Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2019

Open Access 01-12-2019 | Research article

Real-time intraoperative 3D image intensifier-based navigation in reversed shoulder arthroplasty- analyses of image quality

Authors: Jan Theopold, Philipp Pieroh, Ralf Henkelmann, Georg Osterhoff, Pierre Hepp

Published in: BMC Musculoskeletal Disorders | Issue 1/2019

Login to get access

Abstract

Background

Due to the high anatomical variability and limited visualization of the scapula, optimal screw placement for baseplate anchorage in reversed total shoulder arthroplasty (rTSA) is challenging. Image quality plays a key role regarding the decision of an appropriate implant position. However, these data a currently missing for rTSA and were investigated in the present study. Furthermore, the rate of required K-wire changes for the central peg as well as post-implantation inclination and version were assessed.

Methods

In ten consecutive patients (8 female, 86 years, range 74–94) with proximal humeral fracture and indication for rTSA, an intraoperative 3D-scan of the shoulder with a 3D image intensifier (Ziehm Vision FD Vario 3D© [Ziehm Imaging GmbH, Nürnberg, Germany]) was performed after resection of the humeral head. Using the Vectorvision© Software (Brainlab AG, Feldkirchen, Germany), the virtual anatomy was compared to the visible anatomical landmarks. After implantation of the baseplate, a 3D scan was performed. All 3D scans included multiplanar reconstruction (MPR) and the cinemode to examine screw and baseplate placement. The rate of required K-wire changes was assessed. The intraoperative 3D image quality (modified visual analogue scale [VAS] and point system) was assessed before and after implantation of the glenoid component. Inclination and version were determined in post-implantation scans.

Results

The virtually presented anatomical landmarks always correlated to the anatomical visible points indicating an good virtual accuracy. The central K-wire position was corrected in three cases due to a deviation from the face plane technique position. The VAS was higher for the pre-implantation MPR (6.7, range 5–8) compared to the post-implantation acquired MPR (5.1, range 4–6; p = 0.0002). The point system showed a reduced quality in all subcategories, especially regarding the grading of the articular surfaces. The preoperative (7.9, range 6–9) and post-implantation (7.9, range 6–9) cinemode displayed no significant differences (p = 0.6).

Conclusion

The present study underlines the need for the improvement of 3D image intensifiers algorithms to reduce artifact associated impaired image quality to enhance the benefit of real-time intraoperative 3D scans and navigation.
Literature
1.
go back to reference Bohsali KI, Wirth MA, RockwoodJr CA. Complications of total shoulder arthroplasty. J Bone Jt Surg. 2006;88:2279–92. Bohsali KI, Wirth MA, RockwoodJr CA. Complications of total shoulder arthroplasty. J Bone Jt Surg. 2006;88:2279–92.
2.
go back to reference Farron A, Terrier A, Büchler P. Risks of loosening of a prosthetic glenoid implanted in retroversion. J Shoulder Elb Surg Am Shoulder Elb Surg Al. 2006;15:521–6.CrossRef Farron A, Terrier A, Büchler P. Risks of loosening of a prosthetic glenoid implanted in retroversion. J Shoulder Elb Surg Am Shoulder Elb Surg Al. 2006;15:521–6.CrossRef
3.
go back to reference Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff RESULTS OF a MULTICENTRE STUDY OF 80 SHOULDERS. J Bone Joint Surg Br. 2004;86:388–95.CrossRef Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff RESULTS OF a MULTICENTRE STUDY OF 80 SHOULDERS. J Bone Joint Surg Br. 2004;86:388–95.CrossRef
4.
go back to reference Verborgt O, De Smedt T, Vanhees M, Clockaerts S, Parizel PM, Van Glabbeek F. Accuracy of placement of the glenoid component in reversed shoulder arthroplasty with and without navigation. J Shoulder Elb Surg. 2011;20:21–6.CrossRef Verborgt O, De Smedt T, Vanhees M, Clockaerts S, Parizel PM, Van Glabbeek F. Accuracy of placement of the glenoid component in reversed shoulder arthroplasty with and without navigation. J Shoulder Elb Surg. 2011;20:21–6.CrossRef
5.
go back to reference Kwon YW, Powell KA, Yum JK, Brems JJ, Iannotti JP. Use of three-dimensional computed tomography for the analysis of the glenoid anatomy. J Shoulder Elb Surg. 2005;14:85–90.CrossRef Kwon YW, Powell KA, Yum JK, Brems JJ, Iannotti JP. Use of three-dimensional computed tomography for the analysis of the glenoid anatomy. J Shoulder Elb Surg. 2005;14:85–90.CrossRef
6.
go back to reference Bicknell RT, DeLude JA, Kedgley AE, Ferreira LM, Dunning CE, King GJW, et al. Early experience with computer-assisted shoulder hemiarthroplasty for fractures of the proximal humerus: development of a novel technique and an in vitro comparison with traditional methods. J Shoulder Elb Surg. 2007;16:S117–25.CrossRef Bicknell RT, DeLude JA, Kedgley AE, Ferreira LM, Dunning CE, King GJW, et al. Early experience with computer-assisted shoulder hemiarthroplasty for fractures of the proximal humerus: development of a novel technique and an in vitro comparison with traditional methods. J Shoulder Elb Surg. 2007;16:S117–25.CrossRef
7.
go back to reference Codsi MJ, Bennetts C, Gordiev K, Boeck DM, Kwon Y, Brems J, et al. Normal glenoid vault anatomy and validation of a novel glenoid implant shape. J Shoulder Elb Surg. 2008;17:471–8.CrossRef Codsi MJ, Bennetts C, Gordiev K, Boeck DM, Kwon Y, Brems J, et al. Normal glenoid vault anatomy and validation of a novel glenoid implant shape. J Shoulder Elb Surg. 2008;17:471–8.CrossRef
8.
go back to reference Edwards TB, Gartsman GM, O’Connor DP, Sarin VK. Safety and utility of computer-aided shoulder arthroplasty. J Shoulder Elb Surg. 2008;17:503–8.CrossRef Edwards TB, Gartsman GM, O’Connor DP, Sarin VK. Safety and utility of computer-aided shoulder arthroplasty. J Shoulder Elb Surg. 2008;17:503–8.CrossRef
9.
go back to reference Matsen FA, Boileau P, Walch G, Gerber C, Bicknell RT. The reverse Total shoulder arthroplasty. J Bone Joint Surg Am. 2006;88A:660–7. Matsen FA, Boileau P, Walch G, Gerber C, Bicknell RT. The reverse Total shoulder arthroplasty. J Bone Joint Surg Am. 2006;88A:660–7.
10.
go back to reference Middernacht B, De Roo P-J, Van Maele G, De Wilde LF. Consequences of scapular anatomy for reversed total shoulder arthroplasty. Clin Orthop. 2008;466:1410–8.CrossRef Middernacht B, De Roo P-J, Van Maele G, De Wilde LF. Consequences of scapular anatomy for reversed total shoulder arthroplasty. Clin Orthop. 2008;466:1410–8.CrossRef
11.
go back to reference Lewis GS, Bryce CD, Davison AC, Hollenbeak CS, Piazza SJ, Armstrong AD. Location of the optimized centerline of the glenoid vault: a comparison of two operative techniques with use of three-dimensional computer modeling. J Bone Joint Surg Am. 2010;92:1188–94.CrossRef Lewis GS, Bryce CD, Davison AC, Hollenbeak CS, Piazza SJ, Armstrong AD. Location of the optimized centerline of the glenoid vault: a comparison of two operative techniques with use of three-dimensional computer modeling. J Bone Joint Surg Am. 2010;92:1188–94.CrossRef
12.
go back to reference Hendel MD, Bryan JA, Barsoum WK, Rodriguez EJ, Brems JJ, Evans PJ, et al. Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial. J Bone Joint Surg Am. 2012;94:2167–75.CrossRef Hendel MD, Bryan JA, Barsoum WK, Rodriguez EJ, Brems JJ, Evans PJ, et al. Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial. J Bone Joint Surg Am. 2012;94:2167–75.CrossRef
13.
go back to reference Throckmorton TW, Gulotta LV, Bonnarens FO, Wright SA, Hartzell JL, Rozzi WB, et al. Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty: a multi-surgeon study in 70 arthritic cadaver specimens. J Shoulder Elb Surg. 2015;24:965–71.CrossRef Throckmorton TW, Gulotta LV, Bonnarens FO, Wright SA, Hartzell JL, Rozzi WB, et al. Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty: a multi-surgeon study in 70 arthritic cadaver specimens. J Shoulder Elb Surg. 2015;24:965–71.CrossRef
14.
go back to reference Verborgt O, Vanhees M, Heylen S, Hardy P, Declercq G, Bicknell R. Computer navigation and patient-specific instrumentation in shoulder arthroplasty. Sports Med Arthrosc Rev. 2014;22:e42–9.CrossRef Verborgt O, Vanhees M, Heylen S, Hardy P, Declercq G, Bicknell R. Computer navigation and patient-specific instrumentation in shoulder arthroplasty. Sports Med Arthrosc Rev. 2014;22:e42–9.CrossRef
15.
go back to reference Walch G, Vezeridis PS, Boileau P, Deransart P, Chaoui J. Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study. J Shoulder Elb Surg. 2015;24:302–9.CrossRef Walch G, Vezeridis PS, Boileau P, Deransart P, Chaoui J. Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study. J Shoulder Elb Surg. 2015;24:302–9.CrossRef
16.
go back to reference Konrad G, Zwingmann J, Kotter E, Südkamp N, Oberst M. Variabilität der Schraubenlage bei 3D-navigierter Sakrumverschraubung. Unfallchirurg. 2010;113:29–35.CrossRef Konrad G, Zwingmann J, Kotter E, Südkamp N, Oberst M. Variabilität der Schraubenlage bei 3D-navigierter Sakrumverschraubung. Unfallchirurg. 2010;113:29–35.CrossRef
17.
go back to reference Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133:1257–65.CrossRef Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133:1257–65.CrossRef
18.
go back to reference Nguyen D, Ferreira LM, Brownhill JR, King GJW, Drosdowech DS, Faber KJ, et al. Improved accuracy of computer assisted glenoid implantation in total shoulder arthroplasty: an in-vitro randomized controlled trial. J Shoulder Elb Surg. 2009;18:907–14.CrossRef Nguyen D, Ferreira LM, Brownhill JR, King GJW, Drosdowech DS, Faber KJ, et al. Improved accuracy of computer assisted glenoid implantation in total shoulder arthroplasty: an in-vitro randomized controlled trial. J Shoulder Elb Surg. 2009;18:907–14.CrossRef
19.
go back to reference Nguyen D, Ferreira LM, Brownhill JR, Faber KJ, Johnson JA. Design and development of a computer assisted glenoid implantation technique for shoulder replacement surgery. Comput Aided Surg. 2007;12:152–9.CrossRef Nguyen D, Ferreira LM, Brownhill JR, Faber KJ, Johnson JA. Design and development of a computer assisted glenoid implantation technique for shoulder replacement surgery. Comput Aided Surg. 2007;12:152–9.CrossRef
20.
go back to reference Kircher J, Wiedemann M, Magosch P, Lichtenberg S, Habermeyer P. Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: a prospective-randomized clinical study. J Shoulder Elb Surg. 2009;18:515–20.CrossRef Kircher J, Wiedemann M, Magosch P, Lichtenberg S, Habermeyer P. Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: a prospective-randomized clinical study. J Shoulder Elb Surg. 2009;18:515–20.CrossRef
21.
go back to reference Sadoghi P, Vavken J, Leithner A, Vavken P. Benefit of intraoperative navigation on glenoid component positioning during total shoulder arthroplasty. Arch Orthop Trauma Surg. 2015;135:41–7.CrossRef Sadoghi P, Vavken J, Leithner A, Vavken P. Benefit of intraoperative navigation on glenoid component positioning during total shoulder arthroplasty. Arch Orthop Trauma Surg. 2015;135:41–7.CrossRef
22.
go back to reference Stübig T, Petri M, Zeckey C, Hawi N, Krettek C, Citak M, et al. 3D navigated implantation of the glenoid component in reversed shoulder arthroplasty. Feasibility and results in an anatomic study. Int J Med Robot. 2013;9:480–5.CrossRef Stübig T, Petri M, Zeckey C, Hawi N, Krettek C, Citak M, et al. 3D navigated implantation of the glenoid component in reversed shoulder arthroplasty. Feasibility and results in an anatomic study. Int J Med Robot. 2013;9:480–5.CrossRef
23.
go back to reference Theopold J, Pieroh P, Scharge ML, Marquaß B, Hohmann T, Josten C, et al. Improved accuracy of K-wire positioning into the glenoid vault by intraoperative 3D image intensifier-based navigation for the glenoid component in shoulder arthroplasty. Orthop Traumatol Surg Res. 2016;102:575–81.CrossRef Theopold J, Pieroh P, Scharge ML, Marquaß B, Hohmann T, Josten C, et al. Improved accuracy of K-wire positioning into the glenoid vault by intraoperative 3D image intensifier-based navigation for the glenoid component in shoulder arthroplasty. Orthop Traumatol Surg Res. 2016;102:575–81.CrossRef
24.
go back to reference Stübig T, Kendoff D, Citak M, Geerling J, Khalafi A, Krettek C, et al. Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care. J Trauma Inj Infect Crit Care. 2009;66:821–30.CrossRef Stübig T, Kendoff D, Citak M, Geerling J, Khalafi A, Krettek C, et al. Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care. J Trauma Inj Infect Crit Care. 2009;66:821–30.CrossRef
25.
go back to reference Codman. The Shoulder. Rupture of the supraspinatus tendon and other lesions in or about the subacromial bursa. Todd. 1934;:pp 318–319. Codman. The Shoulder. Rupture of the supraspinatus tendon and other lesions in or about the subacromial bursa. Todd. 1934;:pp 318–319.
26.
go back to reference Neer CS II. Four-segment classification of proximal humeral fractures: purpose and reliable use. J Shoulder Elb Surg. 2002;11:389–400.CrossRef Neer CS II. Four-segment classification of proximal humeral fractures: purpose and reliable use. J Shoulder Elb Surg. 2002;11:389–400.CrossRef
27.
go back to reference Lädermann A, Denard PJ. Arthroscopic Glenohumeral arthrodesis with O-arm navigation. Arthrosc Tech. 2014;3:e205–9.CrossRef Lädermann A, Denard PJ. Arthroscopic Glenohumeral arthrodesis with O-arm navigation. Arthrosc Tech. 2014;3:e205–9.CrossRef
28.
go back to reference Kotsianos D, Wirth S, Fischer T, Euler E, Rock C, Linsenmaier U, et al. 3D imaging with an isocentric mobile C-arm. Eur Radiol. 2004;14:1590–5.CrossRef Kotsianos D, Wirth S, Fischer T, Euler E, Rock C, Linsenmaier U, et al. 3D imaging with an isocentric mobile C-arm. Eur Radiol. 2004;14:1590–5.CrossRef
29.
go back to reference Stuby F, Seethaler AC, Shiozawa T. Vergleich der Bildqualität zweier unterschiedlicher mobiler 3-dimensionaler Röntgen-C-Bögen mit einem konventionellen CT bei der Darstellung relevanter Strukturen am knöchernen Becken. Z Orthop Unf. 2011;149:659–67.CrossRef Stuby F, Seethaler AC, Shiozawa T. Vergleich der Bildqualität zweier unterschiedlicher mobiler 3-dimensionaler Röntgen-C-Bögen mit einem konventionellen CT bei der Darstellung relevanter Strukturen am knöchernen Becken. Z Orthop Unf. 2011;149:659–67.CrossRef
30.
go back to reference Kotsianos D, Rock C, Wirth S, Linsenmaier U, Brandl R, Fischer T, et al. Frakturdiagnostik am Kniegelenk mit einem neuen mobilen CT-System (ISO-C-3D): Vergleich mit konventionellem Röntgen und Spiral-CT. RöFo - Fortschritte Auf Dem Geb Röntgenstrahlen Bildgeb Verfahr. 2002;174:82–7.CrossRef Kotsianos D, Rock C, Wirth S, Linsenmaier U, Brandl R, Fischer T, et al. Frakturdiagnostik am Kniegelenk mit einem neuen mobilen CT-System (ISO-C-3D): Vergleich mit konventionellem Röntgen und Spiral-CT. RöFo - Fortschritte Auf Dem Geb Röntgenstrahlen Bildgeb Verfahr. 2002;174:82–7.CrossRef
31.
go back to reference Frankle MA, Teramoto A, Luo Z-P, Levy JC, Pupello D. Glenoid morphology in reverse shoulder arthroplasty: classification and surgical implications. J Shoulder Elb Surg Am Shoulder Elb Surg Al. 2009;18:874–85.CrossRef Frankle MA, Teramoto A, Luo Z-P, Levy JC, Pupello D. Glenoid morphology in reverse shoulder arthroplasty: classification and surgical implications. J Shoulder Elb Surg Am Shoulder Elb Surg Al. 2009;18:874–85.CrossRef
32.
go back to reference Ohashi K, El-Khoury GY, Bennett DL, Restrepo JM, Berbaum KS. Orthopedic hardware complications diagnosed with multi–detector row CT. Radiology. 2005;237:570–7.CrossRef Ohashi K, El-Khoury GY, Bennett DL, Restrepo JM, Berbaum KS. Orthopedic hardware complications diagnosed with multi–detector row CT. Radiology. 2005;237:570–7.CrossRef
Metadata
Title
Real-time intraoperative 3D image intensifier-based navigation in reversed shoulder arthroplasty- analyses of image quality
Authors
Jan Theopold
Philipp Pieroh
Ralf Henkelmann
Georg Osterhoff
Pierre Hepp
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2019
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-019-2657-2

Other articles of this Issue 1/2019

BMC Musculoskeletal Disorders 1/2019 Go to the issue