Skip to main content
Top
Published in: Heart and Vessels 10/2022

Open Access 12-05-2022 | Original Article

Selection of an impedance- or magnetic field-based electro-anatomical mapping platform does not affect outcomes of outflow tract premature ventricular complex manual ablation

Authors: Pál Ábrahám, Mercédesz Ambrus, Szilvia Herczeg, Nándor Szegedi, Klaudia Vivien Nagy, Zoltán Salló, Péter Perge, István Osztheimer, Gábor Széplaki, Tamás Tahin, Béla Merkely, László Gellér

Published in: Heart and Vessels | Issue 10/2022

Login to get access

Abstract

Comparative data are virtually missing about the performance of different electro-anatomical mapping (EAM) system platforms on outflow tract (OT) premature ventricular complex (PVC) ablation outcomes with manual ablation catheters. We aimed to compare the acute success-, complication-, and long-term recurrence rates of impedance-based (IMP) and magnetic field-based (MAG) EAM platforms in manual OT PVC ablation. Single-centre, propensity score matched data of 39–39 patients ablated for OT PVCs in 2015–17 with IMP or MAG platforms were analysed. Acute success rate, peri-procedural complications, post-ablation daily PVC burden, and long-term recurrence rates were compared on intention-to-treat basis. Acute success rate was similar in the IMP and MAG group (77 vs. 82%, p = 0.78). There was a single case of femoral pseudo-aneurysm and no cardiac tamponade occurred. PVC burden fell significantly from baseline 24.0% [15.0–30.0%] to 3.3% [0.25–10.5%] (p < 0.001) post-ablation, with no difference between EAM platforms (IMP: 2.6% [0.5–12.0%] vs. MAG: 4.0% [2.0–6.5%]; p = 0.60). There was no significant difference in recurrence-free survival of the intention-to-treat cohort of the IMP and MAG groups (54 vs. 60%, p = 0.82, respectively) during 12 months of follow-up. Ablation with the aid of both impedance- and magnetic field-based EAM platforms can considerably reduce OT PVC burden and give similar acute- and long-term freedom from arrhythmia.
Literature
1.
go back to reference Penela D, Fernández-Armenta J, Aguinaga L, Tercedor L, Ordoñez A, Bisbal F, Acosta J, Rossi L, Borras R, Doltra A, Ortiz-Pérez JT, Bosch X, Perea RJ, Prat-González S, Soto-Iglesias D, Tolosana JM, Vassanelli F, Cabrera M, Linhart M, Martinez M, Mont L, Berruezo A (2017) Clinical recognition of pure premature ventricular complex-induced cardiomyopathy at presentation. Heart Rhythm 14(12):1864–1870CrossRef Penela D, Fernández-Armenta J, Aguinaga L, Tercedor L, Ordoñez A, Bisbal F, Acosta J, Rossi L, Borras R, Doltra A, Ortiz-Pérez JT, Bosch X, Perea RJ, Prat-González S, Soto-Iglesias D, Tolosana JM, Vassanelli F, Cabrera M, Linhart M, Martinez M, Mont L, Berruezo A (2017) Clinical recognition of pure premature ventricular complex-induced cardiomyopathy at presentation. Heart Rhythm 14(12):1864–1870CrossRef
2.
go back to reference Zhong L, Lee YH, Huang XM, Asirvatham SJ, Shen WK, Friedman PA, Hodge DO, Slusser JP, Song ZY, Packer DL, Cha YM (2014) Relative efficacy of catheter ablation vs antiarrhythmic drugs in treating premature ventricular contractions: a single-center retrospective study. Heart Rhythm 11(2):187–193CrossRef Zhong L, Lee YH, Huang XM, Asirvatham SJ, Shen WK, Friedman PA, Hodge DO, Slusser JP, Song ZY, Packer DL, Cha YM (2014) Relative efficacy of catheter ablation vs antiarrhythmic drugs in treating premature ventricular contractions: a single-center retrospective study. Heart Rhythm 11(2):187–193CrossRef
3.
go back to reference Priori SG, Blomström-Lundqvist C, Mazzanti A, Blom N, Borggrefe M, Camm J, Elliott PM, Fitzsimons D, Hatala R, Hindricks G, Kirchhof P, Kjeldsen K, Kuck KH, Hernandez-Madrid A, Nikolaou N, Norekvål TM, Spaulding C, Van Veldhuisen DJ (2015) ESC scientific document group. 2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European society of cardiology (ESC). Endorsed by: association for European paediatric and congenital cardiology (AEPC). Eur Heart J 36(41):2793–2867CrossRef Priori SG, Blomström-Lundqvist C, Mazzanti A, Blom N, Borggrefe M, Camm J, Elliott PM, Fitzsimons D, Hatala R, Hindricks G, Kirchhof P, Kjeldsen K, Kuck KH, Hernandez-Madrid A, Nikolaou N, Norekvål TM, Spaulding C, Van Veldhuisen DJ (2015) ESC scientific document group. 2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European society of cardiology (ESC). Endorsed by: association for European paediatric and congenital cardiology (AEPC). Eur Heart J 36(41):2793–2867CrossRef
4.
go back to reference Berruezo A, Penela D, Jáuregui B, Soto-Iglesias D, Aguinaga L, Ordóñez A, Fernández-Armenta J, Martínez M, Tercedor L, Bisbal F, Acosta J, Martí-Almor J, Aceña M, Anguera I, Rossi L, Linhart M, Borràs R, Doltra A, Sánchez P, Ortiz-Pérez JT, Perea RJ, Prat-González S, Teres C, Bosch X (2019) Mortality and morbidity reduction after frequent premature ventricular complexes ablation in patients with left ventricular systolic dysfunction. Europace 21(7):1079–1087CrossRef Berruezo A, Penela D, Jáuregui B, Soto-Iglesias D, Aguinaga L, Ordóñez A, Fernández-Armenta J, Martínez M, Tercedor L, Bisbal F, Acosta J, Martí-Almor J, Aceña M, Anguera I, Rossi L, Linhart M, Borràs R, Doltra A, Sánchez P, Ortiz-Pérez JT, Perea RJ, Prat-González S, Teres C, Bosch X (2019) Mortality and morbidity reduction after frequent premature ventricular complexes ablation in patients with left ventricular systolic dysfunction. Europace 21(7):1079–1087CrossRef
5.
go back to reference Ventura R, Steven D, Klemm HU, Lutomsky B, Müllerleile K, Rostock T, Servatius H, Risius T, Meinertz T, Kuck KH, Willems S (2007) Decennial follow-up in patients with recurrent tachycardia originating from the right ventricular outflow tract: electrophysiologic characteristics and response to treatment. Eur Heart J 28(19):2338–2345CrossRef Ventura R, Steven D, Klemm HU, Lutomsky B, Müllerleile K, Rostock T, Servatius H, Risius T, Meinertz T, Kuck KH, Willems S (2007) Decennial follow-up in patients with recurrent tachycardia originating from the right ventricular outflow tract: electrophysiologic characteristics and response to treatment. Eur Heart J 28(19):2338–2345CrossRef
6.
go back to reference Afzal MR, Chatta J, Samanta A, Waheed S, Mahmoudi M, Vukas R, Gunda S, Reddy M, Dawn B, Lakkireddy D (2015) Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: a systematic review and meta-analysis. Heart Rhythm 12(9):1990–1996CrossRef Afzal MR, Chatta J, Samanta A, Waheed S, Mahmoudi M, Vukas R, Gunda S, Reddy M, Dawn B, Lakkireddy D (2015) Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: a systematic review and meta-analysis. Heart Rhythm 12(9):1990–1996CrossRef
7.
go back to reference Reichlin T, Baldinger SH, Pruvot E, Bisch L, Ammann P, Altmann D, Berte B, Kobza R, Haegeli L, Schlatzer C, Mueller A, Namdar M, Shah D, Burri H, Conte G, Auricchio A, Knecht S, Osswald S, Asatryan B, Seiler J, Roten L, Kühne M, Sticherling C (2021) Impact of contact force sensing technology on outcome of catheter ablation of idiopathic pre-mature ventricular contractions originating from the outflow tracts. Europace 23(4):603–609CrossRef Reichlin T, Baldinger SH, Pruvot E, Bisch L, Ammann P, Altmann D, Berte B, Kobza R, Haegeli L, Schlatzer C, Mueller A, Namdar M, Shah D, Burri H, Conte G, Auricchio A, Knecht S, Osswald S, Asatryan B, Seiler J, Roten L, Kühne M, Sticherling C (2021) Impact of contact force sensing technology on outcome of catheter ablation of idiopathic pre-mature ventricular contractions originating from the outflow tracts. Europace 23(4):603–609CrossRef
8.
go back to reference Ábrahám P, Ambrus M, Herczeg S, Szegedi N, Nagy KV, Salló Z, Osztheimer I, Széplaki G, Tahin T, Merkely B, Gellér L (2021) Similar outcomes with manual contact force ablation catheters and traditional catheters in the treatment of outflow tract premature ventricular complexes. Europace 23(4):596–602CrossRef Ábrahám P, Ambrus M, Herczeg S, Szegedi N, Nagy KV, Salló Z, Osztheimer I, Széplaki G, Tahin T, Merkely B, Gellér L (2021) Similar outcomes with manual contact force ablation catheters and traditional catheters in the treatment of outflow tract premature ventricular complexes. Europace 23(4):596–602CrossRef
9.
go back to reference Dang S, Jons C, Jacobsen PK, Pehrson S, Chen X (2019) Feasibility of a novel mapping system combined with remote magnetic navigation for catheter ablation of premature ventricular contractions. J Arrhythm 35(2):244–251CrossRef Dang S, Jons C, Jacobsen PK, Pehrson S, Chen X (2019) Feasibility of a novel mapping system combined with remote magnetic navigation for catheter ablation of premature ventricular contractions. J Arrhythm 35(2):244–251CrossRef
10.
go back to reference Yoshida N, Yamada T, McElderry HT, Inden Y, Shimano M, Murohara T, Kumar V, Doppalapudi H, Plumb VJ, Kay GN (2014) A novel electrocardiographic criterion for differentiating a left from right ventricular outflow tract tachycardia origin: the V2S/V3R index. J Cardiovasc Electrophysiol 25(7):747–753CrossRef Yoshida N, Yamada T, McElderry HT, Inden Y, Shimano M, Murohara T, Kumar V, Doppalapudi H, Plumb VJ, Kay GN (2014) A novel electrocardiographic criterion for differentiating a left from right ventricular outflow tract tachycardia origin: the V2S/V3R index. J Cardiovasc Electrophysiol 25(7):747–753CrossRef
11.
go back to reference Bourier F, Fahrig R, Wang P, Santangeli P, Kurzidim K, Strobel N, Moore T, Hinkel C, Al-Ahmad A (2014) Accuracy assessment of catheter guidance technology in electrophysiology procedures: a comparison of a new 3D-based fluoroscopy navigation system to current electroanatomic mapping systems. J Cardiovasc Electrophysiol 25(1):74–83CrossRef Bourier F, Fahrig R, Wang P, Santangeli P, Kurzidim K, Strobel N, Moore T, Hinkel C, Al-Ahmad A (2014) Accuracy assessment of catheter guidance technology in electrophysiology procedures: a comparison of a new 3D-based fluoroscopy navigation system to current electroanatomic mapping systems. J Cardiovasc Electrophysiol 25(1):74–83CrossRef
12.
go back to reference Bogun F, Taj M, Ting M, Kim HM, Reich S, Good E, Jongnarangsin K, Chugh A, Pelosi F, Oral H, Morady F (2008) Spatial resolution of pace mapping of idiopathic ventricular tachycardia/ectopy originating in the right ventricular outflow tract. Heart Rhythm 5(3):339–344CrossRef Bogun F, Taj M, Ting M, Kim HM, Reich S, Good E, Jongnarangsin K, Chugh A, Pelosi F, Oral H, Morady F (2008) Spatial resolution of pace mapping of idiopathic ventricular tachycardia/ectopy originating in the right ventricular outflow tract. Heart Rhythm 5(3):339–344CrossRef
13.
go back to reference de Vries LJ, Hendriks AA, Yap SC, Theuns DAMJ, van Domburg RT, Szili-Torok T (2018) Procedural and long-term outcome after catheter ablation of idiopathic outflow tract ventricular arrhythmias: comparing manual, contact force, and magnetic navigated ablation. Europace 20(suppl_2):ii22–ii27CrossRef de Vries LJ, Hendriks AA, Yap SC, Theuns DAMJ, van Domburg RT, Szili-Torok T (2018) Procedural and long-term outcome after catheter ablation of idiopathic outflow tract ventricular arrhythmias: comparing manual, contact force, and magnetic navigated ablation. Europace 20(suppl_2):ii22–ii27CrossRef
Metadata
Title
Selection of an impedance- or magnetic field-based electro-anatomical mapping platform does not affect outcomes of outflow tract premature ventricular complex manual ablation
Authors
Pál Ábrahám
Mercédesz Ambrus
Szilvia Herczeg
Nándor Szegedi
Klaudia Vivien Nagy
Zoltán Salló
Péter Perge
István Osztheimer
Gábor Széplaki
Tamás Tahin
Béla Merkely
László Gellér
Publication date
12-05-2022
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 10/2022
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-022-02081-4

Other articles of this Issue 10/2022

Heart and Vessels 10/2022 Go to the issue