Excerpt

The authors state in the title, as well as in the methods, that the investigation measured muscle mass. However, muscle mass was never measured, only lean mass. Using the equipment cited in the methods (DXA, Hologic QDR-1500), it is impossible to directly measure muscle mass without a prediction equation; only bone, fat, and lean mass can be measured. The authors state, “Lower limb lean mass (kg) was calculated from the regional analysis of the whole body scan and it has been considered equivalent to the lower limb muscle mass”; however, lean mass and muscle mass are not equivalent and should not be used synonymously. There is a distinct difference between lean mass and muscle mass. Muscle mass is a measurement of only muscle tissue, while lean mass includes muscle and all other tissues except bone and fat. Therefore, lean mass includes skin, tendons, and connective tissue. This alone suggests that muscle mass cannot be equivalent to lean mass and should not be referred to in the manuscript or, more importantly, in the title. The use of the term “muscle mass” in the title is misleading and inaccurate since muscle mass was not measured. There are several published studies that demonstrate accurate methods to estimate whole body and segmental muscle mass (Kim et al. 2002; Fuller et al. 1992; Shih et al. 2000; Visser et al. 1999; Levine et al. 2000; Heymsfield et al. 1990; Wang et al. 1996). The fact that these methods were not utilized in the current investigation is a concern; however, changing the “lower limb muscle mass” values to “lower limb lean mass” values would be sufficient to correct the error. Furthermore, the authors fail to reference their statement regarding the equivalence between muscle mass and lean mass, yet, if the authors can provide a reference that justifies this statement, then it will be less of a concern. Additionally, the studies mentioned under the References section (Kim et al. 2002; Fuller et al. 1992; Shih et al. 2000; Visser et al. 1999; Levine et al. 2000; Heymsfield et al. 1990; Wang et al. 1996) provide further detailed information regarding muscle mass and measurement methods. I hope this information can be of some assistance, and I appreciate your attention to detail. …
Literature
go back to reference Kim J, Wang Z, Heymsfield SB, Baumgartner RN, Gallagher D (2002) Total-body skeletal muscle mass: estimation by a new dual-energy X-ray absorptiometry method. Am J Clin Nutr 76:378–383PubMed Kim J, Wang Z, Heymsfield SB, Baumgartner RN, Gallagher D (2002) Total-body skeletal muscle mass: estimation by a new dual-energy X-ray absorptiometry method. Am J Clin Nutr 76:378–383PubMed
go back to reference Fuller NJ, Laskey MA, Elia M (1992) Assessment of the composition of major body regions by dual-energy X-ray absorptiometry (DEXA), with special reference to limb muscle mass. Clin Physiol 12:253–266PubMedCrossRef Fuller NJ, Laskey MA, Elia M (1992) Assessment of the composition of major body regions by dual-energy X-ray absorptiometry (DEXA), with special reference to limb muscle mass. Clin Physiol 12:253–266PubMedCrossRef
go back to reference Shih R, Wang Z, Heo M, Wang W, Heymsfield SB (2000) Lower limb skeletal muscle mass: development of dual-energy X-ray absorptiometry prediction model. J Appl Physiol 89:1380–1386PubMed Shih R, Wang Z, Heo M, Wang W, Heymsfield SB (2000) Lower limb skeletal muscle mass: development of dual-energy X-ray absorptiometry prediction model. J Appl Physiol 89:1380–1386PubMed
go back to reference Visser M, Fuerst T, Lang T, Salamone L, Harris TB (1999) Validity of fanbeam dual-energy X-ray absorptiometry for measuring fat-free mass and leg muscle mass. J Appl Physiol 87:1513–1520PubMed Visser M, Fuerst T, Lang T, Salamone L, Harris TB (1999) Validity of fanbeam dual-energy X-ray absorptiometry for measuring fat-free mass and leg muscle mass. J Appl Physiol 87:1513–1520PubMed
go back to reference Levine JA, Abboud L, Barry M, Judd ER, Sheedy PF, Jensen MD (2000) Measuring leg muscle and fat mass in humans: comparison of CT and dual-energy X-ray absorptiometry. J Appl Physiol 88:452–456PubMed Levine JA, Abboud L, Barry M, Judd ER, Sheedy PF, Jensen MD (2000) Measuring leg muscle and fat mass in humans: comparison of CT and dual-energy X-ray absorptiometry. J Appl Physiol 88:452–456PubMed
go back to reference Heymsfield SB, Smith R, Aulet M et al (1990) Appendicular skeletal muscle mass: measurement by dual-photon absorptiometry. Am J Clin Nutr 52:214–218PubMed Heymsfield SB, Smith R, Aulet M et al (1990) Appendicular skeletal muscle mass: measurement by dual-photon absorptiometry. Am J Clin Nutr 52:214–218PubMed
go back to reference Wang ZM, Visser M, Ma R et al (1996) Skeletal muscle mass: evaluation of neutron activation and dual-energy X-ray absorptiometry methods. J Appl Physiol 80:824–831PubMed Wang ZM, Visser M, Ma R et al (1996) Skeletal muscle mass: evaluation of neutron activation and dual-energy X-ray absorptiometry methods. J Appl Physiol 80:824–831PubMed
Metadata
Title
Role of muscle mass on sprint performance: gender differences? by Jorge Perez-Gomez, German Vicente Rodriguez, Ignacio Ara, Hugo Olmedillas, Javier Chavarren, Juan Jose González-Henriquez, Cecilia Dorado and José A. L. Calbet
Author
Jordan Robert Moon
Publication date
01-06-2008
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 3/2008
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-008-0710-1

Other articles of this Issue 3/2008

European Journal of Applied Physiology 3/2008 Go to the issue