Skip to main content
Top
Published in: BMC Infectious Diseases 1/2006

Open Access 01-12-2006 | Technical advance

Real-Time PCR for detection of herpes simplex virus without nucleic acid extraction

Authors: Mark W Pandori, John Lei, Ernest H Wong, Jeffrey Klausner, Sally Liska

Published in: BMC Infectious Diseases | Issue 1/2006

Login to get access

Abstract

Background

The speed and sensitivity of real-time polymerase chain reaction (PCR) have made it a popular method for the detection of microbiological agents in both research and clinical specimens. For the detection and genotyping of herpes simplex virus (HSV) in clinical specimens, real-time PCR has proven to be faster, more sensitive and safer than earlier methods which included isolation of the virus in cell culture followed by immunofluorescence microscopy. While PCR-based assays for HSV detection posses clear advantages over these earlier techniques, certain aspects of the PCR method remain onerous. The process of extraction and purification of nucleic acid from clinical specimens prior to PCR is particularly cumbersome. Nucleic acid extraction is expensive, time-consuming and provides a step whereby specimens can become contaminated prior to their analysis. Herein, we investigate the necessity of nucleic acid extraction from swab-based clinical specimens for HSV detection by real-time PCR. We find that nucleic acid extraction is unnecessary for specific and sensitive detection of HSV in clinical specimens using real-time PCR.

Methods

Prospective (n = 36) and retrospective (n = 21) clinical specimens from various anatomical sites were analyzed for the presence of herpes simplex virus 1 or 2 by real-time PCR using the RealArt HSV 1/2 LC PCR Kit. Specimens were analyzed by PCR both before and following automated nucleic acid extraction. PCR using extracted and unextracted specimens was also compared to cell culture as a means of detecting HSV.

Results

Detection of HSV 1/2 DNA in clinical specimens by real-time PCR did not require that the specimen be subjected to nucleic acid extraction/purification prior to analysis. Each specimen that was detectable by real-time PCR when analyzed in the extracted form was also detectable when analyzed in the unextracted form using the methods herein. The limit of detection of HSV-1 and HSV-2 particles when analyzed in the unextracted form was found to be approximately 17 and 32 virus particles respectively, compared to a sensitivity of 10 copies, for analysis of purified DNA. Omission of the nucleic acid extraction step shortened both the assay time and cost.

Conclusion

Omission of the nucleic acid extraction step prior to real-time PCR for detection of herpes simplex virus resulted in a more rapid and cost-effective assay, with little impact upon the sensitivity of detection.
Appendix
Available only for authorised users
Literature
1.
go back to reference Filén F, Strand A, Allard A, Blomberg J, Herrmann B: Duplex Real-Time Polymerase Chain Reaction Assay for Detection and Quantification of Herpes Simplex Virus Type 1 and Herpes Simplex Virus Type 2 in Genital and Cutaneous Lesions. Sexually Transmitted Diseases. 2004, 6: 331-336. 10.1097/00007435-200406000-00002.CrossRef Filén F, Strand A, Allard A, Blomberg J, Herrmann B: Duplex Real-Time Polymerase Chain Reaction Assay for Detection and Quantification of Herpes Simplex Virus Type 1 and Herpes Simplex Virus Type 2 in Genital and Cutaneous Lesions. Sexually Transmitted Diseases. 2004, 6: 331-336. 10.1097/00007435-200406000-00002.CrossRef
2.
go back to reference Koenig M, Reynolds KS, Aldous W, Hickman M: Comparison of Light-Cycler PCR, enzyme immunoassay, and tissue culture for detection of herpes simplex virus. Diagnostic Microbiology and Infectious Disease. 2001, 40 (3): 107-10. 10.1016/S0732-8893(01)00260-7.CrossRefPubMed Koenig M, Reynolds KS, Aldous W, Hickman M: Comparison of Light-Cycler PCR, enzyme immunoassay, and tissue culture for detection of herpes simplex virus. Diagnostic Microbiology and Infectious Disease. 2001, 40 (3): 107-10. 10.1016/S0732-8893(01)00260-7.CrossRefPubMed
3.
go back to reference Espy M, Uhl J, Mitchell P, Thorvilson J, Svien K, Wold A, Smith T: Diagnosis of Herpes Simplex Virus Infections in the Clinical Laboratory by LightCycler PCR. Journal of Clinical Microbiology. 2000, 38: 795-799.PubMedPubMedCentral Espy M, Uhl J, Mitchell P, Thorvilson J, Svien K, Wold A, Smith T: Diagnosis of Herpes Simplex Virus Infections in the Clinical Laboratory by LightCycler PCR. Journal of Clinical Microbiology. 2000, 38: 795-799.PubMedPubMedCentral
4.
go back to reference Whiley DM, Syrmis MW, Mackay IM, Sloots TP: Preliminary comparison of three LightCycler PCR assays for the detection of herpes simplex virus in swab specimens. Eur J Clin Microbiol Infect Dis. 2003, 22 (12): 764-7. 10.1007/s10096-003-1031-2. Epub 2003 Nov 7CrossRefPubMed Whiley DM, Syrmis MW, Mackay IM, Sloots TP: Preliminary comparison of three LightCycler PCR assays for the detection of herpes simplex virus in swab specimens. Eur J Clin Microbiol Infect Dis. 2003, 22 (12): 764-7. 10.1007/s10096-003-1031-2. Epub 2003 Nov 7CrossRefPubMed
5.
go back to reference Schuurman T, van Breda A, de Boer R, Kooistra-Smid M, Beld M, Savelkoul P, Boom R: Reduced PCR sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation Kit. Journal of Clinical Microbiology. 2005, 43: 4616-4622. 10.1128/JCM.43.9.4616-4622.2005.CrossRefPubMedPubMedCentral Schuurman T, van Breda A, de Boer R, Kooistra-Smid M, Beld M, Savelkoul P, Boom R: Reduced PCR sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation Kit. Journal of Clinical Microbiology. 2005, 43: 4616-4622. 10.1128/JCM.43.9.4616-4622.2005.CrossRefPubMedPubMedCentral
6.
go back to reference Lind-Brandberg L, Welinder-Olsson C, Lagergård T, Tranger J, Trollfors B, Zackrisson G: Evaluation of PCR for Diagnosis of Bordetella pertussis and Bordetella parapertussis Infections. Journal of Clinical Microbiology. 1998, 36: 679-683.PubMedPubMedCentral Lind-Brandberg L, Welinder-Olsson C, Lagergård T, Tranger J, Trollfors B, Zackrisson G: Evaluation of PCR for Diagnosis of Bordetella pertussis and Bordetella parapertussis Infections. Journal of Clinical Microbiology. 1998, 36: 679-683.PubMedPubMedCentral
7.
go back to reference Veldwijk M, Topaly J, Laufs S, Hengge U, Wenz F, Zeller W, Fruehauf S: Development and Optimization of a Real-Time Quantitative PCR-based Method for the Titration of AAV-2 Vector Stocks. Molecular Therapy. 2002, 6: 272-278. 10.1006/mthe.2002.0659.CrossRefPubMed Veldwijk M, Topaly J, Laufs S, Hengge U, Wenz F, Zeller W, Fruehauf S: Development and Optimization of a Real-Time Quantitative PCR-based Method for the Titration of AAV-2 Vector Stocks. Molecular Therapy. 2002, 6: 272-278. 10.1006/mthe.2002.0659.CrossRefPubMed
Metadata
Title
Real-Time PCR for detection of herpes simplex virus without nucleic acid extraction
Authors
Mark W Pandori
John Lei
Ernest H Wong
Jeffrey Klausner
Sally Liska
Publication date
01-12-2006
Publisher
BioMed Central
Published in
BMC Infectious Diseases / Issue 1/2006
Electronic ISSN: 1471-2334
DOI
https://doi.org/10.1186/1471-2334-6-104

Other articles of this Issue 1/2006

BMC Infectious Diseases 1/2006 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.