Skip to main content
Top
Published in: Pediatric Cardiology 4/2019

01-04-2019 | Supraventricular Tachycardia | Original Article

Usefulness of Electroanatomical Mapping with Contact Force Monitoring for Accessory Pathways Ablation in Pediatric Population

Authors: Simone Gulletta, Pasquale Vergara, Lorenzo Gigli, Giuseppe D’Angelo, Andrea Radinovic, Carmela Melania Barbaro, Nicola Trevisi, Paolo Della Bella

Published in: Pediatric Cardiology | Issue 4/2019

Login to get access

Abstract

The current approach for catheter ablation (CA) of accessory pathways (AP) includes the use of standard catheters under fluoroscopic visualization. We hypothesize that use of contact force (CF) irrigated tip catheters might increase procedural safety in pediatric patients compared to standard irrigated tip catheters, by decreasing the number of radiofrequency (RF) pulses required to obtain AP elimination. Seventy-one pediatric patients (13.7 ± 2.5 years, 45 male) with ventricular pre-excitation were enrolled in the study. CA was performed with a standard irrigated tip catheter up to June 2013 in 41 patients (Group S) and with a CF sensing irrigated tip catheter later on in 30 patients (Group CF). In the Group CF, RF was applied with a minimal CF of 5 g; CF > 35 g was avoided. Group CF procedures required less fluoroscopy (6.8 ± 4.8 min), compared to Group S (12.2 ± 10.8 min, p = 0.007). The number of RF pulses was smaller in Group CF compared to Group S (2.5 ± 2.0 vs 5.5 ± 1.9, p < 0.01). The mean CF during the effective RF pulse was 18 ± 7.7 g, force–time integral was 1040.7 ± 955.9 gs, Ablation Index was 513.0 ± 214.2. The procedure was acutely successful in 70 patients; at 12 months follow-up 2 patients had AP recurrence, one for each group. No major complications were reported. The use of CF irrigated tip catheters was associated with a smaller number of RF pulses and less fluoroscopy, as compared to mapping and ablation with standard irrigated tip catheters.
Literature
1.
go back to reference Kugler JD, Danford DA, Deal BJ, Gillette PC, Perry JC, Silka MJ, Van Hare GF, Walsh EP (1994) Radiofrequency catheter ablation for tachyarrhythmias in children and adolescents. The Pediatric Electrophysiology Society. N Engl J Med 330:1481–1487CrossRefPubMed Kugler JD, Danford DA, Deal BJ, Gillette PC, Perry JC, Silka MJ, Van Hare GF, Walsh EP (1994) Radiofrequency catheter ablation for tachyarrhythmias in children and adolescents. The Pediatric Electrophysiology Society. N Engl J Med 330:1481–1487CrossRefPubMed
2.
go back to reference Brugada J, Blom N, Sarquella-Brugada G, Blomstrom-Lundqvist C, Deanfield J, Janousek J, Abrams D, Bauersfeld U, Brugada R, Drago F, de Groot N, Happonen JM, Hebe J, Yen Ho S, Marijon E, Paul T, Pfammatter JP, Rosenthal E, European Heart Rhythm Association, Association for European Paediatric and Congenital Cardiology (2013) Pharmacological and non-pharmacological therapy for arrhythmias in the pediatric population: EHRA and AEPC-Arrhythmia Working Group joint consensus statement. Europace 15:1337–1382CrossRefPubMed Brugada J, Blom N, Sarquella-Brugada G, Blomstrom-Lundqvist C, Deanfield J, Janousek J, Abrams D, Bauersfeld U, Brugada R, Drago F, de Groot N, Happonen JM, Hebe J, Yen Ho S, Marijon E, Paul T, Pfammatter JP, Rosenthal E, European Heart Rhythm Association, Association for European Paediatric and Congenital Cardiology (2013) Pharmacological and non-pharmacological therapy for arrhythmias in the pediatric population: EHRA and AEPC-Arrhythmia Working Group joint consensus statement. Europace 15:1337–1382CrossRefPubMed
3.
go back to reference Van Hare GF, Javitz H, Carmelli D, Saul JP, Tanel RE, Fischbach PS, Kanter RJ, Schaffer M, Dunnigan A, Colan S, Serwer G, Pediatric Electrophysiology Society (2004) Prospective assessment after pediatric cardiac ablation: demographics, medical profiles, and initial outcomes. J Cardiovasc Electrophysiol 15:759–770CrossRefPubMed Van Hare GF, Javitz H, Carmelli D, Saul JP, Tanel RE, Fischbach PS, Kanter RJ, Schaffer M, Dunnigan A, Colan S, Serwer G, Pediatric Electrophysiology Society (2004) Prospective assessment after pediatric cardiac ablation: demographics, medical profiles, and initial outcomes. J Cardiovasc Electrophysiol 15:759–770CrossRefPubMed
4.
go back to reference Mizuno H, Vergara P, Maccabelli G, Trevisi N, Eng SC, Brombin C, Mazzone P, Della Bella P (2013) Contact force monitoring for cardiac mapping in patients with ventricular tachycardia. J Cardiovasc Electrophysiol 24:519–524CrossRefPubMed Mizuno H, Vergara P, Maccabelli G, Trevisi N, Eng SC, Brombin C, Mazzone P, Della Bella P (2013) Contact force monitoring for cardiac mapping in patients with ventricular tachycardia. J Cardiovasc Electrophysiol 24:519–524CrossRefPubMed
5.
go back to reference Smeets JL, Ben-Haim SA, Rodriguez LM, Timmermans C, Wellens HJ (1998) New method for nonfluoroscopic endocardial mapping in humans: accuracy assessment and first clinical results. Circulation 97:2426–2432CrossRefPubMed Smeets JL, Ben-Haim SA, Rodriguez LM, Timmermans C, Wellens HJ (1998) New method for nonfluoroscopic endocardial mapping in humans: accuracy assessment and first clinical results. Circulation 97:2426–2432CrossRefPubMed
6.
go back to reference Padovani R, Bernardi G, Malisan MR, Vano E, Morocutti G, Fioretti PM (2001) Patient dose related to the complexity of interventional cardiology procedures. Radiat Prot Dosimetry 94:189–192CrossRefPubMed Padovani R, Bernardi G, Malisan MR, Vano E, Morocutti G, Fioretti PM (2001) Patient dose related to the complexity of interventional cardiology procedures. Radiat Prot Dosimetry 94:189–192CrossRefPubMed
7.
go back to reference ICRU (2005) Patient dosimetry for X rays used in medical imaging. J ICRU 5:1–113 ICRU (2005) Patient dosimetry for X rays used in medical imaging. J ICRU 5:1–113
8.
go back to reference Rehani MM, Ciraj-Bjelac O, Vano E, Miller DL, Walsh S, Giordano BD, Persliden J (2010) ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP 40:1–102CrossRefPubMed Rehani MM, Ciraj-Bjelac O, Vano E, Miller DL, Walsh S, Giordano BD, Persliden J (2010) ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP 40:1–102CrossRefPubMed
9.
go back to reference Gulletta S, Tsiachris D, Della Bella P (2014) Catheter ablation of an anteroseptal accessory pathway guided by contact force monitoring technology and precise electroanatomical mapping. Europace 16:825CrossRefPubMed Gulletta S, Tsiachris D, Della Bella P (2014) Catheter ablation of an anteroseptal accessory pathway guided by contact force monitoring technology and precise electroanatomical mapping. Europace 16:825CrossRefPubMed
10.
go back to reference Lin K, Chen S, Lin Y, Chang K (2006) Irrigated and cooledtip radiofrequency catheter ablation. In: Huang S, Wood M (eds) Catheter ablation of cardiac arrhythmias. WB Saunders, Philadelphia, pp 35–48CrossRef Lin K, Chen S, Lin Y, Chang K (2006) Irrigated and cooledtip radiofrequency catheter ablation. In: Huang S, Wood M (eds) Catheter ablation of cardiac arrhythmias. WB Saunders, Philadelphia, pp 35–48CrossRef
11.
go back to reference Yildirim I, Karagoz T, Ertugrul I, Karagoz AH, Ozer S (2013) Efficacy and safety of cryoablation of parahissian accessory pathways in children: a single institution study. Pacing Clin Electrophysiol 36:1495–1502CrossRefPubMed Yildirim I, Karagoz T, Ertugrul I, Karagoz AH, Ozer S (2013) Efficacy and safety of cryoablation of parahissian accessory pathways in children: a single institution study. Pacing Clin Electrophysiol 36:1495–1502CrossRefPubMed
12.
go back to reference Kirsh JA, Gross GJ, O’Connor S, Hamilton RM, Cryocath International Patient Registry (2005) Transcatheter cryoablation of tachyarrhythmias in children: initial experience from an international registry. J Am Coll Cardiol 45:133–136CrossRefPubMed Kirsh JA, Gross GJ, O’Connor S, Hamilton RM, Cryocath International Patient Registry (2005) Transcatheter cryoablation of tachyarrhythmias in children: initial experience from an international registry. J Am Coll Cardiol 45:133–136CrossRefPubMed
13.
go back to reference Kriebel T, Broistedt C, Kroll M, Sigler M, Paul T (2005) Efficacy and safety of cryoenergy in the ablation of atrioventricular reentrant tachycardia substrates in children and adolescents. J Cardiovasc Electrophysiol 16:960–966CrossRefPubMed Kriebel T, Broistedt C, Kroll M, Sigler M, Paul T (2005) Efficacy and safety of cryoenergy in the ablation of atrioventricular reentrant tachycardia substrates in children and adolescents. J Cardiovasc Electrophysiol 16:960–966CrossRefPubMed
14.
go back to reference Kuck KH, Reddy VY, Schmidt B, Natale A, Neuzil P, Saoudi N, Kautzner J, Herrera C, Hindricks G, Jais P, Nakagawa H, Lambert H, Shah DC (2012) A novel radiofrequency ablation catheter using contact force sensing: TOCCATA study. Heart Rhythm 9:18–23CrossRefPubMed Kuck KH, Reddy VY, Schmidt B, Natale A, Neuzil P, Saoudi N, Kautzner J, Herrera C, Hindricks G, Jais P, Nakagawa H, Lambert H, Shah DC (2012) A novel radiofrequency ablation catheter using contact force sensing: TOCCATA study. Heart Rhythm 9:18–23CrossRefPubMed
15.
go back to reference Perna F, Heist EK, Danik SB, Barrett CD, Ruskin JN, Mansour M (2011) Assessment of the catheter tip contact force resulting in cardiac perforation in the swine atria using the force sensing technology. Circ Arrhythm Electrophysiol 4:218–224CrossRefPubMed Perna F, Heist EK, Danik SB, Barrett CD, Ruskin JN, Mansour M (2011) Assessment of the catheter tip contact force resulting in cardiac perforation in the swine atria using the force sensing technology. Circ Arrhythm Electrophysiol 4:218–224CrossRefPubMed
16.
go back to reference Yamane T, Jais P, Shah DC, Hocini M, Peng JT, Deisenhofer I, Clementy J, Haissaguerre M (2000) Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation. Circulation 102:2565–2568CrossRefPubMed Yamane T, Jais P, Shah DC, Hocini M, Peng JT, Deisenhofer I, Clementy J, Haissaguerre M (2000) Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation. Circulation 102:2565–2568CrossRefPubMed
17.
go back to reference Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT, Kantipudi C, Mansour MC, Melby DP, Packer DL, Nakagawa H, Zhang B, Stagg RB, Boo LM, Marchlinski FE (2014) Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol 64:647–656CrossRefPubMed Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT, Kantipudi C, Mansour MC, Melby DP, Packer DL, Nakagawa H, Zhang B, Stagg RB, Boo LM, Marchlinski FE (2014) Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol 64:647–656CrossRefPubMed
18.
go back to reference Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, Jais P, Hindricks G, Peichl P, Yulzari A, Lambert H, Neuzil P, Natale A, Kuck KH (2012) The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm 9:1789–1795CrossRefPubMed Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, Jais P, Hindricks G, Peichl P, Yulzari A, Lambert H, Neuzil P, Natale A, Kuck KH (2012) The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm 9:1789–1795CrossRefPubMed
19.
go back to reference Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D (2017) Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace 19:775–783PubMed Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D (2017) Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace 19:775–783PubMed
Metadata
Title
Usefulness of Electroanatomical Mapping with Contact Force Monitoring for Accessory Pathways Ablation in Pediatric Population
Authors
Simone Gulletta
Pasquale Vergara
Lorenzo Gigli
Giuseppe D’Angelo
Andrea Radinovic
Carmela Melania Barbaro
Nicola Trevisi
Paolo Della Bella
Publication date
01-04-2019
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 4/2019
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-019-02051-0

Other articles of this Issue 4/2019

Pediatric Cardiology 4/2019 Go to the issue