Skip to main content
Top
Published in: Digestive Diseases and Sciences 11/2016

01-11-2016 | Original Article

Safety and Efficacy of a Same-Day Low-Volume 1 L PEG Bowel Preparation in Colonoscopy for the Elderly People and People with Renal Dysfunction

Authors: Naohisa Yoshida, Yuji Naito, Takaaki Murakami, Ryohei Hirose, Kiyoshi Ogiso, Yutaka Inada, Osamu Dohi, Tetsuya Okayama, Kazuhiro Kamada, Kazuhiko Uchiyama, Takeshi Ishikawa, Osamu Handa, Hideyuki Konishi, Kewin Tien Ho Siah, Nobuaki Yagi, Yoshito Itoh

Published in: Digestive Diseases and Sciences | Issue 11/2016

Login to get access

Abstract

Introduction

A same-day low-volume 1 L polyethylene glycol (PEG) for bowel preparation before colonoscopy was developed to improve patients’ compliance. We aimed to evaluate the efficacy and safety of this regimen especially for the elderly and patients with renal dysfunction.

Methods

All consecutive patients who underwent colonoscopy in our center from November 2014 to September 2015 were included. Patients undertook a low-residue diet with 10 mL sodium picosulfate 1 day before colonoscopy. Subsequently, they had 1 L low-volume PEG (MoviPrep) and 0.5 L water 4 h before the examination. Clinical outcomes, including cleansing level using the Boston bowel preparation score (BBPS), in the elderly and special-elderly (65–79 and ≥80 years old) were analyzed and compared with the non-elderly (18–64 years old). Additionally, patients with renal dysfunction were analyzed with respect to both complications and changes in blood parameters.

Results

A total of 5427 patients (mean age: 64.5 ± 13.8) were analyzed. The rate of BBPS ≥ 6 in the elderly (2761 patients), special-elderly (565 patients), and non-elderly (2101 patients) was 94.1, 91.8, and 94.6 %, respectively. In the special-elderly, the rate of renal dysfunction was 14.8 %, and no severe complications were detected after colonoscopy. Additionally, there were no severe complications in 86 patients with renal dysfunction, though elevation of hematocrit was shown after intake of 1 L PEG (before, 36.7 ± 6.1 vs. after, 39.0 ± 5.7, P = 0.006).

Conclusions

Our study shows the safety and efficacy of same-day low-volume 1 L PEG bowel preparation in colonoscopy for the elderly and patients with renal dysfunction.
Literature
1.
go back to reference Zauber AG, Winawer SJ, O’Brien MJ, et al. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med. 2012;366:687–696.CrossRefPubMedPubMedCentral Zauber AG, Winawer SJ, O’Brien MJ, et al. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med. 2012;366:687–696.CrossRefPubMedPubMedCentral
2.
go back to reference Yoshida N, Wakabayashi N, Kanemasa K, et al. Endoscopic submucosal dissection for colorectal tumors: technical difficulties and rate of perforation. Endoscopy. 2009;41:758–761.CrossRefPubMed Yoshida N, Wakabayashi N, Kanemasa K, et al. Endoscopic submucosal dissection for colorectal tumors: technical difficulties and rate of perforation. Endoscopy. 2009;41:758–761.CrossRefPubMed
3.
go back to reference Tanaka S, Oka S, Kaneko I, et al. Endoscopic submucosal dissection for colorectal neoplasia: possibility of standardization. Gastrointest Endosc. 2007;66:100–107.CrossRefPubMed Tanaka S, Oka S, Kaneko I, et al. Endoscopic submucosal dissection for colorectal neoplasia: possibility of standardization. Gastrointest Endosc. 2007;66:100–107.CrossRefPubMed
4.
go back to reference Saito Y, Uraoka T, Yamaguchi Y, et al. A prospective, multicenter study of 1111 colorectal endoscopic submucosal dissections (with video). Gastrointest Endosc. 2010;72:1217–1225.CrossRefPubMed Saito Y, Uraoka T, Yamaguchi Y, et al. A prospective, multicenter study of 1111 colorectal endoscopic submucosal dissections (with video). Gastrointest Endosc. 2010;72:1217–1225.CrossRefPubMed
5.
go back to reference Horiuchi A, Nakayama Y, Kajiyama M, et al. Removal of small colorectal polyps in anticoagulated patients: a prospective randomized comparison of cold snare and conventional polypectomy. Gastrointest Endosc. 2014;79:417–423.CrossRefPubMed Horiuchi A, Nakayama Y, Kajiyama M, et al. Removal of small colorectal polyps in anticoagulated patients: a prospective randomized comparison of cold snare and conventional polypectomy. Gastrointest Endosc. 2014;79:417–423.CrossRefPubMed
6.
go back to reference Yoshida N, Naito Y, Kugai M, et al. Efficacy of hyaluronic acid in endoscopic mucosal resection for colorectal tumors. J Gastroenterol Hepatol. 2011;26:286–291.CrossRefPubMed Yoshida N, Naito Y, Kugai M, et al. Efficacy of hyaluronic acid in endoscopic mucosal resection for colorectal tumors. J Gastroenterol Hepatol. 2011;26:286–291.CrossRefPubMed
7.
go back to reference Yoshida N, Yagi N, Naito Y, Yoshikawa T. Safe procedure in endoscopic submucosal dissection for colorectal tumors focused on preventing complications. World J Gastroenterol. 2010;16:1688–1695.CrossRefPubMedPubMedCentral Yoshida N, Yagi N, Naito Y, Yoshikawa T. Safe procedure in endoscopic submucosal dissection for colorectal tumors focused on preventing complications. World J Gastroenterol. 2010;16:1688–1695.CrossRefPubMedPubMedCentral
8.
go back to reference Froehlich F, Wietlisbach V, Gonvers JJ, et al. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European Multicenter Study. Gastrointest Endosc. 2005;6:378–384.CrossRef Froehlich F, Wietlisbach V, Gonvers JJ, et al. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European Multicenter Study. Gastrointest Endosc. 2005;6:378–384.CrossRef
9.
go back to reference Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc. 2003;58:76–79.CrossRefPubMed Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc. 2003;58:76–79.CrossRefPubMed
10.
go back to reference Johnson DA, Barkun AN, Cohen LB, et al. Optimizing adequacy of bowel cleansing for colonoscopy: recommendations from the US multi-society task force on colorectal cancer. Gastroenterology. 2014;147:903–924.CrossRefPubMed Johnson DA, Barkun AN, Cohen LB, et al. Optimizing adequacy of bowel cleansing for colonoscopy: recommendations from the US multi-society task force on colorectal cancer. Gastroenterology. 2014;147:903–924.CrossRefPubMed
11.
go back to reference Corporaal S, Kleibeuker JH, Koornstra JJ. Low-volume PEG plus ascorbic acid versus high-volume PEG as bowel preparation for colonoscopy. Scand J Gastroenterol. 2010;45:1380–1386.CrossRefPubMed Corporaal S, Kleibeuker JH, Koornstra JJ. Low-volume PEG plus ascorbic acid versus high-volume PEG as bowel preparation for colonoscopy. Scand J Gastroenterol. 2010;45:1380–1386.CrossRefPubMed
12.
go back to reference Gentile M, De Rosa M, Cestaro G, Forestieri P. 2 L PEG plus ascorbic acid versus 4 L PEG plus simethicone for colonoscopy preparation: a randomized single-blind clinical trial. Surg Laparosc Endosc Percutan Tech. 2013;23:276–280.CrossRefPubMed Gentile M, De Rosa M, Cestaro G, Forestieri P. 2 L PEG plus ascorbic acid versus 4 L PEG plus simethicone for colonoscopy preparation: a randomized single-blind clinical trial. Surg Laparosc Endosc Percutan Tech. 2013;23:276–280.CrossRefPubMed
13.
go back to reference Mathus-Vliegen EM, van der Vliet K. Safety, patient’s tolerance, and efficacy of a 2-liter vitamin C-enriched macrogol bowel preparation: a randomized, endoscopist-blinded prospective comparison with a 4-liter macrogol solution. Dis Colon Rectum. 2013;56:1002–1012.CrossRefPubMed Mathus-Vliegen EM, van der Vliet K. Safety, patient’s tolerance, and efficacy of a 2-liter vitamin C-enriched macrogol bowel preparation: a randomized, endoscopist-blinded prospective comparison with a 4-liter macrogol solution. Dis Colon Rectum. 2013;56:1002–1012.CrossRefPubMed
14.
go back to reference Ponchon T, Boustière C, Heresbach D, et al. A low-volume polyethylene glycol plus ascorbate solution for bowel cleansing prior to colonoscopy: the NORMO randomised clinical trial. Dig Liver Dis. 2013;45:820–826.CrossRefPubMed Ponchon T, Boustière C, Heresbach D, et al. A low-volume polyethylene glycol plus ascorbate solution for bowel cleansing prior to colonoscopy: the NORMO randomised clinical trial. Dig Liver Dis. 2013;45:820–826.CrossRefPubMed
15.
go back to reference Pontone S, Angelini R, Standoli M, et al. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy. World J Gastroenterol. 2011;17:4689–4695.CrossRefPubMedPubMedCentral Pontone S, Angelini R, Standoli M, et al. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy. World J Gastroenterol. 2011;17:4689–4695.CrossRefPubMedPubMedCentral
16.
go back to reference Tajika M, Tanaka T, Ishihara M, et al. A randomized controlled trial evaluating a low-volume PEG solution plus ascorbic acid versus standard PEG solution in bowel preparation for colonoscopy. Gastroenterol Res Pract. 2015;2015:326581.CrossRefPubMedPubMedCentral Tajika M, Tanaka T, Ishihara M, et al. A randomized controlled trial evaluating a low-volume PEG solution plus ascorbic acid versus standard PEG solution in bowel preparation for colonoscopy. Gastroenterol Res Pract. 2015;2015:326581.CrossRefPubMedPubMedCentral
17.
go back to reference Lai EJ, Calderwood AH, Doros G, et al. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc. 2009;69:620–625.CrossRefPubMedPubMedCentral Lai EJ, Calderwood AH, Doros G, et al. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc. 2009;69:620–625.CrossRefPubMedPubMedCentral
18.
go back to reference Valiante F, Pontone S, Hassan C, et al. A randomized controlled trial evaluating a new 2-L PEG solution plus ascorbic acid vs 4-L PEG for bowel cleansing prior to colonoscopy. Dig Liver Dis. 2012;44:224–227.CrossRefPubMed Valiante F, Pontone S, Hassan C, et al. A randomized controlled trial evaluating a new 2-L PEG solution plus ascorbic acid vs 4-L PEG for bowel cleansing prior to colonoscopy. Dig Liver Dis. 2012;44:224–227.CrossRefPubMed
19.
go back to reference Seo EH, Kim TO, Park MJ, et al. Low-volume morning-only polyethylene glycol with specially designed test meals versus standard-volume split-dose polyethylene glycol with standard diet for colonoscopy: a prospective, randomized trial. Digestion. 2013;88:110–118.CrossRefPubMed Seo EH, Kim TO, Park MJ, et al. Low-volume morning-only polyethylene glycol with specially designed test meals versus standard-volume split-dose polyethylene glycol with standard diet for colonoscopy: a prospective, randomized trial. Digestion. 2013;88:110–118.CrossRefPubMed
20.
go back to reference Hookey LC, Depew WT, Vanner SJ. Combined low volume polyethylene glycol solution plus stimulant laxatives versus standard volume polyethylene glycol solution: a prospective, randomized study of colon cleansing before colonoscopy. Can J Gastroenterol. 2006;20:101–105.CrossRefPubMedPubMedCentral Hookey LC, Depew WT, Vanner SJ. Combined low volume polyethylene glycol solution plus stimulant laxatives versus standard volume polyethylene glycol solution: a prospective, randomized study of colon cleansing before colonoscopy. Can J Gastroenterol. 2006;20:101–105.CrossRefPubMedPubMedCentral
21.
go back to reference Hassan C, Fuccio L, Bruno M, et al. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol. 2012;10:501–506.CrossRefPubMed Hassan C, Fuccio L, Bruno M, et al. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol. 2012;10:501–506.CrossRefPubMed
22.
go back to reference Lebwohl B, Wang TC, Neugut AI. Socioeconomic and other predictors of colonoscopy preparation quality. Dig Dis Sci. 2010;55:2014–2020.CrossRefPubMed Lebwohl B, Wang TC, Neugut AI. Socioeconomic and other predictors of colonoscopy preparation quality. Dig Dis Sci. 2010;55:2014–2020.CrossRefPubMed
23.
go back to reference Ness RM, Manam R, Hoen H, Chalasani N. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol. 2001;96:1797–1802.CrossRefPubMed Ness RM, Manam R, Hoen H, Chalasani N. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol. 2001;96:1797–1802.CrossRefPubMed
24.
25.
go back to reference Taylor C, Schubert ML. Decreased efficacy of polyethylene glycol lavage solution (golytely) in the preparation of diabetic patients for outpatient colonoscopy: a prospective and blinded study. Am J Gastroenterol. 2001;96:710–714.CrossRefPubMed Taylor C, Schubert ML. Decreased efficacy of polyethylene glycol lavage solution (golytely) in the preparation of diabetic patients for outpatient colonoscopy: a prospective and blinded study. Am J Gastroenterol. 2001;96:710–714.CrossRefPubMed
26.
go back to reference Lim SW, Seo YW, Sinn DH, et al. Impact of previous gastric or colonic resection on polyethylene glycol bowel preparation for colonoscopy. Surg Endosc. 2012;26:1554–1559.CrossRefPubMed Lim SW, Seo YW, Sinn DH, et al. Impact of previous gastric or colonic resection on polyethylene glycol bowel preparation for colonoscopy. Surg Endosc. 2012;26:1554–1559.CrossRefPubMed
27.
go back to reference Chokshi RV, Hovis CE, Hollander T, et al. Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy. Gastrointest Endosc. 2012;75:1197–1203.CrossRefPubMed Chokshi RV, Hovis CE, Hollander T, et al. Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy. Gastrointest Endosc. 2012;75:1197–1203.CrossRefPubMed
28.
go back to reference Horimatsu T, Sano Y, Tanaka S, et al. Next-generation narrow band imaging system for colonic polyp detection: a prospective multicenter randomized trial. Int J Colorectal Dis. 2015;30:947–954.CrossRefPubMed Horimatsu T, Sano Y, Tanaka S, et al. Next-generation narrow band imaging system for colonic polyp detection: a prospective multicenter randomized trial. Int J Colorectal Dis. 2015;30:947–954.CrossRefPubMed
29.
go back to reference Yoshida N, Hisabe T, Hirose R, et al. 2015) Improvement in the visibility of colorectal polyps by using blue laser imaging (with video. Gastrointest Endosc. 2015;82:542–549.CrossRefPubMed Yoshida N, Hisabe T, Hirose R, et al. 2015) Improvement in the visibility of colorectal polyps by using blue laser imaging (with video. Gastrointest Endosc. 2015;82:542–549.CrossRefPubMed
Metadata
Title
Safety and Efficacy of a Same-Day Low-Volume 1 L PEG Bowel Preparation in Colonoscopy for the Elderly People and People with Renal Dysfunction
Authors
Naohisa Yoshida
Yuji Naito
Takaaki Murakami
Ryohei Hirose
Kiyoshi Ogiso
Yutaka Inada
Osamu Dohi
Tetsuya Okayama
Kazuhiro Kamada
Kazuhiko Uchiyama
Takeshi Ishikawa
Osamu Handa
Hideyuki Konishi
Kewin Tien Ho Siah
Nobuaki Yagi
Yoshito Itoh
Publication date
01-11-2016
Publisher
Springer US
Published in
Digestive Diseases and Sciences / Issue 11/2016
Print ISSN: 0163-2116
Electronic ISSN: 1573-2568
DOI
https://doi.org/10.1007/s10620-016-4262-7

Other articles of this Issue 11/2016

Digestive Diseases and Sciences 11/2016 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.