Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 1/2011

01-02-2011 | Laboratory Investigation

Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

Authors: C. M. Sommer, N. Kortes, S. Zelzer, F. U. Arnegger, U. Stampfl, N. Bellemann, T. Gehrig, F. Nickel, H. G. Kenngott, C. Mogler, T. Longerich, H. P. Meinzer, G. M. Richter, H. U. Kauczor, B. A. Radeleff

Published in: CardioVascular and Interventional Radiology | Issue 1/2011

Login to get access

Abstract

The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume_segmented, and volume_calculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 ± 3.6 vs. 17.2 ± 1.8 mm; p < 0.001) and width (20.1 ± 2.9 vs. 12.6 ± 3.7 mm; p < 0.001); significantly larger volume_segmented (8.6 ± 3.2 vs. 3.0 ± 0.7 ml; p < 0.001) and volume_calculated (8.4 ± 3.0 ml vs. 3.3 ± 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 ± 0.10 vs. 1.48 ± 0.44; p < 0.05), sphericity (1.55 ± 0.44 vs. 1.96 ± 0.43; p < 0.01), and eccentricity (0.84 ± 0.61 vs. 1.73 ± 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 ± 0.14 vs. 0.45 ± 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.
Appendix
Available only for authorised users
Literature
1.
go back to reference Rutherford EE, Cast JE, Breen DJ (2008) Immediate and long-term CT appearances following radiofrequency ablation of renal tumours. Clin Radiol 63:220–230CrossRefPubMed Rutherford EE, Cast JE, Breen DJ (2008) Immediate and long-term CT appearances following radiofrequency ablation of renal tumours. Clin Radiol 63:220–230CrossRefPubMed
2.
go back to reference Mondshine RT, Owens S, Mondschein JI et al (2008) Combination embolization and radiofrequency ablation therapy for renal cell carcinoma in the setting of coexisting arterial disease. J Vasc Interv Radiol 19:616–620CrossRefPubMed Mondshine RT, Owens S, Mondschein JI et al (2008) Combination embolization and radiofrequency ablation therapy for renal cell carcinoma in the setting of coexisting arterial disease. J Vasc Interv Radiol 19:616–620CrossRefPubMed
3.
go back to reference Campbell J, Rosenthal DI, Raskin KA et al (2006) Use of an arterial tourniquet to achieve complete radiofrequency ablation of a renal metastasis. J Vasc Interv Radiol 17:1051–1055CrossRefPubMed Campbell J, Rosenthal DI, Raskin KA et al (2006) Use of an arterial tourniquet to achieve complete radiofrequency ablation of a renal metastasis. J Vasc Interv Radiol 17:1051–1055CrossRefPubMed
4.
go back to reference Kyle CC, Wingo MS, Carey RI et al (2008) Diagnostic yield of renal biopsy immediately prior to laparoscopic radiofrequency ablation: a multicenter study. J Endourol 22:2291–2293CrossRefPubMed Kyle CC, Wingo MS, Carey RI et al (2008) Diagnostic yield of renal biopsy immediately prior to laparoscopic radiofrequency ablation: a multicenter study. J Endourol 22:2291–2293CrossRefPubMed
5.
go back to reference Breen DJ, Rutherford EE, Stedman B et al (2007) Management of renal tumors by image-guided radiofrequency ablation: experience in 105 tumors. Cardiovasc Interv Radiol 30:936–942CrossRef Breen DJ, Rutherford EE, Stedman B et al (2007) Management of renal tumors by image-guided radiofrequency ablation: experience in 105 tumors. Cardiovasc Interv Radiol 30:936–942CrossRef
6.
go back to reference Raman JD, Thomas J, Lucas SM et al (2008) Radiofrequency ablation for T1a tumors in a solitary kidney: promising intermediate oncologic and renal function outcomes. Can J Urol 15:3980–3985PubMed Raman JD, Thomas J, Lucas SM et al (2008) Radiofrequency ablation for T1a tumors in a solitary kidney: promising intermediate oncologic and renal function outcomes. Can J Urol 15:3980–3985PubMed
7.
go back to reference Veltri A, Calvo A, Tosetti I et al (2006) Experiences in US-guided percutaneous radiofrequency ablation of 44 renal tumors in 31 patients: analysis of predictors for complications and technical success. Cardiovasc Intervent Radiol 29:811–818CrossRefPubMed Veltri A, Calvo A, Tosetti I et al (2006) Experiences in US-guided percutaneous radiofrequency ablation of 44 renal tumors in 31 patients: analysis of predictors for complications and technical success. Cardiovasc Intervent Radiol 29:811–818CrossRefPubMed
8.
go back to reference Stern JM, Svatek R, Park S et al (2007) Intermediate comparison of partial nephrectomy and radiofrequency ablation for clinical T1a renal tumours. BJU Int 100:287–290CrossRefPubMed Stern JM, Svatek R, Park S et al (2007) Intermediate comparison of partial nephrectomy and radiofrequency ablation for clinical T1a renal tumours. BJU Int 100:287–290CrossRefPubMed
9.
go back to reference Lohr M, Rohde D (2005) Recurrent disease in renal cell carcinoma. “Local recurrence” after kidney-sparing and radical resection. Urologe A 44:358–368CrossRefPubMed Lohr M, Rohde D (2005) Recurrent disease in renal cell carcinoma. “Local recurrence” after kidney-sparing and radical resection. Urologe A 44:358–368CrossRefPubMed
11.
go back to reference Yamakado K, Nakatsuka A, Kobayashi S et al (2006) Radiofrequency ablation combined with renal arterial embolization for the treatment of unresectable renal cell carcinoma larger than 3.5 cm: initial experience. Cardiovasc Interv Radiol 29:389–394CrossRef Yamakado K, Nakatsuka A, Kobayashi S et al (2006) Radiofrequency ablation combined with renal arterial embolization for the treatment of unresectable renal cell carcinoma larger than 3.5 cm: initial experience. Cardiovasc Interv Radiol 29:389–394CrossRef
12.
go back to reference Arima K, Yamakado K, Kinbara H et al (2007) Percutaneous radiofrequency ablation with transarterial embolization is useful for treatment of stage 1 renal cell carcinoma with surgical risk: Results at 2-year mean follow up. Int J Urol 14:585–590CrossRefPubMed Arima K, Yamakado K, Kinbara H et al (2007) Percutaneous radiofrequency ablation with transarterial embolization is useful for treatment of stage 1 renal cell carcinoma with surgical risk: Results at 2-year mean follow up. Int J Urol 14:585–590CrossRefPubMed
13.
go back to reference Marcovich R, Aldana JP, Morgenstern N et al (2003) Optimal lesion assessment following acute radio frequency ablation of porcine kidney: cellular viability or histopathology? J Urol 170:1370–1374CrossRefPubMed Marcovich R, Aldana JP, Morgenstern N et al (2003) Optimal lesion assessment following acute radio frequency ablation of porcine kidney: cellular viability or histopathology? J Urol 170:1370–1374CrossRefPubMed
14.
go back to reference Patterson EJ, Scudamore CH, Owen DA et al (1998) Radiofrequency ablation of porcine liver in vivo: effects of blood flow and treatment time on lesion size. Ann Surg 227:559–565CrossRefPubMed Patterson EJ, Scudamore CH, Owen DA et al (1998) Radiofrequency ablation of porcine liver in vivo: effects of blood flow and treatment time on lesion size. Ann Surg 227:559–565CrossRefPubMed
15.
go back to reference Chung H, Kudo M, Minami Y et al (2007) Radiofrequency ablation combined with reduction of hepatic blood flow: effect of lipiodol on coagulation diameter and ablation time in normal pig liver. Hepatogastroenterology 54:701–704PubMed Chung H, Kudo M, Minami Y et al (2007) Radiofrequency ablation combined with reduction of hepatic blood flow: effect of lipiodol on coagulation diameter and ablation time in normal pig liver. Hepatogastroenterology 54:701–704PubMed
16.
go back to reference Chang I, Mikityansky I, Wray-Cahen D et al (2004) Effects of perfusion on radiofrequency ablation in swine kidneys. Radiology 231:500–505CrossRefPubMed Chang I, Mikityansky I, Wray-Cahen D et al (2004) Effects of perfusion on radiofrequency ablation in swine kidneys. Radiology 231:500–505CrossRefPubMed
17.
go back to reference Nakai M, Sato M, Sahara S et al (2007) Radiofrequency ablation in a porcine liver model: effects of transcatheter arterial embolization with iodized oil on ablation time, maximum output, and coagulation diameter as well as angiographic characteristics. World J Gastroenterol 13:2841–2845PubMed Nakai M, Sato M, Sahara S et al (2007) Radiofrequency ablation in a porcine liver model: effects of transcatheter arterial embolization with iodized oil on ablation time, maximum output, and coagulation diameter as well as angiographic characteristics. World J Gastroenterol 13:2841–2845PubMed
18.
go back to reference Iwamoto T, Kawai N, Sato M et al (2008) Effectiveness of hepatic arterial embolization on radiofrequency ablation volume in a swine model: relationship to portal venous flow and liver parenchymal pressure. J Vasc Interv Radiol 19:1646–1651CrossRefPubMed Iwamoto T, Kawai N, Sato M et al (2008) Effectiveness of hepatic arterial embolization on radiofrequency ablation volume in a swine model: relationship to portal venous flow and liver parenchymal pressure. J Vasc Interv Radiol 19:1646–1651CrossRefPubMed
19.
go back to reference Ritz JP, Lehmann KS, Isbert C et al (2006) In vivo evaluation of a novel bipolar radiofrequency device for interstitial thermotherapy of liver tumors during normal and interrupted hepatic perfusion. J Surg Res 133:176–184CrossRefPubMed Ritz JP, Lehmann KS, Isbert C et al (2006) In vivo evaluation of a novel bipolar radiofrequency device for interstitial thermotherapy of liver tumors during normal and interrupted hepatic perfusion. J Surg Res 133:176–184CrossRefPubMed
20.
go back to reference Bonomo G, Pedicini V, Monfardini L et al (2010) Bland embolization in patients with unresectable hepatocellular carcinoma using precise, tightly size-calibrated, anti-inflammatory microparticles: first clinical experience and one-year follow-up. Cardiovasc Interv Radiol 33:552–559CrossRef Bonomo G, Pedicini V, Monfardini L et al (2010) Bland embolization in patients with unresectable hepatocellular carcinoma using precise, tightly size-calibrated, anti-inflammatory microparticles: first clinical experience and one-year follow-up. Cardiovasc Interv Radiol 33:552–559CrossRef
21.
22.
go back to reference Vogt FM, Antoch G, Veit P et al (2007) Morphologic and functional changes in nontumorous liver tissue after radiofrequency ablation in an in vivo model: comparison of 18F-FDG PET/CT, MRI, ultrasound, and CT. J Nucl Med 48:1836–1844CrossRefPubMed Vogt FM, Antoch G, Veit P et al (2007) Morphologic and functional changes in nontumorous liver tissue after radiofrequency ablation in an in vivo model: comparison of 18F-FDG PET/CT, MRI, ultrasound, and CT. J Nucl Med 48:1836–1844CrossRefPubMed
23.
go back to reference Goldberg SN, Gazelle GS, Compton CC et al (2000) Treatment of intrahepatic malignancy with radiofrequency ablation: radiologic-pathologic correlation. Cancer 88:2452–2463CrossRefPubMed Goldberg SN, Gazelle GS, Compton CC et al (2000) Treatment of intrahepatic malignancy with radiofrequency ablation: radiologic-pathologic correlation. Cancer 88:2452–2463CrossRefPubMed
24.
go back to reference Crowley JD, Shelton J, Iverson AJ et al (2001) Laparoscopic and computed tomography-guided percutaneous radiofrequency ablation of renal tissue: acute and chronic effects in an animal model. Urology 57:976–980CrossRefPubMed Crowley JD, Shelton J, Iverson AJ et al (2001) Laparoscopic and computed tomography-guided percutaneous radiofrequency ablation of renal tissue: acute and chronic effects in an animal model. Urology 57:976–980CrossRefPubMed
25.
go back to reference Burdio F, Navarro A, Sousa R et al (2006) Evolving technology in bipolar perfused radiofrequency ablation: assessment of efficacy, predictability and safety in a pig liver model. Eur Radiol 16:1826–1834CrossRefPubMed Burdio F, Navarro A, Sousa R et al (2006) Evolving technology in bipolar perfused radiofrequency ablation: assessment of efficacy, predictability and safety in a pig liver model. Eur Radiol 16:1826–1834CrossRefPubMed
26.
go back to reference Nakada SY, Jerde TJ, Warner TF et al (2003) Bipolar radiofrequency ablation of the kidney: comparison with monopolar radiofrequency ablation. J Endourol 17:927–933CrossRefPubMed Nakada SY, Jerde TJ, Warner TF et al (2003) Bipolar radiofrequency ablation of the kidney: comparison with monopolar radiofrequency ablation. J Endourol 17:927–933CrossRefPubMed
27.
go back to reference Laeseke PF, Lee FT Jr, Sampson LA et al (2009) Microwave ablation versus radiofrequency ablation in the kidney: high-power triaxial antennas create larger ablation zones than similarly sized internally cooled electrodes. J Vasc Interv Radiol 20:1224–1229CrossRefPubMed Laeseke PF, Lee FT Jr, Sampson LA et al (2009) Microwave ablation versus radiofrequency ablation in the kidney: high-power triaxial antennas create larger ablation zones than similarly sized internally cooled electrodes. J Vasc Interv Radiol 20:1224–1229CrossRefPubMed
28.
go back to reference Hsu TH, Fidler ME, Gill IS (2007) Radiofrequency ablation of the kidney: acute and chronic histology in porcine model. Urology 56:872–875CrossRef Hsu TH, Fidler ME, Gill IS (2007) Radiofrequency ablation of the kidney: acute and chronic histology in porcine model. Urology 56:872–875CrossRef
29.
go back to reference Lee JM, Han JK, Kim SH et al (2007) In vivo efficiency of multipolar radiofrequency ablation with two bipolar electrodes: a comparative experimental study in pig kidney. J Vasc Interv Radiol 18:1553–1560CrossRefPubMed Lee JM, Han JK, Kim SH et al (2007) In vivo efficiency of multipolar radiofrequency ablation with two bipolar electrodes: a comparative experimental study in pig kidney. J Vasc Interv Radiol 18:1553–1560CrossRefPubMed
30.
go back to reference Pereira PL, Trubenbach J, Schenk M et al (2004) Radiofrequency ablation: in vivo comparison of four commercially available devices in pig livers. Radiology 232:482–490CrossRefPubMed Pereira PL, Trubenbach J, Schenk M et al (2004) Radiofrequency ablation: in vivo comparison of four commercially available devices in pig livers. Radiology 232:482–490CrossRefPubMed
31.
go back to reference Denys AL, De Baere T, Kuoch V et al (2003) Radio-frequency tissue ablation of the liver: in vivo and ex vivo experiments with four different systems. Eur Radiol 13:2346–2352CrossRefPubMed Denys AL, De Baere T, Kuoch V et al (2003) Radio-frequency tissue ablation of the liver: in vivo and ex vivo experiments with four different systems. Eur Radiol 13:2346–2352CrossRefPubMed
32.
go back to reference Goldberg SN, Gazelle GS (2001) Radiofrequency tissue ablation: physical principles and techniques for increasing coagulation necrosis. Hepatogastroenterology 48:359–367PubMed Goldberg SN, Gazelle GS (2001) Radiofrequency tissue ablation: physical principles and techniques for increasing coagulation necrosis. Hepatogastroenterology 48:359–367PubMed
33.
go back to reference Goldberg SN, Hahn PF, Tanabe KK et al (1998) Percutaneous radiofrequency tissue ablation: does perfusion-mediated tissue cooling limit coagulation necrosis? J Vasc Interv Radiol 9:101–111CrossRefPubMed Goldberg SN, Hahn PF, Tanabe KK et al (1998) Percutaneous radiofrequency tissue ablation: does perfusion-mediated tissue cooling limit coagulation necrosis? J Vasc Interv Radiol 9:101–111CrossRefPubMed
34.
go back to reference Goldberg SN, Hahn PF, Halpern EF et al (1998) Radio-frequency tissue ablation: effect of pharmacologic modulation of blood flow on coagulation diameter. Radiology 209:761–767PubMed Goldberg SN, Hahn PF, Halpern EF et al (1998) Radio-frequency tissue ablation: effect of pharmacologic modulation of blood flow on coagulation diameter. Radiology 209:761–767PubMed
35.
go back to reference Yamasaki T, Kurokawa F, Shirahashi H et al (2002) Percutaneous radiofrequency ablation therapy for patients with hepatocellular carcinoma during occlusion of hepatic blood flow. Comparison with standard percutaneous radiofrequency ablation therapy. Cancer 95:2353–2360CrossRefPubMed Yamasaki T, Kurokawa F, Shirahashi H et al (2002) Percutaneous radiofrequency ablation therapy for patients with hepatocellular carcinoma during occlusion of hepatic blood flow. Comparison with standard percutaneous radiofrequency ablation therapy. Cancer 95:2353–2360CrossRefPubMed
36.
go back to reference Stampfl S, Bellemann N, Stampfl U et al (2009) Arterial distribution characteristics of embozene particles and comparison with other spherical embolic agents in the porcine acute embolization model. J Vasc Interv Radiol 20:1597–1607CrossRefPubMed Stampfl S, Bellemann N, Stampfl U et al (2009) Arterial distribution characteristics of embozene particles and comparison with other spherical embolic agents in the porcine acute embolization model. J Vasc Interv Radiol 20:1597–1607CrossRefPubMed
37.
go back to reference Stampfl S, Stampfl U, Bellemann N et al (2009) Immunohistochemical characterization of specific inflammatory tissue reactions following embolization with four different spherical agents in the minipig kidney model. J Vasc Interv Radiol 20:936–945CrossRefPubMed Stampfl S, Stampfl U, Bellemann N et al (2009) Immunohistochemical characterization of specific inflammatory tissue reactions following embolization with four different spherical agents in the minipig kidney model. J Vasc Interv Radiol 20:936–945CrossRefPubMed
38.
go back to reference Stampfl S, Bellemann N, Stampfl U et al (2008) Inflammation and recanalization of four different spherical embolization agents in the porcine kidney model. J Vasc Interv Radiol 19:577–586CrossRefPubMed Stampfl S, Bellemann N, Stampfl U et al (2008) Inflammation and recanalization of four different spherical embolization agents in the porcine kidney model. J Vasc Interv Radiol 19:577–586CrossRefPubMed
39.
go back to reference Stampfl U, Stampfl S, Bellemann N et al (2009) Experimental liver embolization with four different spherical embolic materials: impact on inflammatory tissue and foreign body reaction. Cardiovasc Interv Radiol 32:303–312CrossRef Stampfl U, Stampfl S, Bellemann N et al (2009) Experimental liver embolization with four different spherical embolic materials: impact on inflammatory tissue and foreign body reaction. Cardiovasc Interv Radiol 32:303–312CrossRef
40.
go back to reference Kauffmann GW, Richter GM, Roeren T (1991) Current status of embolization materials. Rontgenpraxis 44:146–149PubMed Kauffmann GW, Richter GM, Roeren T (1991) Current status of embolization materials. Rontgenpraxis 44:146–149PubMed
41.
go back to reference Yu SC, Hui JW, Hui EP et al (2009) Embolization efficacy and treatment effectiveness of transarterial therapy for unresectable hepatocellular carcinoma: a case-controlled comparison of transarterial ethanol ablation with lipiodol-ethanol mixture versus transcatheter arterial chemoembolization. J Vasc Interv Radiol 20:352–359CrossRefPubMed Yu SC, Hui JW, Hui EP et al (2009) Embolization efficacy and treatment effectiveness of transarterial therapy for unresectable hepatocellular carcinoma: a case-controlled comparison of transarterial ethanol ablation with lipiodol-ethanol mixture versus transcatheter arterial chemoembolization. J Vasc Interv Radiol 20:352–359CrossRefPubMed
42.
go back to reference Hirakawa M, Ikeda K, Kawamura Y et al (2008) New ablation procedure for a radiofrequency liver tissue coagulation system using an expandable needle. Liver Int 28:214–219CrossRefPubMed Hirakawa M, Ikeda K, Kawamura Y et al (2008) New ablation procedure for a radiofrequency liver tissue coagulation system using an expandable needle. Liver Int 28:214–219CrossRefPubMed
43.
go back to reference Hacker A, Vallo S, Weiss C et al (2005) Minimally invasive treatment of renal cell carcinoma: comparison of 4 different monopolar radiofrequency devices. Eur Urol 48:584–592CrossRefPubMed Hacker A, Vallo S, Weiss C et al (2005) Minimally invasive treatment of renal cell carcinoma: comparison of 4 different monopolar radiofrequency devices. Eur Urol 48:584–592CrossRefPubMed
44.
go back to reference Burdio F, Berjano EJ, Navarro A et al (2009) Research and development of a new RF-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments. Biomed Eng Online 8:6CrossRefPubMed Burdio F, Berjano EJ, Navarro A et al (2009) Research and development of a new RF-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments. Biomed Eng Online 8:6CrossRefPubMed
Metadata
Title
Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape
Authors
C. M. Sommer
N. Kortes
S. Zelzer
F. U. Arnegger
U. Stampfl
N. Bellemann
T. Gehrig
F. Nickel
H. G. Kenngott
C. Mogler
T. Longerich
H. P. Meinzer
G. M. Richter
H. U. Kauczor
B. A. Radeleff
Publication date
01-02-2011
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue 1/2011
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-010-9908-9

Other articles of this Issue 1/2011

CardioVascular and Interventional Radiology 1/2011 Go to the issue