Abstract

This study was conducted to compare the shear bond strengths of composite resin bonded to Er:YAG laser or bur-prepared dentin surfaces using three self-etching adhesive systems. The occlusal surfaces of 120 human third molars were ground flat to expose dentin. The dentin was prepared using either a carbide bur or an Er:YAG laser at 350 mJ/pulse and 10 Hz (fluence, 44.5 J/cm2). Three different self-etching adhesive systems were applied: iBond™, Xeno III™ and Clearfil SE Bond™. Rods of composite resin were bonded to dentin surfaces and shear bond tests were carried out. Both dentin surfaces after debonding and resin rods were observed using a scanning electron microscope. When the Xeno III™ was used, no difference was observed on shear bond strength values when bur and Er:YAG laser were compared. When using iBond™ and Clearfil SE Bond™, bond strength values measured on Er:YAG-laser-prepared surfaces were lower than those observed on bur-prepared surfaces. The absence of smear layer formation during the preparation of the dentin by the Er:YAG laser did not improve the adhesion values of self-etching adhesive systems.
Literature
1.
go back to reference Hoke JA, Burkes EJ, Gomes ED, Wolbarsht ML (1990) Erbium:YAG (2.94 μm) laser effects on dental tissues. J Laser Appl 2:61–65PubMed Hoke JA, Burkes EJ, Gomes ED, Wolbarsht ML (1990) Erbium:YAG (2.94 μm) laser effects on dental tissues. J Laser Appl 2:61–65PubMed
2.
go back to reference Visuri SR, Walsh JT, Wigdor HA (1996) Erbium laser ablation of dental hard tissue: effect of water cooling. Lasers Surg Med 18:294–300PubMedCrossRef Visuri SR, Walsh JT, Wigdor HA (1996) Erbium laser ablation of dental hard tissue: effect of water cooling. Lasers Surg Med 18:294–300PubMedCrossRef
3.
go back to reference Curti M, Rocca JP, Bertrand MF, Nammour S (2004) Morpho-structural aspects of Er:YAG prepared class V cavities. J Clin Laser Med Surg 22:119–124PubMedCrossRef Curti M, Rocca JP, Bertrand MF, Nammour S (2004) Morpho-structural aspects of Er:YAG prepared class V cavities. J Clin Laser Med Surg 22:119–124PubMedCrossRef
4.
go back to reference Eguro T, Maeda T, Otsuki M, Nishimura Y, Katsuumi I, Tanaka H (2002) Adhesion of Er:YAG laser-irradiated dentin and composite resins: application of various treatments on irradiated surface. Lasers Surg Med 30:267–272PubMedCrossRef Eguro T, Maeda T, Otsuki M, Nishimura Y, Katsuumi I, Tanaka H (2002) Adhesion of Er:YAG laser-irradiated dentin and composite resins: application of various treatments on irradiated surface. Lasers Surg Med 30:267–272PubMedCrossRef
5.
go back to reference Ramos RP, Chimello DT, Chinelatti MA, Nonaka T, Pecora JD, Palma Dibb RG (2002) Effect of Er:YAG laser on bond strength to dentin of a self-etching primer and two single-bottle adhesive systems. Lasers Surg Med 31:164–170PubMedCrossRef Ramos RP, Chimello DT, Chinelatti MA, Nonaka T, Pecora JD, Palma Dibb RG (2002) Effect of Er:YAG laser on bond strength to dentin of a self-etching primer and two single-bottle adhesive systems. Lasers Surg Med 31:164–170PubMedCrossRef
6.
go back to reference Tay FR, Sano H, Carvalho R, Pashley E, Pashley DH (2000) Ultrastructural study of the influence of acidity of self-etching primers and smear layer thickness on bonding to intact dentin. J Adhes Dent 2:83–98PubMed Tay FR, Sano H, Carvalho R, Pashley E, Pashley DH (2000) Ultrastructural study of the influence of acidity of self-etching primers and smear layer thickness on bonding to intact dentin. J Adhes Dent 2:83–98PubMed
7.
go back to reference Arrais CAG, Giannini M (2002) Morphology and thickness of the diffusion of resin through demineralized or unconditioned dentinal matrix. Pesqui Odontol Bras 16:115–120PubMedCrossRef Arrais CAG, Giannini M (2002) Morphology and thickness of the diffusion of resin through demineralized or unconditioned dentinal matrix. Pesqui Odontol Bras 16:115–120PubMedCrossRef
8.
go back to reference Dostalova T, Jelinkova H, Kresja O, Hamal K (1996) Evaluation of the surface changes in enamel and dentin due to possibility of thermal overheating induced by erbium:YAG laser radiation. Scanning Microsc 10:285–291PubMed Dostalova T, Jelinkova H, Kresja O, Hamal K (1996) Evaluation of the surface changes in enamel and dentin due to possibility of thermal overheating induced by erbium:YAG laser radiation. Scanning Microsc 10:285–291PubMed
9.
go back to reference Armengol V, Jean A, Rohanizadeh R, Hamel H (1999) Scanning electron microscopic analysis of diseased and healthy dental hard tissues after Er:YAG laser irradiation: in vitro study. J Endod 25:543–546PubMedCrossRef Armengol V, Jean A, Rohanizadeh R, Hamel H (1999) Scanning electron microscopic analysis of diseased and healthy dental hard tissues after Er:YAG laser irradiation: in vitro study. J Endod 25:543–546PubMedCrossRef
10.
go back to reference Bertrand MF, Hessleyer D, Muller-Bolla M, Nammour S, Rocca JP (2004) Scanning electron microscopic evaluation of resin–dentin interface after Er:YAG laser preparation. Lasers Surg Med 35:51–57PubMedCrossRef Bertrand MF, Hessleyer D, Muller-Bolla M, Nammour S, Rocca JP (2004) Scanning electron microscopic evaluation of resin–dentin interface after Er:YAG laser preparation. Lasers Surg Med 35:51–57PubMedCrossRef
11.
go back to reference Tay FR, Pashley DH (2003) Have dentin adhesives become too hydrophilic. J Can Dent Assoc 69:726–731PubMed Tay FR, Pashley DH (2003) Have dentin adhesives become too hydrophilic. J Can Dent Assoc 69:726–731PubMed
12.
go back to reference Kaaden C, Powers JM, Friedl KH, Schmalz G (2002) Bond strength of self-etching adhesives to dental hard tissues. Clin Oral Investig 6:155–160PubMedCrossRef Kaaden C, Powers JM, Friedl KH, Schmalz G (2002) Bond strength of self-etching adhesives to dental hard tissues. Clin Oral Investig 6:155–160PubMedCrossRef
13.
go back to reference Trajtenberg CP, Pereira PN, Powers JM (2004) Resin bond strength and micromorphology of human teeth prepared with an erbium:YAG laser. Am J Dent 17:331–336PubMed Trajtenberg CP, Pereira PN, Powers JM (2004) Resin bond strength and micromorphology of human teeth prepared with an erbium:YAG laser. Am J Dent 17:331–336PubMed
14.
go back to reference Ceballos L, Toledano M, Osorio R, Tay FR, Marshall GW (2002) Bonding to Er:YAG laser treated dentin. J Dent Res 81:119–122CrossRef Ceballos L, Toledano M, Osorio R, Tay FR, Marshall GW (2002) Bonding to Er:YAG laser treated dentin. J Dent Res 81:119–122CrossRef
15.
go back to reference Burrow MF, Takakura H, Nakajima M, Inai N, Tagami J (1994) The influence of age and depth of dentin on bonding. Dent Mater 10:241–246PubMedCrossRef Burrow MF, Takakura H, Nakajima M, Inai N, Tagami J (1994) The influence of age and depth of dentin on bonding. Dent Mater 10:241–246PubMedCrossRef
16.
go back to reference Stangel I, Young C, Sacher E, Hanley S (1994) The effect of conditioning on adhesion to human dentin. J Adhes 47:133–149CrossRef Stangel I, Young C, Sacher E, Hanley S (1994) The effect of conditioning on adhesion to human dentin. J Adhes 47:133–149CrossRef
Metadata
Title
Shear bond strength of self-etching adhesive systems to Er:YAG-laser-prepared dentin
Authors
Nathalie Brulat
Jean-Paul Rocca
Eric Leforestier
Gilbert Fiorucci
Samir Nammour
Marie-France Bertrand
Publication date
01-01-2009
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 1/2009
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-007-0519-x

Other articles of this Issue 1/2009

Lasers in Medical Science 1/2009 Go to the issue