Skip to main content
Top
Published in: Lasers in Medical Science 5/2014

Open Access 01-09-2014 | Original Article

Reduction in adipose tissue volume using a new high-power radiofrequency technology combined with infrared light and mechanical manipulation for body contouring

Authors: Maurice A. Adatto, Robyn M. Adatto-Neilson, Grietje Morren

Published in: Lasers in Medical Science | Issue 5/2014

Login to get access

Abstract

A growing patient demand for a youthful skin appearance with a favorable body shape has led to the recent development of new noninvasive body contouring techniques. We have previously demonstrated that the combination of bipolar radiofrequency (RF) and optical energies with tissue manipulation is an efficient reshaping modality. Here, we investigated the efficacy and safety of a new high-power version of this combined technology, in terms of adipose tissue reduction and skin tightening. Thirty-five patients received one treatment per week over 6 weeks to their abdomen/flank, buttock, or thigh areas and were followed up to 3 months post completion of the treatment protocol. This new device has an increased power in the bipolar RF, as this parameter appears to be the most important energy modality for volume reduction. Patient circumferences were measured and comparisons of baseline and post treatment outcomes were made. Diagnostic ultrasound (US) measurements were performed in 12 patients to evaluate the reduction in adipose tissue volume, and a cutometer device was used to assess improvements in skin tightening. We observed a gradual decline in patient circumferences from baseline to post six treatments. The overall body shaping effect was accompanied with improvement in skin tightening and was clearly noticeable in the comparison of the before and after treatment clinical photographs. These findings correlated with measurements of adipose tissue volume and skin firmness/elasticity using diagnostic US and cutometer, respectively. The thickness of the fat layer showed on average a 29 % reduction between baseline and the 1-month follow up. The average reduction in the circumference of the abdomen/flanks, buttocks, and thighs from baseline to the 3-month follow-up was 1.4, 0.5, and 1.2 cm, respectively, and 93 % of study participants demonstrated a 1–60 % change in fat layer thickness. Patients subjectively described comfort and satisfaction from treatment, and 97 % of them were satisfied with the results at the follow-up visit. The application of high-power RF energy combined with infrared (IR), mechanical massage, and vacuum appears to be an effective modality for the reduction in circumferences of the abdomen/flank, buttock and thigh regions, and the improvement of skin appearance. The present study performed with a new device suggests that the underlying mechanism of action is reduction in the subcutaneous adipose tissue volume and intensification of dermal matrix density.
Literature
1.
2.
go back to reference Zelickson B, Kist D, Berstein E, Brown D, Ksenzenko S, Burns J, Kilmer S, Mehregan D, Pope K (2004) Histological and ultrastructural evaluation of the effects of a radiofrequency-based nonablative dermal remodeling device. A pilot study. Arch Derm 140:204–209PubMedCrossRef Zelickson B, Kist D, Berstein E, Brown D, Ksenzenko S, Burns J, Kilmer S, Mehregan D, Pope K (2004) Histological and ultrastructural evaluation of the effects of a radiofrequency-based nonablative dermal remodeling device. A pilot study. Arch Derm 140:204–209PubMedCrossRef
3.
go back to reference Sadick NS (2005) Combination radiofrequency and light energies: electro-optical synergy technology in esthetic medicine. Derm Surg 31:1211–1217CrossRef Sadick NS (2005) Combination radiofrequency and light energies: electro-optical synergy technology in esthetic medicine. Derm Surg 31:1211–1217CrossRef
5.
go back to reference Alster TS, Lupton JR (2007) Nonablative cutaneous remodeling using radiofrequency devices. Clin Dermatol 25:487–491PubMedCrossRef Alster TS, Lupton JR (2007) Nonablative cutaneous remodeling using radiofrequency devices. Clin Dermatol 25:487–491PubMedCrossRef
6.
go back to reference Alster TS, Tanzi EL (2005) Cellulite treatment using a novel combination radiofrequency, infrared and mechanical tissue manipulation device. J Cosmet Laser Ther 7:81–85PubMedCrossRef Alster TS, Tanzi EL (2005) Cellulite treatment using a novel combination radiofrequency, infrared and mechanical tissue manipulation device. J Cosmet Laser Ther 7:81–85PubMedCrossRef
7.
go back to reference Alster TS, Tehrani M (2006) Cellulite treatment using a novel combination radiofrequency, infrared light, and mechanical tissue manipulation device. Lasers Surg Med 38:727–730PubMedCrossRef Alster TS, Tehrani M (2006) Cellulite treatment using a novel combination radiofrequency, infrared light, and mechanical tissue manipulation device. Lasers Surg Med 38:727–730PubMedCrossRef
8.
go back to reference Sadick NS, Magro C (2007) A study evaluating the safety and efficacy of the VelaSmooth system in the treatment of cellulite. J Cosmet Laser Ther 9:15–20PubMedCrossRef Sadick NS, Magro C (2007) A study evaluating the safety and efficacy of the VelaSmooth system in the treatment of cellulite. J Cosmet Laser Ther 9:15–20PubMedCrossRef
9.
go back to reference Kulick M (2006) Evaluation of the combination of radio frequency, infrared energy and mechanical rollers with suction to improve skin surface irregularities (cellulite) in a limited treatment area. J Cosmet Laser Ther 8:185–190PubMedCrossRef Kulick M (2006) Evaluation of the combination of radio frequency, infrared energy and mechanical rollers with suction to improve skin surface irregularities (cellulite) in a limited treatment area. J Cosmet Laser Ther 8:185–190PubMedCrossRef
10.
go back to reference Sadick NS, Mulholland RS (2004) A prospective clinical study to evaluate the efficacy and safety of cellulite treatment using the combination of optical and RF energies for subcutaneous tissue heating. J Cosmet Laser Ther 6:187–190PubMedCrossRef Sadick NS, Mulholland RS (2004) A prospective clinical study to evaluate the efficacy and safety of cellulite treatment using the combination of optical and RF energies for subcutaneous tissue heating. J Cosmet Laser Ther 6:187–190PubMedCrossRef
11.
go back to reference Wanitphakdeedecha R, Manuskiatti W (2006) Treatment of cellulite with a bipolar radiofrequency, infrared heat, and pulsatile suction device: a pilot study. J Cosmet Dermatol 5:284–288PubMedCrossRef Wanitphakdeedecha R, Manuskiatti W (2006) Treatment of cellulite with a bipolar radiofrequency, infrared heat, and pulsatile suction device: a pilot study. J Cosmet Dermatol 5:284–288PubMedCrossRef
12.
go back to reference Nootheti PK, Magpantay A, Yosowitz G, Calderon S, Goldman M (2006) A single center, randomized, comparative prospective clinical study to determine the efficacy of the Velasmooth System versus the Triactive System for the treatment of cellulite. Lasers Surg Med 38(10):908–912PubMedCrossRef Nootheti PK, Magpantay A, Yosowitz G, Calderon S, Goldman M (2006) A single center, randomized, comparative prospective clinical study to determine the efficacy of the Velasmooth System versus the Triactive System for the treatment of cellulite. Lasers Surg Med 38(10):908–912PubMedCrossRef
13.
go back to reference Drizdal T, Togni P, Viseki L, Vrba J (2010) Comparison of constant and temperature dependent blood perfusion in temperature prediction for superficial hyperthermia. Radioengineering 19(2):281–289 Drizdal T, Togni P, Viseki L, Vrba J (2010) Comparison of constant and temperature dependent blood perfusion in temperature prediction for superficial hyperthermia. Radioengineering 19(2):281–289
14.
go back to reference Mulholland RS (2004) Bipolar radiofrequency, infrared heat and pulsatile suction in the non-surgical treatment of focal lipodystrophy and cellulite. Aust Cosmet Surg 26:101–103 Mulholland RS (2004) Bipolar radiofrequency, infrared heat and pulsatile suction in the non-surgical treatment of focal lipodystrophy and cellulite. Aust Cosmet Surg 26:101–103
15.
go back to reference Brightman L, Weiss E, Chapas AM, Karen J, Hale E, Bernstein L, Geronemus RG (2009) Improvement in arm and post-partum abdominal and flank subcutaneous fat deposits and skin laxity using a bipolar radiofrequency, infrared, vacuum and mechanical massage device. Lasers Surg Med 41(10):791–798PubMedCrossRef Brightman L, Weiss E, Chapas AM, Karen J, Hale E, Bernstein L, Geronemus RG (2009) Improvement in arm and post-partum abdominal and flank subcutaneous fat deposits and skin laxity using a bipolar radiofrequency, infrared, vacuum and mechanical massage device. Lasers Surg Med 41(10):791–798PubMedCrossRef
16.
go back to reference Agarwal SK, Misra A, Aggarwal P, Bardia A, Goel R, Vikram AK, Wasir JS, Hussain N, Ramachandran K, Pandey RM (2009) Waist circumference measurement by site, posture, respiratory phase, and meal time: implications for methodology. Obes J 17(5):1056–1061CrossRef Agarwal SK, Misra A, Aggarwal P, Bardia A, Goel R, Vikram AK, Wasir JS, Hussain N, Ramachandran K, Pandey RM (2009) Waist circumference measurement by site, posture, respiratory phase, and meal time: implications for methodology. Obes J 17(5):1056–1061CrossRef
Metadata
Title
Reduction in adipose tissue volume using a new high-power radiofrequency technology combined with infrared light and mechanical manipulation for body contouring
Authors
Maurice A. Adatto
Robyn M. Adatto-Neilson
Grietje Morren
Publication date
01-09-2014
Publisher
Springer London
Published in
Lasers in Medical Science / Issue 5/2014
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-014-1564-x

Other articles of this Issue 5/2014

Lasers in Medical Science 5/2014 Go to the issue