Skip to main content
Top
Published in: Pediatric Cardiology 2/2017

01-02-2017 | Original Article

Reference Ranges of Fetal Cardiac Biometric Parameters Using Three-Dimensional Ultrasound with Spatiotemporal Image Correlation M Mode and Their Applicability in Congenital Heart Diseases

Authors: Giselle Darahem Tedesco, Marilim de Souza Bezerra, Fernanda Silveira Bello Barros, Wellington P. Martins, Luciano Marcondes Machado Nardozza, Milene Carvalho Carrilho, Antonio Fernandes Moron, Francisco Herlânio Costa Carvalho, Liliam Cristine Rolo, Edward Araujo Júnior

Published in: Pediatric Cardiology | Issue 2/2017

Login to get access

Abstract

To determine reference values for fetal heart biometric parameters using the spatiotemporal image correlation (STIC) M mode and their applicability in congenital heart diseases (CHDs). A cross-sectional prospective study was conducted with 300 singleton pregnancies between 20 and 33 + 6 weeks of gestation. Right ventricular wall thickness (RVWT), interventricular septum thickness (IVST), and left ventricular wall thickness (LVWT) were measured off-line using the STIC-M mode with the cursor perpendicular to the interventricular septum. Polynomial regressions adjusted with the coefficient of determination (R 2) were performed. The curves were applied to 14 fetuses with structural CHD. For the reproducibility calculations, the concordance correlation coefficient (CCC) was used. The mean RVWT, IVST, and LVWT were 0.34 ± 0.09 cm, 0.28 ± 0.09 cm, and 0.30 ± 0.07 cm, respectively. There was correlation between RVWT, IVST, and LVWT and gestational age (GA): RVWT = −0.002 + 0.013 × GA (R 2 = 0.33), IVST = −0.011 + 0.011 × GA (R 2 = 0.25), and LVWT = 0.056 + 0.009 × GA (R 2 = 0.26). RVWT, IVST, and LVWT were altered (<5th or >95th percentile) in 5/14, 5/14, and 7/14 of the fetuses with CHD, respectively. For RVWT, IVST, and LVWT, intra-observer (CCC = 0.86, 0.85, and 0.87, respectively) and inter-observer (CCC = 0.86, 0.86, and 0.86, respectively) reproducibility were good/moderate. The reference ranges determined for fetal heart biometric parameters using STIC-M had good intra- and inter-observer reproducibility and were applicable to fetuses with CHD.
Literature
2.
go back to reference Zielinsky P, Luchese S, Manica JL, Piccoli AL Jr, Nicoloso LH, Leite MF, Hagemann L, Busato A, Moraes MR (2009) Left atrial shortening fraction in fetuses with and without myocardial hypertrophy in diabetic pregnancies. Ultrasound Obstet Gynecol 33:182–187CrossRefPubMed Zielinsky P, Luchese S, Manica JL, Piccoli AL Jr, Nicoloso LH, Leite MF, Hagemann L, Busato A, Moraes MR (2009) Left atrial shortening fraction in fetuses with and without myocardial hypertrophy in diabetic pregnancies. Ultrasound Obstet Gynecol 33:182–187CrossRefPubMed
4.
go back to reference Kleinman CS, Hobbins JC, Jaffe CC, Lynch DC, Talner NS (1980) Echocardiographic studies of the human fetus: prenatal diagnosis of congenital heart disease and cardiac dysrhythmias. Pediatrics 65:1059–1067PubMed Kleinman CS, Hobbins JC, Jaffe CC, Lynch DC, Talner NS (1980) Echocardiographic studies of the human fetus: prenatal diagnosis of congenital heart disease and cardiac dysrhythmias. Pediatrics 65:1059–1067PubMed
5.
go back to reference Kassem E, Humpl T, Friedberg MK (2013) Prognostic significance of 2-dimensional, M-mode, and Doppler echo indices of right ventricular function in children with pulmonary arterial hypertension. Am Heart J 165:1024–1031CrossRefPubMed Kassem E, Humpl T, Friedberg MK (2013) Prognostic significance of 2-dimensional, M-mode, and Doppler echo indices of right ventricular function in children with pulmonary arterial hypertension. Am Heart J 165:1024–1031CrossRefPubMed
7.
go back to reference De Vore GR, Siassi B, Platt LD (1985) Use of femur length as a means of assessing M-mode ventricular dimensions during second and third trimesters of pregnancy in normal fetus. J Clin Ultrasound 13:619–625PubMed De Vore GR, Siassi B, Platt LD (1985) Use of femur length as a means of assessing M-mode ventricular dimensions during second and third trimesters of pregnancy in normal fetus. J Clin Ultrasound 13:619–625PubMed
8.
go back to reference Gonçalves LF, Lee W, Chaiworapongsa T, Espinoza J, Schoen ML, Falkensammer P, Treadwell M, Romero R (2003) Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation. Am J Obstet Gynecol 189:1792–1802CrossRefPubMed Gonçalves LF, Lee W, Chaiworapongsa T, Espinoza J, Schoen ML, Falkensammer P, Treadwell M, Romero R (2003) Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation. Am J Obstet Gynecol 189:1792–1802CrossRefPubMed
9.
go back to reference Molina FS, Faro C, Sotiriadis A, Dagklis T, Nicolaides KH (2008) Heart stroke volume and cardiac output by four-dimensional ultrasound in normal fetuses. Ultrasound Obstet Gynecol 32:181–187CrossRefPubMed Molina FS, Faro C, Sotiriadis A, Dagklis T, Nicolaides KH (2008) Heart stroke volume and cardiac output by four-dimensional ultrasound in normal fetuses. Ultrasound Obstet Gynecol 32:181–187CrossRefPubMed
10.
go back to reference Nardozza LM, Rolo LC, Araujo Júnior E, Hatanaka AR, Rocha LA, Simioni C, Ruano R, Moron AF (2013) Reference range for fetal interventricular septum area by means of four-dimensional ultrasonography using spatiotemporal image correlation. Fetal Diagn Ther 33:110–115CrossRefPubMed Nardozza LM, Rolo LC, Araujo Júnior E, Hatanaka AR, Rocha LA, Simioni C, Ruano R, Moron AF (2013) Reference range for fetal interventricular septum area by means of four-dimensional ultrasonography using spatiotemporal image correlation. Fetal Diagn Ther 33:110–115CrossRefPubMed
11.
go back to reference Rolo LC, Rizzo G, Pietrolucci ME, Barros FS, Nardozza LM, Martins WP, Arduini D, Moron AF, Araujo Júnior E (2014) Viewing rate and reference ranges for papillary muscle areas of the fetal heart using four-dimensional ultrasound in the rendering mode. Prenat Diagn 34:1153–1160CrossRefPubMed Rolo LC, Rizzo G, Pietrolucci ME, Barros FS, Nardozza LM, Martins WP, Arduini D, Moron AF, Araujo Júnior E (2014) Viewing rate and reference ranges for papillary muscle areas of the fetal heart using four-dimensional ultrasound in the rendering mode. Prenat Diagn 34:1153–1160CrossRefPubMed
12.
go back to reference Messing B, Gilboa Y, Lipschuetz M, Valsky DV, Cohen SM, Yagel S (2013) Fetal tricuspid annular plane systolic excursion (f-TAPSE): evaluation of fetal right heart systolic function with conventional M-mode ultrasound and spatiotemporal image correlation (STIC) M-mode. Ultrasound Obstet Gynecol 42:182–188CrossRefPubMed Messing B, Gilboa Y, Lipschuetz M, Valsky DV, Cohen SM, Yagel S (2013) Fetal tricuspid annular plane systolic excursion (f-TAPSE): evaluation of fetal right heart systolic function with conventional M-mode ultrasound and spatiotemporal image correlation (STIC) M-mode. Ultrasound Obstet Gynecol 42:182–188CrossRefPubMed
13.
go back to reference Luewan S, Yanase Y, Tongprasert F, Srisupundit K, Tongsong T (2011) Fetal cardiac dimensions at 14-40 weeks’ gestation obtained using cardio-STIC-M. Ultrasound Obstet Gynecol 37:416–422CrossRefPubMed Luewan S, Yanase Y, Tongprasert F, Srisupundit K, Tongsong T (2011) Fetal cardiac dimensions at 14-40 weeks’ gestation obtained using cardio-STIC-M. Ultrasound Obstet Gynecol 37:416–422CrossRefPubMed
14.
go back to reference International Society of Ultrasound in Obstetrics and Gynecology, Carvalho JS, Allan LD, Chaoui R, Copel JA, DeVore GR, Hecher K, Lee W, Munoz H, Paladini D, Tutschek B, Yagel S (2013) ISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart. Ultrasound Obstet Gynecol 41:348–359CrossRefPubMed International Society of Ultrasound in Obstetrics and Gynecology, Carvalho JS, Allan LD, Chaoui R, Copel JA, DeVore GR, Hecher K, Lee W, Munoz H, Paladini D, Tutschek B, Yagel S (2013) ISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart. Ultrasound Obstet Gynecol 41:348–359CrossRefPubMed
15.
go back to reference Gonçalves LF, Lee W, Espinoza J, Romero R (2006) Examination of fetal heart by four-dimensional (4D) ultrasound with spatio-temporal image correlation (STIC). Ultrasound Obstet Gynecol 27:336–348CrossRefPubMed Gonçalves LF, Lee W, Espinoza J, Romero R (2006) Examination of fetal heart by four-dimensional (4D) ultrasound with spatio-temporal image correlation (STIC). Ultrasound Obstet Gynecol 27:336–348CrossRefPubMed
16.
17.
go back to reference Martins WP, Nastri CO (2014) Interpreting reproducibility results for ultrasound measurements. Ultrasound Obstet Gynecol 43:479–480CrossRefPubMed Martins WP, Nastri CO (2014) Interpreting reproducibility results for ultrasound measurements. Ultrasound Obstet Gynecol 43:479–480CrossRefPubMed
18.
go back to reference Cooper MJ, Enderlein MA, Tarnoff H, Rogé CL (1992) Asymmetric septal hypertrophy in infants of diabetic mothers. Fetal echocardiography and the impact of maternal diabetic control. Am J Dis Child 146:226–229CrossRefPubMed Cooper MJ, Enderlein MA, Tarnoff H, Rogé CL (1992) Asymmetric septal hypertrophy in infants of diabetic mothers. Fetal echocardiography and the impact of maternal diabetic control. Am J Dis Child 146:226–229CrossRefPubMed
19.
go back to reference Fouda UM, Abou ElKassem MM, Hefny SM, Fouda RM, Hashem AT (2013) Role of fetal echocardiography in the evaluation of structure and function of fetal heart in diabetic pregnancies. J Matern Fetal Neonatal Med 26:571–575CrossRefPubMed Fouda UM, Abou ElKassem MM, Hefny SM, Fouda RM, Hashem AT (2013) Role of fetal echocardiography in the evaluation of structure and function of fetal heart in diabetic pregnancies. J Matern Fetal Neonatal Med 26:571–575CrossRefPubMed
20.
go back to reference Balli S, Pac FA, Ece İ, Oflaz MB, Kibar AE, Kandemir Ö (2014) Assessment of cardiac functions in fetuses of gestational diabetic mothers. Pediatr Cardiol 35:30–37CrossRefPubMed Balli S, Pac FA, Ece İ, Oflaz MB, Kibar AE, Kandemir Ö (2014) Assessment of cardiac functions in fetuses of gestational diabetic mothers. Pediatr Cardiol 35:30–37CrossRefPubMed
21.
go back to reference DeVore GR (2005) Assessing fetal cardiac ventricular function. Semin Fetal Neonatal Med 10:515–541CrossRefPubMed DeVore GR (2005) Assessing fetal cardiac ventricular function. Semin Fetal Neonatal Med 10:515–541CrossRefPubMed
22.
go back to reference Viñals F, Mandujano L, Vargas G, Giuliano A (2005) Prenatal diagnosis of congenital heart disease using four-dimensional spatio-temporal image correlation (STIC) telemedicine via an Internet link: a pilot study. Ultrasound Obstet Gynecol 25:25–31CrossRefPubMed Viñals F, Mandujano L, Vargas G, Giuliano A (2005) Prenatal diagnosis of congenital heart disease using four-dimensional spatio-temporal image correlation (STIC) telemedicine via an Internet link: a pilot study. Ultrasound Obstet Gynecol 25:25–31CrossRefPubMed
23.
go back to reference Tongsong T, Wanapirak C, Piyamongkol W, Sirichotiyakul S, Tongprasert F, Srisupundit K, Luewan S (2011) Fetal ventricular shortening fraction in hydrops fetalis. Obstet Gynecol 117:84–91CrossRefPubMed Tongsong T, Wanapirak C, Piyamongkol W, Sirichotiyakul S, Tongprasert F, Srisupundit K, Luewan S (2011) Fetal ventricular shortening fraction in hydrops fetalis. Obstet Gynecol 117:84–91CrossRefPubMed
24.
go back to reference Messing B, Gilboa Y, Lipschuetz M, Valsky DV, Cohen SM, Yagel S (2013) Fetal tricuspid annular plane systolic excursion (f-TAPSE): evaluation of fetal right heart systolic function with conventional M-mode ultrasound and spatiotemporal image correlation (STIC) M-mode. Ultrasound Obstet Gynecol 42:182–188CrossRefPubMed Messing B, Gilboa Y, Lipschuetz M, Valsky DV, Cohen SM, Yagel S (2013) Fetal tricuspid annular plane systolic excursion (f-TAPSE): evaluation of fetal right heart systolic function with conventional M-mode ultrasound and spatiotemporal image correlation (STIC) M-mode. Ultrasound Obstet Gynecol 42:182–188CrossRefPubMed
25.
go back to reference Maeno Y, Hirose A, Kanbe T, Hori D (2009) Fetal arrhythmia: prenatal diagnosis and perinatal management. J Obstet Gynaecol Res 35:623–629CrossRefPubMed Maeno Y, Hirose A, Kanbe T, Hori D (2009) Fetal arrhythmia: prenatal diagnosis and perinatal management. J Obstet Gynaecol Res 35:623–629CrossRefPubMed
26.
go back to reference Salih M, Demirel LC, Kurtay G (1998) Prenatal diagnosis of ostium secundum atrial septal defect by M-mode fetal echocardiography. Gynecol Obstet Invest 45:68–70CrossRefPubMed Salih M, Demirel LC, Kurtay G (1998) Prenatal diagnosis of ostium secundum atrial septal defect by M-mode fetal echocardiography. Gynecol Obstet Invest 45:68–70CrossRefPubMed
27.
go back to reference Simpson JM, Cook A (2002) Repeatability of echocardiographic measurements in the human fetus. Ultrasound Obstet Gynecol 20:332–339CrossRefPubMed Simpson JM, Cook A (2002) Repeatability of echocardiographic measurements in the human fetus. Ultrasound Obstet Gynecol 20:332–339CrossRefPubMed
Metadata
Title
Reference Ranges of Fetal Cardiac Biometric Parameters Using Three-Dimensional Ultrasound with Spatiotemporal Image Correlation M Mode and Their Applicability in Congenital Heart Diseases
Authors
Giselle Darahem Tedesco
Marilim de Souza Bezerra
Fernanda Silveira Bello Barros
Wellington P. Martins
Luciano Marcondes Machado Nardozza
Milene Carvalho Carrilho
Antonio Fernandes Moron
Francisco Herlânio Costa Carvalho
Liliam Cristine Rolo
Edward Araujo Júnior
Publication date
01-02-2017
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 2/2017
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-016-1509-1

Other articles of this Issue 2/2017

Pediatric Cardiology 2/2017 Go to the issue