Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 9/2013

01-09-2013 | Trauma Surgery

Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis

Authors: Jörn Zwingmann, Oliver Hauschild, Gerrit Bode, Norbert P. Südkamp, Hagen Schmal

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 9/2013

Login to get access

Abstract

Introduction

Percutaneous iliosacral screw placement following pelvic trauma is associated with high rates of revisions, screw malpositioning, the risk of neurological damage and inefficient stability. The correct entry point and the small target corridor may be difficult to visualize using only an image intensifier. Therefore, 2D and 3D image-based navigation and reconstruction techniques could be helpful tools. The aim of this systematic review and meta-analysis was to evaluate the best available evidence regarding the rate of malpositioning and revisions using different techniques for screw implantation, i.e., conventional, 2D and 3D image-based navigation and reconstruction techniques, CT navigation.

Methods

A systematic review and meta-analysis were performed using the data available on Ovid Medline. 430 studies published between 1/1948 and 2/2011 were identified by two independent investigators. Inclusion criteria were percutaneous iliosacral screw fixation after traumatic pelvic fractures with included revision rate or positioning of the screw, language of the article English or German. Exclusion criteria were osteoporotic fracture, tumor, reviews, epidemiological studies, biomechanical/cadaveric studies, studies about operative technique. For statistical analysis the random effect model was used.

Results

A total of 51 studies fulfilled the inclusion requirements describing 2,353 percutaneous screw implantations following pelvic trauma in 1,731 patients. The estimated rate of malposition was 0.1 % for 262 screws using CT navigation. This rate was significantly lower (p < 0.0001) than for the conventional technique with malposition rate of 2.6 % (total 1,832 screws). Using 2D and 3D image-based navigation and reconstruction techniques, the malposition rate was 1.3 % (total 445 screws). No significance was observed between the conventional and the 2D and 3D image-based navigation and reconstruction techniques. The rates of revision were not statistically significant with 2.7 % (1,832 implantations) in the conventional group, 1.3 % (445 implantations) in the group of 2D and 3D image-based navigation and reconstruction techniques and 0.8 % (262 implantations) using the CT navigation.

Conclusions

CT navigation has the lowest rate of screw malposition, but on the other hand it could not be used for all type of fractures where surgical procedures (reduction maneuvers, additional osteosynthetic procedures) are necessary. The 2D and 3D image-based navigation and reconstruction techniques provide encouraging results with slightly lower rate of complications compared to the conventional technique and are additional tools to enhance the precision and decrease the rate of revision.
Literature
1.
go back to reference Schep NW, Haverlag R, van Vugt AB (2004) Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma 57(6):1299–1302PubMedCrossRef Schep NW, Haverlag R, van Vugt AB (2004) Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma 57(6):1299–1302PubMedCrossRef
2.
go back to reference Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207–214PubMedCrossRef Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207–214PubMedCrossRef
3.
go back to reference Smith HE, Yuan PS, Sasso R, Papadopolous S, Vaccaro AR (2006) An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine 31(2):234–238PubMedCrossRef Smith HE, Yuan PS, Sasso R, Papadopolous S, Vaccaro AR (2006) An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine 31(2):234–238PubMedCrossRef
4.
go back to reference Sagi HC, Lindvall EM (2005) Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy. J Orthop Trauma 19(2):130–133 Epub 2005/01/29PubMedCrossRef Sagi HC, Lindvall EM (2005) Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy. J Orthop Trauma 19(2):130–133 Epub 2005/01/29PubMedCrossRef
5.
go back to reference Routt ML Jr, Simonian PT, Agnew SG, Mann FA (1996) Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study. J Orthop Trauma 10(3):171–177 Epub 1996/01/01PubMedCrossRef Routt ML Jr, Simonian PT, Agnew SG, Mann FA (1996) Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study. J Orthop Trauma 10(3):171–177 Epub 1996/01/01PubMedCrossRef
6.
go back to reference Matta JM, Saucedo T (1989) Internal fixation of pelvic ring fractures. Clin Orthop Relat Res 242:83–97PubMed Matta JM, Saucedo T (1989) Internal fixation of pelvic ring fractures. Clin Orthop Relat Res 242:83–97PubMed
7.
go back to reference Nelson DW, Duwelius PJ (1991) CT-guided fixation of sacral fractures and sacroiliac joint disruptions. Radiology 180(2):527–532PubMed Nelson DW, Duwelius PJ (1991) CT-guided fixation of sacral fractures and sacroiliac joint disruptions. Radiology 180(2):527–532PubMed
8.
go back to reference Routt ML Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11(8):584–589 Epub 1998/01/07PubMedCrossRef Routt ML Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11(8):584–589 Epub 1998/01/07PubMedCrossRef
9.
go back to reference Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallee S et al (2001) Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy. Comput Aided Surg 6(4):204–211PubMedCrossRef Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallee S et al (2001) Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy. Comput Aided Surg 6(4):204–211PubMedCrossRef
10.
go back to reference Zwingmann J, Konrad G, Kotter E, Sudkamp NP, Oberst M (2009) Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure. Clin Orthop Relat Res 467(7):1833–1838 Epub 2008/11/27PubMedCrossRef Zwingmann J, Konrad G, Kotter E, Sudkamp NP, Oberst M (2009) Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure. Clin Orthop Relat Res 467(7):1833–1838 Epub 2008/11/27PubMedCrossRef
11.
go back to reference Zwingmann J, Konrad G, Mehlhorn AT, Sudkamp NP, Oberst M (2010) Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. Conventional). J Trauma 69(6):1501–1506 Epub 2010/06/08PubMedCrossRef Zwingmann J, Konrad G, Mehlhorn AT, Sudkamp NP, Oberst M (2010) Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. Conventional). J Trauma 69(6):1501–1506 Epub 2010/06/08PubMedCrossRef
12.
go back to reference Gautier E, Bachler R, Heini PF, Nolte LP (2001) Accuracy of computer-guided screw fixation of the sacroiliac joint. Clin Orthop Relat Res 393:310–317PubMedCrossRef Gautier E, Bachler R, Heini PF, Nolte LP (2001) Accuracy of computer-guided screw fixation of the sacroiliac joint. Clin Orthop Relat Res 393:310–317PubMedCrossRef
13.
go back to reference Stockle U, Konig B, Hofstetter R, Nolte LP, Haas NP (2001) Navigation assisted by image conversion. An experimental study on pelvic screw fixation. Unfallchirurg 104(3):215–220PubMedCrossRef Stockle U, Konig B, Hofstetter R, Nolte LP, Haas NP (2001) Navigation assisted by image conversion. An experimental study on pelvic screw fixation. Unfallchirurg 104(3):215–220PubMedCrossRef
14.
go back to reference Ebraheim NA, Coombs R, Jackson WT, Rusin JJ (1994) Percutaneous computed tomography-guided stabilization of posterior pelvic fractures. Clin Orthop Relat Res 307:222–228PubMed Ebraheim NA, Coombs R, Jackson WT, Rusin JJ (1994) Percutaneous computed tomography-guided stabilization of posterior pelvic fractures. Clin Orthop Relat Res 307:222–228PubMed
15.
go back to reference Goldberg BA, Lindsey RW, Foglar C, Hedrick TD, Miclau T, Hadad JL (1998) Imaging assessment of sacroiliac screw placement relative to the neuroforamen. Spine 23(5):585–589PubMedCrossRef Goldberg BA, Lindsey RW, Foglar C, Hedrick TD, Miclau T, Hadad JL (1998) Imaging assessment of sacroiliac screw placement relative to the neuroforamen. Spine 23(5):585–589PubMedCrossRef
16.
go back to reference Barrick EF, O’Mara JW, Lane HE 3rd (1998) Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study. Comput Aided Surg 3(6):289–296PubMedCrossRef Barrick EF, O’Mara JW, Lane HE 3rd (1998) Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study. Comput Aided Surg 3(6):289–296PubMedCrossRef
17.
go back to reference Tonetti J, Carrat L, Lavallee S, Pittet L, Merloz P, Chirossel JP (1998) Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop Relat Res 354:103–110PubMedCrossRef Tonetti J, Carrat L, Lavallee S, Pittet L, Merloz P, Chirossel JP (1998) Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop Relat Res 354:103–110PubMedCrossRef
18.
go back to reference Cole JD, Blum DA, Ansel LJ (1996) Outcome after fixation of unstable posterior pelvic ring injuries. Clin Orthop Relat Res 329:160–179PubMedCrossRef Cole JD, Blum DA, Ansel LJ (1996) Outcome after fixation of unstable posterior pelvic ring injuries. Clin Orthop Relat Res 329:160–179PubMedCrossRef
19.
go back to reference Hinsche AF, Giannoudis PV, Smith RM (2002) Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res 395:135–144PubMedCrossRef Hinsche AF, Giannoudis PV, Smith RM (2002) Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res 395:135–144PubMedCrossRef
20.
go back to reference Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, O’Brien PJ (1999) Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma 13(2):107–113PubMedCrossRef Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, O’Brien PJ (1999) Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma 13(2):107–113PubMedCrossRef
21.
go back to reference Routt ML Jr, Simonian PT (1996) Closed reduction and percutaneous skeletal fixation of sacral fractures. Clin Orthop Relat Res 329:121–128PubMedCrossRef Routt ML Jr, Simonian PT (1996) Closed reduction and percutaneous skeletal fixation of sacral fractures. Clin Orthop Relat Res 329:121–128PubMedCrossRef
22.
go back to reference Ebraheim NA, Haman SP, Xu R, Stanescu S, Yeasting RA (2000) The lumbosacral nerves in relation to dorsal S1 screw placement and their locations on plain radiographs. Orthopedics 23(3):245–247PubMed Ebraheim NA, Haman SP, Xu R, Stanescu S, Yeasting RA (2000) The lumbosacral nerves in relation to dorsal S1 screw placement and their locations on plain radiographs. Orthopedics 23(3):245–247PubMed
23.
go back to reference Altman DT, Jones CB, Routt ML Jr (1999) Superior gluteal artery injury during iliosacral screw placement. J Orthop Trauma 13(3):220–227PubMedCrossRef Altman DT, Jones CB, Routt ML Jr (1999) Superior gluteal artery injury during iliosacral screw placement. J Orthop Trauma 13(3):220–227PubMedCrossRef
24.
go back to reference Stephen DJ (1997) Pseudoaneurysm of the superior gluteal arterial system: an unusual cause of pain after a pelvic fracture. J Trauma 43(1):146–149PubMedCrossRef Stephen DJ (1997) Pseudoaneurysm of the superior gluteal arterial system: an unusual cause of pain after a pelvic fracture. J Trauma 43(1):146–149PubMedCrossRef
25.
go back to reference Templeman D, Schmidt A, Freese J, Weisman I (1996) Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res 329:194–198PubMedCrossRef Templeman D, Schmidt A, Freese J, Weisman I (1996) Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res 329:194–198PubMedCrossRef
26.
go back to reference van den Bosch EW, van Zwienen CM, van Vugt AB (2002) Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma 53(1):44–48PubMedCrossRef van den Bosch EW, van Zwienen CM, van Vugt AB (2002) Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma 53(1):44–48PubMedCrossRef
27.
go back to reference Hanzlik S, Mahabir RC, Baynosa RC, Khiabani KT (2009) Levels of evidence in research published in The journal of bone and joint surgery (American volume) over the last thirty years. J Bone Joint Surg Am 91(2):425–428 Epub 2009/02/03PubMedCrossRef Hanzlik S, Mahabir RC, Baynosa RC, Khiabani KT (2009) Levels of evidence in research published in The journal of bone and joint surgery (American volume) over the last thirty years. J Bone Joint Surg Am 91(2):425–428 Epub 2009/02/03PubMedCrossRef
28.
go back to reference Majeed SA (1989) Grading the outcome of pelvic fractures. J Bone Joint Surg British Vol 71(2):304–306 Epub 1989/03/01 Majeed SA (1989) Grading the outcome of pelvic fractures. J Bone Joint Surg British Vol 71(2):304–306 Epub 1989/03/01
29.
go back to reference Rommens PM, Hessmann MH (2002) Staged reconstruction of pelvic ring disruption: differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions. J Orthop Trauma 16(2):92–98 Epub 2002/01/31PubMedCrossRef Rommens PM, Hessmann MH (2002) Staged reconstruction of pelvic ring disruption: differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions. J Orthop Trauma 16(2):92–98 Epub 2002/01/31PubMedCrossRef
30.
go back to reference Stockle U, Konig B, Schaffler A, Zschernack T, Haas NP (2006) Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery. Unfallchirurg 109(1):30–40PubMedCrossRef Stockle U, Konig B, Schaffler A, Zschernack T, Haas NP (2006) Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery. Unfallchirurg 109(1):30–40PubMedCrossRef
31.
go back to reference Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relat Res 422:201–207PubMedCrossRef Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relat Res 422:201–207PubMedCrossRef
32.
go back to reference Collinge C, Coons D, Tornetta P, Aschenbrenner J (2005) Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model. J Orthop Trauma 19(4):254–258PubMedCrossRef Collinge C, Coons D, Tornetta P, Aschenbrenner J (2005) Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model. J Orthop Trauma 19(4):254–258PubMedCrossRef
33.
go back to reference Day AC, Stott PM, Boden RA (2007) The accuracy of computer-assisted percutaneous iliosacral screw placement. Clin Orthop Relat Res 463:179–186PubMed Day AC, Stott PM, Boden RA (2007) The accuracy of computer-assisted percutaneous iliosacral screw placement. Clin Orthop Relat Res 463:179–186PubMed
34.
go back to reference Konrad G, Zwingmann J, Kotter E, Sudkamp N, Oberst M (2010) [Variability of the screw position after 3D-navigated sacroiliac screw fixation. Influence of the surgeon’s experience with the navigation technique]. Unfallchirurg 113(1): 29–35. (Epub 2009/10/29). Variabilitat der Schraubenlage bei 3D-navigierter Sakrumverschraubung. Einfluss der operateurspezifischen Navigationserfahrung Konrad G, Zwingmann J, Kotter E, Sudkamp N, Oberst M (2010) [Variability of the screw position after 3D-navigated sacroiliac screw fixation. Influence of the surgeon’s experience with the navigation technique]. Unfallchirurg 113(1): 29–35. (Epub 2009/10/29). Variabilitat der Schraubenlage bei 3D-navigierter Sakrumverschraubung. Einfluss der operateurspezifischen Navigationserfahrung
Metadata
Title
Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis
Authors
Jörn Zwingmann
Oliver Hauschild
Gerrit Bode
Norbert P. Südkamp
Hagen Schmal
Publication date
01-09-2013
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 9/2013
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-013-1788-4

Other articles of this Issue 9/2013

Archives of Orthopaedic and Trauma Surgery 9/2013 Go to the issue

Orthopaedic Surgery

Osteomyelitis