Fuchs TO, Kachelriess M, Kalender WA (2000) System performance of multislice spiral computed tomography. IEEE Eng Med Biol Mag 19:63–70 Fuchs TO, Kachelriess M, Kalender WA (2000) System performance of multislice spiral computed tomography. IEEE Eng Med Biol Mag 19:63–70
5.
go back to reference Fuchs T, Kachelriess M, Kalender WA (2000) Technical advances in multi-slice spiral CT. Eur J Radiol 36:69–73PubMed Fuchs T, Kachelriess M, Kalender WA (2000) Technical advances in multi-slice spiral CT. Eur J Radiol 36:69–73PubMed
6.
go back to reference Rubin GD (2000) Data explosion: the challenge of multidetector-row CT. Eur J Radiol 36:74–80PubMed Rubin GD (2000) Data explosion: the challenge of multidetector-row CT. Eur J Radiol 36:74–80PubMed
7.
go back to reference Dawson P, Lees WR (2001) Multi-slice technology in computed tomography. Clin Radiol 56:302–309PubMed Dawson P, Lees WR (2001) Multi-slice technology in computed tomography. Clin Radiol 56:302–309PubMed
8.
go back to reference Rydberg J, Buckalter KA, Caldemeyer KS, Phillips MD, Conces DJ, Aisen AM, Persohn SA, Kopecky KK (2000) Multisection CT: scanning techniques and clinical applications. Radiographics 20:1787–1806PubMed Rydberg J, Buckalter KA, Caldemeyer KS, Phillips MD, Conces DJ, Aisen AM, Persohn SA, Kopecky KK (2000) Multisection CT: scanning techniques and clinical applications. Radiographics 20:1787–1806PubMed
9.
go back to reference Berland LL, Smith JK (1998) Multidetector-array CT: once again, technology creates new opportunities. Radiology 209:327–329 Berland LL, Smith JK (1998) Multidetector-array CT: once again, technology creates new opportunities. Radiology 209:327–329
10.
go back to reference Kopecky KK, Buckwalter KA, Sokiranski R (1999) Multi-slice CT: spirals past single-slice CT in diagnostic efficacy. Diagn Imaging 21:36–42 Kopecky KK, Buckwalter KA, Sokiranski R (1999) Multi-slice CT: spirals past single-slice CT in diagnostic efficacy. Diagn Imaging 21:36–42
11.
go back to reference Knez A, Becker CR, Leber A, Ohnesorge B, Becker A, White C, Haberl R, Reiser MF, Steinbeck G (2001) Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses. Am J Cardiol 88:1191–1194PubMed Knez A, Becker CR, Leber A, Ohnesorge B, Becker A, White C, Haberl R, Reiser MF, Steinbeck G (2001) Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses. Am J Cardiol 88:1191–1194PubMed
12.
go back to reference Nieman K, Rensing BJ, van Geuns RJ, Munne A, Ligthart JM, Pattynama PM, Krestin GP, Serruys PW, de Feyter PJ (2002) Usefulness of multislice computed tomography for detecting obstructive coronary artery disease. Am J Cardiol 89:913–918CrossRefPubMed Nieman K, Rensing BJ, van Geuns RJ, Munne A, Ligthart JM, Pattynama PM, Krestin GP, Serruys PW, de Feyter PJ (2002) Usefulness of multislice computed tomography for detecting obstructive coronary artery disease. Am J Cardiol 89:913–918CrossRefPubMed
13.
go back to reference Schroeder S, Kopp AF, Ohnesorge B, Loke-Gie H, Kuettner A, Baumbach A, Herdeg C, Claussen CD, Karsch KR (2002) Virtual coronary angioscopy using multislice computed tomography. Heart 87:205–209PubMed Schroeder S, Kopp AF, Ohnesorge B, Loke-Gie H, Kuettner A, Baumbach A, Herdeg C, Claussen CD, Karsch KR (2002) Virtual coronary angioscopy using multislice computed tomography. Heart 87:205–209PubMed
14.
go back to reference Gerber TC, Kuzo RS, Karstaedt N, Lane GE, Morin RL, Sheedy PF, Safford RE, Blackshear JL, Pietan JH (2002) Current results and new developments of coronary angiography with use of contrast-enhanced computed tomography of the heart. Mayo Clin Proc 77:55–71PubMed Gerber TC, Kuzo RS, Karstaedt N, Lane GE, Morin RL, Sheedy PF, Safford RE, Blackshear JL, Pietan JH (2002) Current results and new developments of coronary angiography with use of contrast-enhanced computed tomography of the heart. Mayo Clin Proc 77:55–71PubMed
15.
go back to reference Hong C, Becker CR, Schoepf UJ, Ohnesorge B, Bruening R, Reiser MF (2002) Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies. Radiology 223:474–480PubMed Hong C, Becker CR, Schoepf UJ, Ohnesorge B, Bruening R, Reiser MF (2002) Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies. Radiology 223:474–480PubMed
16.
go back to reference Bruzzi JF, Moss AC, Fenlon HM (2001) Clinical results of virtual colonoscopy. Eur Radiol 11:2188–2194PubMed Bruzzi JF, Moss AC, Fenlon HM (2001) Clinical results of virtual colonoscopy. Eur Radiol 11:2188–2194PubMed
17.
go back to reference Luboldt W, Fletcher JG, Vogl TJ (2002) Colonography: current status, research directions and challenges. Update 2002. Eur Radiol 12:502–524PubMed Luboldt W, Fletcher JG, Vogl TJ (2002) Colonography: current status, research directions and challenges. Update 2002. Eur Radiol 12:502–524PubMed
18.
go back to reference UNSCEAR (2000) 2000 report, vol I. Sources and effects of ionizing radiation. Annex D: Medical radiation exposures. United Nations Sales Publications UNSCEAR (2000) 2000 report, vol I. Sources and effects of ionizing radiation. Annex D: Medical radiation exposures. United Nations Sales Publications
19.
go back to reference Bundesamt für Strahlenschutz. Jahresbericht 2000. http://www.bfs.de Bundesamt für Strahlenschutz. Jahresbericht 2000. http://​www.​bfs.​de
20.
go back to reference European Commission (1999) Report EUR 16262 EN: European guidelines on quality criteria for computed tomography European Commission (1999) Report EUR 16262 EN: European guidelines on quality criteria for computed tomography
21.
go back to reference Seifert H, Hagen T, Bartylla K, Blass G, Piepgras U (1997) Patient doses from standard and spiral CT of the head using a fast twin-beam system. Br J Radiol 70:1139–1145PubMed Seifert H, Hagen T, Bartylla K, Blass G, Piepgras U (1997) Patient doses from standard and spiral CT of the head using a fast twin-beam system. Br J Radiol 70:1139–1145PubMed
22.
go back to reference Giacomuzzi SM, Torbica P, Rieger M, Lottersberger C, Peer S, Peer R, Perkmann R, Buchberger W, Bale R, Mallouhi A, Jaschke W (2001) Evaluation of radiation exposure with single-slice and a multi-slice CT system (a phantom study). Fortschr Rontgenstr 173:643–649 Giacomuzzi SM, Torbica P, Rieger M, Lottersberger C, Peer S, Peer R, Perkmann R, Buchberger W, Bale R, Mallouhi A, Jaschke W (2001) Evaluation of radiation exposure with single-slice and a multi-slice CT system (a phantom study). Fortschr Rontgenstr 173:643–649
23.
go back to reference Moro L, Bolsi A, Baldi M, Bertoli G, Fantinato D (2001) Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference levels. Radiol Med 102:262–265 Moro L, Bolsi A, Baldi M, Bertoli G, Fantinato D (2001) Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference levels. Radiol Med 102:262–265
24.
go back to reference Galanski M, Nagel HD, Stamm G (2001) CT-Expositionspraxis in der Bundesrepublik Deutschland. Fortschr Rontgenstr 173:R1–R66 Galanski M, Nagel HD, Stamm G (2001) CT-Expositionspraxis in der Bundesrepublik Deutschland. Fortschr Rontgenstr 173:R1–R66
25.
go back to reference Nagel HD, Galanski M, Hidajat N, Maier W, Schmidt T (2000) Radiation exposure in computed tomography: fundamentals, influencing parameters, dose assessment, optimisation, scanner data, terminology. COCIR, Frankfurt Nagel HD, Galanski M, Hidajat N, Maier W, Schmidt T (2000) Radiation exposure in computed tomography: fundamentals, influencing parameters, dose assessment, optimisation, scanner data, terminology. COCIR, Frankfurt
26.
go back to reference Stamm G, Nagel HD (2002) CT-Expo: ein neuartiges Programm zur Dosisevaluierung in der CT. Fortschr Rontgenstr 174:1570–1576 Stamm G, Nagel HD (2002) CT-Expo: ein neuartiges Programm zur Dosisevaluierung in der CT. Fortschr Rontgenstr 174:1570–1576
27.
go back to reference ICRP Publication 60 (1991) 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 21/1–3. Elsevier, Oxford ICRP Publication 60 (1991) 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 21/1–3. Elsevier, Oxford
28.
go back to reference Zankl M, Panzer W, Drexler G (1991) The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Part IV. Organ doses from tomographic examinations. GSF report 30/91, Neuherberg Zankl M, Panzer W, Drexler G (1991) The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Part IV. Organ doses from tomographic examinations. GSF report 30/91, Neuherberg
29.
go back to reference Kramer R, Zankl M, Wiliams G, Drexler G (1982) The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Part I. The male (Adam) and female (Eva) adult mathematical phantoms. GSF report S-885, Neuherberg Kramer R, Zankl M, Wiliams G, Drexler G (1982) The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Part I. The male (Adam) and female (Eva) adult mathematical phantoms. GSF report S-885, Neuherberg
30.
go back to reference Shrimpton PC, Jones DG, Hillier MC, Wall BF, Leheron JC, Faulkner K (1991) Survey of CT practice in the UK. Part 2. Dosimetric aspects. NRPB-249, HMSO, 48, London Shrimpton PC, Jones DG, Hillier MC, Wall BF, Leheron JC, Faulkner K (1991) Survey of CT practice in the UK. Part 2. Dosimetric aspects. NRPB-249, HMSO, 48, London
31.
go back to reference European Commission (2000) Report EUR 19604 EN: Recommendations for patient dosimetry in diagnostic radiology using TLD European Commission (2000) Report EUR 19604 EN: Recommendations for patient dosimetry in diagnostic radiology using TLD
32.
go back to reference Huda W, Sandison GA (1984) Estimation of mean organ doses in diagnostic radiology from Rando phantom measurements. Health Phys 47:463–467PubMed Huda W, Sandison GA (1984) Estimation of mean organ doses in diagnostic radiology from Rando phantom measurements. Health Phys 47:463–467PubMed
33.
go back to reference Bushberg JT, Seibert JA, Leidholdt EM, Boone JM (2002) The essential physics of medical imaging, 2nd edn. Lippincott Williams and Wilkins, Philadelphia Bushberg JT, Seibert JA, Leidholdt EM, Boone JM (2002) The essential physics of medical imaging, 2nd edn. Lippincott Williams and Wilkins, Philadelphia
34.
go back to reference Kopp AF, Heuschmid M, Claussen CD (2002) Multidetector helical CT of the liver for tumor detection and characterization. Eur Radiol 12:745–752CrossRefPubMed Kopp AF, Heuschmid M, Claussen CD (2002) Multidetector helical CT of the liver for tumor detection and characterization. Eur Radiol 12:745–752CrossRefPubMed
Metadata
Title
Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey
Authors
G. Brix
H. D. Nagel
G. Stamm
R. Veit
U. Lechel
J. Griebel
M. Galanski
Publication date
01-08-2003
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2003
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1883-y

Other articles of this Issue 8/2003

European Radiology 8/2003 Go to the issue