Skip to main content
Top
Published in: Radiation Oncology 1/2012

Open Access 01-12-2012 | Research

Searching standard parameters for volumetric modulated arc therapy (VMAT) of prostate cancer

Authors: Marius Treutwein, Matthias Hipp, Oliver Koelbl, Barbara Dobler

Published in: Radiation Oncology | Issue 1/2012

Login to get access

Abstract

Background

Since December 2009 a new VMAT planning system tool is available in Oncentra® MasterPlan v3.3 (Nucletron B.V.). The purpose of this study was to work out standard parameters for the optimization of prostate cancer.

Methods

For ten patients with localized prostate cancer plans for simultaneous integrated boost were optimized, varying systematically the number of arcs, collimator angle, the maximum delivery time, and the gantry spacing. Homogeneity in clinical target volume, minimum dose in planning target volume, median dose in the organs at risk, maximum dose in the posterior part of the rectum, and number of monitor units were evaluated using student’s test for statistical analysis. Measurements were performed with a 2D-array, taking the delivery time, and compared to the calculation by the gamma method.

Results

Plans with collimator 45° were superior to plans with collimator 0°. Single arc resulted in higher minimum dose in the planning target volume, but also higher dose values to the organs at risk, requiring less monitor units per fraction dose than dual arc. Single arc needs a higher value (per arc) for the maximum delivery time parameter than dual arc, but as only one arc is needed, the measured delivery time was shorter and stayed below 2.5 min versus 3 to 5 min. Balancing plan quality, dosimetric results and calculation time, a gantry spacing of 4° led to optimal results.

Conclusion

A set of parameters has been found which can be used as standard for volumetric modulated arc therapy planning of prostate cancer.
Appendix
Available only for authorised users
Literature
1.
go back to reference Otto K: Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys 2008, 35: 310-317. 10.1118/1.2818738CrossRefPubMed Otto K: Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys 2008, 35: 310-317. 10.1118/1.2818738CrossRefPubMed
2.
go back to reference Adams EJ, Convery DJ, Cosgrove VP, McNair HA, Staffurth JN, Vaarkamp J, Nutting CM, Warrington AP, Webb S, Balyckyi J, Dearnaley DP: Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement. Radiother Oncol 2004, 70: 1-10. 10.1016/j.radonc.2003.09.004CrossRefPubMed Adams EJ, Convery DJ, Cosgrove VP, McNair HA, Staffurth JN, Vaarkamp J, Nutting CM, Warrington AP, Webb S, Balyckyi J, Dearnaley DP: Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement. Radiother Oncol 2004, 70: 1-10. 10.1016/j.radonc.2003.09.004CrossRefPubMed
3.
go back to reference Cahlon O, Hunt M, Zelefsky MJ: Intensity-modulated radiation therapy: supportive data for prostate cancer. Semin Radiat Oncol 2008, 18: 48-57. 10.1016/j.semradonc.2007.09.007CrossRefPubMed Cahlon O, Hunt M, Zelefsky MJ: Intensity-modulated radiation therapy: supportive data for prostate cancer. Semin Radiat Oncol 2008, 18: 48-57. 10.1016/j.semradonc.2007.09.007CrossRefPubMed
4.
go back to reference Guckenberger M, Flentje M: Intensity-modulated radiotherapy (IMRT) of localized prostate cancer. Strahlenther Onkol 2007, 183: 57-62. 10.1007/s00066-007-1631-3CrossRefPubMed Guckenberger M, Flentje M: Intensity-modulated radiotherapy (IMRT) of localized prostate cancer. Strahlenther Onkol 2007, 183: 57-62. 10.1007/s00066-007-1631-3CrossRefPubMed
5.
go back to reference Hysing LB, Skorpen TN, Alber M, Fjellsbø LB, Helle SI, Muren LP: Influence of organ motion on conformal vs. intensity-modulated pelvic radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2008, 71: 1496-1503. 10.1016/j.ijrobp.2008.04.011CrossRefPubMed Hysing LB, Skorpen TN, Alber M, Fjellsbø LB, Helle SI, Muren LP: Influence of organ motion on conformal vs. intensity-modulated pelvic radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2008, 71: 1496-1503. 10.1016/j.ijrobp.2008.04.011CrossRefPubMed
6.
go back to reference Zelefsky MJ, Fuks Z, Hunt M, Yamada Y, Marion C, Ling CC, Amols H, Venkatraman ES, Leibel SA: High-dose intensity modulated radiation therapy for prostate cancer: early toxicity and biochemical outcome in 772 patients. Int J Radiat Oncol Biol Phys 2002, 53: 1111-1116. 10.1016/S0360-3016(02)02857-2CrossRefPubMed Zelefsky MJ, Fuks Z, Hunt M, Yamada Y, Marion C, Ling CC, Amols H, Venkatraman ES, Leibel SA: High-dose intensity modulated radiation therapy for prostate cancer: early toxicity and biochemical outcome in 772 patients. Int J Radiat Oncol Biol Phys 2002, 53: 1111-1116. 10.1016/S0360-3016(02)02857-2CrossRefPubMed
7.
go back to reference Bedford JL: Treatment planning for volumetric modulated arc therapy. Med Phys 2009, 36: 5128-5138. 10.1118/1.3240488CrossRefPubMed Bedford JL: Treatment planning for volumetric modulated arc therapy. Med Phys 2009, 36: 5128-5138. 10.1118/1.3240488CrossRefPubMed
8.
go back to reference Bedford JL, Warrington AP: Commissioning of volumetric modulated arc therapy (VMAT). Int J Radiat Oncol Biol Phys 2009, 73: 537-545. 10.1016/j.ijrobp.2008.08.055CrossRefPubMed Bedford JL, Warrington AP: Commissioning of volumetric modulated arc therapy (VMAT). Int J Radiat Oncol Biol Phys 2009, 73: 537-545. 10.1016/j.ijrobp.2008.08.055CrossRefPubMed
9.
go back to reference Guckenberger M, Richter A, Krieger T, Wilbert J, Baier K, Flentje M: Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes. Radiother Oncol 2009, 93: 259-265. 10.1016/j.radonc.2009.08.015CrossRefPubMed Guckenberger M, Richter A, Krieger T, Wilbert J, Baier K, Flentje M: Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes. Radiother Oncol 2009, 93: 259-265. 10.1016/j.radonc.2009.08.015CrossRefPubMed
10.
go back to reference Matuszak MM, Di Y, Grills I, Martinez A: Clinical applications of volumetric modulated arc therapy. Int J Radiat Oncol Biol Phys 2010, 77: 608-616. 10.1016/j.ijrobp.2009.08.032CrossRefPubMed Matuszak MM, Di Y, Grills I, Martinez A: Clinical applications of volumetric modulated arc therapy. Int J Radiat Oncol Biol Phys 2010, 77: 608-616. 10.1016/j.ijrobp.2009.08.032CrossRefPubMed
11.
go back to reference Crijns W, Budiharto T, Defraene G, Verstraete J, Depuydt T, Haustermans K, van den Heuvel F: IMRT-based optimization approaches for volumetric modulated single arc radiotherapy planning. Radiother Oncol 2010, 95: 149-152. 10.1016/j.radonc.2010.01.012CrossRefPubMed Crijns W, Budiharto T, Defraene G, Verstraete J, Depuydt T, Haustermans K, van den Heuvel F: IMRT-based optimization approaches for volumetric modulated single arc radiotherapy planning. Radiother Oncol 2010, 95: 149-152. 10.1016/j.radonc.2010.01.012CrossRefPubMed
12.
go back to reference Jolly D, Alahakone D, Meyer J: A RapidArc planning strategy for prostate with simultaneous integrated boost. J Appl Clin Med Phys 2011, 12: 35-49. Jolly D, Alahakone D, Meyer J: A RapidArc planning strategy for prostate with simultaneous integrated boost. J Appl Clin Med Phys 2011, 12: 35-49.
13.
go back to reference Kjær-Kristoffersen F, Ohlhues L, Medin J, Korreman S: RapidArc volumetric modulated therapy planning for prostate cancer patients. Acta Oncol 2009, 48: 227-232. 10.1080/02841860802266748CrossRefPubMed Kjær-Kristoffersen F, Ohlhues L, Medin J, Korreman S: RapidArc volumetric modulated therapy planning for prostate cancer patients. Acta Oncol 2009, 48: 227-232. 10.1080/02841860802266748CrossRefPubMed
14.
go back to reference Palma D, Vollans E, James K, Nakano S, Moiseenko V, Shaffer R, McKenzie M, Morris J, Otto K: Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72: 996-1001. 10.1016/j.ijrobp.2008.02.047CrossRefPubMed Palma D, Vollans E, James K, Nakano S, Moiseenko V, Shaffer R, McKenzie M, Morris J, Otto K: Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72: 996-1001. 10.1016/j.ijrobp.2008.02.047CrossRefPubMed
15.
go back to reference Zhang P, Happersett L, Hunt M, Jackson A, Zelefsky MJ, Mageras G: Volumetric modulated arc therapy: planning and evaluation for prostate cancer cases. Int J Radiat Oncol Biol Phys 2010, 76: 1456-1462. 10.1016/j.ijrobp.2009.03.033CrossRefPubMed Zhang P, Happersett L, Hunt M, Jackson A, Zelefsky MJ, Mageras G: Volumetric modulated arc therapy: planning and evaluation for prostate cancer cases. Int J Radiat Oncol Biol Phys 2010, 76: 1456-1462. 10.1016/j.ijrobp.2009.03.033CrossRefPubMed
16.
go back to reference Otto K: Letter to the Editor on ‘Single-Arc IMRT?’. Phys Med Biol 2009, 54: L37-L41. 10.1088/0031-9155/54/8/L03CrossRefPubMed Otto K: Letter to the Editor on ‘Single-Arc IMRT?’. Phys Med Biol 2009, 54: L37-L41. 10.1088/0031-9155/54/8/L03CrossRefPubMed
17.
go back to reference Palma DA, Verbakel WF, Otto K, Senan S: New developments in arc radiation therapy: a review. Cancer Treat Rev 2010, 36: 393-399. 10.1016/j.ctrv.2010.01.004CrossRefPubMed Palma DA, Verbakel WF, Otto K, Senan S: New developments in arc radiation therapy: a review. Cancer Treat Rev 2010, 36: 393-399. 10.1016/j.ctrv.2010.01.004CrossRefPubMed
18.
go back to reference Alvarez-Moret J, Pohl F, Koelbl O, Dobler B: Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer. Radiat Oncol 2010, 5: 110. 10.1186/1748-717X-5-110PubMedCentralCrossRefPubMed Alvarez-Moret J, Pohl F, Koelbl O, Dobler B: Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer. Radiat Oncol 2010, 5: 110. 10.1186/1748-717X-5-110PubMedCentralCrossRefPubMed
19.
go back to reference Dobler B, Weidner K, Koelbl O: Application of volumetric modulated arc therapy (VMAT) in a dual-vendor environment. Radiat Oncol 2010, 5: 95. 10.1186/1748-717X-5-95PubMedCentralCrossRefPubMed Dobler B, Weidner K, Koelbl O: Application of volumetric modulated arc therapy (VMAT) in a dual-vendor environment. Radiat Oncol 2010, 5: 95. 10.1186/1748-717X-5-95PubMedCentralCrossRefPubMed
20.
go back to reference Boehmer D, Maingon P, Poortmans P, Baron M, Raymond M, Vincent R, Christopher S, Bossi A, Bolla M: Guidelines for primary radiotherapy of patients with prostate cancer. Radiother Oncol 2006, 79: 259-269. 10.1016/j.radonc.2006.05.012CrossRefPubMed Boehmer D, Maingon P, Poortmans P, Baron M, Raymond M, Vincent R, Christopher S, Bossi A, Bolla M: Guidelines for primary radiotherapy of patients with prostate cancer. Radiother Oncol 2006, 79: 259-269. 10.1016/j.radonc.2006.05.012CrossRefPubMed
21.
go back to reference Bos LJ, Damen EMF, de Boer RW, Mijnheer BJ, McShan Daniel L, Fraass Benedick A, Kessler Marc L, Lebesque JV: Reduction of rectal dose by integration of the boost in the large-field treatment plan for prostate irradiation. Int J Radiat Oncol Biol Phys 2002, 52: 254-265. 10.1016/S0360-3016(01)02676-1CrossRefPubMed Bos LJ, Damen EMF, de Boer RW, Mijnheer BJ, McShan Daniel L, Fraass Benedick A, Kessler Marc L, Lebesque JV: Reduction of rectal dose by integration of the boost in the large-field treatment plan for prostate irradiation. Int J Radiat Oncol Biol Phys 2002, 52: 254-265. 10.1016/S0360-3016(01)02676-1CrossRefPubMed
22.
go back to reference Guckenberger M, Pohl F, Baier K, Meyer J, Koelbl O, Flentje M, Vordermark D: Influence of rectum delineation (Rectal Volume vs. Rectal Wall) on IMRT treatment planning of the prostate. Strahlenther Onkol 2006, 182: 721-726. 10.1007/s00066-006-1566-0CrossRefPubMed Guckenberger M, Pohl F, Baier K, Meyer J, Koelbl O, Flentje M, Vordermark D: Influence of rectum delineation (Rectal Volume vs. Rectal Wall) on IMRT treatment planning of the prostate. Strahlenther Onkol 2006, 182: 721-726. 10.1007/s00066-006-1566-0CrossRefPubMed
23.
go back to reference Rangaraj D, Oddiraju S, Sun B, Santanam L, Yang D, Goddu S, Papiez L: Fundamental properties of the delivery of volumetric modulated arc therapy (VMAT) to static patient anatomy. Med Phys 2010, 37: 4056-4067. 10.1118/1.3453575CrossRefPubMed Rangaraj D, Oddiraju S, Sun B, Santanam L, Yang D, Goddu S, Papiez L: Fundamental properties of the delivery of volumetric modulated arc therapy (VMAT) to static patient anatomy. Med Phys 2010, 37: 4056-4067. 10.1118/1.3453575CrossRefPubMed
24.
go back to reference Dobler B, Groeger C, Treutwein M, Alvarez-Moret J, Goetzfried T, Weidner K, Haertl P, Koelbl O: Commissioning of volumetric modulated arc therapy (VMAT) in a dual-vendor environment. Radiother Oncol 2011, 99: 86-89. 10.1016/j.radonc.2011.01.024CrossRefPubMed Dobler B, Groeger C, Treutwein M, Alvarez-Moret J, Goetzfried T, Weidner K, Haertl P, Koelbl O: Commissioning of volumetric modulated arc therapy (VMAT) in a dual-vendor environment. Radiother Oncol 2011, 99: 86-89. 10.1016/j.radonc.2011.01.024CrossRefPubMed
25.
go back to reference Bzdusek K, Friberger H, Eriksson K, Hardemark B, Robinson D, Kaus M: Development and evaluation of an efficient approach to volumetric arc therapy planning. Med Phys 2009, 36: 2328-2339. 10.1118/1.3132234CrossRefPubMed Bzdusek K, Friberger H, Eriksson K, Hardemark B, Robinson D, Kaus M: Development and evaluation of an efficient approach to volumetric arc therapy planning. Med Phys 2009, 36: 2328-2339. 10.1118/1.3132234CrossRefPubMed
26.
go back to reference Eriksson K, Friberger H, Sterner E, Blumenthal C: Volumetric Modulated Arc Therapy (VMAT) optimization with RayArc. RaySearch White Paper, Stockholm; 2009:1-16. Eriksson K, Friberger H, Sterner E, Blumenthal C: Volumetric Modulated Arc Therapy (VMAT) optimization with RayArc. RaySearch White Paper, Stockholm; 2009:1-16.
27.
go back to reference Treutwein M, Hipp M, Kölbl O, Bogner L: IMRT of prostate cancer. Strahlenther Onkol 2009, 185: 379-383. 10.1007/s00066-009-1950-7CrossRefPubMed Treutwein M, Hipp M, Kölbl O, Bogner L: IMRT of prostate cancer. Strahlenther Onkol 2009, 185: 379-383. 10.1007/s00066-009-1950-7CrossRefPubMed
28.
go back to reference Dobler B, Koelbl O, Bogner L, Pohl F: Direct machine parameter optimization for intensity modulated radiation therapy (IMRT) of oropharyngeal cancer—a planning study. J Appl Clin Med Phys 2009, 10: 4-15.CrossRef Dobler B, Koelbl O, Bogner L, Pohl F: Direct machine parameter optimization for intensity modulated radiation therapy (IMRT) of oropharyngeal cancer—a planning study. J Appl Clin Med Phys 2009, 10: 4-15.CrossRef
29.
go back to reference Bortfeld T: The number of beams in IMRT—theoretical investigations and implications for single-arc IMRT. Phys Med Biol 2010, 55: 83-97. 10.1088/0031-9155/55/1/006PubMedCentralCrossRefPubMed Bortfeld T: The number of beams in IMRT—theoretical investigations and implications for single-arc IMRT. Phys Med Biol 2010, 55: 83-97. 10.1088/0031-9155/55/1/006PubMedCentralCrossRefPubMed
30.
31.
go back to reference Oliver M, Gagne I, Popescu C, Ansbacher W, Beckham WA: Analysis of RapidArc optimization strategies using objective function values and dose-volume histograms. J Appl Clin Med Phys 2010, 11: 10-23. Oliver M, Gagne I, Popescu C, Ansbacher W, Beckham WA: Analysis of RapidArc optimization strategies using objective function values and dose-volume histograms. J Appl Clin Med Phys 2010, 11: 10-23.
32.
go back to reference Feygelman V, Zhang G, Stevens C: Initial dosimetric evaluation of SmartArc—a novel VMAT treatment planning module implemented in a multi-vendor delivery chain. J Appl Clin Med Phys 2010, 11: 99-116. Feygelman V, Zhang G, Stevens C: Initial dosimetric evaluation of SmartArc—a novel VMAT treatment planning module implemented in a multi-vendor delivery chain. J Appl Clin Med Phys 2010, 11: 99-116.
33.
go back to reference Georg D, Kroupa B, Georg P, Winkler P, Bogner J, Dieckmann K, Pötter R: Inverse planning—a comparative intersystem and interpatient constraint study. Strahlenther Onkol 2006, 182: 473-480. 10.1007/s00066-006-1531-yCrossRefPubMed Georg D, Kroupa B, Georg P, Winkler P, Bogner J, Dieckmann K, Pötter R: Inverse planning—a comparative intersystem and interpatient constraint study. Strahlenther Onkol 2006, 182: 473-480. 10.1007/s00066-006-1531-yCrossRefPubMed
34.
go back to reference Mock U, Bogner J, Georg D, Auberger T, Pötter R: Comparative treatment planning on localized prostate carcinoma. Strahlenther Onkol 2005, 181: 448-455. 10.1007/s00066-005-1317-7CrossRefPubMed Mock U, Bogner J, Georg D, Auberger T, Pötter R: Comparative treatment planning on localized prostate carcinoma. Strahlenther Onkol 2005, 181: 448-455. 10.1007/s00066-005-1317-7CrossRefPubMed
35.
go back to reference Dobler B, Streck N, Klein E, Loeschel R, Haertl P, Koelbl O: Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I’mRT MatriXX—a feasability study. Phys Med Biol 2010, 55: N39-N55. 10.1088/0031-9155/55/2/N02CrossRefPubMed Dobler B, Streck N, Klein E, Loeschel R, Haertl P, Koelbl O: Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I’mRT MatriXX—a feasability study. Phys Med Biol 2010, 55: N39-N55. 10.1088/0031-9155/55/2/N02CrossRefPubMed
36.
go back to reference Wolfsberger LD, Wagar M, Nitsch P, Bhagwat MS, Zygmanski P: Angular dose dependence of Matrixx TM and its calibration. J Appl Clin Med Phys 2010, 11: 241-251. Wolfsberger LD, Wagar M, Nitsch P, Bhagwat MS, Zygmanski P: Angular dose dependence of Matrixx TM and its calibration. J Appl Clin Med Phys 2010, 11: 241-251.
37.
go back to reference Low DA, Harms WB, Mutic S, Purdy JA: A technique for the quantitative evaluation of dose distributions. Med Phys 1998, 25: 656-661. 10.1118/1.598248CrossRefPubMed Low DA, Harms WB, Mutic S, Purdy JA: A technique for the quantitative evaluation of dose distributions. Med Phys 1998, 25: 656-661. 10.1118/1.598248CrossRefPubMed
38.
go back to reference Ezzell GA, Burmeister JW, Dogan N, LoSasso TJ, Mechalakos JG, Mihailidis D, Molineu A, Palta JR, Ramsey CR, Salter BJ, Shi J, Xia P, Yue NJ, Xiao Y: IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 2009, 36: 5359-5373. 10.1118/1.3238104CrossRefPubMed Ezzell GA, Burmeister JW, Dogan N, LoSasso TJ, Mechalakos JG, Mihailidis D, Molineu A, Palta JR, Ramsey CR, Salter BJ, Shi J, Xia P, Yue NJ, Xiao Y: IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 2009, 36: 5359-5373. 10.1118/1.3238104CrossRefPubMed
39.
go back to reference Ghilezan MJ, Jaffray DA, Siewerdsen JH, van Herk M, Shetty A, Sharpe MB, Jafri SZ, Vicini FA, Matter RC, Brabbins DS, Martinez AA: Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). Int J Radiat Oncol Biol Phys 2005, 62: 406-417. 10.1016/j.ijrobp.2003.10.017CrossRefPubMed Ghilezan MJ, Jaffray DA, Siewerdsen JH, van Herk M, Shetty A, Sharpe MB, Jafri SZ, Vicini FA, Matter RC, Brabbins DS, Martinez AA: Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). Int J Radiat Oncol Biol Phys 2005, 62: 406-417. 10.1016/j.ijrobp.2003.10.017CrossRefPubMed
40.
go back to reference Nederveen AJ, van der Heide UA, Dehnad H, Van Moorselaar Jeroen A, Hofman P, Lagendijk JJW: Measurements and clinical consequences of prostate motion during a radiotherapy fraction. Int J Radiat Oncol Biol Phys 2002, 53: 206-214. 10.1016/S0360-3016(01)02823-1CrossRefPubMed Nederveen AJ, van der Heide UA, Dehnad H, Van Moorselaar Jeroen A, Hofman P, Lagendijk JJW: Measurements and clinical consequences of prostate motion during a radiotherapy fraction. Int J Radiat Oncol Biol Phys 2002, 53: 206-214. 10.1016/S0360-3016(01)02823-1CrossRefPubMed
41.
go back to reference Kupelian P, Meyer JL: Image-guided, adaptive radiotherapy of prostate cancer: toward new standards of radiotherapy practice. Front Radiat Ther Oncol 2011, 43: 344-368.CrossRefPubMed Kupelian P, Meyer JL: Image-guided, adaptive radiotherapy of prostate cancer: toward new standards of radiotherapy practice. Front Radiat Ther Oncol 2011, 43: 344-368.CrossRefPubMed
42.
go back to reference Webb S, McQuaid D: Some considerations concerning volume-modulated arc therapy: a stepping stone towards a general theory. Phys Med Biol 2009, 54: 4345-4360. 10.1088/0031-9155/54/14/001CrossRefPubMed Webb S, McQuaid D: Some considerations concerning volume-modulated arc therapy: a stepping stone towards a general theory. Phys Med Biol 2009, 54: 4345-4360. 10.1088/0031-9155/54/14/001CrossRefPubMed
43.
go back to reference Fogliata A, Nicolini G, Alber M, Asell M, Dobler B, El-Haddad M, Hardemark B, Jelen U, Kania A, Larsson M, Lohr F, Munger T, Negri E, Rodrigues C, Cozzi L: IMRT for breast. A planning study. Radiother Oncol 2005, 76: 300-310. 10.1016/j.radonc.2005.08.004CrossRefPubMed Fogliata A, Nicolini G, Alber M, Asell M, Dobler B, El-Haddad M, Hardemark B, Jelen U, Kania A, Larsson M, Lohr F, Munger T, Negri E, Rodrigues C, Cozzi L: IMRT for breast. A planning study. Radiother Oncol 2005, 76: 300-310. 10.1016/j.radonc.2005.08.004CrossRefPubMed
44.
go back to reference Dobler B, Pohl F, Bogner L, Koelbl O: Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma. Radiat Oncol 2007, 2: 33. 10.1186/1748-717X-2-33PubMedCentralCrossRefPubMed Dobler B, Pohl F, Bogner L, Koelbl O: Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma. Radiat Oncol 2007, 2: 33. 10.1186/1748-717X-2-33PubMedCentralCrossRefPubMed
45.
go back to reference Webb S: Does the option to rotate the Elekta Beam Modulator MLC during VMAT IMRT delivery confer advantage?—a study of ‘parked gaps’. Phys Med Biol 2010, 55: N303-N319. 10.1088/0031-9155/55/11/N01CrossRefPubMed Webb S: Does the option to rotate the Elekta Beam Modulator MLC during VMAT IMRT delivery confer advantage?—a study of ‘parked gaps’. Phys Med Biol 2010, 55: N303-N319. 10.1088/0031-9155/55/11/N01CrossRefPubMed
Metadata
Title
Searching standard parameters for volumetric modulated arc therapy (VMAT) of prostate cancer
Authors
Marius Treutwein
Matthias Hipp
Oliver Koelbl
Barbara Dobler
Publication date
01-12-2012
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2012
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-7-108

Other articles of this Issue 1/2012

Radiation Oncology 1/2012 Go to the issue