Abstract

Purpose

This study is aimed to evaluate the effect of generation change on accuracy of IOSs on full-arch scans and the inter-operator reliability.

Methods

In this study, 6 different IOS were tested: 3Shape Trios 3 (20.1.2.), 3Shape Trios 4 (20.1.1.), Medit i500 (2.3.6.), Medit i700 (2.4.6.), Planmeca Emerald (6.0.1.) and Planmeca Emerald S (6.0.1.). Eighteen dental students, inexperienced in scanning, took part in this study as operators. Each operator made 10 digital impressions; altogether, 30 impressions were made by each scanner. The 30 STL files were imported to the Geomagic Control X program, where they were compared to a reference STL file; the surface point’s deviation of the full arch and the distance between the second molars’ distobuccal cusps were measured, the inter-operator reliability was also investigated.

Results

A significant increase in accuracy was found between Trios 3 and 4 in the case of both parameters and between Medit i500 and i700 in the case of full arch. There was no significant difference between Planmeca generations. In case of the inter-operator reliability no significant difference was detected.

Conclusion

Within this current study’s limitation, it can be concluded that surface digitalization’s accuracy can be modified with generation changes and that digital technology is less technique sensitive than traditional impression taking.
Literature
9.
go back to reference Marques S, Ribeiro P, Falc C, Lemos BF, Blanca R. Digital Impressions in Implant Dentistry: A Literature Review 2021. Marques S, Ribeiro P, Falc C, Lemos BF, Blanca R. Digital Impressions in Implant Dentistry: A Literature Review 2021.
11.
go back to reference Ender A, Zimmermann M, Mehl A. Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro. Int J Comput Dent. 2019;22:11–9.PubMed Ender A, Zimmermann M, Mehl A. Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro. Int J Comput Dent. 2019;22:11–9.PubMed
19.
go back to reference Kravitz ND, Groth C, Jones PE, Graham JW, Redmond WR. Intraoral digital scanners. J Clin Orthodontics: JCO. 2014;48:337–47. Kravitz ND, Groth C, Jones PE, Graham JW, Redmond WR. Intraoral digital scanners. J Clin Orthodontics: JCO. 2014;48:337–47.
20.
go back to reference Mehl A, Ender A, Mörmann W, Attin T. Accuracy testing of a new intraoral 3D camera. Int J Comput Dent. 2009;12:11–28.PubMed Mehl A, Ender A, Mörmann W, Attin T. Accuracy testing of a new intraoral 3D camera. Int J Comput Dent. 2009;12:11–28.PubMed
32.
go back to reference Schlenz MA, Schupp B, Schmidt A, Wöstmann B, Baresel I, Krämer N, et al. New Caries Diagnostic Tools in Intraoral Scanners: a comparative in Vitro Study to established methods in Permanent and primary teeth. Sensors. 2022;22. https://doi.org/10.3390/s22062156. Schlenz MA, Schupp B, Schmidt A, Wöstmann B, Baresel I, Krämer N, et al. New Caries Diagnostic Tools in Intraoral Scanners: a comparative in Vitro Study to established methods in Permanent and primary teeth. Sensors. 2022;22. https://​doi.​org/​10.​3390/​s22062156.
34.
39.
go back to reference Róth I, Hermann P, Vitai V, Joós-kovács GL, Géczi Z, Borbély J. Comparison of the learning curve of intraoral scanning with two different intraoral scanners based on scanning time 2023:1–10. Róth I, Hermann P, Vitai V, Joós-kovács GL, Géczi Z, Borbély J. Comparison of the learning curve of intraoral scanning with two different intraoral scanners based on scanning time 2023:1–10.
44.
go back to reference Zimmermann M, Mehl A, Mörmann WH, Reich S. Intraoral scanning systems - a current overview. Int J Comput Dent. 2015;18:101–29.PubMed Zimmermann M, Mehl A, Mörmann WH, Reich S. Intraoral scanning systems - a current overview. Int J Comput Dent. 2015;18:101–29.PubMed
45.
go back to reference Mennito AS, Evans ZP, Nash J, Bocklet C, Lauer (Kelly) A, Bacro T, et al. Evaluation of the trueness and precision of complete arch digital impressions on a human maxilla using seven different intraoral digital impression systems and a laboratory scanner. J Esthetic Restor Dentistry. 2019;31:369–77. https://doi.org/10.1111/jerd.12485.CrossRef Mennito AS, Evans ZP, Nash J, Bocklet C, Lauer (Kelly) A, Bacro T, et al. Evaluation of the trueness and precision of complete arch digital impressions on a human maxilla using seven different intraoral digital impression systems and a laboratory scanner. J Esthetic Restor Dentistry. 2019;31:369–77. https://​doi.​org/​10.​1111/​jerd.​12485.CrossRef
Metadata
Title
The effect of generation change on the accuracy of full arch digital impressions
Authors
Judit Schmalzl
Ivett Róth
Judit Borbély
Péter Hermann
Bálint Vecsei
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-03476-z

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue