Skip to main content
Top
Published in: Heart and Vessels 3/2017

01-03-2017 | Case Report

Surface electromyography of myopotential oversensing provoked by simultaneous straining and leftward twisting in a patient with an implantable cardioverter defibrillator

Authors: Yoichi Ajiro, Tsuyoshi Shiga, Morio Shoda, Nobuhisa Hagiwara

Published in: Heart and Vessels | Issue 3/2017

Login to get access

Abstract

An important step in diagnosing myopotential oversensing is to confirm its reproducibility using specific provocation maneuvers. Although most maneuvers involve the co-contraction of many muscles, no attempt has been made to assess relevant muscle activities by electromyography. We describe a case with an implantable cardioverter defibrillator (ICD) whose myopotential oversensing was provoked by simultaneous straining and leftward twisting. Simultaneous recordings from real-time ICD telemetry and myopotentials of the rectus abdominis, oblique abdominis, and diaphragm on electromyography during the provocation maneuvers were conducted. It was shown that all three muscles contracted simultaneously during the provocation maneuvers; the diaphragm activity was the main source of noise oversensing, and the twist itself caused oversensing possibly due to the change in the position of the lead. In conclusion, the electromyographic assessment of relevant muscle activities may be useful in assessing each muscle’s role and its contribution to myopotential oversensing, especially in a patient whose myopotential oversensing requires complex maneuvers to be provoked.
Literature
1.
go back to reference Ejima K, Shoda M, Yashiro B, Yoshida K, Nuki T, Kato K, Manaka T, Hagiwara N (2014) Unusual “ratchet syndrome”: spontaneous lead retraction after a generator exchange. Heart Vessels 29:550–553CrossRefPubMed Ejima K, Shoda M, Yashiro B, Yoshida K, Nuki T, Kato K, Manaka T, Hagiwara N (2014) Unusual “ratchet syndrome”: spontaneous lead retraction after a generator exchange. Heart Vessels 29:550–553CrossRefPubMed
2.
go back to reference Swerdlow CD, Friedman PA (2005) Advanced ICD troubleshooting: Part I. Pacing Clin Electrophysiol 28:1322–1346CrossRefPubMed Swerdlow CD, Friedman PA (2005) Advanced ICD troubleshooting: Part I. Pacing Clin Electrophysiol 28:1322–1346CrossRefPubMed
3.
go back to reference Schulte B, Sperzel J, Carlsson J, Dursch M, Erdogan A, Pitschner HF, Neuzner J (2001) Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials. J Interv Card Electrophysiol 5:487–493CrossRefPubMed Schulte B, Sperzel J, Carlsson J, Dursch M, Erdogan A, Pitschner HF, Neuzner J (2001) Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials. J Interv Card Electrophysiol 5:487–493CrossRefPubMed
4.
go back to reference Santos KR, Adragao P, Cavaco D, Morgado FB, Candeias R, Lima S, Silva JA (2008) Diaphragmatic myopotential oversensing in pacemaker-dependent patients with CRT-D devices. Europace 10:1381–1386CrossRefPubMed Santos KR, Adragao P, Cavaco D, Morgado FB, Candeias R, Lima S, Silva JA (2008) Diaphragmatic myopotential oversensing in pacemaker-dependent patients with CRT-D devices. Europace 10:1381–1386CrossRefPubMed
5.
go back to reference Salukhe TV, Wright I, Wright M, Kanagaratnam P, O’Neill MD (2008) A fortuitous syncope. The pitfalls of integrated bipolar defibrillator leads. Indian Pacing Electrophysiol J 8:312–316PubMedPubMedCentral Salukhe TV, Wright I, Wright M, Kanagaratnam P, O’Neill MD (2008) A fortuitous syncope. The pitfalls of integrated bipolar defibrillator leads. Indian Pacing Electrophysiol J 8:312–316PubMedPubMedCentral
6.
go back to reference Hayashi Y, Takagi M, Kakihara J, Sakamoto S, Doi A, Sugioka K, Hanatani A, Yoshiyama M (2016) Safety and efficacy of high-rate cutoff and long detection interval ICD programming in secondary prevention patients. Heart Vessels. doi:10.1007/s00380-016-0850-x Hayashi Y, Takagi M, Kakihara J, Sakamoto S, Doi A, Sugioka K, Hanatani A, Yoshiyama M (2016) Safety and efficacy of high-rate cutoff and long detection interval ICD programming in secondary prevention patients. Heart Vessels. doi:10.​1007/​s00380-016-0850-x
7.
go back to reference Barakpour H, Emkanjoo Z, Alizadeh A, Sadr-Ameli MA (2009) Inappropriate shock delivered by implantable cardioverter defibrillator-cardiac resynchronization therapy (ICD-CRT) due to myopotential oversensing. Indian Pacing Electrophysiol J 9:71–74PubMedPubMedCentral Barakpour H, Emkanjoo Z, Alizadeh A, Sadr-Ameli MA (2009) Inappropriate shock delivered by implantable cardioverter defibrillator-cardiac resynchronization therapy (ICD-CRT) due to myopotential oversensing. Indian Pacing Electrophysiol J 9:71–74PubMedPubMedCentral
8.
go back to reference Rauwolf T, Guenther M, Hass N, Schnabel A, Bock M, Braun MU, Strasser RH (2007) Ventricular oversensing in 518 patients with implanted cardiac defibrillators: incidence, complications, and solutions. Europace 9:1041–1047CrossRefPubMed Rauwolf T, Guenther M, Hass N, Schnabel A, Bock M, Braun MU, Strasser RH (2007) Ventricular oversensing in 518 patients with implanted cardiac defibrillators: incidence, complications, and solutions. Europace 9:1041–1047CrossRefPubMed
10.
go back to reference Konrad P (2005) The ABC of EMG: a practical introduction to kinesiological electromyography. Noraxon Inc., Scottsdale Konrad P (2005) The ABC of EMG: a practical introduction to kinesiological electromyography. Noraxon Inc., Scottsdale
11.
go back to reference De Troyer ALS (1995) Actions of the respiratory muscles. In: Lenfant C (ed) Lung biology in health and disease. Marcel Dekker, New York, pp 535–563 De Troyer ALS (1995) Actions of the respiratory muscles. In: Lenfant C (ed) Lung biology in health and disease. Marcel Dekker, New York, pp 535–563
12.
go back to reference McGill SM (1991) Electromyographic activity of the abdominal and low back musculature during the generation of isometric and dynamic axial trunk torque: implications for lumbar mechanics. J Orthop Res 9:91–103CrossRefPubMed McGill SM (1991) Electromyographic activity of the abdominal and low back musculature during the generation of isometric and dynamic axial trunk torque: implications for lumbar mechanics. J Orthop Res 9:91–103CrossRefPubMed
13.
go back to reference Mann DE, Otto L, Kelly PA, Reiter MJ (2000) Effect of sensing system on the incidence of myopotential oversensing during bradycardia pacing in implantable cardioverter-defibrillators. Am J Cardiol 85:1380–1382CrossRefPubMed Mann DE, Otto L, Kelly PA, Reiter MJ (2000) Effect of sensing system on the incidence of myopotential oversensing during bradycardia pacing in implantable cardioverter-defibrillators. Am J Cardiol 85:1380–1382CrossRefPubMed
14.
go back to reference Peters RW, Cooklin M, Brockman R, Shorofsky SR, Gold MR (1998) Inappropriate shocks from implanted cardioverter defibrillators caused by sensing of diaphragmatic myopotentials. J Interv Card Electrophysiol 2:367–370CrossRefPubMed Peters RW, Cooklin M, Brockman R, Shorofsky SR, Gold MR (1998) Inappropriate shocks from implanted cardioverter defibrillators caused by sensing of diaphragmatic myopotentials. J Interv Card Electrophysiol 2:367–370CrossRefPubMed
15.
go back to reference Corzani A, Ziacchi M, Biffi M, Diemberger I, Martignani C, Boriani G (2015) Inappropriate shock for myopotential over-sensing in a patient with subcutaneous ICD. Indian Heart J 67:56–59CrossRefPubMedPubMedCentral Corzani A, Ziacchi M, Biffi M, Diemberger I, Martignani C, Boriani G (2015) Inappropriate shock for myopotential over-sensing in a patient with subcutaneous ICD. Indian Heart J 67:56–59CrossRefPubMedPubMedCentral
16.
17.
go back to reference Requena-Carrlόn J, Vӓisӓnen J, Alonzo-Atienza J, Rojo-Άlvarez JL, Hyttinen J, Garcίa-Alberola A (2007) Comparison of the scope of true and integrated bipolar leads in implantable cardioverter defibrillators. Computers in cardiology, Durham, pp 233–236 Requena-Carrlόn J, Vӓisӓnen J, Alonzo-Atienza J, Rojo-Άlvarez JL, Hyttinen J, Garcίa-Alberola A (2007) Comparison of the scope of true and integrated bipolar leads in implantable cardioverter defibrillators. Computers in cardiology, Durham, pp 233–236
Metadata
Title
Surface electromyography of myopotential oversensing provoked by simultaneous straining and leftward twisting in a patient with an implantable cardioverter defibrillator
Authors
Yoichi Ajiro
Tsuyoshi Shiga
Morio Shoda
Nobuhisa Hagiwara
Publication date
01-03-2017
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 3/2017
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-016-0888-9

Other articles of this Issue 3/2017

Heart and Vessels 3/2017 Go to the issue