Skip to main content
Top
Published in: European Radiology 9/2008

01-09-2008 | Computer Tomography

Radiological profile of anemia on unenhanced MDCT of the thorax

Authors: Ehab M. Kamel, Elena Rizzo, Michel A. Duchosal, Rafael Duran, Vasco Goncalves-Matoso, Pierre Schnyder, Salah D. Qanadli

Published in: European Radiology | Issue 9/2008

Login to get access

Abstract

Our aim was to investigate the diagnostic value of unenhanced MDCT in anemic patients. Fifty consecutive patients with proven anemia and 50 nonanemic matched group for age, sex and body mass index were evaluated. In either group, hemoglobin levels were assessed no more than 24 h from an unenhanced CT of the thorax. For each patient, the presence of a hyperattenuating aortic wall (aortic ring sign) and/or dense interventricular septum (subjective parameters) were identified by two radiologists who were blinded to the laboratory findings. Furthermore, the aortic CT attenuation values (objective parameter) were also obtained and correlated with the hemoglobin levels. The sensitivity and specificity in detecting anemia were calculated for each variable, and ROC analysis was generated for subjective and objective parameters. Subjective image analysis revealed that the aortic ring sign was more sensitive than the interventricular septum sign for anemia detection (84% vs. 72%), whereas this latter sign was more specific (100% vs. 92%). A good correlation (r = 0.60) was observed between the aortic CT attenuation values and the hemoglobin levels in the whole study population. Using a threshold of ≤35 HU for anemia diagnosis, the sensitivity and specificity of aortic CT attenuation value were 84% and 94%, respectively, with the largest area under the curve (0.89) among all diagnostic criteria. However, the best trade-off between sensitivity (80%) and specificity (100%) was obtained from combining both subjective and objective analysis. Interpreting anemia upon unnenhanced MDCT of the thorax is quite feasible. A diagnostic approach that considers both subjective and objective analysis offers the best trade-off between sensitivity and specificity.
Literature
1.
go back to reference van de Wiel JC, Wang Y, Xu DM et al (2007) Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT. Eur Radiol 17:1474–1482PubMedCrossRef van de Wiel JC, Wang Y, Xu DM et al (2007) Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT. Eur Radiol 17:1474–1482PubMedCrossRef
2.
go back to reference Stillman AE, Oudkerk M, Ackerman M et al (2007) Use of multidetector computed tomography for the assessment of acute chest pain: a consensus statement of the North American Society of Cardiac Imaging and the European Society of Cardiac Radiology. Eur Radiol 17:2196–2207PubMedCrossRef Stillman AE, Oudkerk M, Ackerman M et al (2007) Use of multidetector computed tomography for the assessment of acute chest pain: a consensus statement of the North American Society of Cardiac Imaging and the European Society of Cardiac Radiology. Eur Radiol 17:2196–2207PubMedCrossRef
3.
go back to reference Goetze S, Pannu HK, Wahl RL (2006) Clinically significant abnormal findings on the “nondiagnostic” CT portion of low-amperage-CT attenuation-corrected myocardial perfusion SPECT/CT studies. J Nucl Med 47:1312–1318PubMed Goetze S, Pannu HK, Wahl RL (2006) Clinically significant abnormal findings on the “nondiagnostic” CT portion of low-amperage-CT attenuation-corrected myocardial perfusion SPECT/CT studies. J Nucl Med 47:1312–1318PubMed
4.
go back to reference Doppman JL, Rienmuller R, Lissner J (1981) The visualized interventricular septum on cardiac computed tomography: a clue to the presence of severe anemia. J Comput Assist Tomogr 5:157–160PubMedCrossRef Doppman JL, Rienmuller R, Lissner J (1981) The visualized interventricular septum on cardiac computed tomography: a clue to the presence of severe anemia. J Comput Assist Tomogr 5:157–160PubMedCrossRef
5.
go back to reference Wojtowicz J, Rzymski K, Czarnecki R (1983) Severe anaemia: its CT findings in the cardiovascular system. Eur J Radiol 3:108–111PubMed Wojtowicz J, Rzymski K, Czarnecki R (1983) Severe anaemia: its CT findings in the cardiovascular system. Eur J Radiol 3:108–111PubMed
6.
go back to reference Corcoran HL, Cook DE, Proto AV (1988) Diagnosis of anemia on computed tomography scans of the thorax. J Comput Tomogr 12:116–121PubMedCrossRef Corcoran HL, Cook DE, Proto AV (1988) Diagnosis of anemia on computed tomography scans of the thorax. J Comput Tomogr 12:116–121PubMedCrossRef
7.
go back to reference Collins AJ, Gillespie S, Kelly BE (2001) Can computed tomography identify patients with anaemia? Ulster Med J 70:116–118PubMed Collins AJ, Gillespie S, Kelly BE (2001) Can computed tomography identify patients with anaemia? Ulster Med J 70:116–118PubMed
8.
go back to reference Foster M, Nolan RL, Lam M (2003) Prediction of anemia on unenhanced computed tomography of the thorax. Can Assoc Radiol J 54:26–30PubMed Foster M, Nolan RL, Lam M (2003) Prediction of anemia on unenhanced computed tomography of the thorax. Can Assoc Radiol J 54:26–30PubMed
9.
go back to reference Title RS, Harper K, Nelson E, Evans T, Tello R (2005) Observer performance in assessing anemia on thoracic CT. AJR Am J Roentgenol 185:1240–1244PubMedCrossRef Title RS, Harper K, Nelson E, Evans T, Tello R (2005) Observer performance in assessing anemia on thoracic CT. AJR Am J Roentgenol 185:1240–1244PubMedCrossRef
10.
go back to reference Groopman JE, Itri LM (1999) Chemotherapy-induced anemia in adults: incidence and treatment. J Natl Cancer Inst 91:1616–1634PubMedCrossRef Groopman JE, Itri LM (1999) Chemotherapy-induced anemia in adults: incidence and treatment. J Natl Cancer Inst 91:1616–1634PubMedCrossRef
11.
go back to reference Spence RK (2007) Medical and economic impact of anemia in hospitalized patients. Am J Health Syst Pharm 64(16 Suppl 11):S3–S10PubMedCrossRef Spence RK (2007) Medical and economic impact of anemia in hospitalized patients. Am J Health Syst Pharm 64(16 Suppl 11):S3–S10PubMedCrossRef
12.
go back to reference Powell WJ, Wittenberg J, Dinsmore RE, Miller SW, Maturi RA (1977) Definition of cardiac structures using computerized tomography in isolated arrested and beating canine hearts. Am J Cardiol 39:690–696PubMedCrossRef Powell WJ, Wittenberg J, Dinsmore RE, Miller SW, Maturi RA (1977) Definition of cardiac structures using computerized tomography in isolated arrested and beating canine hearts. Am J Cardiol 39:690–696PubMedCrossRef
13.
go back to reference Ania BJ, Suman VJ, Fairbanks VF, Rademacher DM, Melton LJ 3rd (1997) Incidence of anemia in older people: an epidemiologic study in a well defined population. J Am Geriatr Soc 45:825–831PubMed Ania BJ, Suman VJ, Fairbanks VF, Rademacher DM, Melton LJ 3rd (1997) Incidence of anemia in older people: an epidemiologic study in a well defined population. J Am Geriatr Soc 45:825–831PubMed
14.
go back to reference Shiotani S, Kohno M, Ohashi N et al (2002) Hyperattenuating aortic wall on postmortem computed tomography (PMCT). Radiat Med 20:201–206PubMed Shiotani S, Kohno M, Ohashi N et al (2002) Hyperattenuating aortic wall on postmortem computed tomography (PMCT). Radiat Med 20:201–206PubMed
15.
go back to reference Sharma S, Sharma S, Taneja K, Gupta AK, Rajani M (1996) Morphologic mural changes in the aorta revealed by CT in patients with nonspecific aortoarteritis (Takayasu’s arteritis). AJR Am J Roentgenol 167:1321–1325PubMed Sharma S, Sharma S, Taneja K, Gupta AK, Rajani M (1996) Morphologic mural changes in the aorta revealed by CT in patients with nonspecific aortoarteritis (Takayasu’s arteritis). AJR Am J Roentgenol 167:1321–1325PubMed
16.
go back to reference Chung JW, Park JH, Im JG, Chung MJ, Han MC, Ahn H (1996) Spiral CT angiography of the thoracic aorta. Radiographics 16:811–824PubMed Chung JW, Park JH, Im JG, Chung MJ, Han MC, Ahn H (1996) Spiral CT angiography of the thoracic aorta. Radiographics 16:811–824PubMed
17.
go back to reference Castaner E, Andreu M, Gallardo X, Mata JM, Cabezuelo MA, Pallardo Y (2003) CT in nontraumatic acute thoracic aortic disease: typical and atypical features and complications. Radiographics 23:S93–S110PubMedCrossRef Castaner E, Andreu M, Gallardo X, Mata JM, Cabezuelo MA, Pallardo Y (2003) CT in nontraumatic acute thoracic aortic disease: typical and atypical features and complications. Radiographics 23:S93–S110PubMedCrossRef
18.
go back to reference Mulkens TH, Bellinck P, Baeyaert M et al (2005) Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 237:213–223PubMedCrossRef Mulkens TH, Bellinck P, Baeyaert M et al (2005) Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 237:213–223PubMedCrossRef
19.
go back to reference Kemper J, Regier M, Bansmann PM et al (2007) Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model. Eur Radiol 17:2318–2324PubMedCrossRef Kemper J, Regier M, Bansmann PM et al (2007) Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model. Eur Radiol 17:2318–2324PubMedCrossRef
Metadata
Title
Radiological profile of anemia on unenhanced MDCT of the thorax
Authors
Ehab M. Kamel
Elena Rizzo
Michel A. Duchosal
Rafael Duran
Vasco Goncalves-Matoso
Pierre Schnyder
Salah D. Qanadli
Publication date
01-09-2008
Publisher
Springer-Verlag
Published in
European Radiology / Issue 9/2008
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-0950-9

Other articles of this Issue 9/2008

European Radiology 9/2008 Go to the issue